Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “System Reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The HectoMAP Cluster Survey: Spectroscopically Identified Clusters and their Brightest Cluster Galaxies (BCGs)

We apply a friends-of-friends (FoF) algorithm to identify galaxy clusters and we use the catalog to explore the evolutionary synergy between brightest cluster galaxies (BCGs) and their host clusters. We base the cluster catalog on the dense HectoMAP redshift survey (2000 redshifts deg -2 ). The HectoMAP FoF catalog includes 346 clusters with 10 or more spectroscopic members within the range 0.05 < z < 0.55 and with a median z = 0.29. We list these clusters and their members. We also include central velocity dispersions (σ*, BCG ) for the FoF cluster BCGs, a distinctive feature of the HectoMAP FoF catalog. HectoMAP clusters with higher galaxy number density (80 systems) are all genuine clusters with a strong concentration and a prominent BCG in Subaru/Hyper Suprime-Cam images. The phase-space diagrams show the expected elongation along the line of sight. Lower-density systems include some low reliability systems. We establish a connection between BCGs and their host clusters by demonstrating that σ*, BCG /σ cl decreases as a function of cluster velocity dispersion (σ cl ), in contrast, numerical simulations predict a constant σ*, BCG /σ cl . Sets of clusters at two different redshifts show that BCG evolution in massive systems is slow over the redshift range z < 0.4. The data strongly suggest that minor mergers may play an important role in BCG evolution in clusters with σ cl ≳ 300 km s -1 . For lower mass systems (σ cl < 300 km s -1 ), major mergers may play a significant role. The coordinated evolution of BCGs and their host clusters provides an interesting test of simulations in high-density regions of the universe.

79 ASTRONOMY AND ASTROPHYSICS↗

H2@Scale - Validating an Electrolysis System with High Output Pressure: Cooperative Research and Development Final Report, CRADA Number CRD-18-00741

Electrolysis has been a commercially available product for a while and electrolyzers have been a proven capability to provide additional benefits (e.g. controllable load for grid services) in addition to production of hydrogen. The hydrogen output is typically compressed for storage and dispensing. Compression adds cost and decreases system reliability. Honda’s electrolyzer systems have been developed to include electrochemical compression to leverage the production system itself for at least partial compression. In this project, the team will evaluate Honda’s PEM based electrochemical compression system. The system is capable of compressing hydrogen up to 70 MPa electrochemically. Validation testing is the next step to accelerate this technology into the marketplace, as the validation will provide needed data under a variety of operation conditions and controls. These operating conditions and controls are based on over a decade of NLR research and development with low-temperature electrolysis. The validation testing will include preparing NLR’s site for third party evaluation, benchmark testing of Honda’s stack and system, and simulating operation connected to renewables or in a grid service profile. NLR’s Energy System Integration Lab will be the location for the electrolyzer validation research and integrated into the Hydrogen Infrastructure Test & Research Facility (HITRF). This will build into the existing retail style hydrogen fueling station for a fully integrated experimental setup.

08 HYDROGEN↗

Stabilizing the Power System in 2035 and Beyond: Evolving from Grid-Following to Grid-Forming Distributed Inverter Controllers (Final Technical Report)

Under existing grid operations, large synchronous generators provide sufficient rotational inertia to form a rigid backbone for the bulk power system. With photovoltaics (PV) forecasted to provide more than 600 GW of generation by 2050 under the U.S. Department of Energy’s SunShot Initiative objectives, however, it is clear that power electronic inverters will play a dominant role in future systems, and low-inertia stability must be ensured to maintain system reliability. Today, the risks to system stability can be observed on geographically small islands, such as Hawaii, which contain a relatively large amount of installed PV. These risks stem from a fundamental shortcoming of contemporary control strategies—existing inverter controllers cannot guarantee grid stability. Given that future power systems driven by sustainable resources will be characterized by low inertia, locations such as Hawaii provide a glimpse into the obstacles facing future power systems. Considering these challenges, the aim of this project was to develop and demonstrate distributed inverter controllers that enable the reliable control of low-inertia power systems with hundreds of gigawatts of integrated PV.

