Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Statistical calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Vhf/uhf stellar calibration error analysis.

Results of a statistical error analysis performed to determine the degree of uncertainty encountered when calibrating steerable vhf/uhf receiving antennas with the stellar calibration method. The analysis considers the propagation of precision error indices. It is shown that an antenna gain calibration by the stellar method has a one-sigma (1 sigma) uncertainty of plus or minus 0.65 dB at 1440 MHz (L-band), and plus or minus 0.8 dB (1 sigma) at 136 MHz (vhf). Somewhat increased precision can be achieved by monitoring the antenna gain-to-noise temperature ratio at a station; a worst-case uncertainty of plus or minus 0.4 dB (1 sigma) can be realized at both L-band and vhf. Finally, field test measurements of antenna gain, obtained at 136 MHz in the NASA space tracking and data acquisition network, demonstrate an uncertainty of plus or minus 1.0 dB or less, which effectively confirms the analytical result.

Taylor, R. E.↗

Thermocouple Calibration and Accuracy in a Materials Testing Laboratory

A consolidation of information has been provided that can be used to define procedures for enhancing and maintaining accuracy in temperature measurements in materials testing laboratories. These studies were restricted to type R and K thermocouples (TCs) tested in air. Thermocouple accuracies, as influenced by calibration methods, thermocouple stability, and manufacturer's tolerances were all quantified in terms of statistical confidence intervals. By calibrating specific TCs the benefits in accuracy can be as great as 6 C or 5X better compared to relying on manufacturer's tolerances. The results emphasize strict reliance on the defined testing protocol and on the need to establish recalibration frequencies in order to maintain these levels of accuracy.

Lerch, B. A.↗

Model Robust Calibration: Method and Application to Electronically-Scanned Pressure Transducers

This article presents the application of a recently developed statistical regression method to the controlled instrument calibration problem. The statistical method of Model Robust Regression (MRR), developed by Mays, Birch, and Starnes, is shown to improve instrument calibration by reducing the reliance of the calibration on a predetermined parametric (e.g. polynomial, exponential, logarithmic) model. This is accomplished by allowing fits from the predetermined parametric model to be augmented by a certain portion of a fit to the residuals from the initial regression using a nonparametric (locally parametric) regression technique. The method is demonstrated for the absolute scale calibration of silicon-based pressure transducers.

Walker, Eric L.↗

EFBMC

SAND2026-23986O EFBMC performs elastic Bayesian model calibration by applying Bayesian statistics and functional analysis. The software provides Python, R, and MATLAB scripts that enable users to calibrate models. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Tucker, J. Derek [Sandia National Lab. (SNL-CA), L↗

Computer Model Calibration with Time Series Data Using Deep Learning and Quantile Regression

Computer models play a key role in many scientific and engineering problems. One major source of uncertainty in computer model experiments is input parameter uncertainty. Computer model calibration is a formal statistical procedure to infer input parameters by combining information from model runs and observational data. The existing standard calibration framework suffers from inferential issues when the model output and observational data are high-dimensional dependent data, such as large time series, due to the difficulty in building an emulator and the nonidentifiability between effects from input parameters and data-model discrepancy. To overcome these challenges, we, in this work, propose a new calibration framework based on a deep neural network (DNN) with long short-term memory layers that directly emulates the inverse relationship between the model output and input parameters. Adopting the “learning with noise” idea, we train our DNN model to filter out the effects from data-model discrepancy on input parameter inference. We also formulate a new way to construct interval predictions for DNN using quantile regression to quantify the uncertainty in input parameter estimates. Through a simulation study and real data application with the Weather Research and Forecasting Model Hydrological modeling system (WRF-Hydro), we show our approach can yield accurate point estimates and well-calibrated interval estimates for input parameters.

97 MATHEMATICS AND COMPUTING↗

Radiometric performance of AVIRIS: Assessment for an arid region geologic target

Data from several AVIRIS flight lines were examined to assess instrument stability and response. Both scene and in-flight calibration data were analyzed statistically. The data clearly indicates that, although the instrument output was noisy and unstable at the time of the data acquisition, valuable spectral signatures can still be extracted and analyzed. Some first order calibration corrections can be performed by forcing internal consistency within the data. AVIRIS data are delivered in band-interleaved-by-line format, but high efficiency routines were developed which access the data as either image or spectral planes and enable effective statistical and visual examination of both AVIRIS scenes and ancillary files. Two methods were used to extract spectral information from segment 4 of the Kelso Dunes flight. Both successfully identified at least three distinct spectral signatures, but neither has positively identified a specific material.

