Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TENDONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Modifying the strength and strain concentration profile within collagen scaffolds using customizable arrays of poly-lactic acid fibers

Here, the tendon-to-bone junction is a highly specialized tissue which dissipates stress concentrations between mechanically dissimilar tendon and bone. Upon injury, the local heterogeneities across this insertion are not regenerated, leading to poor functional outcomes such as formation of scar tissue at the insertion and re-failure rates exceeding 90%. Although current tissue engineering methods are moving towards the development of spatially-graded biomaterials to begin to address these injuries, significant opportunities remain to engineer the often complex local mechanical behavior of such biomaterials to enhance their bioactivity. Here, we describe the use of three-dimensional printing techniques to create customizable arrays of poly-lactic acid (PLA) fibers that can be incorporated into a collagen scaffold under development for tendon bone junction repair. Notably, we use additive manufacturing concepts to generate arrays of spatially-graded fibers from biodegradable PLA that are incorporated into collagen scaffolds to create a collagen-PLA composite. We demonstrate the ability to tune the mechanical performance of the fiber-scaffold composite at the bulk scale. We also demonstrate the incorporation of spatially-heterogeneous fiber designs to establish non-uniform local mechanical performance of the composite biomaterial under tensile load, a critical element in the design of multi-compartment biomaterials for tendon-to-bone regeneration applications. Together, this work highlights the capacity to use multi-scale composite biomaterials to control local and bulk mechanical properties, and provides key insights into design elements under consideration for mechanically competent, multi-tissue regeneration platforms.

3D printing↗

The bearable lightness of being: bones, muscles, and spaceflight

Bones and muscles support and move the body. Tendons link the two tissues and serve as a mechanism for transfer of forces from muscle to bone. These three tissues interact and respond to periods of activity or inactivity with appropriate alterations in structure and strength. There is substantial evidence that an environment devoid of mechanical stress on the skeleton (such as reduced gravitational forces during spaceflight, a "microgravity environment") produces direct effects on bone structure and function. There is little agreement concerning the biologic mechanisms for these atrophic changes. Changes in fluid balance and distribution coincident to spaceflight also affect muscles and bones by an unknown mechanism. Tendon-bone junctions are presumed to be spared from the effects of spaceflight. However, recent evidence from rodents suggests that spaceflight profoundly effects both the skeleton and the tendon-bone junctions. These effects include cortical bone resorption, which undermines the Sharpey's fibers that anchor the tendon to the bone matrix. The challenge to biomedical scientists is to devise methods for protecting spaceflight crews from these atrophic changes; such protection would allow for longer and more extensive spaceflights.

manned↗

Artificial dexterous hand

An artificial dexterous hand is provided for conformally engaging and manipulating objects. The hand includes an articulated digit which is connected to an engagement sub-assembly and has a first shape adaption mechanism associated with it. The digit has a digit base and first and second phalanges. The digit base is operatively interconnected to the first phalange by a base joint having a base pulley. The phalanges are operatively interconnected by a separate first phalange joint having a first phalange pulley. The engagement sub-assembly includes a tendon, which is received by the base pulley and by the first phalange pulley, and an actuation device for selectively tensioning the tendon. The first shape adaption mechanism is responsive to and receives the tendon. It is also situated between the base joint and the first phalange joint and is connected to the first phalange. Upon actuation by the actuation device, the phalanges are caused to pivot relative to the base joint and the second phalange is caused to pivot relative to the first phalange. At the same time, the first shape adaption mechanism controls the sequence of the aforementioned pivoting of the phalanges through application of braking force to the tendon.

