Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Systematic error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A systematic error affecting NER calculations

Factors that may affect the precision of Neutron Emission Rate (NER) measurements made in the Canberra 4 neutron counter have been examined and quantified. Measurements of sample NER are corrected for the efficiency of the counter. The efficiency is calculated by measuring a source of known intensity, and taking the ratio of the measured neutrons per second (n/s) to the known output of the source.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Systematic errors in Hadamard transform optics

Error sources encountered in Hadamard transform optical instruments are discussed. Such errors are caused by factors including moving masks, incorrect mask alignment, defects in mask fabrication, missing data, drifts in background level, and diffraction. Techniques for error reduction and/or elimination are described for each of the cases considered. It is noted that the errors described occur in singly encoded spectrometers and imagers.

Sloane, N. J. A.↗

Systematic Errors in Stereo PIV When Imaging through a Glass Window

This document assesses the magnitude of velocity measurement errors that may arise when performing stereo particle image velocimetry (PIV) with cameras viewing through thick, refractive window and where the calibration is performed in one plane only. The effect of the window is to introduce a refractive error that increases with window thickness and the camera angle of incidence. The calibration should be performed while viewing through the test section window, otherwise a potentially significant error may be introduced that affects each velocity component differently. However, even when the calibration is performed correctly, another error may arise during the stereo reconstruction if the perspective angle determined for each camera does not account for the displacement of the light rays as they refract through the thick window. Care should be exercised when applying in a single-plane calibration since certain implicit assumptions may in fact require conditions that are extremely difficult to meet in a practical laboratory environment. It is suggested that the effort expended to ensure this accuracy may be better expended in performing a more lengthy volumetric calibration procedure, which does not rely upon the assumptions implicit in the single plane method and avoids the need for the perspective angle to be calculated.

Green, Richard↗

ASSESSMENT OF SYSTEMATIC CHROMATIC ERRORS THAT IMPACT SUB-1% PHOTOMETRIC PRECISION IN LARGE-AREA SKY SURVEYS

Meeting the science goals for many current and future ground-based optical large-area sky surveys requires that the calibrated broadband photometry is both stable in time and uniform over the sky to 1% precision or better. Past and current surveys have achieved photometric precision of 1%–2% by calibrating the survey’s stellar photometry with repeated measurements of a large number of stars observed in multiple epochs. The calibration techniques employed by these surveys only consider the relative frame-by-frame photometric zeropoint offset and the focal plane position-dependent illumination corrections, which are independent of the source color. However, variations in the wavelength dependence of the atmospheric transmission and the instrumental throughput induce source color-dependent systematic errors. These systematic errors must also be considered to achieve the most precise photometric measurements. In this paper, we examine such systematic chromatic errors (SCEs) using photometry from the Dark Energy Survey (DES) as an example. We first define a natural magnitude system for DES and calculate the systematic errors on stellar magnitudes when the atmospheric transmission and instrumental throughput deviate from the natural system. We conclude that the SCEs caused by the change of airmass in each exposure, the change of the precipitable water vapor and aerosol in the atmosphere over time, and the non-uniformity of instrumental throughput over the focal plane can be up to 2% in some bandpasses. We then compare the calculated SCEs with the observed DES data. For the test sample data, we correct these errors using measurements of the atmospheric transmission and instrumental throughput from auxiliary calibration systems. The residual after correction is less than 0.3%. Moreover, we calculate such SCEs for Type Ia supernovae and elliptical galaxies and find that the chromatic errors for non-stellar objects are redshift-dependent and can be larger than those for stars at certain redshifts.

79 ASTRONOMY AND ASTROPHYSICS↗

First Simultaneous Determination of Inclusive and Exclusive | V u b |

The first simultaneous determination of the absolute value of the Cabibbo-Kobayashi-Maskawa matrix element V ub using inclusive and exclusive decays is performed with the full Belle data set at the $Υ$(4S) resonance, corresponding to an integrated luminosity of 711 fb -1 . We analyze collision events in which one B meson is fully reconstructed in hadronic modes. This allows for the reconstruction of the hadronic X u system of the semileptonic b → $πℓe_ℓ$ decay. We separate exclusive B → $πℓ\overline{ν}_ℓ$ decays from other inclusive B → $X_uℓ\overline{ν}_ℓ$ and backgrounds with a two-dimensional fit that utilizes the number of charged pions in the X u system and the four-momentum transfer q 2 between the B and X u systems. Combining our measurement with information from lattice QCD and QCD calculations of the inclusive partial rate as well as external experimental information on the shape of the B → $πℓe_ℓ$ form factor, we determine |$V^{excl}_{ub}$| = (3.78 ± 0.23 ± 0.16 ± 0.14) × 10 -3 and |$V^{incl}_{ub}$| = (3.88 ± 0.20 ± 0.31 ± 0.09) x 10 -3 , respectively, with the uncertainties being the statistical error, systematic errors, and theory errors. The ratio of |$V^{excl}_{ub}$|/|$V^{incl}_{ub}$| 0.97 ± 0.12 is compatible with unity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On the accuracy and precision of extinctions derived from general star counts

The accuracy and the applicability of the method of general star counts are discussed. The effects of statistical errors, pseudorandom errors, systematic errors, and sampling errors are considered. The conditions under which quantitatively useful results can be derived are identified. It is found that for plates reaching 17th to 20th mag, general star counts can be a useful technique for investigating the structure of dark cloud complexes located within 500 to 1000 pc of the sun.