Kieffer, Hugh H.↗

Design and Calibration of the X-33 Flush Airdata Sensing (FADS) System

This paper presents the design of the X-33 Flush Airdata Sensing (FADS) system. The X-33 FADS uses a matrix of pressure orifices on the vehicle nose to estimate airdata parameters. The system is designed with dual-redundant measurement hardware, which produces two independent measurement paths. Airdata parameters that correspond to the measurement path with the minimum fit error are selected as the output values. This method enables a single sensor failure to occur with minimal degrading of the system performance. The paper shows the X-33 FADS architecture, derives the estimating algorithms, and demonstrates a mathematical analysis of the FADS system stability. Preliminary aerodynamic calibrations are also presented here. The calibration parameters, the position error coefficient (epsilon), and flow correction terms for the angle of attack (delta alpha), and angle of sideslip (delta beta) are derived from wind tunnel data. Statistical accuracy of' the calibration is evaluated by comparing the wind tunnel reference conditions to the airdata parameters estimated. This comparison is accomplished by applying the calibrated FADS algorithm to the sensed wind tunnel pressures. When the resulting accuracy estimates are compared to accuracy requirements for the X-33 airdata, the FADS system meets these requirements.

Whitmore, Stephen A.↗

Multi-Axis Accelerometer Calibration System

A low-cost, portable, and simplified system has been developed that is suitable for in-situ calibration and/or evaluation of multi-axis inertial measurement instruments. This system overcomes facility restrictions and maintains or improves the calibration quality for users of accelerometer-based instruments with applications in avionics, experimental wind tunnel research, and force balance calibration applications. The apparatus quickly and easily positions a multi-axis accelerometer system into a precisely known orientation suitable for in-situ quality checks and calibration. In addition, the system incorporates powerful and sophisticated statistical methods, known as response surface methodology and statistical quality control. These methods improve calibration quality, reduce calibration time, and allow for increased calibration frequency, which enables the monitoring of instrument stability over time.

Finley, Tom↗

Use of Vertically Integrated Ice in WRF-Based Forecasts of Lightning Threat

Previously reported methods of forecasting lightning threat using fields of graupel flux from WRF simulations are extended to include the simulated field of vertically integrated ice within storms. Although the ice integral shows less temporal variability than graupel flux, it provides more areal coverage, and can thus be used to create a lightning forecast that better matches the areal coverage of the lightning threat found in observations of flash extent density. A blended lightning forecast threat can be constructed that retains much of the desirable temporal sensitivity of the graupel flux method, while also incorporating the coverage benefits of the ice integral method. The graupel flux and ice integral fields contributing to the blended forecast are calibrated against observed lightning flash origin density data, based on Lightning Mapping Array observations from a series of case studies chosen to cover a wide range of flash rate conditions. Linear curve fits that pass through the origin are found to be statistically robust for the calibration procedures.

McCaul, E. W., jr.↗

Statistical Downscaling of Climate Models for Solar Resource Assessment

This study presents the development of statistical models to efficiently downscale future projections of solar irradiance for solar energy applications. A climate data set simulated from a Regional Climate Model (RCM) obtained from the North American Coordinated Regional Climate Downscaling Experiment (NA-CORDEX) is selected as input to the statistical models to create high-resolution global horizontal irradiance (GHI) over the contiguous United States (CONUS). Our approach builds statistical downscaling models that (1) regrid RCM data (0.22 degree and daily spatiotemporal resolution), (2) correct bias of GHI projections, (3) downscale the future GHI project from daily-scale to hourly-scale, and (4) spatially downscale to generate GHI at 8-km resolution. To calibrate and validate the statistical models, we adapt and use the National Solar Radiation Database (NSRDB). Preliminary results show that the statistical downscaling approach downscales future projections of GHI under two climate scenarios (RCP4.5 and RCP8.5) with a nBIAS of 3%, nMAE of 34% and nRMSE of 46% estimated against NSRDB for the contiguous United State. This presentation will summarize the implemented methodology and validation results as well as future extension of this research.

climate data↗

Estimating the urban bias of surface shelter temperatures using upper-air and satellite data. Part 1: Development of models predicting surface shelter temperatures