Lee, Sukhan↗

Robotic Arm Comprising Two Bending Segments

The figure shows several aspects of an experimental robotic manipulator that includes a housing from which protrudes a tendril- or tentacle-like arm 1 cm thick and 1 m long. The arm consists of two collinear segments, each of which can be bent independently of the other, and the two segments can be bent simultaneously in different planes. The arm can be retracted to a minimum length or extended by any desired amount up to its full length. The arm can also be made to rotate about its own longitudinal axis. Some prior experimental robotic manipulators include single-segment bendable arms. Those arms are thicker and shorter than the present one. The present robotic manipulator serves as a prototype of future manipulators that, by virtue of the slenderness and multiple- bending capability of their arms, are expected to have sufficient dexterity for operation within spaces that would otherwise be inaccessible. Such manipulators could be especially well suited as means of minimally invasive inspection during construction and maintenance activities. Each of the two collinear bending arm segments is further subdivided into a series of collinear extension- and compression-type helical springs joined by threaded links. The extension springs occupy the majority of the length of the arm and engage passively in bending. The compression springs are used for actively controlled bending. Bending is effected by means of pairs of antagonistic tendons in the form of spectra gel spun polymer lines that are attached at specific threaded links and run the entire length of the arm inside the spring helix from the attachment links to motor-driven pulleys inside the housing. Two pairs of tendons, mounted in orthogonal planes that intersect along the longitudinal axis, are used to effect bending of each segment. The tendons for actuating the distal bending segment are in planes offset by an angle of 45 from those of the proximal bending segment: This configuration makes it possible to accommodate all eight tendons at the same diameter along the arm. The threaded links have central bores through which power and video wires can be strung (1) from a charge-coupled-device camera mounted on the tip of the arms (2) back along the interior of the arm into the housing and then (3) from within the housing to an external video monitor.

Mehling, Joshua S.↗

Human grasp assist device and method of use

A grasp assist device includes a glove portion having phalange rings, contact sensors for measuring a grasping force applied by an operator wearing the glove portion, and a tendon drive system (TDS). The device has flexible tendons connected to the phalange rings for moving the rings in response to feedback signals from the sensors. The TDS is connected to each of the tendons, and applies an augmenting tensile force thereto via a microcontroller adapted for determining the augmenting tensile force as a function of the grasping force. A method of augmenting a grasping force of an operator includes measuring the grasping force using the sensors, encoding the grasping force as the feedback signals, and calculating the augmenting tensile force as a function of the feedback signals using the microcontroller. The method includes energizing at least one actuator of a tendon drive system (TDS) to thereby apply the augmenting tensile force.

Linn, Douglas Martin↗

Human Grasp Assist Device Soft Goods

A grasp assist system includes a glove and a flexible sleeve. The glove includes a digit such as a finger or thumb, a force sensor configured to measure a grasping force applied to an object by an operator wearing the glove, and adjustable phalange rings positioned with respect to the digit. A saddle is positioned with respect to the finger. A flexible tendon is looped at one end around the saddle. A conduit contains the tendon. A conduit anchor secured within a palm of the glove receives the conduit. The sleeve has pockets containing an actuator assembly connected to another end of the tendon and a controller. The controller is in communication with the force sensor, and calculates a tensile force in response to the measured grasping force. The controller commands the tensile force from the actuator assembly to tension the tendon and thereby move the finger.

Ihrke, Chris A.↗

Control of a Glove-Based Grasp Assist Device

A grasp assist system includes a glove and sleeve. The glove includes a digit, i.e., a finger or thumb, and a force sensor. The sensor measures a grasping force applied to an object by an operator wearing the glove. The glove contains a tendon connected at a first end to the digit. The sleeve has an actuator assembly connected to a second end of the tendon and a controller in communication with the sensor. The controller includes a configuration module having selectable operating modes and a processor that calculates a tensile force to apply to the tendon for each of the selectable operating modes to assist the grasping force in a manner that differs for each of the operating modes. A method includes measuring the grasping force, selecting the mode, calculating the tensile force, and applying the tensile force to the tendon using the actuator assembly.

Bergelin, Bryan J↗

Electron Beam Irradiated Intercalated CNT Yarns For Aerospace Applications

Multi-walled CNT yarns have been experimentally and commercially created to yield lightweight, high conductivity fibers with good tensile properties for application as electrical wiring and multifunctional tendons. Multifunctional tendons are needed as the cable structures in tensegrity robots for use in planetary exploration. These lightweight robust tendons can provide mechanical strength for movement of the robot in addition to power distribution and data transmission. In aerospace vehicles, such as Orion, electrical wiring and harnessing mass can approach half of the avionics mass. Use of CNT yarns as electrical power and data cables could reduce mass of the wiring by thirty to seventy percent. These fibers have been intercalated with mixed halogens to increase their specific electrical conductivity to that near copper. This conductivity, combined with the superior strength and fatigue resistance makes it an attractive alternative to copper for wiring and multifunctional tendon applications. Electron beam irradiation has been shown to increase mechanical strength in pristine CNT fibers through increased cross-linking. Both pristine and intercalated CNT yarns have been irradiated using a 5-megavolt electron beam for various durations and the conductivities and tensile properties will be discussed. Structural information obtained using a field emission scanning electron microscope, energy dispersive X-ray spectroscopy (EDS), and Raman spectroscopy will correlate microstructural details with bulk properties.

electrical wiring↗

TIEG1-null tenocytes display age-dependent differences in their gene expression, adhesion, spreading and proliferation properties

The remodeling of extracellular matrix is a crucial mechanism in tendon development and the proliferation of fibroblasts is a key factor in this process. The purpose of this study was to further elucidate the role of TIEG1 in mediating important tenocyte properties throughout the aging process. Wildtype and TIEG1 knockout tenocytes adhesion, spreading and proliferation were characterized on different substrates (fibronectin, collagen type I, gelatin and laminin) and the expression levels of various genes known to be involved with tendon development were analyzed by RT-PCR. The experiments revealed age-dependent and substrate-dependent properties for both wildtype and TIEG1 knockout tenocytes. Taken together, our results indicate an important role for TIEG1 in regulating tenocytes adhesion, spreading, and proliferation throughout the aging process. Understanding the basic mechanisms of TIEG1 in tenocytes may provide valuable information for treating multiple tendon disorders.

60 APPLIED LIFE SCIENCES↗

A synthetic mechano-growth factor E peptide promotes rat tenocyte migration by lessening cell stiffness and increasing F-actin formation via the FAK-ERK1/2 signaling pathway

Tendon injuries are common in sports and are frequent reasons for orthopedic consultations. The management of damaged tendons is one of the most challenging problems in orthopedics. Mechano-growth factor (MGF), a recently discovered growth repair factor, plays positive roles in tissue repair through the improvement of cell proliferation and migration and the protection of cells against injury-induced apoptosis. However, it remains unclear whether MGF has the potential to accelerate tendon repair. We used a scratch wound assay in this study to demonstrate that MGF-C25E (a synthetic mechano-growth factor E peptide) promotes the migration of rat tenocytes and that this promotion is accompanied by an elevation in the expression of the following signaling molecules: focal adhesion kinase (FAK) and extracellular signal regulated kinase1/2 (ERK1/2). Inhibitors of the FAK and ERK1/2 pathways inhibited the MGF-C25E-induced tenocyte migration, indicating that MGF-C25E promotes tenocyte migration through the FAK-ERK1/2 signaling pathway. The analysis of the mechanical properties showed that the Young's modulus of tenocytes was decreased through treatment of MGF-C25E, and an obvious formation of pseudopodia and F-actin was observed in MGF-C25E-treated tenocytes. The inhibition of the FAK or ERK1/2 signals restored the decrease in Young's modulus and inhibited the formation of pseudopodia and F-actin. Overall, our study demonstrated that MGF-C25E promotes rat tenocyte migration by lessening cell stiffness and increasing pseudopodia formation via the FAK-ERK1/2 signaling pathway. - Highlights: • Mechano-growth factor E peptide (MGF-C25E) promotes migration of rat tenocytes. • MGF-C25E activates the FAK-ERK1/2 pathway in rat tenocytes. • MGF-C25E induces the actin remodeling and the formation of pseudopodia, and decreases the stiffness in rat tenocytes. • MGF-C25E promotes tenocyte migration via altering stiffness and forming pseudopodia by the activation of the FAK-ERK1/2 pathway.

60 APPLIED LIFE SCIENCES↗

Cyclic tensile strain enhances human mesenchymal stem cell Smad 2/3 activation and tenogenic differentiation in anisotropic collagen-glycosaminoglycan scaffolds

Orthopaedic injuries, particularly those involving ligaments and tendons, are some of the most commonly treated ailments in the United States and are associated with both high costs and poor outcomes. Regenerative medicine strategies for tendon injuries could be enhanced by three-dimensional biomaterials that can promote cell alignment and pro-tenogenic differentiation of patientderived MSCs. We have previously described a collagenglycosaminoglycan (CG) scaffold possessing aligned structural features able to promote bone marrow MSC differentiation towards a tenogenic lineage, in the absence of growth factor supplementation. We aimed to employ a bioreactor to enhance MSC tenogenic differentiation within the aligned CG scaffold via cyclic tensile strain (CTS), and further to evaluate the relative effects of strain cycle duration and extended application of repeated cycles of CTS on MSC response. Human MSCs were cultured in CG scaffolds for up to 6 d under static (unloaded) or cyclic tensile strain (1 Hz) for 10 min every 6 h. Time-dependent activation of ERK 1/2 and p38 mechanotransduction pathways was observed within each 6 h strain cycle. MSCs remained viable throughout the experiment and application of CTS robustly upregulated the expression of tendon-specific extracellular matrix proteins and phenotypic markers. Simultaneously, CTS promoted increased phosphorylation of Smad 2/3, suggesting a link between tensile stimulation and TGF-β family growth factor production. Together, we demonstrated the design, fabrication and validation of a high-throughput tensile stimulation bioreactor to increase MSC tenogenic differentiation in porous CG scaffolds.

59 BASIC BIOLOGICAL SCIENCES↗

Effects of spaceflight on rhesus quadrupedal locomotion after return to 1G

Effects of spaceflight on Rhesus quadrupedal locomotion after return to 1G. Locomotor performance, activation patterns of the soleus (Sol), medial gastrocnemius (MG), vastus lateralis (VL), and tibialis anterior (TA) and MG tendon force during quadrupedal stepping were studied in adult Rhesus before and after 14 days of either spaceflight (n = 2) or flight simulation at 1G (n = 3). Flight simulation involved duplication of the spaceflight conditions and experimental protocol in a 1G environment. Postflight, but not postsimulation, electromyographic (EMG) recordings revealed clonus-like activity in all muscles. Compared with preflight, the cycle period and burst durations of the primary extensors (Sol, MG, and VL) tended to decrease postflight. These decreases were associated with shorter steps. The flexor (TA) EMG burst duration postflight was similar to preflight, whereas the burst amplitude was elevated. Consequently, the Sol:TA and MG:TA EMG amplitude ratios were lower following flight, reflecting a "flexor bias." Together, these alterations in mean EMG amplitudes reflect differential adaptations in motor-unit recruitment patterns of flexors and extensors as well as fast and slow motor pools. Shorter cycle period and burst durations persisted throughout the 20-day postflight testing period, whereas mean EMG returned to preflight levels by 17 days postflight. Compared with presimulation, the simulation group showed slight increases in the cycle period and burst durations of all muscles. Mean EMG amplitude decreased in the Sol, increased in the MG and VL, and was unchanged in the TA. Thus adaptations observed postsimulation were different from those observed postflight, indicating that there was a response unique to the microgravity environment, i.e., the modulations in the nervous system controlling locomotion cannot merely be attributed to restriction of movement but appear to be the result of changes in the interpretation of load-related proprioceptive feedback to the nervous system. Peak MG tendon force amplitudes were approximately two times greater post- compared with preflight or presimulation. Adaptations in tendon force and EMG amplitude ratios indicate that the nervous system undergoes a reorganization of the recruitment patterns biased toward an increased recruitment of fast versus slow motor units and flexor versus extensor muscles. Combined, these data indicate that some details of the control of motor pools during locomotion are dependent on the persistence of Earth's gravitational environment.

Bion 11 Project↗

Strong tough hydrogels via the synergy of freeze-casting and salting out

Natural load-bearing materials like tendons possess high water content of ~70% but14 are still strong and tough even when used for over 1 million cycles per year, which is owed to the hierarchical assembly of anisotropic structures across multi-length-scales . In imitation of natural systems, various hydrogels have been created via methods like electro-spinning, extrusion, compositing, freeze casting, self-assembly, and mechanical stretching for improved mechanical performance. However, in contrast to tendons, many hydrogels with the same high water content do not show high strength, large toughness or high fatigue resistance. In this work, we present a strategy to produce strong, tough and fatigue resistant hydrogels with multi-length-scale hierarchical architecture using a freezing-assisted salting-out treatment. The produced exemplary poly(vinyl alcohol) hydrogels are highly anisotropic, comprising micrometer-scale honeycomb-like pore walls, which in turn comprise interconnected nanofibrils meshes, entirely physically assembled from polymer chains. These hydrogels are made of 70-95% water but can exhibit ultra-high ultimate stress (23.5 ± 2.7 MPa) and strain (2900 ± 450%), giant 32226 toughness (210 ± 13 MJ/m , 175 ± 8 kJ/m) and remarkable fatigue threshold (10.5 ± 1.3 kJ/m), which are 10 times tougher than natural tendon. The presented strategy could expand the applicability of weak polymeric material, like hydrogels, in practical applications that requires long-term services with high-loads and abrupt-impacts and extend the development of structural hydrogels.

36 MATERIALS SCIENCE↗

The 3-D vision system integrated dexterous hand

Most multifingered hands use a tendon mechanism to minimize the size and weight of the hand. Such tendon mechanisms suffer from the problems of striction and friction of the tendons resulting in a reduction of control accuracy. A design for a 3-D vision system integrated dexterous hand with motor control is described which overcomes these problems. The proposed hand is composed of three three-jointed grasping fingers with tactile sensors on their tips, a two-jointed eye finger with a cross-shaped laser beam emitting diode in its distal part. The two non-grasping fingers allow 3-D vision capability and can rotate around the hand to see and measure the sides of grasped objects and the task environment. An algorithm that determines the range and local orientation of the contact surface using a cross-shaped laser beam is introduced along with some potential applications. An efficient method for finger force calculation is presented which uses the measured contact surface normals of an object.

Luo, Ren C.↗

Mineralization of collagen may occur on fibril surfaces: evidence from conventional and high-voltage electron microscopy and three-dimensional imaging

The interaction between collagen and mineral crystals in the normally calcifying leg tendons from the domestic turkey, Meleagris gallopavo, has been investigated at an ultrastructural level with conventional and high-voltage electron microscopy, computed tomography, and three-dimensional image reconstruction methods. Specimens treated by either aqueous or anhydrous techniques and resin-embedded were appropriately sectioned and regions of early tendon mineralization were photographed. On the basis of individual photomicrographs, stereoscopic pairs of images, and tomographic three-dimensional image reconstructions, platelet-shaped crystals may be demonstrated for the first time in association with the surface of collagen fibrils. Mineral is also observed in closely parallel arrays within collagen hole and overlap zones. The mineral deposition at these spatially distinct locations in the tendon provides insight into possible means by which calcification is mediated by collagen as a fundamental event in skeletal and dental formation among vertebrates.

NASA Discipline Musculoskeletal↗

Human Grasp Assist Device With Exoskeleton

A grasp assist system includes a glove, actuator assembly, and controller. The glove includes a digit, i.e., a finger or thumb, and a force sensor. The sensor measures a grasping force applied to an object by an operator wearing the glove. Phalange rings are positioned with respect to the digit. A flexible tendon is connected at one end to one of the rings and is routed through the remaining rings. An exoskeleton positioned with respect to the digit includes hinged interconnecting members each connected to a corresponding ring, and/or a single piece of slotted material. The actuator assembly is connected to another end of the tendon. The controller calculates a tensile force in response to the measured grasping force, and commands the tensile force from the actuator assembly to thereby pull on the tendon. The exoskeleton offloads some of the tensile force from the operator's finger to the glove.

Bergelin, Bryan J↗

ATHLETE Offloader Limb as a High-capacity Crane

A new concept for the NASA Jet Propulsion Laboratory (JPL) All-Terrain Hex-Limbed Extra-Terrestrial Explorer (ATHLETE) robotic constructor / mobility system employs tendon-driven actuation of individual limbs, similar to high-capacity cranes in terrestrial work environments, that can offload cargo from tall landers. While maintaining mechanical joints that allow each limb to function as a highly dexterous multi-Degree-Of-Freedom (DOF) robotic arm, tendon-driven truss sections increase the capacity of moment loads for extended configurations of the limb. The tendon-driven crane-like limb will be capable of offloading cargo from tall landers such as the SpaceX Starship. This paper describes the structural analysis, operations, calibration, and actuation of limbs designed to address specific target load cases that might be required for human exploration missions on planetary surfaces.

Wilcox, Brian↗

The Use of Ultrasound-Guided Injections for Tendinopathies

Purpose of Review: The purpose of the study was to review the efficacy and safety of common ultrasound-guided injections for tendinopathy conditions. Corticosteroid injections have historically been the most common injection used for tendinopathy; however, there are an increasing number of injections including platelet-rich plasma, hyaluronan, polidocanol, botulinum toxin, and high volume saline injections. Recent Findings: There is growing evidence that while corticosteroid injections for tendinopathies usually have short-term efficacy, they may result in medium-term harm, particularly for tennis elbow (lateral epicondylitis). Corticosteroid injections appear to have more clinical utility for tenosynovitis conditions. There is insufficient evidence regarding other injection options to make a broad recommendation in favour, although individual trials for certain tendons illustrate benefits for some of the non-corticosteroid options. Summary: When considering the use of ultrasound-guided corticosteroid injections for tendinopathies, the risk of possible medium-term harm must be weighed up against any short-term efficacy. Other injection-based therapies may be appropriate in certain clinical situations; however, the evidence and clinical circumstances must be considered for the particular tendon and patient. Load-based rehabilitation remains the cornerstone of tendinopathy management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