Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TID”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

What Reliability Engineers Should Know about Space Radiation Effects

Space radiation in space systems present unique failure modes and considerations for reliability engineers. Radiation effects is not a one size fits all field. Threat conditions that must be addressed for a given mission depend on the mission orbital profile, the technologies of parts used in critical functions and on application considerations, such as supply voltages, temperature, duty cycle, and redundancy. In general, the threats that must be addressed are of two types-the cumulative degradation mechanisms of total ionizing dose (TID) and displacement damage (DD). and the prompt responses of components to ionizing particles (protons and heavy ions) falling under the heading of single-event effects. Generally degradation mechanisms behave like wear-out mechanisms on any active components in a system: Total Ionizing Dose (TID) and Displacement Damage: (1) TID affects all active devices over time. Devices can fail either because of parametric shifts that prevent the device from fulfilling its application or due to device failures where the device stops functioning altogether. Since this failure mode varies from part to part and lot to lot, lot qualification testing with sufficient statistics is vital. Displacement damage failures are caused by the displacement of semiconductor atoms from their lattice positions. As with TID, failures can be either parametric or catastrophic, although parametric degradation is more common for displacement damage. Lot testing is critical not just to assure proper device fi.mctionality throughout the mission. It can also suggest remediation strategies when a device fails. This paper will look at these effects on a variety of devices in a variety of applications. This paper will look at these effects on a variety of devices in a variety of applications. (2) On the NEAR mission a functional failure was traced to a PIN diode failure caused by TID induced high leakage currents. NEAR was able to recover from the failure by reversing the current of a nearby Thermal Electric Cooler (turning the TEC into a heater). The elevated temperature caused the PIN diode to anneal and the device to recover. It was by lot qualification testing that NEAR knew the diode would recover when annealed. This paper will look at these effects on a variety of devices in a variety of applications. Single Event Effects (SEE): (1) In contrast to TID and displacement damage, Single Event Effects (SEE) resemble random failures. SEE modes can range from changes in device logic (single-event upset, or SEU). temporary disturbances (single-event transient) to catastrophic effects such as the destructive SEE modes, single-event latchup (SEL). single-event gate rupture (SEGR) and single-event burnout (SEB) (2) The consequences of nondestructive SEE modes such as SEU and SET depend critically on their application--and may range from trivial nuisance errors to catastrophic loss of mission. It is critical not just to ensure that potentially susceptible devices are well characterized for their susceptibility, but also to work with design engineers to understand the implications of each error mode. -For destructive SEE, the predominant risk mitigation strategy is to avoid susceptible parts, or if that is not possible. to avoid conditions under which the part may be susceptible. Destructive SEE mechanisms are often not well understood, and testing is slow and expensive, making rate prediction very challenging. (3) Because the consequences of radiation failure and degradation modes depend so critically on the application as well as the component technology, it is essential that radiation, component. design and system engineers work togetherpreferably starting early in the program to ensure critical applications are addressed in time to optimize the probability of mission success.

DiBari, Rebecca↗

Test and Evaluation of Radiofrequency Tamper Indicating Devices for Remote Monitoring of Advanced/Small Modular Reactors

Advanced and small modular reactors (A/SMRs), due to their versatile nature, are likely to be used in remote locations to provide electrical power or other services in regions that are difficult to access or have limited transportation infrastructure. This will result in limited on-site staff, therefore driving A/SMR vendors to consider remote monitoring as a solution to support nuclear security. Maintaining Continuity of Knowledge (CoK) of nuclear material quantities and locations is vital to nuclear security, and remote monitoring of active tamper indicating devices (TIDs) has been well established as a component of International Atomic Energy Agency (IAEA) Safeguards since the early 2000s. Active TIDs, such as radiofrequency TIDs (RFTIDs), immediately alarm upon unauthorized access attempts, promoting timely detection. In contrast, passive TIDs require a surveillance regime and offer delayed detection. Active TIDs deter insiders and enable prompt detection of malicious acts. They can be used on nuclear material containers and controlled entry points like vaults and toolboxes. Therefore, the implementation of RFTIDs into security programs bolsters overall nuclear material control, and provides a visible deterrent, with primary efficacy in mitigating the insider threat and potentially allowing for Security by Design considerations. They are a strong candidate technology for maintaining nuclear security of A/SMRs but need to be evaluated for feasibility and implementation into the wider physical protection system.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mid-latitude ionospheric irregularity spectral density as determined by ground-based GPS receiver networks