14 SOLAR ENERGY↗

Explained: Reliability of the Current Power Grid

Maintaining reliability of the bulk power system, which supplies and transmits electricity, is a constant focus of electric grid planners, operators, and regulators. Based on the standards set by power system reliability entities, the U.S. grid has been and continues to be very reliable. Over the past decade the average U.S. customer has only experienced about 15 minutes of outages per year due to supply limitations, with most of those outages occurring due to failures on the distribution system. However, there have been a few notable incidents in recent years tied to extreme weather events. The fact sheet provides and introduction to reliability of the bulk power system in the U.S.

power grid↗

Achieving an 80% Renewable Portfolio in Alaska's Railbelt: Cost Analysis

This study examines the system-level costs and benefits of increased renewable energy deployment in the Railbelt grid, in the context of a proposed 80% renewable portfolio standard (RPS). This work studies the period from 2024 to 2040 and uses a model that simulates the planning, evolution, and operation of the power system to identify the mix of resources that maintains system reliability at the lowest electricity system cost over the period of analysis. The model tracks several reliability metrics, including the ability to serve demand during all hours of the year, even when normal power system failures occur. The model includes several measures (and associated costs) to address the variable output of renewable resources, including additional operating reserves, fuel storage, cycling of fossil plants, and additional equipment needed to maintain system stability. The Reference (least-cost) scenario results in substantial deployment of renewable energy and cost savings, reaching about 76% of Railbelt generation derived from renewables in 2040. Annual savings average about $105 M/year from 2030 to 2040. About 50% of this generation is from wind by 2040. Enforcing an 80% RPS results in about a 2% cumulative reduction in net savings. Demand is met in all scenarios, relying heavily on use of existing hydropower and fossil-fueled generators during periods of low renewable output. Meeting the increase in variability will require substantial changes in how the system is operated, with inverter-based resources providing nearly 100% of electricity during some periods.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Integrated Risk Assessment Process for Digital Instrumentation and Control Upgrades of Nuclear Power Plants

Most of the existing nuclear power plants (NPPs) in the world rely on traditional analog instrumentation and control (I&C) systems for monitoring, control, and protection functions. With the industrial base largely moving to digital systems, the operation and maintenance of plants involves managing issues including lack of needed analog spare parts, increasing maintenance costs, and the loss of vendor support. Compared with existing analog I&C systems, digital I&C systems have significant functional advantages, such as reliable system performance in terms of accuracy and computational capability, high data handling and storage capabilities to fully measure and display operating conditions, and improved capabilities (e.g., fault tolerance, self-testing, signal validation, process system diagnostics). Therefore, the U.S. nuclear power industry has initiated the replacement of existing, aging analog systems with digital I&C technology, and is developing new designs for advanced plants using digital systems in integrated control rooms to provide modern control and protection systems. However, the qualification of digital I&C systems remains a challenge, especially the issue of software common cause failure (CCF), which has been difficult to address. A CCF is the malfunction of two or more plant components or functions due to a single failure source. CCFs have the potential to generate unanalyzed events or sequences that may not be bounded by previous plant accident analyses, therefore, to challenge the plant safety. Existing analyses on CCF in I&C systems are mainly focusing on hardware failures. With the application and upgrades of new digital I&C systems, software CCFs due to design flaws have become a potential threat to plant safety considering most redundancy designs are using the similar digital platforms or software in the operating and application systems. With complex multi-layer redundancy designs to meet the single failure criterion, these I&C safety systems are of a particular concern in the U.S. Nuclear Regulatory Commission (NRC) licensing procedures. Therefore, there is a need to develop an integrated risk assessment strategy with digital CCF and plant transient responses considered to assure the long-term safety and reliability of vital digital systems and reduce uncertainties in costs, time, and support integration of digital systems in the plant. The overall goal of this project is to deliver a strong technical basis to support effective, licensable, and secure digital I&C technologies for the digital upgrades to existing NPPs. To deal with the expensive licensing justifications from regulatory insights, this technical basis is instructive for nuclear vendors and utilities to effectively lower the costs associated with digital compliance and speed-up industry advances by: (1) defining an integrated risk-informed analysis process for digital I&C upgrades including hazard analysis, reliability analysis, and consequence analysis; (2) applying systematic and risk-informed tools to address CCFs and quantify responding failure probabilities for digital I&C technologies; (3) evaluating the impact of digital failures at the individual level, system level, and plant level; and (4) providing insights and suggestions on designs to manage the risks, thus to support the development, licensing, and deployment of advanced digital I&C technologies on NPPs. Upgrading digital I&C (safety and non-safety related) systems in existing NPPs within a cost-effective and regulatory acceptable way offers the foremost means of performance improvements and cost-reductions for existing NPPs. One key outcome of this project is to perform plant-specific risk assessment to provide a sustainable scientific support for enabling industry to balance the digital-related risks, costs, reliability, and safety.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Learning and Fast Adaptation for Grid Emergency Control via Deep Meta Reinforcement Learning

