Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TECHNOLOGISTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Use of Online Media for Professional Development Amongst Medical Radiation Practitioners in Australia and Canada

Online media allows access to professional development (PD) regardless of geographical location and has the potential to provide equitable, immediate and quality PD. Online media includes online information and social media. The purpose of this mixed methods research study was to investigate the perceptions and use of online media for PD amongst medical radiation practitioners within Australia and Canada. An online survey was circulated to members of the Canadian Association of Medical Radiation Technologists (CAMRT) and the Australian Society of Medical Imaging and Radiation Therapy (ASMIRT). The survey collected data within three domains: current use, satisfaction of use, and future use. A four point Likert scale was used for both satisfaction with the online platform and frequency of use. Two hundred and thirty-nine responses were collected. Results indicated that the online mechanisms most frequently used by respondents for PD were Google, self-directed learning, and intranet. A correlating degree of satisfaction was indicated with the use of these platforms. The least used online media for PD were social media platforms including health related blogs, LinkedIn, Twitter, health related and professional applications, Facebook, and online journal clubs. Online media is well suited to PD for medical radiation practitioners. The platforms that are preferred offer speed and ease of access regardless of geographical location or occupation. Whilst inherent risks and instances of unprofessional online behaviour are acknowledged, Australian and Canadian practitioners are keen to learn what social media PD opportunities exist. Findings indicate that radiation therapists are more receptive to explore new social media platforms and tools than are radiographers. There is an opportunity to incorporate formal PD for medical radiation practitioners within recognised social media platforms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Evaluation of Image Acquisition Techniques, Radiographic Practice, and Technical Quality in Neonatal Chest Radiography

Neonatal chest radiography is a frequently performed diagnostic examination, particularly in preterm infants where anatomical and/or biochemical immaturity impacts on respiratory function. However, the quality of neonatal radiographic images has been criticized internationally and a prevailing concern has been that radiographers (radiologic technologists) fail to appreciate the unique nature of neonatal and infant anatomical proportions. The aim of this study was to undertake a retrospective evaluation of neonatal chest radiography image acquisition techniques against key technical criteria.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessing Transgender-Related Content in Radiography Programs in the United States: A Survey of Educators

Imaging science technologists care for diverse populations of individuals and need to be adequately prepared to provide optimal patient care that reduces any potential disparities among these individuals. In particular, exposure to transgender individuals is increasing in today's society. The purpose of this research study was to examine the extent to which transgender-related content is taught in radiography programs in the United States by surveying educators to assess their knowledge of, experience with, and readiness to teach such content.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study on the effect of the operating condition on a pulverized coal-fired furnace using computational fluid dynamics commercial code

Computer models for coal combustion are not sufficiently accurate to enable the design of pulverized coal fired furnaces or the selection of coal based on combustion behavior. Most comprehensive combustion models can predict with reasonable accuracy flow fields and heat transfer but usually with a much lesser degree of accuracy than the combustion of coal particles through char burnout. Computational fluid dynamics (CFD) modeling is recognized widely to be a cost-effective, advanced tool for optimizing the design and operating condition of the pulverized coal-fired furnaces for achieving cleaner and efficient power generation. Technologists and researchers are paying remarkable attention to CFD because of its value in the pulverized fuel fired furnace technology and its nonintrusiveness, sophistication, and ability to significantly reduce the time and expense involved in the design, optimization, trouble-shooting, and repair of power generation equipment. An attempt to study the effect of one of the operating conditions, i.e., burner tilts on coal combustion mechanisms, furnace exit gas temperature (FEGT), and heat flux distribution pattern, within the furnace has been made in this paper by modeling a 210 MW boiler using commercial CFD code FLUENT. 5 refs., 8 figs.