In this paper, we present a new technique to experimentally measure the spatial spectrum of ionospheric disturbances in the spatial scale regime of 40 – 200 km. This technique produces a 2-dimensional (2-D) spectrum for each time snapshot over two dense GPS receiver networks (GEONET in Japan and PBO in the Western U.S.). Because this technique created the spectrum from an instantaneous time snapshot, no assumptions are needed about the speed of ionospheric irregularities. We examine spectra from three days: one with an intense geomagnetic storm, one with significant lightning activity, and one quiet day. Radial slices along the 2-D spectra provide 1-dimensional spectra that can be fit to a power law to quantify the steepness of the fall-off in the spatial scale sizes. Continuous data of this type in a stationary location allows monitoring the variability in the 2-D spectrum over the course of a day and comparing between days, as shown here, or even over a year or many years. We find that the spectra are highly variable over the course of a day and between the two selected regions of Japan and the Western U.S. When strong travelling ionospheric disturbances (TIDs) are present, the 2-D spectra provide information about the direction of propagation of the TIDs. We compare the TID propagation direction with horizontal wind directions from the Horizontal Wind Model. Finally, TID direction is correlated with the horizontal wind direction on all days, strongly indicating that the primary source of the TIDs measured by this technique is tropospheric.

79 ASTRONOMY AND ASTROPHYSICS↗

Ionizing radiation effects in SONOS-based neuromorphic inference accelerators

Here, we evaluate the sensitivity of neuromorphic inference accelerators based on Silicon-Oxide-Nitride-Oxide-Silicon (SONOS) charge trap memory arrays to total ionizing dose (TID) effects. Data retention statistics were collected for 16 Mbit of 40 nm SONOS digital memory exposed to ionizing radiation from a Co-60 source, showing good retention of the bits up to the maximum dose of 500 krad(Si). Using this data, we formulate a rate-equation-based model for the TID response of trapped charge carriers in the ONO stack, and predict the effect of TID on intermediate device states between ‘program’ and ‘erase’. This model is then used to simulate arrays of low-power, analog SONOS devices that store 8-bit neural network weights and support in situ matrix-vector multiplication. We evaluate the accuracy of the irradiated SONOS-based inference accelerator on two image recognition tasks – CIFAR-10 and the challenging ImageNet dataset – using state-of-the-art convolutional neural networks, such as ResNet-50. We find that across the datasets and neural networks evaluated, the accelerator tolerates a maximum TID between 10 krad(Si) and 100 krad(Si), with deeper networks being more susceptible to accuracy losses due to TID.

43 PARTICLE ACCELERATORS↗

Radiation Hardened Electronics Destined For Severe Nuclear Reactor Environments

Post nuclear accident conditions represent a harsh environment for electronics. The full station blackout experience at Fukushima shows the necessity for emergency sensing capabilities in a radiation-enhanced environment. This NEET (Nuclear Energy Enabling Technologies) research project developed radiation hardened by design (RHBD) electronics using commercially available technology that employs commercial off-the-shelf (COTS) devices and present generation circuit fabrication techniques to improve the total ionizing dose (TID) hardness of electronics. Such technology not only has applicability to severe accident conditions but also to facilities throughout the nuclear fuel cycle in which radiation tolerance is required. For example, with TID tolerance to megarads of dose, electronics could be deployed for long-term monitoring, inspection and decontamination missions. The present work has taken a two-pronged approach, specifically, development of both board and application-specific integrated circuit (ASIC) level RHBD techniques. The former path has focused on TID testing of representative microcontroller ICs with embedded flash (eFlash) memory, as well as standalone flash devices that utilize the same fabrication technologies. The standalone flash devices are less complicated, allowing better understanding of the TID response of the crucial circuits. Our TID experiments utilize biased components that are in-situ tested, and in full operation during irradiation. A potential pitfall in the qualification of memory circuits is the lack of rigorous testing of the possible memory states. For this reason, we employ test patterns that include all ones, all zeros, a checkerboard of zeros and ones, an inverse checkerboard, and random data. With experimental evidence of improved radiation response for unbiased versus biased conditions, a demonstration-level board using the COTS devices was constructed. Through a combination of redundancy and power gating, the demonstration board exhibits radiation resilience to over 200 krad. Furthermore, our ASIC microprocessor using RHBD techniques was shown to be fully functional after an exposure of 2.5 Mrad whereas the COTS microcontroller units failed catastrophically at <100 krad. The methods developed in this work can facilitate the long-term viability of radiation-hard robotic systems, thereby avoiding obsolescence issues. As a case in point, the nuclear industry with its low purchasing power does not drive the semiconductor industry strategic plans, and the rapid advancements in electronics technology can leave legacy systems stranded.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