As power systems are undergoing a significant transformation with more uncertainties, less inertia and closer to operation limits, there is increasing risk of large outages. Thus, there is an imperative need to enhance grid emergency control to maintain system reliability and security. Towards this end, great progress has been made in developing deep reinforcement learning (DRL) based grid control solutions in recent years. However, existing DRL-based solutions have two main limitations: 1) they cannot handle well with a wide range of grid operation conditions, system parameters, and contingencies; 2) they generally lack the ability to fast adapt to new grid operation conditions, system parameters, and contingencies, limiting their applicability for real-world applications. Here, in this paper, we mitigate these limitations by developing a novel deep meta-reinforcement learning (DMRL) algorithm. The DMRL combines the meta strategy optimization together with DRL, and trains policies modulated by a latent space that can quickly adapt to new scenarios. We test the developed DMRL algorithm on the IEEE 300-bus system. We demonstrate fast adaptation of the meta-trained DRL polices with latent variables to new operating conditions and scenarios using the proposed method, which achieves superior performance compared to the state-of-the-art DRL and model predictive control (MPC) methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Consensus-Based Approach for Active Power Control and Reserve Estimation in Distributed PV Systems

With the increased adoption of distributed energy resources (DER), they are expected to contribute to power system reliability services and enhance power system stability. This paper presents a distributed consensus control approach for the real-time active power reserve estimation and power management in distributed PV (photovoltaic) systems. The proposed method estimates the cumulative active power reserve from numerous PV generators using only the sparse communication network for a DER aggregator to provide active power regulation services. The real-time active power reserve estimation using the proposed approach can be used by DER aggregators to manage curtailment in distributed PV systems to maintain stipulated reserves and further to provide power system frequency regulation. Using the proposed approach, the DER aggregator only requires measurements at the feeder substation and it does not require information from individual DER units, thereby improving system resiliency. The proposed distributed consensus control method is validated on IEEE 123 testbed using PSCAD simulations.

active power reserve↗

Consensus-Based Approach for Active Power Control and Reserve Estimation in Distributed PV Systems: Preprint

With the increased adoption of distributed energy resources (DER), they are expected to contribute to power system reliability services and enhance power system stability. This paper presents a distributed consensus control approach for the real-time active power reserve estimation and power management in distributed PV (photovoltaic) systems. The proposed method estimates the cumulative active power reserve from numerous PV generators using only the sparse communication network for a DER aggregator to provide active power regulation services. The real-time active power reserve estimation using the proposed approach can be used by DER aggregators to manage curtailment in distributed PV systems to maintain stipulated reserves and further to provide power system frequency regulation. Using the proposed approach, the DER aggregator only requires measurements at the feeder substation and it does not require information from individual DER units, thereby improving system resiliency. The proposed distributed consensus control method is validated on IEEE 123 testbed using PSCAD simulations.

active power reserve↗

Operationalizing Synchrophasors for Enhanced Grid Reliability and Asset Utilization

