Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectral mixture analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Time-resolved temperature study in a high-power impulse magnetron sputtering discharge

The gas heating dynamics is studied in a high-power impulse magnetron sputtering discharge operating in Ar-N{sub 2} gas mixtures. The time-resolved rotational temperature analysis based on the spectral transition between the B{sup 2}{Sigma}{sub u}{sup +}-X{sup 2}{Sigma}{sub g}{sup +} energy levels in molecular nitrogen ion (N{sub 2}{sup +} First Negative Band) is undertaken for this purpose. The rotational temperature in the discharge is found to increase linearly during the plasma pulse being roughly independent on the nitrogen content in the examined range. Such a temperature increase is attributed to the bulk gas heating which is the result of collisions with the sputtered species. Two sputtered materials, Ti and W, are examined during the study. In the case of W sputtering, the gas heating is found to be more pronounced than in the Ti case, which is explained by more efficient energy exchange between the sputtered W atoms and the bulk gas atoms during the plasma on-time. The obtained temperature data are compared to the laser-induced fluorescence study of Ar metastable atoms performed recently in the same discharge in our group. The particularities related to gas thermalization as well as to validity of the utilized approach for characterization of the pulsed sputtering discharges are discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Evaluation of Characterization Techniques for Iron Pipe Corrosion Products and Iron Oxide Thin Films

A common problem faced by drinking water studies is that of properly characterizing the corrosion products (CP) in iron pipescor synthetic Fe (hydr)oxides used to simulate the iron pipe used in municipal drinking-water systems. The present work compares the relative applicability of a suite of imaging and analytical techniques for the characterization of CPs and synthetic Fe oxide thin films and provide an overview of the type of data that each instrument can provide as well as their limitations to help researchers and consultants choose the best technique for a given task. Crushed CP from a water distribution system and synthetic Fe oxide thin films formed on glass surfaces were chosen as test samples for this evaluation. The CP and synthetic Fe oxide thin films were analyzed by atomic force microscopy (AFM), scanning electron microscopy (SEM), energy-dispersive spectroscopy, time-of-flight secondary ion mass spectrometry (ToF-SIMS), X-ray powder diffractometry (XRD), grazing incident diffractometry (GID), transmission electron microscopy (TEM), selected area electron diffraction, X-ray photoelectron spectroscopy (XPS), Fourier transform infrared, Mössbauer spectroscopy, Brunauer-Emmett-Teller N2 adsorption and Fe concentration was determined by the ferrozine method. XRD and GID were found to be the most suitable techniques for identification of the mineralogical composition of CP and synthetic Fe oxide thin films, respectively. AFM and a combined ToF-SIMS-AFM approach proved excellent for roughness and depth profiling analysis of synthetic Fe oxide thin films, respectively. Corrosion products were difficult to study by AFM due to their surface roughness, while synthetic Fe oxide thin films resisted most spectroscopic methods due to their limited thickness (118 nm). XPS analysis is not recommended for mixtures of Fe (hydr)oxides due to their spectral similarities. SEM and TEM provided great detail on mineralogical morphology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A semiempirical method for analysis of the reflectance spectra of binary mineral mixtures

A simple semiempirical method is presented for determination of the spectral reflectance of a powdered binary mineral mixture. This technique uses a two-stream radiative transfer model (a modified Kubelka-Munk model) on a particulate medium of isotroic scatterers The particles are assumed to be much larger than the wavelength of light under consideration. This same method can be used to determine the relative proportion of components in a mixture for which the spectral reflectance is known. Binary mixtures of olivine, two pyroxenes, and magnetite are used to test this model. The theoretical and empirical results agree approximately within experimental errors.