INS Nuclear Material Accounting and Control Instructional Video Materials- FY 25 Guides

This training video provides an essential guide to understanding and utilizing Tamper Indicating Devices (TIDs), with a specific focus on a common Mylar (Adhesive) variety during the application process. TIDs are a critical part of nuclear security, used to detect unauthorized access to sensitive materials or facilities. The Mylar (adhesive) TID employes a tamper-evident film integrated into the TID that visually indicates any tampering attempts. This video will explain how an example Mylar (adhesive) TID works, demonstrate proper installation techniques, and highlight how to interpret its indicators to ensure the security of nuclear materials.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Antifuse FPGA for Space Applications

This paper presents viewgraphs of Antifuse FPGA (Field Programmable Gate Array) for Space Applications. The topics include: 1) A32140DX TID Test; 2) A1280XL Proton Test; 3) SEU (Single Event Upsets) Rate Calculation; 4) Recent Products Test; 5) A1460A TID (Traveling Ionospheric Disturbances) Test; 6) I100 Proton Test; 7) 100/RHI100 SEU Test; 8) I100/RH100 TID Test; 9) A1020S TID Test; 10) TID Charge Pump Failure; 11) Radiation Testing; and SEE (Single Event Effects) Test Setup.

Wang, Jih-Jong↗

Shielding Considerations for CubeSat Structures During Solar Maximum

The purpose of this lessons learned is to communicate the utility of shielding in small spacecraft planning for the support of mission assurance and reliability. Numerous SmallSats have been flying in polar low earth orbit for scientific, communications, technology demonstrations, and imaging with academic, commercial, and government interests. Shielding has been part of mission assurance and reliability from the advent of long duration spacecraft missions. The Shields-1 CubeSat has been operating in polar low earth orbit since 16 December 2018 with atomic number (Z)-grade radiation shielding and demonstrates shielding effectiveness. Shields-1 has collected a representative example of solar minimum data in 2019 with 8 Teledyne dosimeters over varying shielding effectiveness. It serves as current experimental data and has been compared with NOVICE Shielding estimates using the AP8 –AE8 trapped radiation model with the Shields-1 CAD and generic CubeSat 3 unit (U) models. Using NOVICE model radiation analysis coding, the shielding effectiveness's, based on a generic CubeSat 3U structure with 4 electronic boards, were estimated for aluminum wall thicknesses ranging from 0.204 cmto4.44 cm (0.550 g/cm2–12.0 g/cm2) thick aluminum. For modeled polar orbiting spacecraft, solar maximum total ionizing dose (TID)increases by nearly a magnitude for thin-walled aluminum 0.550g/cm2-0.686 g/cm2(0.204 cm –0.254 cm) typical CubeSat structures. The shielding effectiveness by NOVICE Sigma estimates, which is a shielding sphere approximation around a detector, showed a linear relationship with wall thickness, which increased over the wall thickness by a ratio of 1.43 determined by linear regression analysis. Using NOVICE Adjoint Monte-Carlo Modeling of solar minimum and solar maximum with the inclusion of a worst-case solar particle event over a one year mission without geomagnetic shielding, the TID for minimum and maximum conditions for a generic 3U with a wall thickness of 0.254 cm is 158 RAD and 1540 RAD, respectively. The modeled total solar maximum TID is over estimated, because at low orbital latitudes a spacecraft will have shielding from Earth's magnetic field. However, TID will still be significant at high latitudes over the poles, where a spacecraft is exposed in a solar particle event. In contrast, to a thin walled generic 3U CubeSat, Shields-1 electronics enclosure has a shielding effectiveness of 21.3 g/cm2from NOVICE Sigma modeling and is expected to show reduced total ionizing dose increases during the present active Solar Cycle 25 period. Because solar particle events during solar maximum increase TID on electronic parts with thin-walled shielding in short periods of time, it is a mission assurance and reliability consideration on the spacecraft’s mission value versus adding shielding for risk reduction of premature spacecraft or instrument payload loss. Since the volumes of many instruments and system electronics have reduced with small spacecraft, shielding material costs and weight penalties have diminished. A small spacecraft project budget and schedule may limit traditional radiation-hardened part use and radiation testing requirements, where shielding can contribute to mission assurance and reliability with reduced costs.

