Engineering PapersSearch

SEARCH · Engineering Papers

Results for “TEMPERATURE PROFILE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Thermal and Well Flow Performance of Closed-Loop Geothermal in the Wattenberg Area

Closed-loop geothermal systems provide an alternative to resource-constrained hydrothermal systems and stimulation-intensive enhanced geothermal systems. In this work, we apply the slender-body theory (SBT) model, to simulate the well flow and heat transfer performance of U-loop well designs in the Wattenberg area of the Denver-Julesburg Basin. Three U-loop well patterns are investigated, including a single-, double-, and multi-lateral design. The subsurface within the area of interest is characterized by deep, hot (> 200 degrees C) igneous/metamorphic basement rock underlying multiple sedimentary formations. The lateral section(s) of the U-loop lie(s) within a target depth of 6 km, where temperatures are estimated to approach 300 degrees C. As a base case, conduction-only heat transfer is investigated through simulations with the SBT model within U-loops with open-hole laterals that exchange heat directly with the hot, dry rock using water as a working fluid. The utilization of supercritical CO2 as a heat transfer fluid is also considered. For each scenario, the system performance in terms of annual heat production and temperature profile over a 20-year project lifetime are assessed. Also, the levelized costs of heat and electricity (LCOH and LCOE) are determined using a top-down techno-economic analysis model. The results show that the performance- and cost-optimized U-loop design is one having an injection-production well spacing of 1,000 meters with ten 50-meter-spaced laterals that traverse a subsurface system with a temperature gradient of 60 degrees C/km. By injecting 20 degrees C-water at a rate of 60 kg/s through this loop, an average heat production of 19 MWth (i.e., 2.2 MWe net plant output) can be achieved, resulting in an LCOE and LCOH of $136/MWhe and $1.53/GJ, respectively, over a 20-year project life.

closed-loop geothermal

The scoping, design, and plasma physics optimization of the Eos neutron source stellarator

On the path to a fusion pilot plant, Thea Energy plans to build Eos, a sub-breakeven, deuterium-deuterium, beam-target fusion, stellarator neutron source facility for producing tritium and other valuable radioisotopes. In this paper, a set of 1D plasma physics models are coupled and used to design the operating point of the facility and predict performance. At this foundational stage of the design, analytic and approximate models are sufficient to capture the leading-order effects, and fast enough to run in the inner loop of an optimizer. Higher-fidelity analyses will follow. Models of 1D profile-dependent neutral beam stopping, ion beam slowing down, beam-target fusion, electron-ion classical heat transfer, energy confinement (ISS04), beam pressure, beam heating of ions and electrons, beam-beam fusion fraction, and neutral beam injection and gyrotron heating electrical efficiencies are included. A numerical optimizer is used to determine the minimum required facility electric power to generate tritium at a given rate. A potentially advantageous regime is described in which modern precisely-quasisymmetric stellarators, new high-temperature superconductors, ITER-derived neutral beam injection, and new high-frequency gyrotrons enable a suitible target plasma with hot electrons, cold ions, peaked density and temperature profiles, and high beam-injected ion density. It appears possible at this time for a facility with a medium-scale and medium-strength stellarator whose required facility electric power is less than 40 MW to produce $2.5\times 10^{17}$ neutrons s -1 for the production of radioisotopes. With the addition of a tritium breeding blanket, such a facility could produce 0.2 grams d -1 or 70 grams yr -1 of tritium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Distributed Sensors for Waste Plastics Gasification and Clean Hydrogen Productions

This project developed distributed fiber sensors for plastics gasification reactor for clean hydrogen production. These sensors can be directly inserted into gasification reactors to perform real-time, in-situ hydrogen and temperature profile measurements with 5-cm spatial resolution across the entire reactor chamber. Our research team will use this new sensor capability to study how feedstock mixtures, feedstock preparations, and air/steam flows impact feedstock consumption, hydrogen production, and harmful chemical production emissions.