The report discusses the development of production-grade synchrophasor software applications. The objective is to improve system reliability and asset utilization for offline as well as real-time considerations, as per the Department of Energy (DOE) guidelines specified by Funding Opportunity Announcement (FOA) DE-FOA-0001492. On the one hand, we have developed grid management applications on how to transform synchrophasor-based monitoring into operator guidance, and commercial grade tools addressing industry needs such as NERC Reliability Standards (MOD 26, MOD 27 and MOD 33). On the other hand, with the wide industrial adoption in mind, the developed applications have been fully discussed with utility partners and installed in the utility partners site including 6 field tests. The Model Validation and Calibration software module has been integrated into GE’s PhasorAnalyticsTM. The first commercial contract has been signed even before the close date of this project. The Angle-based Grid Management (AGM), Fast Voltage Security Assessment (FastVSA), Enhanced Islanding Monitoring(EIM) and Enhanced Disturbance Management (EDM) have been integrated into GE’s Grid Stability Assessment line of applications in e-terra Suite of EMS product.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber-Physical Dynamic System (CPDS) Modeling for Frequency Regulation and AGC Services of Distributed Energy Resources

The substantial integration of renewable energy brings significant challenges to balance the system in real time because of the variability and intermittency of renewable power. For the reliable system operation, the frequency regulation service is used to stabilize the system frequency through automatically balancing the system generation and load. On one hand, with the substantially increasing deployment of renewable energy in electricity system, the requirement of frequency regulation (FR) services increases significantly. On the other hand, the current main resource of FR services, the controllable conventional generation, is continuously decreasing in the system generation mix. This means that in the future high renewable penetration power system, additional and alternative reliable FR services providers such as distributed energy storage (DES) resources should be explored. Although the capability of utility-scale energy storage to provide FR services has been demonstrated, the integrated control and dynamic modeling of distributed energy resource (DER) providing frequency regulation grid services has been rarely explored. There are several challenges to adopt DERs to provide reliable grid services as illustrated in FERC 755. First, the distributed installation of DES requires a comprehensive cyber-physical dynamic system (CPDS) modeling to fully consider the impacts of the communication latency variability on its real time FR provision capability. Unlike the conventional generators, there are two-layer communication between DERs and system operators which increase the communication delay. Second, unlike the conventional generators whose dynamic models have been comprehensively studied, the difference among individual DER components' power-dynamic characteristic brings challenges in the accurate dynamic AGC modeling of its power-frequency relationship. Third, the temporal dependent state of charge uncertainty of DERs challenges DERs' power and frequency regulation capacities scheduling in the look-ahead generation scheduling. Therefore, the aggregator should optimize the frequency regulation provision from individual DER in real time. To overcome these challenges, this project proposes a cyber-physical dynamic system (CPDS) model to handle the uncertainty of DERs two-layer communication latency and power dynamics. The variability of DERs' communication delay and dynamic constraints will be comprehensively modeled. The DERs' AGC model with communication delay is designed to validate DESs' frequency regulation services. Like current performance-based frequency regulation evaluation, the delivery of DERs' frequency regulation will be assessed through post-analysis of the actual AGC response with respect to the AGC control signal from system operators. Consequently, the reliability improvement with DERs providing reliable frequency regulation services can be evaluated from a comprehensive perspective considering all the dynamics of communication and power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An economic assessment of behind-the-meter photovoltaics paired with batteries on the Hawaiian Islands.

Due to natural variability and uncertainty, the ever-increasing penetration of solar generation in Hawaii presents challenges to power grid operators to maintain reliable system operation. Demand response (DR) has the potential to be a cost-effective tool for Hawaii to reach its aggressive renewable energy goals while maintaining the reliability of power grids. The Hawaii Public Utilities Commission has approved the Hawaiian Electric Company's revised portfolio of DR programs. The companies have released a grid services purchase agreement and subscribed an initial tranche of load into their DR programs. This paper presents innovative analytical methods and comprehensive economic assessment for distributed photovoltaics (PV) paired with battery energy storage systems (BESSs) for two new DR programs, including fast frequency response and capacity grid service. Optimal dispatch and sizing methods are proposed for the paired system considering different tariff schedules and PV compensation programs across five islands. It was found that while the best resource configuration and potential economic benefits vary with tariff structure, a BESS paired with PV can be optimally dispatched to generate multiple value streams simultaneously. Compensation from DR programs is an important value stream to help increase the cost-effectiveness of the integrated system.