01 COAL, LIGNITE, AND PEAT↗

The Heterogeneous Integration of Electronic Components

Heterogeneous integration (HI) of electronics components is broadly recognized as a powerful and crucial enabler for the continued growth of computing and communication. From 2010 onwards, the value of HI is increasingly visible in the advanced packaging used in artificial intelligence, high-performance computing, smartphones and communications product implementations. In this Perspective, we argue that HI is crucial to semiconductors and more broadly to the continued evolution of computing and communications. We use leading-edge advanced packaging examples to represent the value, advancements and opportunities for HI. To succeed, it is critical to develop comprehensive HI roadmaps that inform collaborations across the design, manufacturing and reliability spectrum between systems architects, packaging and semiconductor technologists to common goals. Although this article does not provide a full roadmap, we instead detail additional parameters for artificial intelligence, smartphone and other cellular communication devices, and their constituent building blocks including interconnects, power electronics, photonics, thermal management, reliability, modelling and co-design, to foster greater collaboration opportunities among academia, research laboratories and industry.

42 ENGINEERING↗

Software Analytical Instrument for Assessment of the Process of Casting Slabs

The paper describes the original proposal of ways of solution and function of the program equipment for assessment of the process of casting slabs. The program system LITIOS was developed and implemented in EVRAZ Vitkovice Steel Ostrava on the equipment of continuous casting of steel (further only ECC). This program system works on the data warehouse of technological parameters of casting and quality parameters of slabs. It enables an ECC technologist to analyze the course of casting melt and with using statistics methods to set the influence of single technological parameters on the duality of final slabs. The system also enables long term monitoring and optimization of the production.

36 MATERIALS SCIENCE↗

Observing a previously hidden structural-phase transition onset through heteroepitaxial cap response

Significance We provide an approach to study structural transitions by using appropriate heteroepitaxial caps. Previously unobservable phase transitions that involve small changes in lattice constants, but may have important impact on the physical properties of the material, can now be detected in real space. Using the coherent nanotwinning waves of epitaxial La 0.7 Sr 0.3 MnO 3 /SrTiO 3 thin films as a sensitive detector, we are able to uncover the onset stage of the cubic-to-tetragonal structural-phase transition of SrTiO 3 in real space. Researchers involved in the study of material properties as well as technologists in a variety of industries, such as electronics, will greatly benefit from this approach.

36 MATERIALS SCIENCE↗

The Past Informs the Future: An Overview of the Million Worker Study and the Mallinckrodt Chemical Works Cohort

The purpose of this paper is to present an overview of ongoing work on the Million Worker Study (MWS), highlighting some of the key methods and progress so far as exemplified by the study of workers at the Mallinckrodt Chemical Works (MCW). The MWS began nearly 25 y ago and continues in a stepwise fashion, evaluating one study cohort at a time. It includes workers from U.S. Department of Energy (DOE) Manhattan Project facilities, U.S. Nuclear Regulatory Commission (NRC) regulated nuclear power plants, industrial radiographers, U.S. Department of Defense (DoD) nuclear weapons test participants, and physicians and technologists working with medical radiation. The purpose is to fill the major gap in radiation protection and science: What is the risk when exposure is received gradually over time rather than briefly as for the atomic bomb survivors? Studies published or planned in 2018 include leukemia (and dosimetry) among atomic veterans, leukemia among nuclear power plant workers, mortality among workers at the MCW, and a comprehensive National Council on Radiation Protection and Measurements (NCRP) Report on dosimetry for the MWS. MCW has a singular place in history: the 40 tons (T) of uranium oxide produced at MCW were used by Enrico Fermi on 2 December 1942 to produce the first manmade sustained and controlled nuclear reaction, and the atomic age was born. Seventy-six years later, the authors followed the over 2,500 MCW workers for mortality and reconstructed dose from six sources of exposure: external gamma rays from the radioactive elements in pitchblende; medical x rays from occupationally required chest examinations; intakes of pitchblende (uranium, radium, and silica) measured by urine samples; radon breath analyses and dust surveys overseen by Robley Evans and Merril Eisenbud; occupational exposures received before and after employment at MCW; and cumulative radon concentrations and lung dose from the decay of radium in the work environment. The unique exposure reconstructions allow for multiple evaluations, including estimates of silica dust. The study results are relevant today. For example, NASA is interested that radium, deposited in the brain, releases high-LET alpha particles - the only human analogue, though limited, for high energy, high-Z particles (galactic cosmic rays) traveling through space that might affect astronauts on Mars missions. In conclusion, don’t discount the past; it’s the prologue to the future!