08 HYDROGEN

Dynamic Control of Sodium Cold Trap Purification Temperature Using LSTM System Identification

This study investigates the dynamic regulation of the sodium cold trap purification temperature at Argonne National Laboratory’s liquid sodium test facility, employing long short-term memory (LSTM) system identification techniques. The investigation introduces an innovative hybrid approach by integrating model predictive control (MPC) based on first principles dynamic models with a multi-step time–frequency LSTM model in predicting the temperature profiles of a sodium cold trap purification system. The long short-term memory–model predictive controller (LSTM-MPC) model employs a sliding window scheme to gather training samples for multi-step prediction, leveraging historical data to construct predictive models that capture the non-linearities of the complex system dynamics without explicitly modeling the underlying physical processes. The performance of the LSTM-MPC and MPC were evaluated through simulation experiments, where both models were assessed on their capacity to maintain the cold trap temperature within predefined set-points while minimizing deviations and overshoots. Results obtained show how the data-driven LSTM-MPC model demonstrates stability and adaptability. In contrast, the traditional MPC model exhibits irregularities, particularly evident as overshoots around set-point limits, which can potentially compromise its effectiveness over long prediction time intervals. The findings obtained offer valuable insights into integrating data-driven techniques for enhancing real-time monitoring systems.

LSTM-MPC

Data & Code from Phoenix CPPP Phase 2 Analysis

This data and code package supports the analysis presented in “Beyond Surface Cooling: Comprehensive Field Assessment of Reflective Pavement Thermal Performance in Phoenix, Arizona” and provides fully reproducible workflows for evaluating the thermal performance of cool pavement treatments in a hot urban environment. The dataset integrates multi-modal field measurements collected across residential and nonresidential settings, including mobile air temperature traverses, stationary air temperature monitoring, residential mean radiant temperature (MRT) measurements, subsurface temperature profiles, and controlled testbed observations. The data package contains raw and processed datasets in comma-separated value (CSV) format, accompanying metadata files describing site characteristics and measurement protocols, and R scripts (.R files) used for data cleaning, time synchronization, spatial and temporal matching, quality control filtering, statistical comparison, and figure generation. All analyses were conducted using R (version ≥ 4.2.0) with commonly available packages (e.g., tidyverse, lubridate, data.table, ggplot2). No proprietary software is required to reproduce results. Field campaigns were designed to quantify the effects of high-reflectance pavement coatings on surface temperature, near-surface air temperature, subsurface heat propagation, and radiative heat exposure. Temporal alignment procedures include standardized timestamp conversion and nearest-neighbor matching of high-frequency sensor measurements to stop-based metadata within defined tolerance windows to ensure comparability across instruments. The workflows generate summary statistics, treatment–control contrasts, depth-dependent thermal gradients, and time-series visualizations used in the associated publication. By integrating mobile, stationary, radiative, and subsurface measurements within a unified and transparent processing framework, this package enables comprehensive evaluation of cool pavement performance across multiple thermal exposure pathways and supports reuse in future urban heat mitigation and climate resilience studies.

AIR TEMPERATURE

"Source Term Modeling for Advanced Gas Micro-Reactors"

Maintaining the safety of the public, environment, and operating personnel is the most important factor in designing, operating, maintaining, and decommissioning nuclear reactors. In recent years, there has been a growing interest in the development of micro-reactors employing TRi-structural ISOtropic (TRISO)-coated particle fuel. In gas reactors, TRISO fuel plays an important role in the safety case for high temperature reactors because of the fission product retention properties of the fuel. This ability enables the use of a functional containment strategy for the reactor where multiple barriers are used to prevent fission product release to the environment. Part of the safety analysis of these advanced reactors is the assessment of radionuclide releases under normal and accident conditions through the multiple credited safety barriers. Using conservative assumptions, a mechanistic analysis can be performed to quantify these releases that combines the probabilistic assessment of failure with analytic solutions to radionuclide transport equations. Source term modeling for TRISO fuel has been performed for previous reactor designs; however, these models are outdated, in many cases proprietary, and need updates to be applied to the current state of TRISO fuel technology and alternative gas reactor core configurations [1]. Currently, the only publicly available source term assessment for gas reactors is an expert-based Monte Carlo simulation based on the effectiveness of the fuel kernel, coating layers, and graphite block in a modular high temperature gas reactor [2]. Thus, there is a need to develop a simple, versatile, and mechanistic model of fission product release and transport in gas reactor cores that could be applied to a variety of reactors through user inputs and reactor-specific radionuclide inventories. The release is calculated by the diffusion of the key safety important fission products through the kernel, silicon carbide (SiC), graphite for both intact and defective TRISO particles based on fuel and graphite temperatures in the reactor under normal operation. These releases from the fuel enter the coolant where they can plate-out on cooler surfaces. A clean-up model is included for designs with a coolant purification system to remove fission gases. This initial distribution of fission products in the reactor serves as an initial condition for potential releases under postulated accident conditions. The model then can calculate the fission product release for any transient temperature profile and fission product releases can then be used to assess radiological dose to the workers and the public using conventional dose tools. Data on the diffusion of fission products is based on historic German TRISO experiments and the more current Department of Energy (DOE) Advanced Gas Reactor (AGR) TRISO fuel development program. The model is coded in python with inputs and outputs in excel spreadsheets, as well as python plotting utilities to aid in the interpretation of the results. References: [1] INL, NGNP Mechanistic Source Term White Paper, INL-10-17997, July 2010. [2] David A. Petti, Richard R. Hobbins, Peter Lowry, Hans Gougar, “Representative Source Terms and The Influence of Reactor Attributes on Functional Containment in Modular High Temperature Gas-cooled Reactors,” Nuclear Technology, Vol. 184, p. 181-197, Nov. 2013.

