Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “System Unreliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

System Study: High-Pressure Safety Injection 1998–2018

This report presents an unreliability evaluation of the high-pressure safety injection system (HPSI) at 69 U.S. commercial nuclear power plants. Demand, run hours, and failure data from calendar years 1998 through 2018 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS), formerly the INPO Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10 year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the HPSI results.

99 GENERAL AND MISCELLANEOUS↗

A Diagnoser Algorithm for Anomaly Detection in DEDS under Partial Unreliable Observations: Characterization and Inclusion in Sensor Configuration Optimizaton

Complex engineering systems have to be carefully monitored to meet demanding performance requirements, including detecting anomalies in their operations. There are two major monitoring challenges for these systems. The first challenge is that information collected from the monitored system is often partial and/or unreliable, in the sense that some occurred events may not be reported and/or may be reported incorrectly (e.g., reported as another event). The second is that anomalies often consist of sequences of event patterns separated in space and time. This paper introduces and analyzes a diagnoser algorithm that meets these challenges for detecting and counting occurrences of anomalies in engineering systems. The proposed diagnoser algorithm assumes that models are available for characterizing plant operations (via stochastic automata) and sensors (via probabilistic mappings) used for reporting partial and unreliable information. Methods for analyzing the effects of model uncertainties on the diagnoser performance are also discussed. In order to select configurations that reduce sensor costs, while satisfying diagnoser performance requirements, a sensor configuration selection algorithm developed in previous work is then extended for the proposed diagnoser algorithm. The proposed algorithms and methods are then applied to a multi-unit-operation system, which is derived from an actual facility application. Results show that the proposed diagnoser algorithm is able to detect and count occurrences of anomalies accurately and that its performance is robust to model uncertainties. Furthermore, the sensor configuration selection algorithm is able to suggest optimal sensor configurations with significantly reduced costs, while still yielding acceptable performance for counting the occurrences of anomalies.

97 MATHEMATICS AND COMPUTING↗

System Study: Reactor Core Isolation Cooling 1998–2013

This report presents an unreliability evaluation of the reactor core isolation cooling (RCIC) system at 31 U.S. commercial boiling water reactors. Demand, run hours, and failure data from fiscal year 1998 through 2013 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10-year period, while yearly estimates for system unreliability are provided for the entire active period. No statistically significant trends were identified in the RCIC results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Toward a New Metric for Ranking High Performance Computing Systems

The High Performance Linpack (HPL), or Top 500, benchmark is the most widely recognized and discussed metric for ranking high performance computing systems. However, HPL is increasingly unreliable as a true measure of system performance for a growing collection of important science and engineering applications. In this paper we describe a new high performance conjugate gradient (HPCG) benchmark. HPCG is composed of computations and data access patterns more commonly found in applications. Using HPCG we strive for a better correlation to real scientific application performance and expect to drive computer system design and implementation in directions that will better impact performance improvement.

Heroux, Michael Allen↗

System Study: Reactor Core Isolation Cooling 1998-2014

This report presents an unreliability evaluation of the reactor core isolation cooling (RCIC) system at 31 U.S. commercial boiling water reactors. Demand, run hours, and failure data from fiscal year 1998 through 2014 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10 year period, while yearly estimates for system unreliability are provided for the entire active period. No statistically significant trends were identified in the RCIC results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

System Study: Reactor Core Isolation Cooling 1998–2012

This report presents an unreliability evaluation of the reactor core isolation cooling (RCIC) system at 31 U.S. commercial boiling water reactors. Demand, run hours, and failure data from fiscal year 1998 through 2012 for selected components were obtained from the Equipment Performance and Information Exchange (EPIX). The unreliability results are trended for the most recent 10 year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing trend was identified in the HPCI results. Statistically significant decreasing trends were identified for RCIC start-only and 8-hour trends.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Coverage modeling for dependability analysis of fault-tolerant systems

Several different models for predicting coverage in a fault-tolerant system, including models for permanent, intermittent, and transient errors, are discussed. Markov, semi-Markov, nonhomogeneous Markov, and extended stochastic Petri net models for computing coverage are developed. Two types of events that interfere with recovery are examined; and methods for modeling such events, whether they are deterministic or random, are given. The sensitivity of system reliability/availability to the coverage parameter and the sensitivity of the coverage parameter to various error-handling strategies are investigated. It is found that a policy of attempting transient recovery upon detection of an error can actually increase the unreliability of the system. This result is true if the error detectability is not nearly perfect, so that the risk of producing an undetectable error is greater than the benefit gained by not discarding the component.