Shields-1↗

Shielding Considerations for CubeSat Structures During Solar Maximum

The purpose of this lessons learned paper is to communicate the utility of shielding in small spacecraft planning for the support of mission assurance and reliability. Numerous SmallSats have been flying in polar low Earth orbit for science, communications, technology demonstrations, and imaging with academic, commercial, and government interests. Shielding has been part of mission assurance and reliability from the advent of long duration spacecraft missions. The Shields-1 CubeSat has been operating in polar low Earth orbit since 16 December 2018 with atomic number (Z)-grade radiation shielding and demonstrates shielding effectiveness. Shields-1 has collected a representative example of solar minimum data in 2019 with eight Teledyne µDosimeters over varying shielding effectivenesses. It serves as current experimental data and has been compared with NOVICE Shielding estimates using the AP8 – AE8 trapped radiation model with the Shields-1 CAD and generic CubeSat three unit (3U) models. Using NOVICE model radiation analysis coding, the shielding effectivenesses, based on a generic CubeSat 3U structure with four electronic boards, were estimated for aluminum wall thicknesses ranging from 0.204 cm to 4.44 cm (0.550 g/cm 2 to 12.0 g/cm 2 ). For modeled polar orbiting spacecraft, solar maximum total ionizing dose (TID) increases by nearly a magnitude for thin-walled aluminum 0.550-g/cm 2 - 0.686-g/cm 2 (0.204-cm – 0.254-cm) typical CubeSat structures. The shielding effectiveness estimated by NOVICE Sigma, which is a shielding sphere approximation around a detector, showed a linear relationship with wall thickness, which increased over the wall thickness by a ratio of 1.43 determined by linear regression analysis. Using NOVICE Adjoint Monte-Carlo Modeling of solar minimum and solar maximum with the inclusion of a worst-case solar particle event over a one-year mission without geomagnetic shielding, the TID for minimum and maximum conditions for a generic 3U with a wall thickness of 0.254 cm is 158 RAD and 1540 RAD, respectively. The modeled total solar maximum TID is over estimated, because at low orbital latitudes a spacecraft will have shielding from the Earth’s magnetic field. However, TID will still be significant at high latitudes over the poles, where a spacecraft is exposed in a solar particle event. In contrast to a thin-walled generic 3U CubeSat, the Shields-1 electronics enclosure has a shielding effectiveness of 21.3 g/cm 2 from NOVICE Sigma modeling and is expected to show reduced total ionizing dose increases during the present active Solar Cycle 25 period. Because solar particle events during solar maximum increase TID on electronic parts with thin-walled shielding in short periods of time, it is a mission assurance and reliability consideration on the mission value of the spacecraft versus adding shielding for risk reduction of premature spacecraft or instrument payload loss. Since the volumes of many instruments and system electronics have reduced with small spacecraft, shielding material costs and weight penalties have diminished. A small spacecraft project budget and schedule may limit traditional radiation-hardened part use and radiation testing requirements, where shielding can contribute to mission assurance and reliability with reduced costs.

Shields-1↗

Development of COTS ADC SEE Test System for the ATLAS LArCalorimeter Upgrade

Radiation-tolerant, high speed, high density and low power commercial off-the-shelf (COTS) analog-to-digital converters (ADCs) are planned to be used in the upgrade to the Liquid Argon (LAr) calorimeter front end (FE) trigger readout electronics. Total ionization dose (TID) and single event effect (SEE) are two important radiation effects which need to be characterized on COTS ADCs. In our initial TID test, Texas Instruments (TI) ADS5272 was identified to be the top performer after screening a total 17 COTS ADCs from different manufacturers with dynamic range and sampling rate meeting the requirements of the FE electronics. Another interesting feature of ADS5272 is its 6.5 clock cycles latency, which is the shortest among the 17 candidates. Based on the TID performance, we have designed a SEE evaluation system for ADS5272, which allows us to further assess its radiation tolerance. In this paper, we present a detailed design of ADS5272 SEE evaluation system and show the effectiveness of this system while evaluating ADS5272 SEE characteristics in multiple irradiation tests. According to TID and SEE test results, ADS5272 was chosen to be implemented in the full-size LAr Trigger Digitizer Board (LTDB) demonstrator, which will be installed on ATLAS calorimeter during the 2014 Long Shutdown 1 (LS1).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Terrestrial Sources of X-Ray Radiation and Their Effects on NASA Flight Hardware

