Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Supernate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Cesium Ion Exchange Using Crystalline Silicotitanate with 5.6 M Sodium Simulant

The Low-Activity Waste Pretreatment System (LAWPS) facility is planned to pretreat Hanford tank waste supernate by filtering to remove solids and processing through ion exchange columns to remove cesium. The ion exchange media is currently (since 2018) targeted to be crystalline silicotitanate (CST). This material has been produced as an engineered form (generally spherical beads) by Honeywell UOP LLC (Des Plaines, IL). Previous forms of this media have been tested in a wide array of simulants and process scales, but column breakthrough and batch contact testing to date on actual tank waste has been limited to a few tank wastes. Washington River Protection Solutions requested a series of studies to demonstrate Cs load behavior in a small column format and determine if a simple batch contact test with CST can be used to qualify tank waste supernate prior to processing it in the LAWPS. The goal of the batch contact testing is to determine if there are any issues with the tank waste that would preclude Cs removal by the ion exchanger. Testing was conducted with IONSIV TM R9140-B CST provided by Honeywell UOP in 2018 (Batch 2081000057). The CST was received in the sodium (Na) form, so no pretreatment conditioning to convert to the Na form was required. Before use in testing, the CST was passed through a #25 sieve (710-micron openings) and collected on a #60 sieve (250-micron openings) with the intent of removing any large and fine particles. Physical properties were measured on the CST including particle size distribution (d50 = 570 microns) and scanning electron micrographic examination. The CST was rinsed with water until the contact solution was visually nearly clear. The CST bed density (1.00 g/mL) and CST bed void fraction (0.656) were measured on the sieved and rinsed CST. The batch contact testing varied Cs concentration in a 5.6 M Na simple simulant solution. Testing was conducted in a liquid volume to solids mass ratio of 200. The distribution coefficient (K d ) was determined to be 770 mL/g at the Cs equilibrium condition of 8.0 μg/mL; with a bed density of 1.00 g/mL, this corresponds to a predicted 50% Cs breakthrough of 770 bed volumes (BVs). The Cs load capacity at 8.0 μg/mL equilibrium condition was determined to be 6.16 mg Cs/g dry CST. The column testing was prototypic to the intended LAWPS operations in a lead-lag column format, albeit on a small-scale basis with 10-mL CST beds. The feed was processed downflow through the lead column and then through the lag column. Three flowrates were tested: 1.19, 1.99, and 4.56 BV/h. The feed was displaced with 0.1 M NaOH, and then the columns were rinsed with water sequentially through the lead then lag columns. One column system was evaluated top to bottom with a gamma scanner to assess the axial Cs loading. Table ES.1 summarizes the relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Ion Exchange Using Spherical Resorcinol-Formaldehyde Resin in Support of Waste Qualification Testing for LAWPS

The Low-Activity Waste Pretreatment System (LAWPS) facility is planned to pretreat Hanford tank waste supernate by filtering solids and processing through ion exchange columns to remove cesium. The ion exchange media is currently targeted to be spherical resorcinol-formaldehyde resin (SRF). This media has been tested in a wide array of simulants and process scales, but testing to date on actual tank waste has been limited to two tank wastes. Washington River Protection Solutions (WRPS) requested a study to determine if a simple batch contact test with SRF can be used to qualify tank waste supernate prior to processing it in the LAWPS. The goal of the batch contact testing would be to determine if there are any issues with the tank waste that would preclude Cs removal by the ion exchanger.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multi-Cycle Cesium Ion Exchange Testing Using Spherical Resorcinol-Formaldehyde Resin with Diluted Hanford Tank Waste 241-AP-105

Washington River Protection Solutions requested that at least 4 L of Hanford tank waste collected from tank 241-AP-105 and diluted to approximately 5.6 M Na (AP-105DF) be prepared for use in vitrification studies. Cesium removal was required to meet this objective and the waste pretreatment platform, established at Pacific Northwest National Laboratory, was used to create the vitrification feed. The Test Platform mimicked the Low-Activity Waste Pretreatment System (LAWPS) facility planned to pretreat Hanford tank waste supernate by removing solids in a cross flow filter apparatus and processing the supernate through ion exchange columns to remove cesium. At the time of testing, the ion exchange media was targeted to be spherical resorcinol-formaldehyde (SRF) resin. The SRF resin has been tested with a wide array of simulants and process scales, but column performance testing with actual tank waste had been somewhat limited to two Hanford tank wastes (AP-101 and AN-102) in up to two process cycles. This report describes testing conducted in a total of six load elute cycles with the AP-105DF tank waste. The column system was first tested with simulant and was previously described; this report describes the six process cycle results with the AP-105DF tank waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dead-End Filtration and Crystalline Silicotitanate Cesium Ion Exchange with Hanford Tank Waste AW-102