Johnson, P. E.↗

Geometrical description in binary composites and spectral density representation

In this review, the dielectric permittivity of dielectric mixtures is discussed in view of the spectral density representation method. A distinct representation is derived for predicting the dielectric properties, permittivities {var_epsilon}, of mixtures. The presentation of the dielectric properties is based on a scaled permittivity approach, {zeta} = ({var_epsilon}{sub e} - {var_epsilon}{sub m})({var_epsilon}{sub i} - {var_epsilon}{sub m}){sup -1}, where the subscripts e, m and i denote the dielectric permittivities of the effective, matrix and inclusion media, respectively [Tuncer, E. J. Phys.: Condens. Matter 2005, 17, L125]. This novel representation transforms the spectral density formalism to a form similar to the distribution of relaxation times method of dielectric relaxation. Consequently, I propose that any dielectric relaxation formula, i.e., the Havriliak-Negami empirical dielectric relaxation expression, can be adopted as a scaled permittivity. The presented scaled permittivity representation has potential to be improved and implemented into the existing data analyzing routines for dielectric relaxation; however, the information to extract would be the topological/morphological description in mixtures. To arrive at the description, one needs to know the dielectric properties of the constituents and the composite prior to the spectral analysis. To illustrate the strength of the representation and confirm the proposed hypothesis, the Landau-Lifshitz/Looyenga (LLL) [Looyenga, H. Physica 1965, 31, 401] expression is selected. The structural information of a mixture obeying LLL is extracted for different volume fractions of phases. Both an in-house computational tool based on the Monte Carlo method to solve inverse integral transforms and the proposed empirical scaled permittivity expression are employed to estimate the spectral density function of the LLL expression. The estimated spectral functions for mixtures with different inclusion concentration compositions show similarities; they are composed of a couple of bell-shaped distributions, with coinciding peak locations but different heights. It is speculated that the coincidence in the peak locations is an absolute illustration of the self-similar fractal nature of the mixture topology (structure) created with the LLL expression. Consequently, the spectra are not altered significantly with increased filler concentration level - they exhibit a self-similar spectral density function for different concentration levels. Last but not least, the estimated percolation strengths also confirm the fractal nature of the systems characterized by the LLL mixture expression. It is concluded that the LLL expression is suitable for complex composite systems that have hierarchical order in their structure. These observations confirm the finding in the literature.

36 MATERIALS SCIENCE↗

Chemometric and Statistical Analyses of ToF-SIMS Spectra of Increasingly Complex Biological Samples

Characterizing and classifying molecular variation within biological samples is critical for determining fundamental mechanisms of biological processes that will lead to new insights including improved disease understanding. Towards these ends, time-of-flight secondary ion mass spectrometry (ToF-SIMS) was used to examine increasingly complex samples of biological relevance, including monosaccharide isomers, pure proteins, complex protein mixtures, and mouse embryo tissues. The complex mass spectral data sets produced were analyzed using five common statistical and chemometric multivariate analysis techniques: principal component analysis (PCA), linear discriminant analysis (LDA), partial least squares discriminant analysis (PLSDA), soft independent modeling of class analogy (SIMCA), and decision tree analysis by recursive partitioning. PCA was found to be a valuable first step in multivariate analysis, providing insight both into the relative groupings of samples and into the molecular basis for those groupings. For the monosaccharides, pure proteins and protein mixture samples, all of LDA, PLSDA, and SIMCA were found to produce excellent classification given a sufficient number of compound variables calculated. For the mouse embryo tissues, however, SIMCA did not produce as accurate a classification. The decision tree analysis was found to be the least successful for all the data sets, providing neither as accurate a classification nor chemical insight for any of the tested samples. Based on these results we conclude that as the complexity of the sample increases, so must the sophistication of the multivariate technique used to classify the samples. PCA is a preferred first step for understanding ToF-SIMS data that can be followed by either LDA or PLSDA for effective classification analysis. This study demonstrates the strength of ToF-SIMS combined with multivariate statistical and chemometric techniques to classify increasingly complex biological samples. Applying these techniques to information-rich mass spectral data sets opens the possibilities for new applications including classification of subtly different biological samples that may provide insights into cellular processes, disease progress, and disease diagnosis.

59 BASIC BIOLOGICAL SCIENCES↗

Deciphering phase evolution in complex metal oxide thin films via high-throughput materials synthesis and characterization

Discovery of structure-property relationships in thin film alloys of complex metal oxides enabled by high-throughput materials synthesis and characterization facilities is demonstrated here with a case-study. In this study, thin films of binary transition metal oxides (Ti–Zn) are prepared by pulsed laser deposition with continuously varying Ti:Zn ratio, creating combinatorial samples for exploration of the properties of this material family. The atomic structure and electronic properties are probed by spatially resolved techniques including x-ray absorption near edge structures (XANES) and x-ray fluorescence (XRF) at the Ti and Zn K-edge, x-ray diffraction, and spectroscopic ellipsometry. The observed properties as a function of Ti:Zn ratio are resolved into mixtures of five distinguishable phases by deploying multivariate curve resolution analysis on the XANES spectral series, under constraints set by results from the other characterization techniques. First-principles computations based on density function theory connect the observed properties of each distinct phase with structural and spectral characteristics of crystalline polymorphs of Ti–Zn oxide. Continuous tuning of the optical absorption edge as a function of Ti:Zn ratio, including the unusual observation of negative optical bowing, exemplifies a functional property of the film correlated to the phase evolution.