X-rays are an energetic and penetrating form of ionizing electromagnetic radiation, which can degrade NASA flight hardware. The main concern posed by such radiation is degradation of active electronic devices and, in some cases, diodes. Non-electronic components are only damaged at doses that far exceed the point where any electronic device would be destroyed. For the purposes of this document, flight hardware can be taken to mean an entire instrument, the flight electronics within the instrument or the individual microelectronic devices in the flight electronics. This document will discuss and describe the ways in which NASA flight hardware might be exposed to x-rays, what is and isn't a concern, and how to tell the difference. First, we must understand what components in flight hardware may be vulnerable to degradation or failure as a result of being exposed to ionizing radiation, such as x-rays. As stated above, bulk materials (structural metals, plastics, etc.) are generally only affected by ionizing radiation at very high dose levels. Likewise, passive electronic components (e.g. resistors, capacitors, most diodes) are strongly resistant to exposure to x-rays, except at very high doses. The main concerns arise when active components, that is, components like discrete transistors and microelectronic devices, are exposed to ionizing radiation. Active components are designed to respond to minute changes in currents and voltages in the circuit. As such, it is not surprising that exposure to ionizing radiation, which creates ionized and therefore electrically active particles, may degrade the way the hardware performs. For the most part, the mechanism for this degradation is trapping of the charges generated by ionizing radiation by defects in dielectric materials in the hardware. As such, the degree of damage is a function of both the quantity of ionizing radiation exposure and the physical characteristics of the hardware itself. The metric that describes the level of exposure to ionizing radiation is total ionizing dose (TID). The unit of TID is the rad, which is defined as 100 ergs absorbed per gram of material. Dose can be expressed in other units, for example grays (gy), where 1 gy = 100 rads. The actual fluence of radiation needed to deliver a rad depends on the absorbing material, so units of dose are usually stated in reference to the material of interest. That is, for microelectronic devices, the unit of dose is generally rad (Si) or rad (SiO2). However, the definition of absorbed dose in this fashion has the advantage that the type of radiation causing the ionization can be normalized so that a realistic and adequate comparison can be made. The sensitivity of microelectronic parts to TID varies over many orders of magnitude. (Note: Doses to humans are typically expressed in rems-or roentgen-equivalent-man-which measures tissue damage, and depends on the type of radiation, as well as the dose in rads.) Thus far, the "softest" parts tested at NASA showed damage at 500 rads (Si), while parts that are radiation-hardened by design can remain functional to doses on the order of 107 rads (Si). This broad range of sensitivity highlights one of the most important considerations when considering the effects of radiation on electronic parts: In order to determine whether a radiation exposure is a concern for a particular part, one must understand the technologies used in the part and their vulnerabilities to TID damage. A NASA radiation expert should be consulted to obtain such information.

X-ray↗

Impact of renin–angiotensin–aldosterone system polymorphisms on myocardial perfusion: Correlations with myocardial single photon emission computed tomography-derived parameters

Background: Renin–angiotensin–aldosterone system (RAAS) has an important role in atherosclerosis. We investigated the effects of six RAAS gene polymorphisms on myocardial perfusion. Methods and Results: We examined 810 patients with known or suspected coronary artery disease (CAD) using stress–rest myocardial single-photon emission computed tomography. Summed stress score (SSS), summed rest score (SRS), summed difference score (SDS), transient ischemic dilation (TID), and lung/heart ratio (LHR) were recorded. The following gene polymorphisms were investigated: angiotensin-converting enzyme (ACE) insertion/deletion (I/D), angiotensinogen (AGT) M235T and T174M, angiotensin II type 1 receptor (AT1R) A1166C, renin (REN) C5312T, and angiotensin II type 2 receptor (AT2R) C3123A. The heterozygotes or homozygotes on ACE D allele were 7.54 times more likely to have abnormal SSS, while the AGT (T174M) heterozygotes were 5.19 times more likely to have abnormal SSS. The homozygotes of ACE D had significantly higher values on TID and LHR, while the AGT (T174M) heterozygotes had higher values on TID. The AT1R heterozygotes had greater odds for having SSS ≥ 3. The patients carried AT1R homozygosity of C allele had significantly higher values on TID, while heterozygotes of AT1R had significantly higher values on LHR. Conclusions: Among the polymorphisms investigated, ACE D allele had the strongest association with abnormal myocardial perfusion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radio interferometric detection of a traveling ionospheric disturbance excited by the explosion of Mount St. Helens