07 ISOTOPE AND RADIATION SOURCES

Irradiation Testing of Ultrasonic Transducers

Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of numerous parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of single, small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of existing knowledge of ultrasonic transducer material survivability under irradiation conditions. To address this need, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate promising magnetostrictive and piezoelectric transducer performance in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2 (E> 0.1 MeV). This test will be an instrumented lead test; and real-time transducer performance data will be collected along with temperature and neutron and gamma flux data. By characterizing magnetostrictive and piezoelectric transducer survivability during irradiation, test results will enable the development of novel radiation tolerant ultrasonic sensors for use in Material and Test Reactors (MTRs). The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers

Daw, J.

Ultrasonic Transducer Irradiation Test Results

Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. These efforts are limited by the lack of identified ultrasonic transducer materials capable of long term performance under irradiation test conditions. To address this need, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate the performance of promising magnetostrictive and piezoelectric transducers in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2 . A multi-National Laboratory collaboration funded by the Nuclear Energy Enabling Technologies Advanced Sensors and Instrumentation (NEET ASI) program also provided initial support for this effort. This irradiation, which started in February 2014, is an instrumented lead test and real-time transducer performance data are collected along with temperature and neutron and gamma flux data. The irradiation is ongoing and will continue to approximately mid-2015. To date, very encouraging results have been attained as several transducers continue to operate under irradiation.

Daw, Joshua

Optically multiplexed neutron time-of-flight technique for inertial confinement fusion

Neutron time-of-flight (nTOF) detectors are crucial in diagnosing the performance of inertial confinement fusion (ICF) experiments, which implode targets of deuterium–tritium fuel to achieve thermonuclear conditions. These detectors utilize the fusion neutron energy spectrum to extract key measurements, including the hotspot ion temperature and fuel areal density. Previous work [Danly et al., Rev. Sci. Instrum. 94, 043502 (2023)] has demonstrated adding 1D spatial resolution to an nTOF-like detector using a neutron aperture and streak camera to measure the ion temperature profile of an ICF implosion. By contrast, the study presented herein explores modifying the 1D detector to use a fast photomultiplier tube (PMT) to validate the design of a 2D spatially resolved instrument based on reconstruction from 1D profiles. The modification would collect time-of-flight traces from separate scintillators in an imaging array with one PMT using optical fibers of varying lengths to time-multiplex the signals. This technique has been demonstrated in ride-along experiments on the OMEGA laser with 20 fiber-coupled scintillator channels connected to a Photek PMT210. Results provide constraints on the fiber lengths and PMT gating requirements to promote pulse fidelity throughout all channels. Calibration of the detector to fixed nTOFs can provide a preliminary estimate of the instrument response function (IRF), although measurement of the IRF is currently under way. These results suggest that nTOF signals can potentially be time-multiplexed with fibers so long as the design is strategic to mitigate signal-to-noise reduction, modal dispersion, and charge build-up in the PMT, which has implications beyond ion temperature imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Effects of break geometry and orientation on helium-air mixing in simulated reactor cavities of high temperature gas reactors