The Direct Feed Low-Activity Waste (DFLAW) flowsheet provides for the initial production of immobilized low-activity waste (ILAW) by feeding low-activity waste (LAW) directly from tank farms to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) LAW facility for immobilization. Prior to the transfer of feed to the WTP LAW facility, tank supernatant waste will be pretreated by the Tank Side Cesium Removal (TSCR) system to meet the WTP LAW waste acceptance criteria (<3.18E-5 Ci 137Cs/mole of Na). This pretreatment facility will filter the waste to remove suspended solids and remove cesium from the waste stream through ion exchange. Bench-scale filtration testing of 7.4 liters of diluted of AW-102 supernate was conducted using dead-end filtration in the hot cells of the Radiochemical Processing Laboratory at Pacific Northwest National Laboratory. A Mott 70-mm disc filter (media grade 5) was used to capture solids. The filter area was adjusted to 2.2 in2 to match the planned TSCR supernate process volume to surface area ratio. There was no indication of filter fouling and no recoverable solids were observed on the filter. Ion exchange testing with the filtered, diluted AW-102 supernatant was conducted using crystalline silicotitanate (CST) ion exchange media. The IONSIV R9140-B CST was provided by Honeywell UOP, LLC in 2018 (Lot number 8056202-999). The column testing operations were prototypic to the intended Low-Activity Waste Pretreatment System operations in a lead-lag column format, although on a small-scale basis with 10-mL CST beds. The feed was processed downflow through the lead column and then through the lag column at ~1.8 bed volumes per hour (BV/h). After 88.6 BVs of feed processing, the volume in the feed bottle dropped below the inlet tube and the lead column fluid headspace was displaced with air. Feed processing was suspended while a new column was prepared and installed into the lead position. A total of 450 BVs of diluted AW-102 feed were processed through the new lead column; only 4.3% Cs breakthrough was achieved. This volume of feed was insufficient to generate useful Cs loading information without extrapolation. A straight-line extrapolation was used to determine the 50% breakthrough of the lead column and contract limit breakthrough from the lag. The values were found to be 1200 BVs and 930 BVs, respectively.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization Results of SRS Tank 26 Samples FTF-26-19-12 and -13

Savannah River Remediation (SRR) has requested that the Savannah River National Laboratory (SRNL) characterize several samples from the Savannah River Site (SRS) Tank Farm in preparation for Sludge Batch (SB) 10. This report documents the characterization of Tank 26 material received by SRNL in May of 2019. SRR pulled 2 x 200 mL samples (FTF-26-19-12 and FTF-26-19-13) with Tank 26 slurry pumps at 60 inches. Two samples were taken to ensure SRNL has adequate material for the requested analyses. Because both samples were taken at the same time and at the same tank level, SRNL combined the two Tank Farm samples into one sample prior to analyses. Results presented in this report include: weight percent solids, density, elemental composition of supernate and slurry, Cs-137 in supernate and slurry, and slurry total alpha and beta. The sample contained higher than expected total sulfur with a significant insoluble fraction, prompting SRR-E to request a washing study to predict how sulfur will be removed during Tank Farm washing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of Thermolytic Hydrogen Generation Rate in Tank 28 and Tank 39 Samples

This report contains hydrogen generation rate (HGR) measurements of Tank 28 and Tank 39 radioactive samples with and without added glycolate as a function of temperature. The objective of the Tank 28 and Tank 39 HGR measurements is to extend the knowledge from previous sample thermolysis HGR measurements and augment simulant testing for developing models for the Savannah River Site (SRS) Concentration, Storage, and Transfer Facilities (CSTF) thermolysis HGR with and without added glycolate. Tank 28 testing is applicable to concentrated salt supernate, legacy organic compounds resulting from the F-Canyon processes and boiling in the 3H-Evaporator System. Tank 39 testing is applicable to moderately concentrated salt supernate and organic compounds in fresh waste from the H-Canyon processes. For HGR tests with added sodium glycolate, the glycolate concentrations added to Tank 28 (500 mg/L) and Tank 39 (2000 mg/L) are based on concentrations expected to result in quantifiable HGR between temperatures of 70 °C and the atmospheric pressure boiling point. The added glycolate is much higher than the expected future glycolate concentrations in Tank 28, Tank 39, and similar CSTF tanks.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Summary of Analytical Results from Samples Supporting Tank Closure Cesium Removal (TCCR) Batch 3 and Modeling Results for Cs Loading on CST

Savannah River Remediation (SRR) is currently operating the Tank Closure Cesium Removal (TCCR) process to remove 137 Cs from tank waste supernate using an ion exchange process. As part of that process, Savannah River National Laboratory (SRNL) receives and analyzes samples in support of the qualification of each batch to be processed. SRNL recently received supernate samples retrieved from Tank 10H as well as in-tank batch contact samples for characterization in support of qualifying Batch 3 for processing through the TCCR unit. Some results from analysis of those samples have been previously reported. This report documents the remaining analyses of the in-tank batch contact samples as well as the results of ZAM (Zheng, Anthony, Miller) isotherm modeling performed for comparison to the measured results. Results of the additional analyses include analysis of the loading of other radionuclides besides 137 Cs on the crystalline silicotitanate (CST) contained within the in-tank batch contact test samples. Results from those analyses revealed the next highest contributor to the activity on the CST was 90 Sr with an average loading of 2.76E+08 dpm/g CST compared to 3.56E+10 dpm/g CST for the 137Cs. Isotopes of plutonium were also detected on the samples. ZAM modeling was performed using the measured composition of the Tank 10H Batch 3 qualification samples. The modeling predicted a maximum Cs loading approximately 2.2x higher than the measured result. This is a slightly lower ratio (expected/measured) compared to what was observed for the prior TCCR in-tank batch contact testing performed for Batches 1A and 2 where the ZAM results were 2.7-2.8x higher than the measured values.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion Exchange Processing of AP-105 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System

The U.S. Department of Energy (DOE) is working to expedite processing of Hanford tank waste supernate at the Hanford Waste Treatment and Immobilization Plant (WTP). To support this goal, Washington River Protection Solutions, LLC (WRPS, Richland, WA) is designing a system for suspended solids and cesium (Cs/ 137 Cs) removal from Hanford tank waste supernate. The effluent will then be sent to the WTP Low-Activity Waste (LAW) Facility for vitrification. The Cs removal is critical for eliminating the high dose rate associated with 137 Cs and facilitating a contact maintenance philosophy for the LAW Facility. The maximum 137 Cs concentration in the LAW sent to the WTP is targeted to be below the 3.18E-5 Ci 137 Cs/mole of Na waste acceptance criteria (WAC) limit. The filtration and ion exchange systems will be placed near the Hanford tanks and are collectively termed the Tank Side Cesium Removal (TSCR) system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Spent Crystalline Silicotitanate Storage Study—Post AP-105DF Processing

A Tank-Side Cesium Removal (TSCR) system is under development by Washington River Protection Solutions to support initial production of immobilized low-activity waste (LAW) by feeding Hanford tank supernate from tank farms to the Hanford Waste Treatment and Immobilization Plant (WTP) LAW Facility. Tank waste supernate is filtered to remove suspended solids and then Cs is removed by processing it through crystalline silicotitanate (CST) ion exchange media manufactured by Honeywell UOP, LLC. The Cs-loaded CST columns will be stored indefinitely, with a goal of eventual CST removal and treatment. Thus, the spent CST needs to be recoverable after undetermined storage time. Previous testing with AP-105 simulant showed that rinsing the CST bed with 3 bed volumes (1.4 apparatus volumes [AVs]) of 0.1 M NaOH resulted in a dried bed that maintained flow characteristics indicative of ease of recovery. This study explored the intermediate conditions (between feed dried in place and the 1.4 AVs of 0.1 M NaOH rinse) to evaluate CST bed properties.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Spent Crystalline Silicotitanate Storage Study—Post AP-105DF Processing

A Tank-Side Cesium Removal (TSCR) system is under development by Washington River Protection Solutions to support initial production of immobilized low-activity waste (LAW) by feeding Hanford tank supernate from tank farms to the Hanford Waste Treatment and Immobilization Plant (WTP) LAW Facility. Tank waste supernate will be filtered to remove suspended solids and then Cs will be removed by processing it through crystalline silicotitanate (CST) ion exchange media manufactured by Honeywell UOP, LLC. The Cs-loaded CST columns will be stored indefinitely, with a goal of eventual CST removal and treatment. Thus, the spent CST needs to be recoverable after undetermined storage time. Previous testing with AP-105 simulant showed that rinsing the CST bed with 3 bed volumes (1.4 apparatus volumes [AVs]) of 0.1 M NaOH resulted in a dried bed that maintained flow characteristics indicative of ease of recovery. This study explored the intermediate conditions (between feed dried in place and the 1.4 AVs of 0.1 M NaOH rinse) to evaluate CST bed properties after: 1) stoppage with feed in place; 2) stoppage after draining feed; 3) stoppage after 0.7 AV of 0.1 M NaOH rinse through column; 4) stoppage after 1.5 AVs of 0.1 M NaOH rinse through column. Post processing, each column was heated at 50 °C for 19 days under pseudo-storage conditions to simulate the expected dried and stored CST bed conditions. Testing was conducted at the small scale (12-mL bed volume); actual, Cs-depleted, AP-105 tank waste was used as the feed. Post-dried CST bed physical properties (angle of repose and penetration depth) were measured to evaluate how CST moved and flowed. All process stop-conditions resulted in a solidified CST bed except for the final condition, 1.5 AVs of 0.1 M NaOH rinse. At this small scale, the three CST beds presented an issue for retrievability after the short storage period (19 days at 50 °C). The latter case confirmed the results from simulant testing. The testing was intended to provide a preliminary assessment of issues that may arise from desiccation of CST during storage with the indicated salt solutions in place. Since these were small-scale tests, the processing system did not scale to full scale conditions exactly; however, the tests did provide insight into the impact on the dried and stored CST bed after stopping processing at an earlier step (upset condition) than normal. These results indicate that if an upset condition occurs at TSCR, a dilute hydroxide rinse should be considered before the CST dries from internal heating.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Refinement of Salt Dissolution Inhibitor Requirements (Final Report)

At Savannah River Site (SRS), High-Level Waste is stored in below-grade carbon steel tanks. This waste in part consists of sludge, salt cake, and/or supernate. Preparation of this waste for future processing involves dissolution of the salt cake layer. The salt dissolution process can create conditions that leave the carbon steel tanks susceptible to localized corrosion. The salt to be dissolved contains high concentrations of nitrate, that once released, create an environment that may be conducive to pitting corrosion and/or stress corrosion cracking (SCC) of carbon steel. The salt dissolution process also liberates interstitial liquid trapped between the salt crystals. This liquid is initially high in nitrite and hydroxide concentration. High pH and greater ratios of nitrite to nitrate act as inhibitors to minimize corrosion of carbon steel in high nitrate environments. However, as dissolution proceeds, the concentration of nitrate will increase, while the hydroxide and nitrite concentration of the interstitial liquid will deplete and become insufficient to prevent the onset of corrosion attack. Tank blending and addition of inhibitors are used to ensure adequate concentrations of hydroxide and nitrite. However, this is not desirable during salt dissolution as it can reduce process efficiency and increase the amount of waste that needs processing. It has been proposed that these corrosion control limits be revisited to evaluate the corrosion susceptibility of carbon steel in environments that more closely resemble current operating conditions at SRS. An experimental matrix was designed to evaluate the use of the pitting factor for supernate chemistries characteristic to SRS, particularly during the salt dissolution process. Two electrochemical methods were identified to determine the susceptibility of A537 and A285 low-carbon steels to pitting corrosion with this chemistry envelope at temperatures up to 75 °C. The predominant electrochemical test method was Cyclic Potentiodynamic Polarization (CPP) studies. Through CPP, the pitting factor was used, based on Hanford Site corrosion studies, to accurately identify pitting susceptibility within the compositional range studied with some conservatism. Additionally, sulfate was determined to have no statistically significant influence, at concentrations up to 0.6 M, on pitting behavior in more concentrated solutions where other aggressive species govern pitting susceptibility. Where CPP was inconclusive, Modified ASTM G192 was successfully used to evaluate pitting susceptibility conditions and allowed for a pass/fail result to be determined. In all cases, the pitting factor was determined to be applicable to the simulants tested, with this metric accurately predicting incidences in which pitting occurred. Based upon the findings in this work, a pitting factor of 1.2 is being proposed to build in a safety factor and remain consistent with the Hanford Site approach. Additionally, a minimum pH limit of 12 is proposed to ensure carbon steel passivity and localized corrosion the primary degradation mechanism. Susceptibility to SCC was evaluated using a reduced matrix of tests at 75 °C. No failures due SCC were observed at open circuit. In addition, tests polarized anodically by 200 mV only resulted in failures for trials with pitting factors less than 0.86. However, a test with a passing condition based upon the pitting factor metric (pitting factor = 1.40) did exhibit a failure with an applied potential of +300 mV vs. OCP. This result is contrary to the prediction based upon the pitting factor, however, a polarization of 300 mV, or even 200 mV, from open circuit is substantial. The relationship between these testing parameters and service environment/conditions and the desired level of conservatism in the metric should be further evaluated in the determination of the significance of this result. While the pitting factor accurately predicted susceptibility to SCC at temperatures up to 75 °C and with positive overpotentials up to 200 mV, the relatively small sample matrix and failure of a passing pitting factor with a 300 mV polarization resulted in an inconclusive determination of whether the pitting factor may be used for predicting susceptibility to SCC at temperatures between 50 °C and 75 °C. As such, additional testing is recommended to evaluate the validity of the pitting factor for SCC susceptibility prediction at temperatures between 50 °C and 75 °C.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modified Isotherm Modeling to Predict Cs Exchange with Crystalline Silicotitanate in Tank Waste Simulants

The U.S. Department of Energy is working to expedite processing of Hanford tank waste supernate at the Hanford Waste Treatment and Immobilization Plant. To support this goal, Washington River Protection Solutions is designing a Tank Side Cesium Removal (TSCR) system for suspended solids and cesium (Cs/ 137 Cs) removal from Hanford tank waste supernate. The ion exchange media selected for Cs removal at TSCR is crystalline silicotitanate (CST) that is manufactured in a nearly spherical form by Honeywell UOP LLC (UOP; Des Plaines, IL) as product IONSIV® R9140-B (Na form). The Zheng Anthony Miller (ZAM) isotherm model (Zheng et al. 1997) is a multicomponent ion exchange model used to predict the exchange of Group I metals onto CST. The ZAM isotherm has historically been used to predict Cs distribution values from Hanford and Savannah River Site (SRS) tank waste simulants. Figure S.1 summarizes model predictions from the ZAM isotherm that indicate poor prediction of Cs distribution values for simple and complex simulants with the engineered form of CST, IONSIV® R9140-B, and IONSIV® R9120-B where the solid line indicates a perfect fit by the model. The dotted lines indicate ±20% error. Batch contact testing with Hanford tank waste complex and simple simulants was used in conjunction with SRS simulants to experimentally determine Cs distribution values using a modification to the original isotherm model. The experimentally determined maximum Cs capacity for IONSIV® R9140-B CST in both the simple and complex matrices was found to be 0.53±0.3 mmoles Cs/g of CST. This value is not drastically different from the maximum Cs capacity of 0.58 mmoles Cs/g TAM-5 reported by Zheng et al. (1997). However, it is important to note that TAM-5 (commercially IONSIV® IE-910) is a powder. Hamm et al. (2002) determined that a dilution factor was needed to account for the Zr(OH)2 binder in the engineered form of CST. Hamm et al. determined that a dilution factor of 0.68 was appropriate to account for binder contribution and correct overprediction of Cs exchange on the engineered form of CST in ZAM calculations. This reduced the total capacity from 0.58 mmol/g with TAM-5 to 0.39 mmol/g for the engineered form of CST (Hamm et al. 2002). Despite substituting the experimentally determined maximum Cs capacity of 0.55 mmoles Cs/g for the literature-reported capacity of 0.39 mmoles Cs/g, it was determined that additional modifications to the model’s equilibrium rate constants were necessary in refining the isotherm model. The modified model overpredicted K+ uptake by the CST when compared to digested CST results described by Campbell et al. (2019). The modified model was further revised to omit three of the five K+ exchange equilibrium reactions described by ZAM to reduce the additional K+ loading seen by the model. Figure S.2 summarizes the revised model isotherm predictions plotted against measured Kd values.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of CST Post-Processing AP-105 Hanford Tank Waste

The primary goal of the Tank Side Cesium Removal (TSCR) system, under development by Washington River Protection Solutions, LLC (WRPS), is to remove entrained solids and 137 Cs from the Hanford tank waste supernate to expedite production of low-activity waste. Ion exchange (IX) testing of 10.9 L of waste from Hanford tank 241-AP-105 (AP-105), performed by Pacific Northwest National Laboratory, used a lead-lag-polish column format, with a bed volume of 10 mL per column, to decontaminate tank waste supernate using crystalline silicotitanate (CST) as the IX media. The AP-105 Cs IX processing test, discussed elsewhere, resulted in a shorter transition zone (i.e., steeper load curve) than those defined by wastes from tanks 241-AP-107 and 241-AW-102.1 The shorter transition zone was indicative of a matrix effect retarding Cs capacity. Therefore, aliquots of spent CST from the lead, lag, and polish columns were subjected to a digestion protocol to quantify analytes retained by the CST and extrapolate the impact on Cs capacity. The spent CST was digested using a combination of 5 M HNO 3 and H 2 O 2 with vigorous heating and stirring. Due to the radiation dose accompanying the 137 Cs on the CST columns, a secondary Cs separation by ammonium molybdophosphate embedded in polyacrylonitrile (AMP-PAN) was performed to separate the 137 Cs from the CST so the samples could be contact-handled for analysis outside of a shielded facility.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

IDP Analysis of Tank 9H Mined Well Samples

The Savannah River Site (SRS) Tank Farm Transfer Control Program Description Document (PDD) requires Inhalation Dose Potential (IDP) testing to determine whether a transfer qualifies as a “HIGH-REM” (> 2.08E+08 rem/gal) or a “LOW-REM” (≤ 2.08E+08 rem/gal) waste transfer. Due to the unexpected presence of solids in a variable depth sample taken from Tank 9H, transfers from salt tanks potentially containing insoluble solids are currently being assessed as sludge slurry transfers. The insoluble solids concentration of such samples were requested to be adjusted to 16.7 wt% for the results to be used to bound future transfers from that tank. Two samples, HTF-09-21-100 and -101, were received from Tank 9H for analysis to determine IDP. The initial percent insoluble solids concentrations of HTF-09-21-100 and -101 were measured at 4.04 wt% and 6.23 wt%, respectively. Sample HTF-09-21-101 was adjusted to a target of at least 16.7 wt% insoluble solids by removing supernate. Analysis measured the adjusted insoluble solids concentration at 19.0 wt%. A representative sample was obtained for analysis. Then, based on calculations, supernate was added back to HTF-09-21-101 to achieve a percent insoluble solids concentration of 17.1 wt%, and a representative sample was collected for analysis. Based on duplicate analyses at 17.1 wt% and 19.0 wt% insoluble solids, the samples contain less than 0.0012 Ci/L of gross alpha activity. Therefore, the Tank 9H material can be transferred as a “LOW REM” transfer.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Summary of Results from November 2021 Qualification Samples for Tank Closure Cesium Removal 1A (TCCR 1A)

Savannah River Remediation (SRR) is currently operating the Tank Closure Cesium Removal 1A (TCCR 1A) process to remove 137 Cs from tank waste supernate using an ion exchange process. As part of that process, Savannah River National Laboratory (SRNL) receives and analyzes samples in support of the qualification of each batch to be processed. SRNL recently received supernate samples retrieved from Tank 10H as well as in-tank batch contact samples for characterization in support of qualifying Batch 1 for processing through the TCCR 1A unit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Support for HLW Direct Feed

This report describes work performed to develop and test new glass and feed formulations originating from a potential flow-sheet for the direct vitrification of High Level Waste (HLW) with minimal or no pretreatment. In the HLW direct feed option that is under consideration for early WTP operations, the pretreatment facility would be bypassed in order to support an earlier start-up of the vitrification facility. For HLW, this would mean that the ultrafiltration and caustic leaching operations that would otherwise have been performed in the pretreatment facility would either not be performed or would be replaced by an interim pretreatment function (in-tank leaching and settling, for example). These changes would likely affect glass formulations and waste loadings and have impacts on the downstream vitrification operations. Modification of the pretreatment process may result in: (i) Higher aluminum contents if caustic leaching is not performed; (ii) Higher chromium contents if oxidative leaching is not performed; (iii) A higher fraction of supernate in the HLW feed resulting from the lower efficiency of in-tank washing; and (iv) A higher water content due to the likely lower effectiveness of in-tank settling compared to ultrafiltration. The initial efforts reported here focused on the impacts of increased supernate and water content on wastes from one of the candidate source tanks for the direct feed option.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion Exchange Processing of AP-105 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System (Rev.1)

The Tank Side Cesium Removal (TSCR) system, under development by Washington River Protection Solutions LLC (WRPS), will send initial low-activity Hanford waste tank supernate feeds to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIVTM R9140-B), was selected as the ion exchange media at TSCR. CST is a non-elutable inorganic material that has demonstrated robust chemical, physical, and radiation tolerance while maintaining functionality. However, exchange kinetics of Cs onto CST is slow, resulting in low utilization of the CST Cs load capacity before unacceptable Cs breakthrough. Two process flow designs have been tested, as follows. 1. Lead-lag column processing: The lead column was removed after the lag column effluent reached the waste acceptance criteria (WAC) limit, the lag column was moved into the lead position, and a new lag column was installed. This format used ~52% Cs load capacity on the lead column. 2. Lead-lag-polish column processing: The processing was stopped when the polish column effluent reached the WAC limit. This format resulted in 81% Cs load capacity on the lead column. Testing with diluted feed from Hanford tank AP-105 (AP-105DF) incorporated a nuanced change to the lead-lag-polish column system where the polish column was inserted when the lag column effluent reached WAC limit. A 10.9-L volume of AP-105DF (diluted to 5.6 M Na) was processed through the Direct Feed Test Platform system, established at Pacific Northwest National Laboratory to support small-scale waste qualification efforts. The columns consisted of 10-mL CST beds (CST Lot 2002009604, sieved to screen out >30-mesh particles) placed in 1.5-cm-inner-diameter columns. Feed was processed at 1.83 bed volumes (BV) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. The <30-mesh CST sieve cut was expected to provide appropriate performance scaling to a full-height column. The installation of the polish column later in processing (after processing 523 BVs) did not appear to fundamentally change the utilization of the lead column for Cs exchange nor did it extend the total feed processing volume when compared to the previous test with AP-107 feed. Table ES.1 and Figure ES.1 summarize the measured AP-105DF Cs load performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Removal from 5.5 and 7.0 M Na AP-105 Using Crystalline Silicotitanate

The Tank Side Cesium Removal (TSCR) system, currently operational by Washington River Protection Solutions LLC (WRPS), prepares initial low-activity Hanford waste tank supernate feeds for the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP as governed by a waste acceptance criterion (WAC). Specific to 137 Cs, this requirement is < 3.18E-5 Ci 137 Cs/mole of Na. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIVTM R9140-B), has been selected as the ion exchange media for TSCR. CST is a non-elutable inorganic material that has demonstrated robust chemical, physical, and radiation tolerance while maintaining functionality. However, testing to date on actual tank waste samples has been limited to Na concentrations between 5 and 6 M Na (Fiskum et al. 2019a, 2021b and Westesen et al. 2021a, 2021b, 2022) while actual tank conditions can reach upwards of 9 M Na. Testing with feed from Hanford tank AP-105 incorporated testing at both 5.5 and 7 M Na in order to evaluate the impact of Na concentration on volume of waste processed before reaching the WAC. A 6-L volume of 5.5 M Na AP-105 and an 8-volume of 7 M Na AP-105 was processed through the Radioactive Waste Test Platform system, established at Pacific Northwest National Laboratory to support small-scale waste qualification efforts. The columns consisted of 6- to 9-mL CST beds (CST Lot 2002009604, sieved to screen out >30-mesh particles) placed in 1.5-cm-inner-diameter columns. Feed was processed at 1.9 bed volumes (BV) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. Table S.1 and Figure S.1 summarize the measured AP-105 Cs load performance for each feed condition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