A large-amplitude traveling ionospheric disturbance (TID) was detected over Owens Valley, California, on May 18, 1980, by a highly sensitive very long baseline interferometry (VLBI) radio astronomy experiment. This TID is interpreted as the response of the ionosphere to a gravity wave excited in the neutral atmosphere by the explosion of Mount St. Helens that took place at 1532 UT on that day. A model, invoking the point-excitation of internal gravity waves in an isothermal atmosphere, which fits observations of the TID at several other stations, leads to identification of the features observed in the VLBI data. Small-amplitude higher-frequency changes in the ionosphere were detected for several hours after the passage of the large-amplitude Mount St. Helens TID, but it is not clear whether these were excited by the passage of the gravity wave or were background fluctuations.

Roberts, D. H.↗

An observation of atmospheric gravity wave cause and effect during October 1985 WAGS campaign

Moderate geomagnetic activity followed by a large scale TID was observed in Europe and eastern North America near 1200 UT on October 18, 1985 during the Worldwide Atmospheric Gravity Wave Study. The speed and direction of the TID are estimated, suggesting that it was caused by an atmospheric gravity wave expanding from a localized source over the Arctic Ocean. Auroral imaging shows that the source region was located near the westward edge of an expanding auroral bulge and may have been associated with a westward traveling surge. The TID periods increased with distance from the source region and the largest TID amplitudes were seen along a line perpendicular to the orientation of the auroral oval.

Rice, D. D.↗

Estimating gravity wave parameters from oblique high-frequency backscatter: Modeling and analysis

A new technique for estimating electron density perturbation amplitudes of traveling ionospheric disturbances (TIDs), using HF radar data, is presented. TIDs are observed in HF radar data as enhancements of the ground-scattered power which propagate through the radar's field of view. These TIDs are the ionospheric manifestation of atmospheric acoustic-gravity waves. TID electron density perturbation amplitudes were estimated by simulating the radar returns, using HF ray tracing through a model ionosphere perturbed by a model gravity wave. The simulation determined the return power in the ground-scattered portion of the signal as a function of range, and this was compared to HF radar data from the Goose Bay HF radar at a time when evidence of gravity waves was present in the data. By varying the amplitude of the electron density perturbation in the model it was possible to estimate the perturbation of the actual wave. It was found that the perturbations that are observed by the Goose Bay HF radar are of the order of 20% to 35%. It was also found that the number of observable power enhancements, and the relative amplitudes of these enhancements, depended on the vertical thickness of the gravity wave's source region. From the simulations and observations it was estimated that the source region for the case presented here was approximately 20 km thick. In addition, the energy in the wave packet was calculated and compared to an estimate of the available energy in the source region. It was found that the wave energy was about 0.2% of the estimated available source region energy.

Bristow, W. A.↗

Microfabricated thermionic detector

A microfabricated TID comprises a microhotplate and a thermionic source disposed on the microhotplate. The microfabricated TID can provide high sensitivity and selectivity to nitrogen- and phosphorous-containing compounds and other compounds containing electronegative function groups. The microfabricated TID can be microfabricated with semiconductor-based materials. The microfabricated TID can be combined with a microfabricated separation column and used in microanalytical system for the rapid on-site detection of pesticides, chemical warfare agents, explosives, pharmaceuticals, and other organic compounds that contain nitrogen or phosphorus.