Dugan, Joanne Bechta↗

System Study: High-Pressure Safety Injection 1998-2014

This report presents an unreliability evaluation of the high-pressure safety injection system (HPSI) at 69 U.S. commercial nuclear power plants. Demand, run hours, and failure data from fiscal year 1998 through 2014 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10 year period, while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the HPSI results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

System Study: High-Pressure Safety Injection 1998–2012

This report presents an unreliability evaluation of the high-pressure safety injection system (HPSI) at 69 U.S. commercial nuclear power plants. Demand, run hours, and failure data from fiscal year 1998 through 2012 for selected components were obtained from the Equipment Performance and Information Exchange (EPIX). The unreliability results are trended for the most recent 10 year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the HPSI results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

System Study: High-Pressure Coolant Injection 1998-2012

This report presents an unreliability evaluation of the high-pressure coolant injection system (HPCI) at 69 U.S. commercial nuclear power plants. Demand, run hours, and failure data from fiscal year 1998 through 2012 for selected components were obtained from the Equipment Performance and Information Exchange (EPIX). The unreliability results are trended for the most recent 10 year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the HPCI results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermodynamics and coherence of a trapped dipolar Fermi gas

We develop a mean-field treatment of a polarized trapped Fermi gas with dipole-dipole interactions. Our approach is based on self-consistent semiclassical Hartree-Fock theory that accounts for direct and exchange interactions. We discuss our procedure for numerically implementing the calculation. We study the thermodynamic and the first- and second-order correlation properties of the system. We find that the system entropy depends on the trap geometry, allowing the system to be cooled as the trap aspect ratio is increased, and that exchange interactions cause the correlation functions to be anisotropic in the low-temperature regime. We also find that many uniform gas thermodynamic predictions, for which direct interaction effects vanish, are qualitatively unreliable for trapped systems, most notably for oblate traps. We develop a simplified Hartree formalism that is applicable to anisotropic harmonic traps.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

System Study: High-Pressure Coolant Injection 1998-2014

This report presents an unreliability evaluation of the high-pressure coolant injection system (HPCI) at 25 U.S. commercial boiling water reactors. Demand, run hours, and failure data from fiscal year 1998 through 2014 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10 year period, while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the HPCI results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

System Study: High-Pressure Coolant Injection 1998–2013

This report presents an unreliability evaluation of the high-pressure coolant injection system (HPCI) at 25 U.S. commercial boiling water reactors. Demand, run hours, and failure data from fiscal year 1998 through 2013 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10-year period, while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the HPCI results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

System Study: High-Pressure Safety Injection 1998–2013

This report presents an unreliability evaluation of the high-pressure safety injection system (HPSI) at 69 U.S. commercial nuclear power plants. Demand, run hours, and failure data from fiscal year 1998 through 2013 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10-year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the HPSI results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

On reliable control system designs with and without feedback reconfigurations

This paper contains an overview of a theoretical framework for the design of reliable multivariable control systems, with special emphasis on actuator failures and necessary actuator redundancy levels. Using a linear model of the system, with Markovian failure probabilities and quadratic performance index, an optimal stochastic control problem is posed and solved. The solution requires the iteration of a set of highly coupled Riccati-like matrix difference equations; if these converge one has a reliable design; if they diverge, the design is unreliable, and the system design cannot be stabilized. In addition, it is shown that the existence of a stabilizing constant feedback gain and the reliability of its implementation is equivalent to the convergence properties of a set of coupled Riccati-like matrix difference equations. In summary, these results can be used for offline studies relating the open loop dynamics, required performance, actuator mean time to failure, and functional or identical actuator redundancy, with and without feedback gain reconfiguration strategies.

Birdwell, J. D.↗

Optimizing Air Transportation Service to Metroplex Airports: Analysis Using the Airline Schedule Optimization Model (ASOM) - Par 2

The air transportation system is a significant driver of the U.S. economy, providing safe, affordable, and rapid transportation. During the past three decades airspace and airport capacity has not grown in step with demand for air transportation; the failure to increase capacity at the same rate as the growth in demand results in unreliable service and systemic delay. This report describes the results of an analysis of airline strategic decision-making that affects geographic access, economic access, and airline finances, extending the analysis of these factors using historic data (from Part 1 of the report). The Airline Schedule Optimization Model (ASOM) was used to evaluate how exogenous factors (passenger demand, airline operating costs, and airport capacity limits) affect geographic access (markets-served, scheduled flights, aircraft size), economic access (airfares), airline finances (profit), and air transportation efficiency (aircraft size). This analysis captures the impact of the implementation of airport capacity limits, as well as the effect of increased hedged fuel prices, which serve as a proxy for increased costs per flight that might occur if auctions or congestion pricing are imposed; also incorporated are demand elasticity curves based on historical data that provide information about how passenger demand is affected by airfare changes.

