Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TEMPERATURE PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Direct Reconstruction of Ablative Thermal Protection System Aeroheating Using A Green's Function Approach

A Green’s function inverse heat transfer (IHT) approach is used to reconstruct the surface heating conditions on ablative thermal protection system (TPS) materials from embedded heat flux sensor and temperature probe measurements. The approach models the temperature time-history at the measurement location as a discrete linear system, allowing for the heat flux boundary condition to be recovered directly without the need for time-marching schemes. The effects of material decomposition and pyrolysis gas transport are modeled using an energy source/sink analogue. The performance of the reconstruction approach is analyzed on a 1D test case representative of an atmospheric entry heating scenario. The approach can recover the TPS surface heat flux to within 4% of the input heating condition with a computation time of 2-3 seconds (>3 orders of magnitude faster than current time-marching IHT methods). As a byproduct of the surface heating reconstruction, the algorithm also captures the surface pyrolysis gas mass flux and solid decomposition at multiple through-thickness locations within the TPS.

Kenneth McAfee↗

Evaluation of water cooled supersonic temperature and pressure probes for application to 1366 K flows

Water cooled supersonic probes are developed to investigate total pressure, static pressure, and total temperature in high-temperature jet plumes and thereby determine the mean flow properties. Two probe concepts, designed for operation at up to 1366 K in a Mach 2 flow, are tested on a water cooled nozzle. The two probe designs - the unsymmetric four-tube cooling configuration and the symmetric annular cooling design - take measurements at 755, 1089, and 1366 K of the three parameters. The cooled total and static pressure readings are found to agree with previous test results with uncooled configurations. The total-temperature probe, however, is affected by the introduction of water coolant, and effect which is explained by the increased heat transfer across the thermocouple-bead surface. Further investigation of the effect of coolant on the temperature probe is proposed to mitigate the effect and calculate more accurate temperatures in jet plumes.

Lagen, Nicholas↗

The Meteorological Experiment on the Mars Surveyor '98 Polar Lander

When it lands on Mars on December 3, 1999, the Mars Surveyor '98 Mars Polar Lander (MPL) will provide the first opportunity to make in-situ measurements of the near-surface weather climate, and volatile inventory in the Martian south polar region. To make the most of this opportunity, the MPL's Mars Volatiles and Climate Surveyor (MVACS) payload includes the most comprehensive complement of meteorological instruments ever sent to Mars. Like the Viking and the Mars Pathfinder Lander, the MVACS Meteorological (Met) package includes sensors for measuring atmospheric pressures, temperatures, and wind velocities. This payload also includes a 2-channel tunable diode laser spectrometer for in-situ measurements of the atmospheric water vapor abundance near the ground, and improved instruments for measuring the relative abundances of oxygen isotopes (in water vapor and CO2) and a surface temperature probe for measuring the surface and sub-surface temperatures. This presentation will provide a brief overview of the environmental conditions anticipated at the surface in the Martian regions. We will then provide an over-view of the MVACS Met instrument and describe the MET sensors in detail, including their principle of operation, range, resolution, accuracy, sampling strategy, heritage, accommodation on the Lander, and their control and data handling system. Finally, we will describe the operational sequences, resource requirements, and the anticipated data volumes for each of the Met instruments.

Crisp, D.↗

MVACS Robotic Arm

The primary purpose of the Mars Volatiles and Climate Surveyor (MVACS) Robotic Arm is to support to the other MVACS science instruments by digging trenches in the Martian soil; acquiring and dumping soil samples into the thermal evolved gas analyzer (TEGA); positioning the Soil Temperature Probe (STP) in the soil: positioning the Robotic Arm Air Temperature Sensor (RAATS) at various heights above the surface, and positioning the Robotic Arm Camera (RAC) for taking images of the surface, trench, soil samples, magnetic targets and other objects of scientific interest within its workspace.

robotics robotic arm sampling MVACS↗

Analysis of Seed Sanitization, Rapid Freezer Proficiency, and Veg-03 Water Verification