36 MATERIALS SCIENCE↗

Spectral-compositional variations in the constituent minerals of mafic and ultramafic assemblages and remote sensing implications

Chemical compositions of the constituent minerals of 13 mafic and ultramafic assemblages containing from one to five mineral components were analyzed with an electron microprobe, and the compositions were correlated with the reflectance spectra of the samples to determine the spectral-compositional relationships of these assemblages. Results indicate that, as more components are added to a mixture, the quality and quantity of compositional information which can be derived from spectral analysis diminishes. It is shown that opaque minerals (such as magnetite for terrestrial occurrences and ilmenite in lunar assemblages) influence reflectance spectra out of proportion to their abundances, reducing overall reflectance and band depths of mafic silicates in small dispersed amounts.

Cloutis, Edward A.↗

Prediction of the Cu oxidation state from EELS and XAS spectra using supervised machine learning

Abstract Electron energy loss spectroscopy (EELS) and X-ray absorption spectroscopy (XAS) provide detailed information about bonding, distributions and locations of atoms, and their coordination numbers and oxidation states. However, analysis of XAS/EELS data often relies on matching an unknown experimental sample to a series of simulated or experimental standard samples. This limits analysis throughput and the ability to extract quantitative information from a sample. In this work, we have trained a random forest model capable of predicting the oxidation state of copper based on its L-edge spectrum. Our model attains an R 2 score of 0.85 and a root mean square error of 0.24 on simulated data. It has also successfully predicted experimental L-edge EELS spectra taken in this work and XAS spectra extracted from the literature. We further demonstrate the utility of this model by predicting simulated and experimental spectra of mixed valence samples generated by this work. This model can be integrated into a real-time EELS/XAS analysis pipeline on mixtures of copper-containing materials of unknown composition and oxidation state. By expanding the training data, this methodology can be extended to data-driven spectral analysis of a broad range of materials.

36 MATERIALS SCIENCE↗

Near-IR laser-based spectrophotometer for comparative analysis of isotope content of CO{sub 2} in exhale air samples

We present a laser spectrophotometer aimed at high-accuracy comparative analysis of content of {sup 12}CO{sub 2} and {sup 13}CO{sub 2} isotope modifications in the exhale air samples and based on a tunable near-IR diode laser (2.05 {mu}m). The two-channel optical scheme of the spectrophotometer and the special digital system for its control are described. An algorithm of spectral data processing aimed at determining the difference in the isotope composition of gas mixtures is proposed. A few spectral regions (near 4880 cm{sup -1}) are determined to be optimal for analysis of relative content of {sup 12}CO{sub 2} and {sup 13}CO{sub 2} in the exhale air. The use of the proposed spectrophotometer scheme and the developed algorithm makes the results of the analysis less susceptible to the influence of the interference in optical elements, to the absorption in the open atmosphere, to the slow drift of the laser pulse envelope, and to the offset of optical channels. The sensitivity of the comparative analysis of the isotope content of CO{sub 2} in exhale air samples, achieved using the proposed scheme, is estimated to be nearly 0.1 Per-Mille-Sign .

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparing soil boundaries delineated by digital analysis of multispectral scanner data from high and low spatial resolution systems

The author has identified the following significant results. Computer-aided analysis techniques used with aircraft MSS data showed that the spatial resolution was sufficient to recognize each soil mapping unit of the test site. Some difficulties occurred where different soil series were intricately mixed, and this mixture showed as a separate spectral mapping unit, or where the difference between two soils depended on the depth of silty surface material. Analysis of LANDSAT data with computer-aided techniques showed that it was not possible to find spectrally homogeneous soil features of the seven soil series on the 40 ha test site on the digital display or on a picture print map. Cluster techniques could be used on an extended test area to group spectrally similar data points into cluster classes.

Kristof, S. J.↗

Joint M3 and Diviner Analysis of the Mineralogy, Glass Composition, and Country Rock Content of Pyroclastic Deposits in Oppenheimer Crater