Battery energy storage system↗

ARIES Annual Report FY25

Advanced Research on Integrated Energy Systems (ARIES) at the National Laboratory of the Rockies (NLR) is the U.S. Department of Energy's (DOE's) test bed for energy system demonstration and de-risking. ARIES comprises the largest collection of physical and digital assets in the DOE laboratory complex, supporting flexible configuration across a broad range of energy scenarios. In Fiscal Year 2025, ARIES provided a platform for system-level research to anticipate and address future energy needs in energy security, system reliability, and technology deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Failure Mode and Effects Analysis for a Photovoltaic Inverter

While PV panel reliability continues to increase, PV inverters become the limiting factor for PV system reliability. Consequently, it is critical to have a generic tool from a third party for PV inverter reliability assessment to help 1) utilities/PV farm operators schedule maintenance in advance, and 2) inverter developers improve the next-generation design. However, these two things cannot be accomplished without first understanding the reasons behind inverter failure. Following this idea, as the first step, it is essential to identify and investigate the most failure-prone components within a PV inverter system. After all, any system is only as reliable as the components that are contained within it. This motivates the failure mode and effects analysis (FMEA) work presented for this workshop. The FMEA is conducted as follows: first, the overview of the methodology on the development of the FMEA is presented; then, based on a top-down approach starting from the PV inverter system, critical inverter components with high failure rates are identified and summarized; afterward, a thorough FMEA study at a component-level is performed and its results, including failure modes, failure mechanisms, and critical stressors, are tabulated; finally, according to three rankings (chance of occurrence, severity of occurrence, and ease of detection prior to failure) for each failure mechanism provided by the FMEA, risk priority numbers are calculated and the failure mechanisms along with the critical stressors are ranked in terms of their potentially detrimental effect on the PV inverter.

Brown, Buck↗

Redesigning capacity market to include flexibility via ramp constraints in high-renewable penetrated system

Capacity markets can co-exist alongside the energy and ancillary markets to ensure the medium-term and long-term supply adequacy by remunerating the generation resources for their availability. With the substantially increasing deployment of renewable generation, the system needs more flexibility to quickly mitigate the variability and uncertainty caused by the renewable generation. However, the present capacity market model does not differentiate the flexibility of generating units, so it might not give appropriate pricing signals to more flexible units that are usually more expensive. This is particularly important considering the increasing penetration levels of renewable generation on the electric grid, which increases the need for flexible units. This paper proposes a novel capacity market model considering flexibility requirement (FR) under the high penetration levels of renewable generation. Therefore, the proposed model can give the market-clearing price (MCP) for not only peak load generation capacity but also flexibility requirement. Thus, flexible units will tend to receive more economic incentives than non-flexible units. In the case studies, the profitability of different generation resources under the proposed capacity market model is analyzed and compared to the present capacity market model. The results show that the proposed method can maintain system reliability with regard to both peak load and flexibility requirement efficiently.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing PV Inverter Reliability Through Predictive Maintenance: Insights from Retrofitting of PV Inverters

Photovoltaic (PV) systems represent a cornerstone in the global shift toward sustainable energy generation, with inverters serving as the crucial link between solar panels and the grid. Despite their pivotal role, inverters are susceptible to failures, contributing significantly to maintenance events and operational disruptions in large-scale PV plants. This white paper investigates the importance and methodologies of predictive maintenance strategies that monitor the component-level pre-failure signatures on PV inverters. Through a comprehensive survey of literature and industry professionals, insights on preventive maintenance and retrofitting practices have been gathered. The expert elicitation helps shed light on common challenges and opportunities for improving PV system reliability, particularly inverter reliability. By addressing these challenges, the white paper aims to enhance the long-term viability and effectiveness of solar PV plants in the renewable energy landscape, contributing to the global transition toward environmentally friendly energy generation.

14 SOLAR ENERGY↗