In order to ensure the well-being of astronauts and experiments on the ISS (International Space Station), seeds need to be free of microbes, the rapid freezer needs to be freezing biological samples evenly and proficiently, and the astronauts need to have accurate watering procedures for Veg-03 (the latest Phytotron for the Veggie (Vegetable Production System) project). Seed flight candidates were sanitized with varying levels of HCL in order to determine the right amount to use for future flight experiments, too much HCL and the seeds will not germinate and too little and they will be contaminated with microorganisms. The rapid freezer was assessed using temperature probes to determine if there is a homogeneous change in temperature in order to ensure the safe freezing of biological organisms. The plant watering procedures given to the astronauts were assessed in order to make sure that Veg-03 experiments are receiving the correct amount of water.

Hollingsworth, Savannah↗

Hot-wire probe

High-temperature platinum probe measures turbulence and Reynolds shear stresses in high-temperature compressible flows. Probe does not vibrate at high velocities and does not react like strain gage on warmup.

Mikulla, V.↗

A thermocouple for hot, oxidizing environments

Thermocouple enclosed in nonoxidizing thermally conductive metal provides temperature probe which is made for very hot, highly oxidizing environments. Approach makes temperature measurement in hot, oxidizing atmospheres much easier task.

Jenkins, R. V.↗

Order-disorder in room-temperature ionic liquids probed via methyl quantum tunneling

Room-temperature ionic liquids are promising candidates for applications ranging from electrolytes for energy storage devices to lubricants for food and cellulose processing to compounds for pharmaceutics, biotransformation, and biopreservation. Due to the ion complexity, many room-temperature ionic liquids readily form amorphous phases upon cooling, even at modest rates. Here, we investigate two commonly studied imidazolium-based room-temperature ionic liquids, 1-ethyl-3-methylimidazolium tetrafluoroborate and 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide, as well as their mixtures, to demonstrate how the complex interplay between the crystalline and amorphous phases is affected by the processing conditions, such as thermal history, liquid mixing, and applied pressure. We show that quantum tunneling in the cation methyl groups, measured by high-resolution inelastic neutron scattering, can be used to probe the order-disorder in room-temperature ionic liquids (crystalline vs amorphous state) that develops as a result of variable processing conditions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Creating and studying a scaled interplanetary coronal mass ejection

The Sun, being an active star, undergoes eruptions of magnetized plasma that reach the Earth and cause the aurorae near the poles. These eruptions, called coronal mass ejections (CMEs), send plasma and magnetic fields out into space. CMEs that reach planetary orbits are called interplanetary coronal mass ejections (ICMEs) and are a source of geomagnetic storms, which can cause major damage to our modern electrical systems with limited warning. To study ICME propagation, we devised a scaled experiment using the Big Red Ball (BRB) plasma containment device at the Wisconsin Plasma Physics Laboratory. These experiments inject a compact torus of plasma as an ICME through an ambient plasma inside the BRB, which acts as the interplanetary medium. Magnetic and temperature probes provide three-dimensional magnetic field information in time and space, as well as temperature and density as a function of time. Using this information, we can identify features in the compact torus that are consistent with those in real ICMEs. We also identify the shock, sheath, and ejecta similar to the structure of an ICME event. This experiment acts as a first step to providing information that can inform predictive models, which can give us time to shield our satellites and large electrical systems in the event that a powerful ICME were to strike.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Temperature dependent striction effect in a single crystalline Nd 2 Fe 14 B revealed using a novel high temperature resistivity measurement technique

In this work, we studied the temperature dependence of resistivity in a single crystalline Nd 2 Fe 14 B using a newly developed high temperature probe. This novel probe employs mechanical pin connectors instead of conducting glue/paste. From warming and cooling curves, the Curie temperature was consistently measured around T c = 580 K. In addition, anomalous discrete jumps were found only in cooling curves between 400 and 500 K, but not shown in warming curves. More interestingly, when the jumps occurred during cooling, the resistivity was increased. This phenomenon could possibly be due to a temperature dependent striction effect induced by the re-orientation of magnetic domains well below the Curie temperature. Further microscopic study is needed to confirm this effect.

permanent magnet↗

Probes For Measuring Changing Internal Temperatures

Improved thermocouple probes devised for measuring rapidly changing temperatures within layers of solid materials. In original application, layers in question are carbon-cloth phenolic liners in solid-rocket motor nozzles, and probes inserted in layers to various depths of order of 0.5 in. measure changing temperatures in layers during hot-fire tests. Probe concept adapted to measurements of temperatures inside various other layers, materials, and components, including material test specimens.