Here, this study experimentally examined the spatial and temporal variations in air and helium concentrations and temperature fields within simulated reactor cavities of a High Temperature Gas Reactor (HTGR) following helium discharge into an initially air-filled reactor cavity system. Detailed temperature maps were generated using a combination of fiber optics temperature sensor and multiple thermocouple probes within the simulated reactor cavities. The research scenario involved a hypothetical small pipe break in the Reactor Pressure Vessel, resulting in the release of high-temperature helium into the surrounding cavity. A scaled multi-compartment experimental facility, modeled after the General Atomics Modular High Temperature Gas Reactor (GA-MHTGR) design, was constructed for helium and air mixing experiments. Oxygen sensors and thermocouple probes were installed in all five cavities to measure the concentrations of oxygen (or helium) and the temperature distributions of the gas mixture. The experimental findings highlighted the significant impact of the injected helium jet velocity on the gas mixing process and demonstrated how the direction of the helium jet influences the air-helium temperature profiles within the cavities.

Air-ingress

Electron cyclotron emission measurements and modeling in optically semi-transparent plasma on the HSX stellarator

On the Helically Symmetric Experiment (HSX), electron cyclotron emission (ECE) at the second harmonic of the electron gyrofrequency is measured with a 16-channel heterodyne receiver. An ECE radiometer diagnostic has been calibrated with a broadband frequency source, allowing independent measurements of the electron temperature. The antenna pattern has a significant impact on the measurements, and modeling its effect is necessary to produce an ECE radiation temperature spectrum. Measurements, calibration results, and modeling of the ECE data are presented in this paper. At a relatively high plasma density, HSX plasmas are thermal, and the radiation temperature measured by the radiometer is in good agreement with the electron temperature measured by a Thomson scattering diagnostic. At a relatively low plasma density, the deviation from a Maxwellian distribution is large, and asymmetry in the radiation temperature profile is measured. These measurements are supported by single-pass and multi-pass ray tracing calculations of the electron cyclotron emission using the TRAVIS ray tracing code. Thermal and nonthermal electron populations exist in HSX, and the effect of these populations on the asymmetry in the measured emission is presented.

Cyclotron radiation

A Green's Function Wind Turbine Induction Model That Incorporates Complex Inflow Conditions

ABSTRACT In this work, we develop a new analytical turbine induction model that can incorporate complex inflow conditions including cases where the wind velocity and temperature profiles can vary as functions of height. This induction model is derived from the linearized Navier–Stokes and leads to a second‐order ODE that can be solved using a Green's function formulation. The corresponding Green's function for several configurations are found including the infinite domain, semi‐infinite domain with ground plane, and a power law velocity inflow profile. The results of this approach are then compared with simulations of the turbine induction field using the AMR‐Wind CFD solver with a uniformly loaded actuator disk model. These comparisons show that the Green's function approach captures the centerline blockage, three‐dimensional blockage flow field, and streamwise velocity slow down, with very good agreement for lower thrust conditions and at larger distances away from rotor disk. The effects of shear on the turbine blockage were also compared using a power law inflow profile, and we show that this approach matches the CFD predictions for the cases considered.

17 WIND ENERGY

An iterative bidirectional gradient boosting approach for CVR baseline estimation

Here this paper presents a novel Iterative Bidirectional Gradient Boosting Model (IBi-GBM) for estimating the baseline of Conservation Voltage Reduction (CVR) programs. In contrast to many existing methods, we treat CVR baseline estimation as a missing data retrieval problem. The approach involves dividing the load and its corresponding temperature profiles into three periods: pre-CVR, CVR, and post-CVR. To restore the missing load profile during the CVR period, the method employs a three-step process. First, a forward-pass GBM is executed using data from the pre-CVR period as inputs. Subsequently, a backward-pass GBM is applied using data from the post-CVR period. The two restored load profiles are reconciled, considering pre-calculated weights derived from forecasting accuracy, and only the leftmost and rightmost points are retained. The newly restored points are then included as inputs for the subsequent iteration. This iterative procedure continues until the original load data in the CVR period is fully restored. We develop IBi-GBM using actual smart meter and Supervisory Control and Data Acquisition (SCADA) data. Our results demonstrate that IBi-GBM exhibits robust performance across various data resolutions and in different seasons and outperforms existing methods by achieving a 1-2% reduction in normalized Root Mean Square Error (nRMSE).