Multiple regression techniques were used to predict surface shelter temperatures based on the time period 1986-89 using upper-air data from the European Centre for Medium-Range Weather Forecasts (ECMWF) to represent the background climate and site-specific data to represent the local landscape. Global monthly mean temperature models were developed using data from over 5000 stations available in the Global Historical Climate Network (GHCN). Monthly maximum, mean, and minimum temperature models for the United States were also developed using data from over 1000 stations available in the U.S. Cooperative (COOP) Network and comparative monthly mean temperature models were developed using over 1150 U.S. stations in the GHCN. Three-, six-, and full-variable models were developed for comparative purposes. Inferences about the variables selected for the various models were easier for the GHCN models, which displayed month-to-month consistency in which variables were selected, than for the COOP models, which were assigned a different list of variables for nearly every month. These and other results suggest that global calibration is preferred because data from the global spectrum of physical processes that control surface temperatures are incorporated in a global model. All of the models that were developed in this study validated relatively well, especially the global models. Recalibration of the models with validation data resulted in only slightly poorer regression statistics, indicating that the calibration list of variables was valid. Predictions using data from the validation dataset in the calibrated equation were better for the GHCN models, and the globally calibrated GHCN models generally provided better U.S. predictions than the U.S.-calibrated COOP models. Overall, the GHCN and COOP models explained approximately 64%-95% of the total variance of surface shelter temperatures, depending on the month and the number of model variables. In addition, root-mean-square errors (rmse's) were over 3 C for GHCN models and over 2 C for COOP models for winter months, and near 2 C for GHCN models and near 1.5 C for COOP models for summer months.

Epperson, David L.↗

An improved method for determining force balance calibration accuracy

The results of an improved statistical method used at Langley Research Center for determining and stating the accuracy of a force balance calibration are presented. The application of the method for initial loads, initial load determination, auxiliary loads, primary loads, and proof loads is described. The data analysis is briefly addressed.

Ferris, Alice T.↗

Calibration Modeling Methodology to Optimize Performance for Low Range Applications

Calibration is a vital process in characterizing the performance of an instrument in an application environment and seeks to obtain acceptable accuracy over the entire design range. Often, project requirements specify a maximum total measurement uncertainty, expressed as a percent of full-scale. However in some applications, we seek to obtain enhanced performance at the low range, therefore expressing the accuracy as a percent of reading should be considered as a modeling strategy. For example, it is common to desire to use a force balance in multiple facilities or regimes, often well below its designed full-scale capacity. This paper presents a general statistical methodology for optimizing calibration mathematical models based on a percent of reading accuracy requirement, which has broad application in all types of transducer applications where low range performance is required. A case study illustrates the proposed methodology for the Mars Entry Atmospheric Data System that employs seven strain-gage based pressure transducers mounted on the heatshield of the Mars Science Laboratory mission.

McCollum, Raymond A.↗

Photon calibration techniques for high resolution cryogenic detectors

Monoenergetic photons from a pulsed laser diode or LED are commonly used to calibrate the detector response of high-resolution calorimetric detectors. However, when the detector’s resolution is larger than the energy of a single photon, a calibration is normally derived using Poisson statistics. In this paper, we clarify the assumptions implicit in this calibration method, before considering how a more realistic model of a detector’s performance will violate these assumptions, biasing the calibration. Lastly, we judge the individual impact of specific detector parameters on our calibration, and conclude with discussion of both the limits of our calculations and the implications for state-of-the art detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

BICEP/ Keck XVIII: Measurement of BICEP3 polarization angles and consequences for constraining cosmic birefringence and inflation

We use a custom-made calibrator to measure individual detectors’ polarization angles of BICEP3, a small aperture telescope observing the cosmic microwave background (CMB) at 95 GHz from the South Pole. We describe our calibration strategy and the statistical and systematic uncertainties associated with the measurement. We reach an unprecedented precision for such measurement on a CMB experiment, with a repeatability for each detector pair of 0.02°. Here, we show that the relative angles measured using this method are in excellent agreement with those extracted from CMB data. Because the absolute measurement is currently limited by a systematic uncertainty, we do not derive cosmic birefringence constraints from BICEP3 data in this work. Rather, we forecast the sensitivity of BICEP3 sky maps for such analysis. We investigate the relative contributions of instrument noise, lensing, and dust, as well as astrophysical and instrumental systematics. We also explore the constraining power of different angle estimators, depending on analysis choices. We establish that the BICEP3 2-year dataset (2017–2018) has an on-sky sensitivity to the cosmic birefringence angle of 𝜎 𝛼 = 0.07⁢8°, which could be improved to 𝜎 𝛼 = 0.05⁢5° by adding all of the existing BICEP3 data (through 2023). Furthermore, we emphasize the possibility of using the BICEP3 sky patch as a polarization calibration source for CMB experiments, which with the present data could reach a precision of 0.035°. Finally, in the context of inflation searches, we investigate the impact of detector-to-detector variations in polarization angles as they may bias the tensor-to-scalar ratio 𝑟. We show that while the effect is expected to remain subdominant to other sources of systematic uncertainty, it can be reliably calibrated using polarization angle measurements such as the ones we present in this paper.