Hunt, S. B.↗

Diagnostics of Carbon Nanotube Formation in a Laser Produced Plume: An Investigation of the Metal Catalyst by Laser Ablation Atomic Fluorescence Spectroscopy

Carbon nanotubes, elongated molecular tubes with diameters of nanometers and lengths in microns, hold great promise for material science. Hopes for super strong light-weight material to be used in spacecraft design is the driving force behind nanotube work at JSC. The molecular nature of these materials requires the appropriate tools for investigation of their structure, properties, and formation. The mechanism of nanotube formation is of particular interest because it may hold keys to controlling the formation of different types of nanotubes and allow them to be produced in much greater quantities at less cost than is currently available. This summer's work involved the interpretation of data taken last summer and analyzed over the academic year. The work involved diagnostic studies of carbon nanotube formation processes occurring in a laser-produced plume. Laser ablation of metal doped graphite to produce a plasma plume in which carbon nanotubes self assemble is one method of making carbon nanotube. The laser ablation method is amenable to applying the techniques of laser spectroscopy, a powerful tool for probing the energies and dynamics of atomic and molecular species. The experimental work performed last summer involved probing one of the metal catalysts, nickel, by laser induced fluorescence. The nickel atom was studied as a function of oven temperature, probe laser wavelength, time after ablation, and position in the laser produced plume. This data along with previously obtained data on carbon was analyzed over the academic year. Interpretations of the data were developed this summer along with discussions of future work. The temperature of the oven in which the target is ablated greatly influences the amount of material ablated and the propagation of the plume. The ablation conditions and the time scale of atomic and molecular lifetimes suggest that initial ablation of the metal doped carbon target results in atomic and small molecular species. The metal atoms survive for several milliseconds while the gaseous carbon atoms and small molecules nucleate more rapidly. Additional experiments and the development of in situ methods for carbon nanotube detection would allow these results to be interpreted from the perspective of carbon nanotube formation.

deBoer, Gary↗

A Unique Test Facility to Measure Liner Performance with a Summary of Initial Test Results

A very ambitious study was initiated to obtain detailed acoustic and flow data with and without a liner in a duct containing a mean flow so that available theoretical models of duct liners can be validated. A unique flow-duct facility equipped with a sound source, liner box, flush-walled microphones, traversable microphones and traversable pressure and temperature probes was built. A unique set of instrumentation boxes equipped with computer controlled traverses were designed and built that allowed measurements of Mach number, temperature, SPLs and phases in two planes upstream of a liner section and two planes downstream at a large number of measurement points. Each pair of planes provided acoustic pressure gradients for use in estimating the particle velocities. Specially-built microphone probes were employed to make measurements in the presence of the flow. A microphone traverse was also designed to measure the distribution of SPLs and phases from the beginning of the liner to its end along the duct axis. All measurements were made with the help of cross-correlation techniques to reject flow noise and/or other obtrusive noise, if any. The facility was designed for future use at temperatures as high as 1500 F. In order to validate 2-D models in the presence of mean flow, the flow duct was equipped with a device to modify boundary layer flow on the smaller sides of a rectangular duct to simulate 2-D flow. A massive amount of data was acquired for use in validating duct liner models and will be provided to NASA in an electronic form. It was found that the sound in the plane-wave regime is well behaved within the duct and the results are repeatable from one run to another. At the higher frequencies corresponding to the higher-order modes, the SPLs within a duct are not repeatable from run to run. In fact, when two or more modes have the same frequency (i.e., for the degenerate modes), the SPLs in the duct varied between 2 dB to 12 dB from run to run. This made the calibration of the microphone probes extremely difficult at the higher frequencies.

Ahuja, K. K.↗