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

LCOE*: Re-Thinking LCOE for Photovoltaic Systems

Solar industry is working towards reducing the levelized cost of energy (LCOE). The LCOE formulation includes various implicitly connected cost and physical design parameters. This entails complex cost analyses by economists, and electrical analysis and energy yield calculations of solar farms by device physicists/technologists. The standard formulation requires a constant exchange of information to optimize the design of a specific farm. In this paper, we present a fundamental reformulation of LCOE (in terms of LCOE*) to deconvolve the cost vs. energy yield analysis so that economists and technologists can work independently towards minimizing LCOE. We validate our LCOE* formulation by comparing LCOE calculated by the traditional vs. new method. We further provide a global analysis of LCOE* as an illustrative example. This LCOE* will accelerate new technology development (e.g. bifacial PV) by allowing a rapid and transparent analysis of its cost-performance trade-off.

14 SOLAR ENERGY↗

Systematic Approaches to Digital Forensic Engineering: Moving from Art to Disciplines

Advancing digital forensics engineering requires the expertise of technologists, analysts, and legal experts to produce sound computer systems and sound forensic practices which will meet the needs of courtroom presentation as well as minimizing negative effects on the cyber-system original purpose. As with the first year, the 2007 SADFE workshop, brings together top digital forensic researchers, advanced tool/product builders, and expert law enforcement representatives from around the world for information exchange and R&D collaboration.

97 MATHEMATICS AND COMPUTING↗

Computerized quantitative evaluation of mammographic accreditation phantom images

Purpose: The objective was to develop and investigate an automated scoring scheme of the American College of Radiology (ACR) mammographic accreditation phantom (RMI 156, Middleton, WI) images. Methods: The developed method consisted of background subtraction, determination of region of interest, classification of fiber and mass objects by Mahalanobis distance, detection of specks by template matching, and rule-based scoring. Fifty-one phantom images were collected from 51 facilities for this study (one facility provided one image). A medical physicist and two radiologic technologists also scored the images. The human and computerized scores were compared. Results: In terms of meeting the ACR's criteria, the accuracies of the developed method for computerized evaluation of fiber, mass, and speck were 90%, 80%, and 98%, respectively. Contingency table analysis revealed significant association between observer and computer scores for microcalcifications (p<5%) but not for masses and fibers. Conclusions: The developed method may achieve a stable assessment of visibility for test objects in mammographic accreditation phantom image in whether the phantom image meets the ACR's criteria in the evaluation test, although there is room left for improvement in the approach for fiber and mass objects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved image quality of cone beam CT scans for radiotherapy image guidance using fiber-interspaced antiscatter grid

Purpose: Medical linear accelerator mounted cone beam CT (CBCT) scanner provides useful soft tissue contrast for purposes of image guidance in radiotherapy. The presence of extensive scattered radiation has a negative effect on soft tissue visibility and uniformity of CBCT scans. Antiscatter grids (ASG) are used in the field of diagnostic radiography to mitigate the scatter. They usually do increase the contrast of the scan, but simultaneously increase the noise. Therefore, and considering other scatter mitigation mechanisms present in a CBCT scanner, the applicability of ASGs with aluminum interspacing for a wide range of imaging conditions has been inconclusive in previous studies. In recent years, grids using fiber interspacers have appeared, providing grids with higher scatter rejection while maintaining reasonable transmission of primary radiation. The purpose of this study was to evaluate the impact of one such grid on CBCT image quality. Methods: The grid used (Philips Medical Systems) had ratio of 21:1, frequency 36 lp/cm, and nominal selectivity of 11.9. It was mounted on the kV flat panel detector of an Elekta Synergy linear accelerator and tested in a phantom and a clinical study. Due to the flex of the linac and presence of gridline artifacts an angle dependent gain correction algorithm was devised to mitigate resulting artifacts. Scan reconstruction was performed using XVI4.5 augmented with inhouse developed image lag correction and Hounsfield unit calibration. To determine the necessary parameters for Hounsfield unit calibration and software scatter correction parameters, the Catphan 600 (The Phantom Laboratory) phantom was used. Image quality parameters were evaluated using CIRS CBCT Image Quality and Electron Density Phantom (CIRS) in two different geometries: one modeling head and neck and other pelvic region. Phantoms were acquired with and without the grid and reconstructed with and without software correction which was adapted for the different acquisition scenarios. Parameters used in the phantom study weret{sub cup} for nonuniformity and contrast-to-noise ratio (CNR) for soft tissue visibility. Clinical scans were evaluated in an observer study in which four experienced radiotherapy technologists rated soft tissue visibility and uniformity of scans with and without the grid. Results: The proposed angle dependent gain correction algorithm suppressed the visible ring artifacts. Grid had a beneficial impact on nonuniformity, contrast to noise ratio, and Hounsfield unit accuracy for both scanning geometries. The nonuniformity reduced by 90% for head sized object and 91% for pelvic-sized object. CNR improved compared to no corrections on average by a factor 2.8 for the head sized object, and 2.2 for the pelvic sized phantom. Grid outperformed software correction alone, but adding additional software correction to the grid was overall the best strategy. In the observer study, a significant improvement was found in both soft tissue visibility and nonuniformity of scans when grid is used. Conclusions: The evaluated fiber-interspaced grid improved the image quality of the CBCT system for broad range of imaging conditions. Clinical scans show significant improvement in soft tissue visibility and uniformity without the need to increase the imaging dose.

60 APPLIED LIFE SCIENCES↗

SU-C-9A-02: Structured Noise Index as An Automated Quality Control for Nuclear Medicine: A Two Year Experience

Purpose: Flood-field uniformity evaluation is an essential element in the assessment of nuclear medicine (NM) gamma cameras. It serves as the central element of the quality control (QC) program, acquired and analyzed on a daily basis prior to clinical imaging. Uniformity images are traditionally analyzed using pixel value-based metrics which often fail to capture subtle structure and patterns caused by changes in gamma camera performance requiring additional visual inspection which is subjective and time demanding. The goal of this project was to develop and implement a robust QC metrology for NM that is effective in identifying non-uniformity issues, reporting issues in a timely manner for efficient correction prior to clinical involvement, all incorporated into an automated effortless workflow, and to characterize the program over a two year period. Methods: A new quantitative uniformity analysis metric was developed based on 2D noise power spectrum metrology and confirmed based on expert observer visual analysis. The metric, termed Structured Noise Index (SNI) was then integrated into an automated program to analyze, archive, and report on daily NM QC uniformity images. The effectiveness of the program was evaluated over a period of 2 years. Results: The SNI metric successfully identified visually apparent non-uniformities overlooked by the pixel valuebased analysis methods. Implementation of the program has resulted in nonuniformity identification in about 12% of daily flood images. In addition, due to the vigilance of staff response, the percentage of days exceeding trigger value shows a decline over time. Conclusion: The SNI provides a robust quantification of the NM performance of gamma camera uniformity. It operates seamlessly across a fleet of multiple camera models. The automated process provides effective workflow within the NM spectra between physicist, technologist, and clinical engineer. The reliability of this process has made it the preferred platform for NM uniformity analysis.

07 ISOTOPE AND RADIATION SOURCES↗

SU-D-18C-06: Initial Experience with Implementing MRI Safety Guidelines for Patients with Pacemakers - Medical Physicist Perspective

Purpose: Several institutions have developed MRI guidelines for patients with MR-unsafe or MR-conditional pacemakers. Here we highlight the role of a medical physicist in implementing these guidelines for non-pacemaker dependent patients. Guidelines: Implementing these guidelines requires involvement from several medical specialties and a strong collaboration with the site MRI supervisor to develop a structured workflow. A medical physicist is required to be present during the scan to supervise the MR scanning and to maintain a safety checklist that ensures: 1) uninterrupted patient communication with the technologist, 2) continuous patient physiologic monitoring (e.g. blood pressure and electrocardiography) by a trained nurse, 3) redundant patient vitals monitoring (e.g. pulse oximetry) due to the possibility of in vivo electrocardiography reading fluctuations during image acquisition. A radiologist is strongly recommended to be available to review the images before patients are discharged from the scanner. Pacemaker MRI should be restricted to 1.5T field strength. The MRI sequences should be optimized by the physicist with regards to: a) SAR: limited to <1.5 W/Kg for MR-unsafe pacemakers in normal operating mode, b) RF exposure time: <30 min, c) Coils: use T/R coils but not restricted to such, d) Artifacts: further optimization of sequences whenever image quality is compromised due to the pacemaker. In particular, cardiac, breast and left-shoulder MRIs are most susceptible to these artifacts. Possible strategies to lower the SAR include: a) BW reduction, 2) echo-train-length reduction, 3) increase TR, 4) decrease number of averages, 5) decrease flip angle, 6) reduce slices and/or a combination of all the options. Conclusion: A medical physicist in collaboration with the MR supervisor plays an important role in the supervision/implementation of safe MR scanning of pacemaker patients. Developing and establishing a workflow has enabled our institution to scan over 30 patients with pacemakers without complications, including 3 cardiac MR exams.

60 APPLIED LIFE SCIENCES↗

SU-E-E-05: Initial Experience On Physics Rotation of Radiological Residents

Purpose: The new ABR core exam integrates physics into clinical teaching, with an emphasis on understanding image quality, image artifacts, radiation dose and patient safety for each modality and/or sub-specialty. Accordingly, physics training of radiological residents faces a challenge. A traditional teaching of physics through didactic lectures may not fully fulfill this goal. It is also difficult to incorporate physics teaching in clinical practice due to time constraints. A dedicated physics rotation may be a solution. This study is to evaluate a full week physics workshop developed for the first year radiological residents. Methods: The physics rotation took a full week. It included three major parts, introduction lectures, hand-on experiences and observation of technologist operation. An introduction of basic concepts was given to each modality at the beginning. Hand-on experiments were emphasized and took most of time. During hand-on experiments, residents performed radiation measurements, studied the relationship between patient dose and practice (i.e., fluoroscopy), investigated influence of acquisition parameters (i.g., kV, mAs) on image quality, and evaluated image quality using phantoms A physics test before and after the workshop was also given but not for comparison purpose. Results: The evaluation shows that the physics rotation during the first week of residency in radiology is preferred by all residents. The length of a full week of physics workshop is appropriate. All residents think that the intensive workshop can significantly benefit their coming clinical rotations. Residents become more comfortable regarding the use of radiation and counseling relevant questions such as a pregnant patient risk from a CE PE examination. Conclusion: A dedicated physics rotation, assisting with didactic lectures, may fulfill the requirements of physics of the new ABR core exam. It helps radiologists deeply understand the physics concepts and more efficiently use the medical physics in practice.

60 APPLIED LIFE SCIENCES↗

SU-E-I-27: Establishing Target Exposure Index Values for Computed Radiography

Purpose: To develop a standard set of target exposure index (TEI) values to be applied to Agfa Computed Radiography (CR) readers in accordance with International Electrotechnical Committee 62494-1 (ed. 1.0). Methods: A large data cohort was collected from six USAF Medical Treatment Facilities that exclusively use Agfa CR Readers. Dose monitoring statistics were collected from each reader. The data was analyzed based on anatomic region, view, and processing speed class. The Agfa specific exposure metric, logarithmic mean (LGM), was converted to exposure index (EI) for each data set. The optimum TEI value was determined by minimizing the number of studies that fell outside the acceptable deviation index (DI) range of +/− 2 for phototimed techniques or a range of +/−3 for fixed techniques. An anthropomorphic radiographic phantom was used to corroborate the TEI recommendations. Images were acquired of several anatomic regions and views using standard techniques. The images were then evaluated by two radiologists as either acceptable or unacceptable. The acceptable image with the lowest exposure and EI value was compared to the recommended TEI values using a passing DI range. Results: Target EI values were determined for a comprehensive list of anatomic regions and views. Conclusion: Target EI values must be established on each CR unit in order to provide a positive feedback system for the technologist. This system will serve as a mechanism to prevent under or overexposures of patients. The TEI recommendations are a first attempt at a large scale process improvement with the goal of setting reasonable and standardized TEI values. The implementation and effectiveness of the recommended TEI values should be monitored and adjustments made as necessary.