Donoue, George↗

Selection of active spaces for multiconfigurational wavefunctions

The efficient and accurate description of the electronic structure of strongly correlated systems is still a largely unsolved problem. The usual procedures start with a multiconfigurational (usually a Complete Active Space, CAS) wavefunction which accounts for static correlation and add dynamical correlation by perturbation theory, configuration interaction, or coupled cluster expansion. This procedure requires the correct selection of the active space. Intuitive methods are unreliable for complex systems. The inexpensive black-box unrestricted natural orbital (UNO) criterion postulates that the Unrestricted Hartree-Fock (UHF) charge natural orbitals with fractional occupancy (e.g., between 0.02 and 1.98) constitute the active space. UNOs generally approximate the CAS orbitals so well that the orbital optimization in CAS Self-Consistent Field (CASSCF) may be omitted, resulting in the inexpensive UNO-CAS method. A rigorous testing of the UNO criterion requires comparison with approximate full configuration interaction wavefunctions. This became feasible with the advent of Density Matrix Renormalization Group (DMRG) methods which can approximate highly correlated wavefunctions at affordable cost. We have compared active orbital occupancies in UNO-CAS and CASSCF calculations with DMRG in a number of strongly correlated molecules: compounds of electronegative atoms (F{sub 2}, ozone, and NO{sub 2}), polyenes, aromatic molecules (naphthalene, azulene, anthracene, and nitrobenzene), radicals (phenoxy and benzyl), diradicals (o-, m-, and p-benzyne), and transition metal compounds (nickel-acetylene and Cr{sub 2}). The UNO criterion works well in these cases. Other symmetry breaking solutions, with the possible exception of spatial symmetry, do not appear to be essential to generate the correct active space. In the case of multiple UHF solutions, the natural orbitals of the average UHF density should be used. The problems of the UNO criterion and their potential solutions are discussed: finding the UHF solutions, discontinuities on potential energy surfaces, and inclusion of dynamical electron correlation and generalization to excited states.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using MODIS estimates of fractional snow cover area to improve streamflow forecasts in interior Alaska

Remotely sensed snow cover observations give an opportunity to improve operational snow melt and stream flow forecasting in remote regions. This is particularly true in Alaska, where remote basins and a spatially and temporally sparse gaging network plague efforts to understand and forecast the hydrology of subarctic boreal basins and where climate change is leading to rapid shifts in basin function. In this study,the operational framework employed by the United States (US) National Weather Service, including the Alaska Pacific River Forecast Center, is adapted to integrate Moderate Resolution Imaging Spectroradiometer (MODIS) remotely sensed observations of fractional snow cover area (fSCA) to determine if these data improve streamflow forecasts in interior Alaska river basins. Two versions of MODIS fSCA are tested against a base case extent of snow cover derived by aerial depletion curves: the MODIS 10A1(MOD10A1) and the MODIS Snow Cover Area and Grain size (MODSCAG) product over the period 2000–2010. Observed runoff is compared to simulated runoff to calibrate both iterations of the model. MODIS-forced simulations haveimproved snow depletion timing compared with snow telemetry sites in the basins, with discernable increases in skill for the streamflow simulations.The MODSCAG fSCA version provides moderate increases in skill but is similar to the MOD10A1 results. The basins with the largest improvement in streamflow simulations have the sparsest streamflow observations.Considering the numerous low-quality gages (discontinuous, short, or unreliable) and ungauged systems throughout the high-latitude regions of the globe, this result is valuable and indicates the utility of the MODIS fSCAdata in these regions. Additionally, while improvements in predicted discharge values are subtle, the snow model better represents the physical conditions of the snow pack and therefore provides more robust simulations,which are consistent with the US National Weather Service's move toward a physically based National Water Model. Physically based models may also be more capable of adapting to changing climates than statistical models corrected to past regimes. This work provides direction for both the Alaska Pacific River Forecast Center and other forecast centers across the US to implement remote-sensing observations within their operational framework, to refine the representation of snow, and to improve streamflow forecasting skill in basins with few or poor-quality observations.

54 ENVIRONMENTAL SCIENCES↗