Cosmic microwave background↗

Detached-Eddy Simulation Based on the V2-F Model

Detached-eddy simulation (DES) based on the v(sup 2)-f Reynolds-averaged Navier-Stokes (RANS) model is developed and tested. The v(sup 2)-f model incorporates the anisotropy of near-wall turbulence which is absent in other RANS models commonly used in the DES community. The v(sup 2)-f RANS model is modified in order the proposed v(sup 2)-f-based DES formulation reduces to a transport equation for the subgrid-scale kinetic energy isotropic turbulence. First, three coefficients in the elliptic relaxation equation are modified, which is tested in channel flows with friction Reynolds number up to 2000. Then, the proposed v(sup 2)-f DES model formulation is derived. The constant, C(sub DES), required in the DES formulation was calibrated by simulating both decaying and statistically-steady isotropic turbulence. After C(sub DES) was calibrated, the v(sub 2)-f DES formulation is tested for flow around a circular cylinder at a Reynolds number of 3900, in which case turbulence develops after separation. Simulations indicate that this model represents the turbulent wake nearly as accurately as the dynamic Smagorinsky model. Spalart-Allmaras-based DES is also included in the cylinder flow simulation for comparison.

Jee, Sol Keun↗

Radioactive Source Localization via Bayesian Particle Filter

In the event of a misplaced radioactive source or other emergency situation, measuring a radiation field, mapping its distribution, and determining a source location are essential tasks to ameliorating the situation. However, radiation fields may be extremely hazardous to human surveyors and minimizing received radiation doses is just as essential. Robots appear to be a potential solution to these problems. Beyond simply measuring radiation, the robot's computer processing capabilities offer a way to apply complex data analysis methods to radiation measurements in real-time. Methods which predict likely source locations can then feed this information into other processes, potentially improving path planning and enabling more efficient measurements. Given a robot mounted with a gamma-ray detector, can we: develop a methodology to account for detector performance across a wide range of source angles, distances, and photon energies? operate an autonomously navigating robot to effectively survey and characterize an area of interest? implement a data analysis method, conventionally used in measurements of motion, for source localization purposes? An open-source TurtleBot 3 robot, running Robot Operating System (ROS) on Ubuntu 16.04 LTS, was fitted with a Kromek GR1{sup R} Cadmium Zinc Telluride (CZT) solid-state gamma-ray detector. As a part of ROS, the packages OpenSlam, gmapping, and amcl were used to perform Simultaneous Localization and Mapping (SLAM), determining the robot's position and mapping the surrounding area. Data was acquired via Lidar mounted on top the TurtleBot 3. Detector Calibration Fit: The equation was fit to 365 counts of various energies, distances, and angles. A MATLAB{sup R} program was written to simulate measurements taken a robot on a random walk, with count data and positions discretized into finite element pixels. Using this program, a sample of 100 runs was performed on a map with a simulated source at the center, with a total of 200 of 2 pixels each. Similarly, multiple runs of the filter were performed on recorded robot measurement data. In both simulation and real tests, when corrected for errors (particles placed outside of bounds or on the robot, and simulation-specific errors), corresponding t-tests of predicted x and y-coordinates were within a 95% confidence interval of the actual position. For the real trial, these positions are slightly skewed right in the x-axis as the robot remained mainly to the left side of the source within the sample area. These simulations demonstrate potential validity for the usage of a particle filter as method of radioactive source localization. In the future, true real-time implementation and data fusion may further augment the performance of the robot to localize lost sources. Additionally, identification of multiple sources, determination of source types, and usage of a collimator are areas to potentially be explored.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

GEANT4 parameter tuning using Professor

The GEANT4 toolkit is used extensively in high energy physics to simulate the passage of particles through matter and to predict effects such as detector efficiencies and smearing. GEANT4 uses many underlying models to predict particle interaction kinematics, and uncertainty in these models leads to uncertainty in high energy physics measurements. The GEANT4 collaboration recently made free parameters in some models accessible through partnership with GEANT4 developers. We present a study of the impact of varying parameters in three GEANT4 hadronic physics models on agreement with thin target datasets and describe fits to these datasets using the Professor model tuning framework [1]. We find that varying parameters produces substantially better agreement with some datasets, but that more degrees of freedom are required for full agreement. This work is a first step towards a common framework for propagating uncertainties in GEANT4 models to high energy physics measurements, and we outline future work required to complete that goal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