Rossano, G. S.↗

An analysis of the least-squares problem for the DSN systematic pointing error model

A systematic pointing error model is used to calibrate antennas in the Deep Space Network. The least squares problem is described and analyzed along with the solution methods used to determine the model's parameters. Specifically studied are the rank degeneracy problems resulting from beam pointing error measurement sets that incorporate inadequate sky coverage. A least squares parameter subset selection method is described and its applicability to the systematic error modeling process is demonstrated on Voyager 2 measurement distribution.

Alvarez, L. S.↗

The completed SDSS-IV extended Baryon Oscillation Spectroscopic Survey: BAO and RSD measurements from the anisotropic power spectrum of the quasar sample between redshift 0.8 and 2.2

ABSTRACT We measure the clustering of quasars of the final data release (DR16) of eBOSS. The sample contains $343\, 708$ quasars between redshifts 0.8 ≤ z ≤ 2.2 over $4699\, \mathrm{deg}^2$. We calculate the Legendre multipoles (0,2,4) of the anisotropic power spectrum and perform a BAO and a Full-Shape (FS) analysis at the effective redshift zeff = 1.480. The errors include systematic errors that amount to 1/3 of the statistical error. The systematic errors comprise a modelling part studied using a blind N-body mock challenge and observational effects studied with approximate mocks to account for various types of redshift smearing and fibre collisions. For the BAO analysis, we measure the transverse comoving distance DM(zeff)/rdrag = 30.60 ± 0.90 and the Hubble distance DH(zeff)/rdrag = 13.34 ± 0.60. This agrees with the configuration space analysis, and the consensus yields: DM(zeff)/rdrag = 30.69 ± 0.80 and DH(zeff)/rdrag = 13.26 ± 0.55. In the FS analysis, we fit the power spectrum using a model based on Regularised Perturbation Theory, which includes redshift space distortions and the Alcock–Paczynski effect. The results are DM(zeff)/rdrag = 30.68 ± 0.90 and DH(zeff)/rdrag = 13.52 ± 0.51 and we constrain the linear growth rate of structure f(zeff)σ8(zeff) = 0.476 ± 0.047. Our results agree with the configuration space analysis. The consensus analysis of the eBOSS quasar sample yields: DM(zeff)/rdrag = 30.21 ± 0.79, DH(zeff)/rdrag = 3.23 ± 0.47, and f(zeff)σ8(zeff) = 0.462 ± 0.045 and is consistent with a flat ΛCDM cosmological model using Planck results.

Neveux, Richard↗

SU-F-BRD-03: Determination of Plan Robustness for Systematic Setup Errors Using Trilinear Interpolation

Purpose: Treatment plan evaluations in radiotherapy are currently ignoring the dosimetric impact of setup uncertainties. The determination of the robustness for systematic errors is rather computational intensive. This work investigates interpolation schemes to quantify the robustness of treatment plans for systematic errors in terms of efficiency and accuracy. Methods: The impact of systematic errors on dose distributions for patient treatment plans is determined by using the Swiss Monte Carlo Plan (SMCP). Errors in all translational directions are considered, ranging from −3 to +3 mm in mm steps. For each systematic error a full MC dose calculation is performed leading to 343 dose calculations, used as benchmarks. The interpolation uses only a subset of the 343 calculations, namely 9, 15 or 27, and determines all dose distributions by trilinear interpolation. This procedure is applied for a prostate and a head and neck case using Volumetric Modulated Arc Therapy with 2 arcs. The relative differences of the dose volume histograms (DVHs) of the target and the organs at risks are compared. Finally, the interpolation schemes are used to compare robustness of 4- versus 2-arcs in the head and neck treatment plan. Results: Relative local differences of the DVHs increase for decreasing number of dose calculations used in the interpolation. The mean deviations are <1%, 3.5% and 6.5% for a subset of 27, 15 and 9 used dose calculations, respectively. Thereby the dose computation times are reduced by factors of 13, 25 and 43, respectively. The comparison of the 4- versus 2-arcs plan shows a decrease in robustness; however, this is outweighed by the dosimetric improvements. Conclusion: The results of this study suggest that the use of trilinear interpolation to determine the robustness of treatment plans can remarkably reduce the number of dose calculations. This work was supported by Varian Medical Systems. This work was supported by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