42 ENGINEERING

Optimization of direct air capture processes using reactive transport models of adsorption-desorption cycles

In this study, we develop and implement a reactive transport model in COMSOL Multiphysics® to address the challenges of direct air carbon capture. The model is validated against experimental data and used to simulate the cyclic steady state of the adsorption-desorption process. The optimization of this model is achieved through advanced trust-region methods integrated with Gaussian Processes. Key decision variables, including adsorption and desorption times, desorption temperature and pressure, input velocity, bed porosity, column length, and radius were optimized to minimize the capture cost. After optimization, a sensitivity analysis revealed the complex interplay between the decision variables and their effect on the specific energy and cost of removing the CO 2 . We optimized the capture cost while taking into account the trade-off between energy consumption and productivity. The resulting minimum capture cost was determined to be 265.2 $/t-CO 2 , which aligns with expected values reported in the literature. Numerical results suggest the effectiveness of the optimization strategies applied, and underscore the importance of simultaneous decision variable selection in improving the performance in direct air capture processes. We also extend the modeling approach to a 2D axisymmetric model to better visualize CO₂ uptake and temperature profiles, revealing significant radial gradients during the regeneration step. As a main drawback, this enhanced model comes with a computational cost approximately 40 times higher than that of the 1D model.

Adsorption-desorption process

Long-Term field testing of the accuracy and HVAC energy savings potential of occupancy presence sensors in A Single-Family home

The energy-saving potential of occupancy-centric smart thermostats has been extensively explored in simulations but lacked field testing for energy savings quantification and sensor performance assessment in real buildings. This paper presents a long-term field study conducted in a single-family home in Texas, U.S. to evaluate the performance of occupancy-centric controls (OCC) of HVAC (heating, ventilation, and air-conditioning) system in terms of energy savings, sensor accuracy, and impact on electric peak demand. The test site was equipped with a commercial off-the-shelf (COTS) smart thermostat and multiple occupancy presence sensors for OCC implementation. Additionally, a sub-metering system was installed to monitor electricity consumption of various end-use equipment, including the HVAC system. A supplementary device was installed to track the ground-truth occupancy for the accuracy evaluation of the occupancy presence sensor. Scenarios of baseline and OCC controls were alternated weekly over the 20-month testing period. The results indicated an effective OCC execution, as evidenced by indoor temperature profiles. During the 2023 cooling season, OCC achieved total energy savings of 1,958 kWh, corresponding to a 17.6% energy savings ratio. Under certain conditions, daily HVAC energy savings reached as high as 17 kWh, with a savings ratio of 35%. Sensor performance showed an overall accuracy of 83.8%, a False Positive Rate (FPR) of 12.8%, and a False Negative Rate (FNR) of 47.4%. A key limitation was the sensor’s inability to detect stationary occupants during sleep, leading to a midnight FNR of nearly 100% and significantly compromising thermal comfort. Additionally, the implementation of OCC resulted in extended periods of high electricity demand on summer afternoons, affecting occupant’s thermal comfort and posing potential challenges to community-level grid operations if OCC were widely adopted. Furthermore, this study addresses a critical research gap by empirically investigating energy-saving potential and occupancy sensor performance in residential buildings. Through a comprehensive field-testing study, the research examines the interrelationship between sensor accuracy, energy savings, and thermal comfort, an area that has received limited attention in the current literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Thermal property characterization of phase change materials in building applications: A systematic review of fundamentals, recent progress, and future directions

Phase change materials (PCMs) can reduce building peak loads and enable demand-responsive thermal energy storage (TES), but their deployment depends on reliable measurement and interpretation of thermal properties across laboratory, intermediate, and application scales. Here, this review systematically examines characterization methods, testing protocols, and recent advances for neat PCMs and PCM composites, emphasizing thermal conductivity, enthalpy-related properties (phase change temperature, latent heat, specific heat), and cycling stability. For thermal conductivity, we compare steady-state and transient techniques and note limitations when phase transition and contact resistance affect measurements. For enthalpy–temperature characterization, we discuss differential scanning calorimetry together with intermediate- and bulk-scale methods, including T-history, heat flow meter testing, and three-layer calorimetry (3LC), to generate application-relevant enthalpy–temperature profiles. Cycling stability is organized into four experimental families: thermoelectric–air, fully thermoelectric, water-bath, and in situ chamber approaches, with attention to separating reversible supercooling from true degradation such as phase segregation. We highlight emerging noncontact diagnostics, including infrared thermography and embedded sensing, for spatially resolved validation and multiscale interpretation. Finally, we review the growing use of AI and machine learning for property prediction, inverse characterization from experimental signals, and real-time state estimation in building-integrated TES. Key needs include harmonized protocols, interlaboratory benchmarking, uncertainty reporting, and metadata-rich datasets to accelerate reproducible PCM qualification for grid-flexible buildings.