47 OTHER INSTRUMENTATION↗

Total Integrated Dose to Spent Fuel Pool Level Instrument Probes and Refueling Floor Personnel Dose Rates Meeting NRC Order EA-12-051 for a Typical Boiling Water Reactor - Paper 22

In reviewing the events after the March 11, 2011 Fukushima accident, the Nuclear Regulatory Commission (NRC) issued Order EA-12-051, Reference 1, requiring new reliable spent fuel pool (SFP) instrumentation for pool level determination under beyond design basis event conditions. In 2013, URS prepared a calculation for a typical Boiling Water Reactor to determine the Total Integrated Dose (TID) potentially to be imparted to radiation sensitive underwater probes (one primary and one backup) planned for meeting this Order. Additionally, URS calculated the radiological dose rates to an individual standing on the refueling floor for various SFP fill levels. NEI 12-02, Reference 2, defines the levels at which SFP condition identification is necessary as the following: Level 1 - level that is adequate to support operation of the normal fuel pool cooling system. Level 1 represents the higher of the following two points: - The level at which reliable suction loss occurs due to uncovering of the coolant inlet pipe, weir or vacuum breaker (depending on the design), or - The level at which the water height, assuming saturated conditions, above the centerline of the cooling pump suction provides the required net positive suction head specified by the pump manufacturer or engineering analysis. Level 2 - level that is adequate to provide substantial radiation shielding for a person standing on the spent fuel pool operating deck. Level 2 is based on either of the following: - 10 feet (+/- 1 foot) above the highest point of any fuel rack seated in the spent fuel pools, or - A designated level that provides adequate radiation shielding to maintain personnel radiological dose levels within acceptable limits while performing local operations in the vicinity of the pool. This level shall be based on either plant-specific or appropriate generic shielding calculations, considering the emergency conditions that may apply at the time and the scope of necessary local operations, including installation of portable SFP instrument channel components. Level 3 - level where fuel remains covered and actions to implement make-up water addition should no longer be deferred. Level 3 corresponds nominally (i.e. +/- 1 foot) to the highest point of any fuel rack seated in the spent fuel pool. The URS calculation did not define these levels or determine instrumentation setpoints. However, it determined refueling floor dose rates that could be used as a tool to determine the appropriate water depths for these levels. In determining the TID for the SFP probes and the radiological dose rates to the individual, the following radioactive sources were considered: 1. Spent Nuclear Fuel (SNF) stored in the spent fuel storage racks, 2. Local Power Range Monitors (LPRMs) stored above the top of the racks on hangers on the SFP walls 3. Radioactive material laden filters stored on platforms on top of the racks, and 4. Control Rod Blades (CRBs) stored above the top of the racks on hangers on the SFP walls. The TID for the SFP probes includes both the dose from normal operation (pool full of water) for the remaining plant life (an assumed 40 years, conservatively including an allowance for lifetime extension SFP loading) and, consistent with the NEI 12-02 guidelines, Reference 2, the assumed drop in elevation of the pool water level to the top of the spent fuel racks for a 6 hour period. The acceptable TID for the radiation-sensitive probe as defined by the manufacturer was 2x10{sup 9} rad. The individual on the pool deck was assumed to be standing on the edge of the pool with an unobstructed view of its contents, as a worst case scenario. Dose rates to this individual determined from direct shine from the same 4 sources were determined for SFP water levels varying from 1 ft above the SNF racks to 21 ft above the racks in one foot increments. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The susceptibility of TaO x -based memristors to high dose rate ionizing radiation and total ionizing dose

This paper investigates the effects of high dose rate ionizing radiation and total ionizing dose (TID) on tantalum oxide (TaO x ) memristors. Transient data were obtained during the pulsed exposures for dose rates ranging from approximately 5.0 ×10 7 rad(Si)/s to 4.7 ×10 8 rad(Si)/s and for pulse widths ranging from 50 ns to 50 μs. The cumulative dose in these tests did not appear to impact the observed dose rate response. Static dose rate upset tests were also performed at a dose rate of ~3.0 ×10 8 rad(Si)/s. This is the first dose rate study on any type of memristive memory technology. In addition to assessing the tolerance of TaO x memristors to high dose rate ionizing radiation, we also evaluated their susceptibility to TID. The data indicate that it is possible for the devices to switch from a high resistance off-state to a low resistance on-state in both dose rate and TID environments. The observed radiation-induced switching is dependent on the irradiation conditions and bias configuration. Furthermore, the dose rate or ionizing dose level at which a device switches resistance states varies from device to device; the enhanced susceptibility observed in some devices is still under investigation. As a result, numerical simulations are used to qualitatively capture the observed transient radiation response and provide insight into the physics of the induced current/voltages.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