Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TECHNETIUM ISOTOPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A New Process for Small-Batch Purification of the Medical Isotope Molybdenum-99: Non-Technical Overview

The U.S. medical community depends on a reliable supply of the radioisotope molybdenum-99 (Mo-99) for nuclear medical diagnostic procedures. Mo-99's decay product, technetium-99m (Tc-99m), is used in over 40,000 medical procedures in the United States each day to diagnose heart disease and cancer, to study organ structure and function, and to perform other important medical applications. For example, patients undergoing a common procedure—the cardiac “stress test”—likely have benefited from Tc-99m. Historically, Mo-99 was primarily produced through the fission of uranium-235, in the form of highly enriched uranium (HEU) targets irradiated in research and test reactors. HEU is a proliferation-sensitive material that, if diverted or stolen, could be used as a component of a nuclear weapon. NNSA’s Office of Material Management and Minimization (M3) manages the Molybdenum-99 (Mo-99) Program as part of its mission to minimize the use of HEU in civilian applications. The Mo-99 Program assists global Mo-99 production facilities in converting to non-HEU processes and supports the establishment of domestic supplies of Mo-99 without the use of proliferation-sensitive HEU. As part of this program, M3 funds U.S. national laboratories to provide non-proprietary technical support to U.S. companies working to establish non-HEU-based Mo-99 production capabilities. The results of this research are published on OSTI.gov for the benefit of the Mo-99 community and the public. However, it can be difficult for readers without a scientific background to understand and interpret these publications. In order to increase public understanding of the work being done in M3’s Mo-99 Program, this paper aims to provide an overview of a key, recent national laboratory technical publication in terms that can be understood by readers without a technical background. To accomplish this, the paper first explains key scientific concepts—primarily related to chemistry—that provide a foundation for understanding research in this area. This includes chromatography, absorption vs. adsorption, dissolution and precipitation, and liquid-liquid extraction. Drawing on these concepts, the paper then provides an explanation for non-technical audiences of the Argonne National Laboratory publication entitled Recovery of High Specific Activity Molybdenum-99 from Accelerator-Induced Fission on Low-Enriched Uranium for Technetium-99m Generators (Brown, M.A. et al., 2021) and related article Separation and Purification of Mo-99 Produced from Natural U3O8 Targets via Photo-Fission (Brown, M.A. et al., 2021).

Stamler, Bradley↗

Determination of the first ionization potential of technetium

The first ionization potential (IP) of technetium (Tc) has been determined by evaluating Rydberg convergences toward the first ionization potential as well as toward two low-lying excited states of the singly charged Tc ion. The Rydberg states were excited and detected by applying multiphoton resonance ionization mass spectrometry (RIMS) on the long-lived isotope {sup 99g}Tc using a three-color excitation scheme. The observed Rydberg convergences yield a result for the first ionization potential of Tc V{sub IP}(Tc)=7.119380(32) eV. This precise value for V{sub IP}(Tc) is somewhat lower than the so far published data of 7.23 eV or 7.28 eV, dating back to the 1950s.

74 ATOMIC AND MOLECULAR PHYSICS↗

Radiation Stability of Benzyl Tributyl Ammonium Chloride towards Technetium-99 Extraction - 13016

A closed nuclear fuel cycle combining new separation technologies along with generation III and generation IV reactors is a promising way to achieve a sustainable energy supply. But it is important to keep in mind that future recycling processes of used nuclear fuel (UNF) must minimize wastes, improve partitioning processes, and integrate waste considerations into processes. New separation processes are being developed worldwide to complement the actual industrialized PUREX process which selectively separates U(VI) and Pu(IV) from the raffinate. As an example, the UREX process has been developed in the United States to co-extract hexavalent uranium (U) and hepta-valent technetium (Tc) by tri-n-butyl phosphate (TBP). Tc-99 is recognized to be one of the most abundant, long-lived radio-toxic isotopes in UNF (half-life, t{sub 1/2} = 2.13 x 10{sup 5} years), and as such, is targeted in UNF separation strategies for isolation and encapsulation in solid waste-forms for final disposal in a nuclear waste repository. Immobilization of Tc-99 by a durable solid waste-form is a challenge, and its fate in new advanced technology processes is of importance. It is essential to be able to quantify and locate 1) its occurrence in any new developed flowsheets, 2) its chemical form in the individual phases of a process, 3) its potential quantitative transfer in any waste streams, and consequently, 4) its quantitative separation for either potential transmutation to Ru-100 or isolation and encapsulation in solid waste-forms for ultimate disposal. In addition, as a result of an U(VI)-Tc(VII) co-extraction in a UREX-based process, Tc(VII) could be found in low level waste (LLW) streams. There is a need for the development of new extraction systems that would selectively extract Tc-99 from LLW streams and concentrate it for feed into high level waste (HLW) for either Tc-99 immobilization in metallic waste-forms (Tc-Zr alloys), and/or borosilicate-based waste glass. Studies have been launched to investigate the suitability of new macro-compounds such as crown-ethers, aza-crown ethers, quaternary ammonium salts, and resorcin-arenes for the selective extraction of Tc-99 from nitric acid solutions. The selectivity of the ligand is important in evaluating potential separation processes and also the radiation stability of the molecule is essential for minimization of waste and radiolysis products. In this paper, we are reporting the extraction of TcO{sub 4}{sup -} by benzyl tributyl ammonium chloride (BTBA). Experimental efforts were focused on determining the best extraction conditions by varying the ligand's matrix conditions and concentration, as well as varying the organic phase composition (i.e. diluent variation). Furthermore, the ligand has been investigated for radiation stability. The ?-irradiation was performed on the neat organic phases containing the ligand at different absorbed doses to a maximum of 200 kGy using an external Co-60 source. Post-irradiation solvent extraction measurements will be discussed. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Isomeric states in neutron-deficient A{approx}80-90 nuclei populated in the fragmentation of {sup 107}Ag

The relativistic projectile fragmentation of a 750 MeV per nucleon beam of {sup 107}Ag was used to populate isomeric states in neutron-deficient nuclei around A=80-90. Reaction products were separated and unambiguously identified using the GSI FRagment Separator (FRS) and its ancillary detectors. At the final focal plane, the fragments were slowed from relativistic energies by means of an aluminium degrader and implanted in a passive stopper in the center of the high-efficiency, high-granularity Stopped Rare Isotope Spectroscopic INvestigation at GSI (RISING) germanium array. This allowed the identification of excited states in the N=Z nuclei {sub 43}{sup 86}Tc and, for the first time, {sub 41}{sup 82}Nb. Isomeric states have also been identified for the first time in {sup 87,88}Tc, and a previously unreported isomer was observed in {sup 84}Nb. Experimental results are presented along with a discussion on the structure of these nuclei based on interpretations provided by several theoretical models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of a measurement system for Uranium electrodeposition control to radiopharmaceuticals production

For 2016, studies by international bodies forecast a crisis in the supply of Molybdenum ({sup 99}Mo), which is the generator of {sup 99m}Tc, widely used for medical diagnoses and treatments. As a result, many countries are making efforts to prevent this crisis. Brazil is developing the Brazilian Multipurpose Reactor (RMB) project, under the responsibility of the National Nuclear Energy Commission (CNEN). The RMB is a nuclear reactor for research and production of radioisotopes used in the production of radiopharmaceuticals and radioactive sources, broadly used in industrial and research areas in Brazil. Electrodeposition of uranium is a common practice to create samples for alpha spectrometry and this methodology may be an alternative way to produce targets of low enriched uranium (LEU) to fabricate radiopharmaceuticals, as {sup 99}Mo, used for cancer diagnosis. To study the electrodeposition, a solution of 10 mM uranyl nitrate, in 2-propanol, containing uranium enriched to 2.4% in {sup 235}U, with pH = 1, was prepared and measurements with an alpha spectrometer were performed. These studies are justified by the need to produce {sup 99}Mo since, despite using molybdenum in bulk, Brazil is totally dependent on its import. In this project, we intend to obtain a process that may be technologically feasible to control the radiation targets for {sup 99}Mo production. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Letter Report: Stable Hydrogen and Oxygen Isotope Analysis of B-Complex Perched Water Samples

Fine-grained sediments associated with the Cold Creek Unit at Hanford have caused the formation of a perched water aquifer in the deep vadose zone at the B Complex area, which includes waste sites in the 200-DV-1 Operable Unit and the single-shell tank farms in Waste Management Area B-BX-BY. High levels of contaminants, such as uranium, technetium-99, and nitrate, make this aquifer a continuing source of contamination for the groundwater located a few meters below the perched zone. Analysis of deuterium ( 2 H) and 18-oxygen ( 18 O) of nine perched water samples from three different wells was performed. Samples represent time points from hydraulic tests performed on the perched aquifer using the three wells. The isotope analyses showed that the perched water had δ 2 H and δ 18 O ratios consistent with the regional meteoric water line, indicating that local precipitation events at the Hanford site likely account for recharge of the perched water aquifer. Data from the isotope analysis can be used along with pumping and recovery data to help understand the perched water dynamics related to aquifer size and hydraulic control of the aquifer in the future.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mass measurements near the Z = N line with JYFLTRAP

Masses of nuclides involved in astrophysical rp and {nu}p processes have to be known precisely in order to model these processes reliably. Mass excesses for 90 ground state and 8 isomeric states of neutron-deficient nuclides have been determined with a precision of better than 10 keV with the JYFLTRAP double Penning trap mass spectrometer at the Ion-Guide Isotope Separator On-Line facility in Jyvaeskylae. Highlights of the measurements related to nuclear astrophysics are given. Some of the measured isomers, such as {sup 53}Co{sup m}, {sup 90}Tc{sup m}, and {sup 95}Pd{sup m}, and implications for the excitation energy of the 21{sup +} isomer in {sup 94}Ag are briefly discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental activities supporting commercial U.S. accelerator production of 99-Mo

{sup 99m}Tc, the daughter product of {sup 99}Mo, is the most commonly used radioisotope for nuclear medicine in the U.S. Experiments are being performed at Los Alamos National Laboratory and Argonne National Laboratory to demonstrate production of {sup 99}Mo using accelerators. The {sup 100}Mo({gamma},n){sup 99}Mo reaction in an enriched {sup 100}Mo target is currently under investigation. Three scaled low-power production experiments using a 20-MeV electron linac at Argonne have been performed to date. Two of these experiments used natural Mo targets and produced a total of 613 {mu}C of {sup 99}Mo. The third experiment used an enriched {sup 100}Mo target and produced 10.5 mCi of {sup 99}Mo. Following irradiation the targets were dissolved and the low specific activity solution was processed through an ARSII generator from NorthStar Medical Radioisotopes. Yields of {sup 99m}Tc >95% have been observed.

43 PARTICLE ACCELERATORS↗

Low Count and Background Radionuclides Analysis - 20488

The US Department of Energy (DOE) is often faced with the need to evaluate radionuclides at low concentrations. When site sample data are likely to be close to threshold activity concentrations of interest, then the means by which the radiochemical analysis is performed and reported is critical. This situation can occur when differentiating from zero (presence/absence) for radionuclides that do not occur naturally, close comparison with environmental background for naturally occurring radionuclides, close comparison with a risk- or dose-based threshold concentrations of interest, or even comparisons across studies. There are several analytical issues that are of concern, but the two that appear to cause incorrect decisions to be made most often involve establishing detection limits and subtracting ambient background conditions in the laboratory. These issues are not critical when radionuclide activity concentrations are large relative to thresholds of concern, but they seem to be poorly understood when it matters. When the comparisons are important and are likely to be close to a threshold of interest, then the general contract with the analytical laboratories needs to be changed so that the right or appropriate data are obtained. The concern is that important decisions are made incorrectly more often as greater scrutiny is placed on DoE's radionuclide cleanup or monitoring decisions by the public and other stakeholders. Examples are presented of problems that have been observed for different projects, both within and outside the realm of DOE and NRC remediation and radioactive waste disposal problems, and solutions are offered that should lead to better data from which important decisions need to be made. The first example is from Los Alamos National Laboratory (LANL) and involves radionuclide concentrations in soil and rock beneath LANL's Material Disposal Area (MDA) G. An initial review of the data led to a conclusion that americium and plutonium are a long way present beneath MDA G. A more thorough review of the data that accounted properly for ambient background and the detection limits that had been established led to the opposite conclusion. Another example is from the Nevada National Security Site where tritium results from one of the wells were unexpectedly high. Proper understanding and analysis of ambient background led to the conclusion that the increased concentrations were not so obvious, and that a different contract with the analytical laboratory was needed to provide more appropriate data to support a better determination. Other examples are used from regulatory review of projects in Nevada, where background levels and secular equilibrium for naturally occurring radionuclides are not established correctly because of analytical issues. The same basic issues have also been found to create difficulties analyzing historical data from the West Valley Demonstration Project. There is evidence in the data that the apparent lack of secular equilibrium where it is expected to exist is related to ambient background subtraction or other analytical issues. A final example is presented for analysis of Tc-99 in samples of depleted uranium. In this case, two different studies that were performed only three months apart provide quite different results. The US Environmental Protection Agency (EPA) established the data quality objectives (DQO) process in the mid-1980's to establish decision performance criteria for data collection. EPA guidance (EPA G-4, for example) clearly distinguishes between DQOs and measurement performance objectives (MQOs) that should be addressed for laboratory analysis of samples. The language of DQOs and MQOs has become confused over time it seems, and the subsequent effects seem to include a lack of attention to decision performance and a routine approach to measurement quality. In order to better address radionuclide sample analysis when the concentrations are close to thresholds of concern, which might be zero for some radionuclides, background for others, and risk-based thresholds for yet others, it is important that routine laboratory analysis methods are adjusted, and that the project team and the laboratory work closely together to ensure that the data meets the MQO requirements of laboratory analysis and reporting of results, and that the MQOs effectively support project-specific DQOs. This basic approach will be applied in Los Alamos in the coming year to the collection of moisture data from underneath MDA T that will be analyzed for americium and neptunium isotopes. Proper understanding of the radiochemistry methods and reporting, and of appropriate statistical methods is critical to the success of such projects, ensuring that the right decisions are made. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Factors affecting eluation characteristics of sorption generators of technetium-99m