AI

Improving the modeling of near-wall interphase heat transfer in porous media models of Pebble Bed Reactors

Here, this work aims to improve capabilities for modeling localized effects in porous media models of Pebble Bed Reactors. The wall-channeling effect is the primary local phenomenon of interest in a PBR, where the presence of the reflector wall disrupts the pebble packing, causing the pebbles near the wall to pack less efficiently and creating large void regions. Accurate modeling of the near-wall region is important as it will affect core bypass flow and temperature predictions. Porous media models are commonly used for design scoping and plant-level simulations of PBRs. Although these models have some capabilities to model the near-wall region, the correlations that are available in porous media codes are often inaccurate when a multi-region model is used to discretize the near-wall region. This work employs a high-to-low analysis to study the accuracy of available interphase heat transfer closures. NekRS, a spectral element computational fluid dynamics code, is used to perform Large Eddy Simulations. These LES simulation results are compared to porous media model results from the Pronghorn porous media code. The friction term of the KTA drag closure is first improved, reducing the error in the prediction of the near-wall velocity from over 50% to less than 5%. This is combined with improvements to the form term from previous works to produce a drag closure that is capable of accurately modeling the wall-channeling effect across a variety of flow conditions. The Nusselt number predictions of several heat transfer correlations are compared to the high-fidelity results where it is found that the KTA heat transfer correlation is capable of accurately predicting the local Nusselt numbers that were determined in the high-fidelity simulation. Comparison of the radial solid temperature profiles, however, reveal discrepancies between NekRS and Pronghorn. It is discovered that the implementation of the interphase heat transfer coefficient that exists in many current porous media codes is not valid when local porosities are modeled. Instead, it is suggested that the interphase heat transfer coefficient should be dependent on the local porosity, the Nusselt number, and the local solid surface-to-volume ratio. Implementation of this change produces improvement in the agreement between the results obtained by NekRS and Pronghorn while using the KTA heat transfer correlation.

interphase heat transfer

In Situ Studies of Copper-Zirconia-Zinc Oxide Model Catalysts for CO 2 Hydrogenation

A combination of in situ X-ray photoelectron spectroscopy (XPS) and infrared reflection absorption spectroscopy (IRAS) was used to investigate the formation of surface intermediates from CO 2 hydrogenation on copper-zirconia-zinc oxide model catalysts under reaction conditions. Copper clusters with different numbers of atoms (n = 1, 4, 13) were deposited onto bare and ZrO 2 -modified ZnO powder supports to systematically examine the effects of Cu cluster size and the synergy between metal and metal-oxide components. Under low pressure CO 2 hydrogenation conditions (CO 2 :H 2 = 1:9, 0.4 mbar, 300–600 K), XPS and IRAS identify the most prominent intermediates as carbonate (CO 3 *), formate (HCOO*) and methoxy (CH 3 O*), which is the final surface-bound intermediate leading to methanol. The temperature profiles are consistent with a mechanism in which CO 2 is adsorbed as carbonate species (HCO 3 *, CO 3 *) followed by hydrogenation reactions to formate (HCOO*) and methoxy (CH 3 O*), but the relative yields strongly depend on surface composition. Specifically, the presence of ZrO 2 promotes CO 2 adsorption and activation and improves the thermal stability of the Cu clusters against loss of surface area. Moreover, the ternary Cu 4 /ZrO 2 /ZnO surface is significantly more active than Cu 4 /ZnO and ZrO 2 /ZnO surfaces for the formation of methoxy (CH 3 O*), indicating that Cu–ZrO 2 interfaces promote the formation of key intermediates leading to methanol. Finally, the yields of intermediates are similar for all Cu cluster sizes (Cu 1 , Cu 4 and Cu 13 ), indicating that the primary role of Cu is to provide H atoms via H 2 dissociation and spillover. In conclusion, these molecular-level insights provide a fundamental understanding of the enhanced efficiency of ternary Cu–ZrO 2 –ZnO catalysts and establish design principles for developing improved catalysts for CO 2 conversion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH