Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Superconducting quantum interference device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Superconducting six-axis accelerometer

A new superconducting accelerometer, capable of measuring both linear and angular accelerations, is under development at the University of Maryland. A single superconducting proof mass is magnetically levitated against gravity or any other proof force. Its relative positions and orientations with respect to the platform are monitored by six superconducting inductance bridges sharing a single amplifier, called the Superconducting Quantum Interference Device (SQUID). The six degrees of freedom, the three linear acceleration components and the three angular acceleration components, of the platform are measured simultaneously. In order to improve the linearity and the dynamic range of the instrument, the demodulated outputs of the SQUID are fed back to appropriate levitation coils so that the proof mass remains at the null position for all six inductance bridges. The expected intrinsic noise of the instrument is 4 x 10(exp -12)m s(exp -2) Hz(exp -1/2) for linear acceleration and 3 x 10(exp -11) rad s(exp -2) Hz(exp -1/2) for angular acceleration in 1-g environment. In 0-g, the linear acceleration sensitivity of the superconducting accelerometer could be improved by two orders of magnitude. The design and the operating principle of a laboratory prototype of the new instrument is discussed.

Paik, H. J.↗

The exceedingly strong two-dimensional ferromagnetism in bi-atomic layer SrRuO 3 with a critical conduction transition

In recent years, few-layer or even monolayer ferromagnetic materials have drawn a great deal of attention due to the promising integration of two-dimensional (2D) magnets into next-generation spintronic devices. The SrRuO 3 monolayer is a rare example of stable 2D magnetism under ambient conditions, but only weak ferromagnetism or antiferromagnetism has been found. The bi-atomic layer SrRuO3 as another environmentally inert 2D magnetic system has been paid less attention heretofore. Here we study both the bi-atomic layer and monolayer SrRuO 3 in (SrRuO 3 ) n /(SrTiO 3 ) m (n = 1, 2) superlattices in which the SrTiO 3 serves as a non-magnetic and insulating space layer. Although the monolayer exhibits arguably weak ferromagnetism, we find that the bi-atomic layer exhibits exceedingly strong ferromagnetism with a T c of 125 K and a saturation magnetization of 1.2 μ B /Ru, demonstrated by both superconducting quantum interference device (SQUID) magnetometry and element-specific X-ray circular dichroism. Moreover, in the bi-atomic layer SrRuO 3 , we demonstrate that random fluctuations and orbital reconstructions inevitably occurring in the 2D limit are critical to the electrical transport, but are much less critical to the ferromagnetism. Our study demonstrates that the bi-atomic layer SrRuO 3 is an exceedingly strong 2D ferromagnetic oxide which has great potentials for applications of ultracompact spintronic devices.

36 MATERIALS SCIENCE↗

Improved Sensing Coils for SQUIDs

An improvement in the design and fabrication of sensing coils of superconducting quantum interference device (SQUID) magnetometers has been proposed to increase sensitivity. It has been estimated that, in some cases, it would be possible to increase sensitivity by about half or to reduce measurement time correspondingly. The pertinent aspects of the problems of design and fabrication can be summarized as follows: In general, to increase the sensitivity of a SQUID magnetometer, it is necessary to maximize the magnetic flux enclosed by the sensing coil while minimizing the self-inductance of this coil. It is often beneficial to fabricate the coil from a thicker wire to reduce its self-inductance. Moreover, to optimize the design of the coil with respect to sensitivity, it may be necessary to shape the wire to other than a commonly available circular or square cross-section. On the other hand, it is not practical to use thicker superconducting wire for the entire superconducting circuit, especially if the design of a specific device requires a persistent-current loop enclosing a remotely placed SQUID sensor. It may be possible to bond a thicker sensing-coil wire to thinner superconducting wires leading to a SQUID sensor, but it could be difficult to ensure reliable superconducting connections, especially if the bonded wires are made of different materials. The main idea is to mold the sensing coil in place, to more nearly optimum cross sectional shape, instead of making the coil by winding standard pre-fabricated wire. For this purpose, a thin superconducting wire loop that is an essential part of the SQUID magnetometer would be encapsulated in a form that would serve as a mold. A low-melting-temperature superconducting metal (e.g., indium, tin, or a lead/tin alloy) would be melted into the form, which would be sized and shaped to impart the required cross section to the coil thus formed.

Penanen, Konstantin↗

Improved Readout Scheme for SQUID-Based Thermometry

An improved readout scheme has been proposed for high-resolution thermometers, (HRTs) based on the use of superconducting quantum interference devices (SQUIDs) to measure temperature- dependent magnetic susceptibilities. The proposed scheme would eliminate counting ambiguities that arise in the conventional scheme, while maintaining the superior magnetic-flux sensitivity of the conventional scheme. The proposed scheme is expected to be especially beneficial for HRT-based temperature control of multiplexed SQUIDbased bolometer sensor arrays. SQUID-based HRTs have become standard for measuring and controlling temperatures in the sub-nano-Kelvin temperature range in a broad range of low-temperature scientific and engineering applications. A typical SQUIDbased HRT that utilizes the conventional scheme includes a coil wound on a core made of a material that has temperature- dependent magnetic susceptibility in the temperature range of interest. The core and the coil are placed in a DC magnetic field provided either by a permanent magnet or as magnetic flux inside a superconducting outer wall. The aforementioned coil is connected to an input coil of a SQUID. Changes in temperature lead to changes in the susceptibility of the core and to changes in the magnetic flux detected by the SQUID. The SQUID readout instrumentation is capable of measuring magnetic-flux changes that correspond to temperature changes down to a noise limit .0.1 nK/Hz1/2. When the flux exceeds a few fundamental flux units, which typically corresponds to a temperature of .100 nK, the SQUID is reset. The temperature range can be greatly expanded if the reset events are carefully tracked and counted, either by a computer running appropriate software or by a dedicated piece of hardware.

Penanen, Konstantin↗

Josephson Junctions and Cosmic Microwave Background

The implementation of utilizing superconducting quantum interference device (SQUID) readout for constant voltage biased transition edge sensors (TES) has enabled the detection of the infinitesimal fluctuation in cosmic microwave background (CMB). The properties of the fluctuations will provide us the information of the universe at the time that this light was first emitted. In short, by measuring the CMB today, we learn about the distant, ancient universe—how the universe began, what it is made of, and how it evolved to its current state. Over the past 20 years, we have achieved many successful CMB measurements with Josephson junctions. Brian, I extend my congratulations on your eight decades of life—Happy 80th birthday!

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantum interference of currents in an atomtronic SQUID

Quantum interference of currents is the most important and well known quantum phenomenon in a conventional superconducting quantum interference device (SQUID). Here, we report the observation of quantum interference of currents in an atomtronic SQUID. Analogous to a conventional SQUID, currents flowing through two junctions in an atomtronic SQUID interfere due to the phase difference from rotation. This interference results in modulation of critical currents. This modulation was observed for three different radii with clear modulation periods which were measured to be consistent with fundamental rotation rates. This observation shows the possibility of studying various interesting SQUID physics with an atomtronic SQUID and especially, macroscopic quantum phenomena with currents may be realized with an atomtronic SQUID toward the goal of quantum metrology of rotation sensing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Oscillating paramagnetic Meissner effect and Berezinskii-Kosterlitz-Thouless transition in underdoped Bi2Sr2CaCu2O8+δ

ABSTRACT Superconducting phase transitions in two dimensions lie beyond the description of the Ginzburg-Landau symmetry-breaking paradigm for three-dimensional superconductors. They are Berezinskii-Kosterlitz-Thouless (BKT) transitions of paired-electron condensate driven by the unbinding of topological excitations, i.e. vortices. The recently discovered monolayers of layered high-transition-temperature (${{{T}}}_{{\rm C}}$) cuprate superconductor Bi2Sr2CaCu2O8+δ (Bi2212) meant that this 2D superconductor promised to be ideal for the study of unconventional superconductivity. But inhomogeneity posed challenges for distinguishing BKT physics from charge correlations in this material. Here, we utilize the phase sensitivity of scanning superconducting quantum interference device microscopy susceptometry to image the local magnetic response of underdoped Bi2212 from the monolayer to the bulk throughout its phase transition. The monolayer segregates into domains with independent phases at elevated temperatures below ${{{T}}}_{{\rm C}}$. Within a single domain, we find that the susceptibility oscillates with flux between diamagnetism and paramagnetism in a Fraunhofer-like pattern up to ${{{T}}}_{{\rm C}}$. The finite modulation period, as well as the broadening of the peaks when approaching ${{{T}}}_{{\rm C}}$ from below, suggests well-defined vortices that are increasingly screened by the dissociation of vortex-antivortex plasma through a BKT transition. In the multilayers, the susceptibility oscillation differs in a small temperature regime below ${{{T}}}_{{\rm C}}$, consistent with a dimensional crossover led by interlayer coupling. Serving as strong evidence for BKT transition in the bulk, we observe a sharp jump in phase stiffness and paramagnetism at small fields just below ${{{T}}}_{{\rm C}}$. These results unify the superconducting phase transitions from the monolayer to the bulk underdoped Bi2212, and can be collectively referred to as the BKT transition with interlayer coupling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic structure and magnetoelectric effect in the centrosymmetric antiferromagnet Cu 2 ( MoO 4 ) ( SeO 3 )

Magnetic properties of Cu 2 ⁢(MoO 4 )⁢(SeO 3 ), an S = $\frac{1}{2}$ centrosymmetric antiferromagnet (AFM), were investigated using superconducting quantum interference device magnetometry, neutron diffraction, and magnetoelectric (ME) measurements. Here, the magnetic susceptibility measurements indicate a broad peak at ~50 K, followed by a phase transition into AFM order at T N = 23.6⁢(1) K. Above T N , a fit to the Curie-Weiss law gives a Curie-Weiss temperature Θ CW = -68⁢(1) K, suggesting the dominant AFM coupling. Neutron powder diffraction reveals that the C⁢u 2+ spins are aligned AFM along the c axis with weak noncollinearity under the magnetic space group of P2$^{'}_{1}$/c. The ME response indicates that a nondiagonal component of a ME tensor is active, supporting the simultaneous spatial and time reversal symmetry breaking under P2$^{'}_{1}$/c.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optimized Geometry for Superconducting Sensing Coils

An optimized geometry has been proposed for superconducting sensing coils that are used in conjunction with superconducting quantum interference devices (SQUIDs) in magnetic resonance imaging (MRI), magnetoencephalography (MEG), and related applications in which magnetic fields of small dipoles are detected. In designing a coil of this type, as in designing other sensing coils, one seeks to maximize the sensitivity of the detector of which the coil is a part, subject to geometric constraints arising from the proximity of other required equipment. In MRI or MEG, the main benefit of maximizing the sensitivity would be to enable minimization of measurement time. In general, to maximize the sensitivity of a detector based on a sensing coil coupled with a SQUID sensor, it is necessary to maximize the magnetic flux enclosed by the sensing coil while minimizing the self-inductance of this coil. Simply making the coil larger may increase its self-inductance and does not necessarily increase sensitivity because it also effectively increases the distance from the sample that contains the source of the signal that one seeks to detect. Additional constraints on the size and shape of the coil and on the distance from the sample arise from the fact that the sample is at room temperature but the coil and the SQUID sensor must be enclosed within a cryogenic shield to maintain superconductivity.

Eom, Byeong Ho↗

Complex magnetic order in the decorated spin-chain system Rb 2 Mn 3 ( MoO 4 ) 3 ( OH ) 2

The macroscopic magnetic properties and microscopic magnetic structure of Rb 2 Mn 3 (MoO 4 ) 3 (OH) 2 (space group Pn ma) are investigated by magnetization, heat capacity, and single-crystal neutron diffraction measurements. The compound's crystal structure contains bond-alternating [Mn 3 O 11 ] ∞ chains along the b axis, formed by isosceles triangles of Mn ions occupying two crystallographically nonequivalent sites (the Mn1 site on the base and Mn2 site on the vertex). These chains are only weakly linked to each other by nonmagnetic oxyanions. Both superconducting quantum interference device magnetometry and neutron diffraction experiments show two successive magnetic transitions as a function of temperature. On cooling, it transitions from a paramagnetic phase into an incommensurate phase below 4.5 K with a magnetic wave vector near k 1 = ( 0 , 0.46 , 0 ). An additional commensurate antiferromagnetically ordered component arises with k 2 = ( 0, 0, 0), forming a complex magnetic structure below 3.5 K with two different propagation vectors of different stars. On further cooling, the incommensurate wave vector undergoes a lock-in transition below 2.3 K. The experimental results suggest that the magnetic superspace group is Pnma. 1' (0b0) s0ss for the single- k incommensurate phase and is Pn' m a ( 0 b 0 ) 00 s for the two- k magnetic phase. We propose a simplified magnetic structure model taking into account the major ordered contributions, where the commensurate k 2 defines the ordering of the c-axis component of the Mn1 magnetic moment, while the incommensurate k 1 describes the ordering of the ab -plane components of both Mn1 and Mn2 moments into elliptical cycloids.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of Position-Sensitive Magnetic Calorimeters for X-Ray Astronomy

Metallic magnetic calorimeters (MMC) are one of the most promising devices to provide very high energy resolution needed for future astronomical x-ray spectroscopy. MMC detectors can be built to large detector arrays having thousands of pixels. Position-sensitive magnetic (PoSM) microcalorimeters consist of multiple absorbers thermally coupled to one magnetic micro calorimeter. Each absorber element has a different thermal coupling to the MMC, resulting in a distribution of different pulse shapes and enabling position discrimination between the absorber elements. PoSMs therefore achieve the large focal plane area with fewer number of readout channels without compromising spatial sampling. Excellent performance of PoSMs was achieved by optimizing the designs of key parameters such as the thermal conductance among the absorbers, magnetic sensor, and heat sink, as well as the absorber heat capacities. Micro fab ri - cation techniques were developed to construct four-absorber PoSMs, in which each absorber consists of a two-layer composite of bismuth and gold. The energy resolution (FWHM full width at half maximum) was measured to be better than 5 eV at 6 keV x-rays for all four absorbers. Position determination was demonstrated with pulse-shape discrimination, as well as with pulse rise time. X-ray microcalorimeters are usually designed to thermalize as quickly as possible to avoid degradation in energy resolution from position dependence to the pulse shapes. Each pixel consists of an absorber and a temperature sensor, both decoupled from the cold bath through a weak thermal link. Each pixel requires a separate readout channel; for instance, with a SQUID (superconducting quantum interference device). For future astronomy missions where thousands to millions of resolution elements are required, having an individual SQUID readout channel for each pixel becomes difficult. One route to attaining these goals is a position-sensitive detector in which a large continuous or pixilated array of x-ray absorbers shares fewer numbers of temperature sensors. A means of discriminating the signals from different absorber positions, however, needs to be built into the device for each sensor. The design concept for the device is such that the shape of the temperature pulse with time depends on the location of the absorber. This inherent position sensitivity of the signal is then analyzed to determine the location of the event precisely, effectively yielding one device with many sub-pixels. With such devices, the total number of electronic channels required to read out a given number of pixels is significantly reduced. PoSMs were developed that consist of four discrete absorbers connected to a single magnetic sensor. The design concept can be extended to more than four absorbers per sensor. The thermal conductance between the sensor and each absorber is different by design and consequently, the pulse shapes are different depending upon which absorber the xrays are received, allowing position discrimination. A magnetic sensor was used in which a paramagnetic Au:Er temperature-sensitive material is located in a weak magnetic field. Deposition of energy from an x-ray photon causes an increase in temperature, which leads to a change of magnetization of the paramagnetic sensor, which is subsequently read out using a low noise dc-SQUID. The PoSM microcalorimeters are fully microfabricated: the Au:Er sensor is located above the meander, with a thin insulation gap in between. For this position-sensitive device, four electroplated absorbers are thermally linked to the sensor via heat links of different thermal conductance. One pixel is identical to that of a single-pixel design, consisting of an overhanging absorber fabricated directly on top of the sensor. It is therefore very strongly thermally coupled to it. The three other absorbers are supported directly on a silicon-nitride membrane. These absorbers are thermally coupled to the sensor via Ti (5 nm)/Au250 nm) metal links. The strength of the links is parameterized by the number of gold squares making up the link. For detector performance, experimentally different pulse-shapes were demonstrated with 6 keV x-rays, which clearly show different rise times for different absorber positions. For energy resolution measurement, the PoSM was operated at 32 mK with an applied field that was generated using a persistent current of 50 mA. Over the four pixels, energy resolution ranges from 4.4 to 4.7 eV were demonstrated.

Bandler, SImon↗

SLAC microresonator RF(SMuRF) electronics: A tone-tracking readout system for superconducting microwave resonator arrays

Here, we describe the newest generation of the SLAC Microresonator RF (SMuRF) electronics, a warm digital control and readout system for microwave-frequency resonator-based cryogenic detector and multiplexer systems, such as microwave superconducting quantum interference device multiplexers (μmux) or microwave kinetic inductance detectors. Ultra-sensitive measurements in particle physics and astronomy increasingly rely on large arrays of cryogenic sensors, which in turn necessitate highly multiplexed readout and accompanying room-temperature electronics. Microwave-frequency resonators are a popular tool for cryogenic multiplexing, with the potential to multiplex thousands of detector channels on one readout line. The SMuRF system provides the capability for reading out up to 3328 channels across a 4–8 GHz bandwidth. Notably, the SMuRF system is unique in its implementation of a closed-loop tone-tracking algorithm that minimizes RF power transmitted to the cold amplifier, substantially relaxing system linearity requirements and effective noise from intermodulation products. Here, we present a description of the hardware, firmware, and software systems of the SMuRF electronics, comparing achieved performance with science-driven design requirements. In particular, we focus on the case of large-channel-count, low-bandwidth applications, but the system has been easily reconfigured for high-bandwidth applications. The system described here has been successfully deployed in lab settings and field sites around the world and is baselined for use on upcoming large-scale observatories.

47 OTHER INSTRUMENTATION↗

Characterization of Aliased Noise in the Advanced ACTPol Receiver

Advanced ACTPol is the second-generation polarization-sensitive upgrade to the 6m aperture Atacama Cosmology Telescope (ACT), which increased detector count and frequency coverage compared to the previous ACTPol receiver. Advanced ACTPol utilizes a new two-stage time-division multiplexing readout architecture based on superconducting quantum interference devices to achieve a multiplexing factor as high as 64 (rows), fielding a 2012 detector camera at 150/220 GHz and two 90/150 GHz cameras containing 1716 detectors each. In a time-domain system, aliasing introduces noise to the readout. Here in this work we present a figure of merit to measure this noise contribution and present measurements of the aliased noise fraction of the Advanced ACTPol receiver as deployed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low Noise Frequency-Domain Multiplexing of TES Bolometers Using SQUIDs at Sub-Kelvin Temperature

Digital Frequency-Domain Multiplexing (DfMux) is a technique that uses MHz superconducting resonators and Superconducting Quantum Interference Device (SQUID) arrays to read out sets of transition edge sensors. DfMux has been used by several Cosmic Microwave Background experiments, including most recently POLARBEAR-2 and SPT-3 G with multiplexing factors as high as 68, and is the baseline readout technology for the planned satellite mission LiteBIRD. Here, we present recent work focused on improving DfMux readout noise, reducing parasitic impedance, and improving sensor operation. We have achieved a substantial reduction in stray impedance by integrating the sensors, resonators, and SQUID array onto a single-carrier board operated at 250 mK. This also drastically simplifies the packaging of the cryogenic components and leads to better-controlled crosstalk. We demonstrate a low readout noise level of 8.6 pA/Hz1 1/2 , which was made possible by operating the SQUID array at a reduced temperature and with a low dynamic impedance. This is a factor of two improvement compared to the achieved readout noise level in currently operating Cosmic Microwave Background experiments using DfMux and represents a critical step toward maturation of the technology for the next generation of instruments.

47 OTHER INSTRUMENTATION↗

Geometric control of magnetic domain morphology in electrodeposited Ni rich NiPt mesoscopic wires

In this paper, we study the electrodeposited Ni—Pt magnetic wires, exploring the mechanisms by which changes in geometry and composition influence the local magnetic structure. The samples were prepared by electrodeposition, their elemental composition was analyzed by energy dispersive X-ray spectroscopy, and phase analysis was carried out by an X-ray diffraction measurement. Magnetic force microscopy measurements, and magnetic force microscopy measurements in magnetic field were carried out to study the domain morphology of the prepared samples. Magnetization characteristics were measured via vibrating sample magnetometry mode of a superconducting quantum interference device. Here, the results were analyzed and compared with micromagnetic simulations. It is shown that a strong perpendicular magnetic anisotropy is responsible for the characteristic checkerboard-like surface magnetization patterns, which can be tuned by geometrical constriction and Ni content. Understanding these relationships provides insights into the design of magnetic materials with tailored properties for advanced applications, like magnetic sensors.

Binary alloy↗

Preparation of ternary hydrophobic magnetic deep eutectic solvents and an investigation into their physicochemical properties

Hydrophobic magnetic deep eutectic solvents (HMDESs) are considered a subclass of DESs comprised of a hydrogen bond acceptor (HBA), hydrogen bond donor (HBD), and a metal halide salt. These DESs can be easily manipulated by an external magnet and employed in numerous applications including liquid–liquid extractions and catalysis. In this work, a total of forty-six (46) HMDESs were prepared and their physicochemical properties studied. Six structurally unique ionic and non-ionic HBAs were combined with lanthanide and transition metal halide salts and twelve different HBDs to prepare room temperature eutectic solvents. The viscosities of HMDESs ranged from 46 centipoise (cP) to 124,600 cP at 23 °C. Their magnetic susceptibilities, studied by superconducting quantum interference device (SQUID) magnetometry and a magnetic susceptibility balance, varied from 3.03 Bohr magnetons (μB) to 9.32 μB when the type of metal halide salt and its molar ratio were varied. Thermal stabilities ranged from 151.1 °C to 308.5 °C at 5% mass loss. Further, all HMDESs comprised of ionic HBA were observed to be insoluble in hexane. This study demonstrates that the physicochemical properties of HMDESs can easily be tailored by varying the DES constituents as well as their molar ratio. The structural tunability of these solvents make them highly attractive candidates for a plethora of applications ranging from extractions to electrochromic applications, where HMDESs can be easily manipulated by an external magnetic field.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Discrete Open-Shell Tris(bipyridinium radical cationic) Inclusion Complexes in the Solid State

In the solid state the properties of organic radicals depend heavily on radical-radical interactions that are influenced by the superstructure of the crystalline phase. Here, we report the synthesis and characterization of a substituted tetracationic cyclophane, cyclobis(paraquat-p-1,4- dimethoxyphenylene), and outline how its bisradical dicationic redox state associates with the methyl viologen radical cation (MV •+ ) to give a trisradical tricationic inclusion complex. The (super)structures of the reduced cyclophane and this 1:1 complex in the solid-state deviate from the analogous (super)structures observed for the reduced state of cyclobis(paraquat-p-phenylene) and that of its trisradical tricationic complex. Titration experiments with a range of guests reveal that the methoxy substituents on the para-xylenyl do not influence significantly of the binding affinity of the cyclophane for small neutral guests, whereas the affinity decreases by an order of magnitude for larger radical cationic guests such as MV •+ . X-Ray diffraction reveals that the solid- state structures of the tricationic trisradical complexes to be a discrete entity with weak intermolecular orbital overlap between the neighboring complexes. Transient nutation EPR experiment and DFT calculations confirm that the complex has a doublet spin configuration in the ground state as a result of the strong orbital overlap within the complex, while the quartet-state spin configuration is higher in energy and so is inaccessible at ambient temperature. The superconducting quantum interference device (SQUID) measurement reveals that trisradical tricationic complexes interact antiferromagnetically (J/k = - 2.33 K) and form a 1D Heisenberg antiferromagnetic chain along the a-axis in the crystal. Furthermore, these results offer new insights into the design and synthesis of organic magnetic materials based on host-guest inclusion complexes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetic Blocking in Fluoflavine Radical-Bridged Dilanthanide Complexes

Magnetic exchange coupling is difficult to foster in polynuclear lanthanide (Ln) complexes and poorly understood. While coupling Ln ions through closed-shell ligands is inherently weak due to the contracted 4f orbitals, placing open-shell ligands instead has proven to promote orders of magnitude stronger coupling, giving rise to single-molecule magnets (SMMs) innate to real magnetic memory effect in the case of the anisotropic Ln ions. Notably, the impact of radical bridges with differing oxidation states on magnetic blocking remains unexplored due to lack of Ln SMMs with radicals in two distinct charge states. Herein, the first dilanthanide complexes (Ln = Gd, Dy) containing fluoflavine (flv) bridges, [(Cp* 2 Ln) 2 (μ-flv z )]X, (where X = [Al(OC{CF 3 } 3 ) 4 ] − (z = 1−•), 1-Ln; X = 0 (z = 2−), 2-Ln; X =[K(crypt-222)] + (z = 3−•), 3-Ln) are reported. 1-Ln and 3-Ln, comprising the flv 1−• and flv 3−• radical bridges, were investigated via single-crystal X-ray diffraction (SCXRD), ultraviolet−visible (UV−vis) spectroscopy, Superconducting Quantum Interference Device (SQUID) magnetometry, high-field electron paramagnetic resonance (HF-EPR) spectroscopy and broken-symmetry density functional theory (BS-DFT) calculations. 1-Dy and 3-Dy constitute the first SMMs innate to radicals in two differing oxidation states. 1-Dy exhibits a spin-reversal barrier U eff of 28.36 cm −1 and open magnetic hysteresis loops below 3 K. By contrast, 3-Dy displays a much higher U eff of 143(2) cm −1 and open hysteresis loops until 9.5 K, representing a record for dilanthanide SMMs containing an organic radical bridge. The boost in SMM properties in 3-Dy is attributed to spin-phonon coupling and improved frontier orbital structure. This study paves the way for advanced design strategies of polynuclear Ln SMMs.

Benner, Florian [Michigan State Univ., East Lansin↗