60 APPLIED LIFE SCIENCES↗

SU-E-I-90: Medical Physicists' Implication in Diagnostic CT in Switzerland: Results of After One Year of Experience

Purpose: Since January 1st 2008, the Swiss ordinance on radiation protection requires the involvement of a medical physicist to support the optimization process of medical imaging techniques using ionizing radiation. After a long process of implementation, this requirement is satisfied all over the country since the beginning of 2013. The goal of this contribution is to summarize the main results obtained in this first year of experience in CT. Methods: We assessed the output and clinical use of 45 CT units using a three-pronged approach. First, we assessed the output of the device (CTDIvol, primary beam collimation and HU in water at different tube tensions). Secondly, we characterized the local chest and abdomen acquisition and reconstruction protocols using the Catphan 600 phantom. Lastly, we assessed the clinical use of the machine by analyzing an extract of a dozen clinical examinations per unit. Results: 9 out of 45 units had incorrect collimator settings, e.g. 4mm instead of 1mm. We witnessed also a large spread in reconstruction parameters, especially for reconstructed slice thickness, thus showing notable variations in low contrast detectability performances. Clinical practice is also clearly spread out. For example, estimated patient effective dose per abdomen examination lies at 18.7+/−12.7mSv (min: 2.0mSv — max: 112.0mSv). Chest and brain scans have a narrower dispersion, but patient effective dose is also spread by about a factor of 10 to 20. Conclusion: The spread in clinical practice being fairly large, it appears of crucial importance to collaborate more closely with radiologists and technologists to assess it. The lack of statistical precision will imply that we analyze clinical practice according to a specific medical demand rather than an anatomical region. Furthermore, low contrast sensitivity (LCD) being a crucial parameter, an objective method using a model observer will be used to assess LCD.

60 APPLIED LIFE SCIENCES↗

SU-E-I-91: Reproducibility in Prescribed Dose in AEC CT Scans Due to Table Height, Patient Size, and Localizer Acquisition Order

Purpose: In CT scanners, the automatic exposure control (AEC) tube current prescription depends on the acquired prescan localizer image(s). The purpose of this study was to quantify the effect that table height, patient size, and localizer acquisition order may have on the reproducibility in prescribed dose. Methods: Three phantoms were used for this study: the Mercury Phantom (comprises three tapered and four uniform regions of polyethylene 16, 23, 30, and 37 cm in diameter), acrylic sheets, and an adult anthropomorphic phantom. Phantoms were positioned per clinical protocol by our chief CT technologist or broader symmetry. Using a GE Discovery CT750HD scanner, a lateral (LAT) and posterior-anterior (PA) localizer was acquired for each phantom at different table heights. AEC scan acquisitions were prescribed for each combination of phantom, localizer orientation, and table height; the displayed volume CTDI was recorded for each. Results were analyzed versus table height. Results: For the two largest Mercury Phantom section scans based on the PA localizer, the percent change in volume CTDI from ideal were at least 20% lower and 35% greater for table heights 4 cm above and 4 cm below proper centering, respectively. For scans based on the LAT localizer, the percent change in volume CTDI from ideal were no greater than 12% different for 4 cm differences in table height. The properly centered PA and LAT localizer-based volume CTDI values were within 13% of each other. Conclusion: Since uncertainty in vertical patient positioning is inherently greater than lateral positioning and because the variability in dose exceeds any dose penalties incurred, the LAT localizer should be used to precisely and reproducibly deliver the intended amount of radiation prescribed by CT protocols. CT protocols can be adjusted to minimize the expected change in average patient dose.

60 APPLIED LIFE SCIENCES↗