The influence of the adsorbed mass of molybdenum on the width of eluation profiles of generators and the patterns of molybdenum distribution in the amount of chromatographic columns by scanning them on the germanium-gallium detector using collimating device are studied. The boundary conditions under which the maximum value of {sup 99m}Tc yield from generators Y{sub e} = 1 are defined. After scanning the columns, it was found out that the degree of filling the columns with molybdenum Q and the value of its maximum adsorption depend naturally on the total weight of the adsorbed mass. In order to achieve the condition Y{sub e} = 1 the value of Q should be at least 85%.

07 ISOTOPE AND RADIATION SOURCES↗

Three-Component Spectroelectrochemical Sensor Module for the Detection of Pertechnetate (TcO4-)

This review looks at the advancements in the development of a sensor for technetium (Tc) that is applicable to characterizing and monitoring the vadose zone and associated subsurface water. Subsurface contamination by Tc is of particular concern for two reasons: the extremely long lifetime of its most common isotope 99Tc (half-life = 2 x 105 years) and the fast migration in soils of pertechnetate (TcO4–) which is considered to be the dominant 99Tc species in ground water. TcO4– does not have a characteristic spectral signature which prevents its rapid, sensitive, and economic in-situ detection. To address this problem, a novel spectroelectrochemical sensor has been designed that combines three modes of selectivity (electrochemistry, spectroscopy, and selective partitioning) into a single sensor to substantially improve specificity which is critical in the specific detection of an analyte in the presence of potential interfering species. The sensor consists of a basic spectroelectrochemical configuration: a waveguide with an optically transparent electrode (OTE) that is coated with a thin chemically-selective film that preconcnetrates the analyte. The key to adapting this generic sensor to detect TcO4– and Tc complexes lies in the development of chemically-selective films that preconcentrate the analyte and, when necessary, chemically convert it into a complex with electrochemical and spectroscopic properties appropriate for sensing. This review focuses on the general concept of the sensor and the rationale for the selection of the specific components of choice, the development and characterization of the sensor for the different detection modules, the synthesis and characterization of complexes relevant in the detection of technetium, and the progress in the utilization of the sensor module for the effective detection of these complexes.

Environmental Molecular Sciences Laboratory↗

Technetium oxidation in slag-based sodium salt waste forms exposed to water and moist Hanford soil - 15514

Several U.S. DOE sites use or plan to use waste forms and/or concrete containment structures for radioactive waste disposal that are designed to have a chemically reducing environment to immobilize selected contaminants such as Tc(VII)O{sub 4}{sup -} and Cr(VI)O{sub 4}{sup 2-}. These waste forms and containment structures are typically deployed in near surface unsaturated oxidizing environments. Consequently, the effect of exposure to air (oxygen) and water containing dissolved oxygen during production, during the period of institutional control, and over the long term period of performance is important for predicting the speciation and mobility of the redox sensitive radioactive and stable contaminants. Both the SRS and Hanford waste streams contain soluble technetium which may require stabilization to meet disposal requirements. Technetium stabilization is a difficult problem because: 1) Tc is soluble and very mobile in the oxidized form typical of near surface environments, and 2) Tc-99 is a long-lived isotope with a half-life of 2.1 E+05 years which places demanding requirements on the engineered barriers and environment to meet current regulatory disposal requirements. A depth-discrete sampling and leaching method approach for measuring contaminant oxidation rate (effective contaminant specific oxidation rate) was used in this study. The method was modified by coating all sides of a cylindrical sample with an impermeable epoxy and cutting a fresh surface 2 to 2.5 cm from the original top surface eliminates sample inhomogeneity as the result of settling as a reason from observed results and provides 1-D soluble ion transport and gas transport information. Soluble Tc was leached from all of the depth-discrete sub-samples from both Tc2-9 and Tc2-10 which strongly suggests that oxygen was present in the entire length of both samples. About 24 mass percent of the Tc in the original sample, was leached (soluble) from sub-samples between 0.8 and 46 mm below the exposed surface of Tc2-9 (exposed to Hanford sediment). The same percent (24%) was leached from the sub-samples between 0.8 and 11 mm below the exposed surface of Tc2-10 (exposed to DI water). This suggests that the rate of oxygen migration into the sample exposed to soil was faster than the rate of migration into the sample exposed to water which is consistent with the more rapid transport of ions through a gas phase as compared to a liquid phase. It is assumed that moisture in the Hanford sediment was not sufficient to completely block the surface pores with respect to gas transport across the soil-waste form boundary. Based on nitrate leaching results for the depth- discrete sub-samples, regions depleted in nitrates were identified from the top surfaces to 9.5 and 3 mm into samples Tc2-9 (exposed to moist Hanford sediment) and Tc2-10 (DI water). Low mass fractions of nitrate were leached from these depth-discrete samples compared to samples further from the exposed surface presumably because a significant portion of the nitrate had already migrated into the soil or water, respectively. Depth-discrete sub-sample leaching results for Na can be interpreted in the same way over the same regions in the two samples tested. In conclusion, leaching monolithic porous cementitious waste forms in water appears to be conservative for non-redox sensitive contaminants. However, leaching data obtained under saturated exposure conditions do not appear to be conservative for redox sensitive contaminants which are easily oxidized. Leaching crushed samples in water still seems to be a conservative approach to estimating the concentrations of soluble contaminants in a waste form. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Los Alamos National Laboratory Support for Commercial U.S. Production of 99 Mo without the Use of Highly Enriched Uranium

There is currently a serious shortage of 99 Mo, from which to generate the medically significant isotope 99m Tc. Most of the world's supply comes from the fission of highly enriched uranium targets--this is a proliferation concern. This document focuses on the technology involved in two alternative methods: electron accelerator production of 99 Mo from the 100 Mo(γ,n) 99 Mo reaction and production of 99 Mo as a fission product in a subcritical, DT accelerator-driven low enriched uranium salt solution.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The Texas A&M Radioisotope Production and Radiochemistry Program

The main motivation of the project at Texas A&M University was to carry out the production of critically needed radioisotopes used in medicine for diagnostics and therapy, and to establish an academic program in radionuclide production and separation methods. After a lengthy battle with the Texas A&M University Radiation Safety Office, the Texas Department of State Health Services granted us a license for the production of radionuclides in July 2015, allowing us to work in earnest in our project objectives. Experiments began immediately after licensing, and we started the assembly and testing of our target systems. There were four analytical/theoretical projects and two experimental target systems. These were for At-211 production and for Zn-62/Cu-62 production. The theoretical projects were related to the production of Mo-99/Tc-99m using a) a subcritical aqueous target system and b) production of Tc-99m from accelerator-generated Mo-99 utilizing a photon-neutron interaction with enriched Mo-100 targets. The two experimental projects were the development of targetry systems and production of At-211 and Zn-62/Cu-62 generator. The targetry system for At-211 has been tested and production of At-211 is chronic depending of availability of beam time at the cyclotron. The installation and testing of the targetry system for the production of Zn-62/Cu-62 has not been finalized. A description of the systems is described. The academic program in radionuclide production and separation methods was initiated in the fall of 2011 and, due to the lack of a radiochemistry laboratory, it was suspended. We expect to re-start the academic program at the Texas A&M Institute for Preclinical Studies under the Molecular Imaging Program.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Nuclear Data Sheets for A = 103

The 2001 evaluation on mass A = 103 (2001De37) has been revised, taking into account all data available before March 2009. Experimental information is presented from the neutron rich nucleus {sup 103}Sr to the neutron deficient {sup 103}Sn nucleus. The experimental information on excited states for {sup 103}Sr and {sup 103}y is very scarce New (HI, xn{gamma}) data sets for several nuclides have been evaluated and new and more accurate data for {gamma} intensities and multipolarities obtained. The BRICC code has been used for the calculation of conversion coefficients.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Innovative methodology for intercomparison of radionuclide calibrators using short half-life in situ prepared radioactive sources

Purpose: An original radionuclide calibrator method for activity determination is presented. The method could be used for intercomparison surveys for short half-life radioactive sources used in Nuclear Medicine, such as{sup 99m}Tc or most positron emission tomography radiopharmaceuticals. Methods: By evaluation of the resulting net optical density (netOD) using a standardized scanning method of irradiated Gafchromic XRQA2 film, a comparison of the netOD measurement with a previously determined calibration curve can be made and the difference between the tested radionuclide calibrator and a radionuclide calibrator used as reference device can be calculated. To estimate the total expected measurement uncertainties, a careful analysis of the methodology, for the case of{sup 99m}Tc, was performed: reproducibility determination, scanning conditions, and possible fadeout effects. Since every factor of the activity measurement procedure can influence the final result, the method also evaluates correct syringe positioning inside the radionuclide calibrator. Results: As an alternative to using a calibrated source sent to the surveyed site, which requires a relatively long half-life of the nuclide, or sending a portable calibrated radionuclide calibrator, the proposed method uses a source preparedin situ. An indirect activity determination is achieved by the irradiation of a radiochromic film using {sup 99m}Tc under strictly controlled conditions, and cumulated activity calculation from the initial activity and total irradiation time. The irradiated Gafchromic film and the irradiator, without the source, can then be sent to a National Metrology Institute for evaluation of the results. Conclusions: The methodology described in this paper showed to have a good potential for accurate (3%) radionuclide calibrators intercomparison studies for{sup 99m}Tc between Nuclear Medicine centers without source transfer and can easily be adapted to other short half-life radionuclides.

07 ISOTOPE AND RADIATION SOURCES↗

Nuclear Data Sheets for A = 102

The 1998 evaluation on mass A = 102 (1998De15) has been revised, taking into account all data available before december 2008. Detailed experimental information is presented from the neutron rich nucleus {sup 102}Rb to the neutron deficient {sup 102}Sn nucleus. No information on excited states of {sup 102}Rb is available and very scarce for {sup 102}Sr Especially new (HI,xn{gamma}) data sets for several nuclides have been evaluated and new and more accurate data for {gamma} intensities and multipolarities obtained. For {sup 102}Ru very precise new data of the Budapest (n,{gamma}) collaboration have been included.A new and very elaborated decay scheme for {sup 102}In is obtained. Isomerism in {sup 102}Y and {sup 102}Nb needs further investigation due to conflicting results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mass measurements in the vicinity of the r p-process and the {nu} p-process paths with the Penning trap facilities JYFLTRAP and SHIPTRAP

The masses of very neutron-deficient nuclides close to the astrophysical r p- and {nu} p-process paths have been determined with the Penning trap facilities JYFLTRAP at JYFL/Jyvaeskylae and SHIPTRAP at GSI/Darmstadt. Isotopes from yttrium (Z=39) to palladium (Z=46) have been produced in heavy-ion fusion-evaporation reactions. In total, 21 nuclides were studied, and almost half of the mass values were experimentally determined for the first time: {sup 88}Tc, {sup 90-92}Ru, {sup 92-94}Rh, and {sup 94,95}Pd. For the {sup 95}Pd{sup m}, (21/2{sup +}) high-spin state, a first direct mass determination was performed. Relative mass uncertainties of typically {delta}m/m=5x10{sup -8} were obtained. The impact of the new mass values has been studied in {nu} p-process nucleosynthesis calculations. The resulting reaction flow and the final abundances are compared with those obtained with the data of the Atomic Mass Evaluation 2003.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