Here we present our analysis of the near- and mid-infrared spectral properties of pyroclastic deposits within the floor fractured Oppenheimer Crater that are hypothesized to be Vulcanian in origin. These are the first results of our global study of lunar pyroclastic deposits aimed at constraining the range of eruption processes on the Moon. In the near-infrared, we have employed a new method of spectral analysis developed in Horgan et al. (2013) of the 1 m iron absorption band in Chandrayaan-1 Moon Mineralogy Mapper (M3) spectra. By analyzing both the position and shape of the 1 m band we can detect and map the distribution of minerals, glasses, and mixtures of these phases in pyroclastic deposits. We are also using mid-infrared spectra from the Lunar Reconnaissance Orbiter Diviner Lunar Radiometer Experiment to develop ~200 m/pixel Christiansen Feature (CF) maps, which correlate with silica abundance. One of the benefits of using CF maps for analysis of pyroclastic deposits is that they can be used to detect silicic country rock that may have been emplaced by Vulcanian-style eruptions, and are sensitive to iron abundance in glasses, neither of which is possible in the near-infrared. M3 analysis reveals that the primary spectral endmembers are low-calcium pyroxene and iron-bearing glass, with only minor high-calcium pyroxene, and no detectable olivine. The large deposit in the south shows higher and more extensive glass concentrations than the surrounding deposits. We interpret the M3 spectra of the pyroclastic deposits as indicating a mixture of low-calcium pyroxene country rock and juvenile glass, and no significant olivine. Analysis of Diviner CF maps of the Oppenheimer crater floor indicates an average CF value of 8.16, consistent with a mixture of primarily plagioclase and some pyroxene. The average CF values of the pyroclastic deposits range from 8.31 in the SW to 8.24 in the SE. Since CF values within the deposits are as high as 8.49, the lower average CF values of the deposits suggest that each deposit is a mixture of crater floor material and highly mafic juvenile material consistent with either olivine or Fe-bearing pyroclastic glass. Synthesizing our M3 and Diviner results indicates that the crater floor consists of plagioclase with some pyroxene, and the pyroclastic deposits are a mix of this substrate and a glass-rich juvenile material. While we cannot determine the iron content of the glass from M3 spectra alone, the high Diviner CF values suggest that the glass is relatively iron-rich. Indeed, FeO abundances inferred from CF values using the method of Allen et al. (2012) imply that the large southern deposit exhibits a significant enhancement in iron content. This supports our hypothesis that the glass in this deposit is relatively iron-rich.

Bennett, Kristen A.↗

Low-Cost Evaluation of EO-1 Hyperion and ALI for Detection and Biophysical Characterization of Forest Logging in Amazonia (NCC5-481)

Major uncertainties exist regarding the rate and intensity of logging in tropical forests worldwide: these uncertainties severely limit economic, ecological, and biogeochemical analyses of these regions. Recent sawmill surveys in the Amazon region of Brazil show that the area logged is nearly equal to total area deforested annually, but conversion of survey data to forest area, forest structural damage, and biomass estimates requires multiple assumptions about logging practices. Remote sensing could provide an independent means to monitor logging activity and to estimate the biophysical consequences of this land use. Previous studies have demonstrated that the detection of logging in Amazon forests is difficult and no studies have developed either the quantitative physical basis or remote sensing approaches needed to estimate the effects of various logging regimes on forest structure. A major reason for these limitations has been a lack of sufficient, well-calibrated optical satellite data, which in turn, has impeded the development and use of physically-based, quantitative approaches for detection and structural characterization of forest logging regimes. We propose to use data from the EO-1 Hyperion imaging spectrometer to greatly increase our ability to estimate the presence and structural attributes of selective logging in the Amazon Basin. Our approach is based on four "biogeophysical indicators" not yet derived simultaneously from any satellite sensor: 1) green canopy leaf area index; 2) degree of shadowing; 3) presence of exposed soil and; 4) non-photosynthetic vegetation material. Airborne, field and modeling studies have shown that the optical reflectance continuum (400-2500 nm) contains sufficient information to derive estimates of each of these indicators. Our ongoing studies in the eastern Amazon basin also suggest that these four indicators are sensitive to logging intensity. Satellite-based estimates of these indicators should provide a means to quantify both the presence and degree of structural disturbance caused by various logging regimes. Our quantitative assessment of Hyperion hyperspectral and ALI multi-spectral data for the detection and structural characterization of selective logging in Amazonia will benefit from data collected through an ongoing project run by the Tropical Forest Foundation, within which we have developed a study of the canopy and landscape biophysics of conventional and reduced-impact logging. We will add to our base of forest structural information in concert with an EO-1 overpass. Using a photon transport model inversion technique that accounts for non-linear mixing of the four biogeophysical indicators, we will estimate these parameters across a gradient of selective logging intensity provided by conventional and reduced impact logging sites. We will also compare our physical ly-based approach to both conventional (e.g., NDVI) and novel (e.g., SWIR-channel) vegetation indices as well as to linear mixture modeling methods. We will cross-compare these approaches using Hyperion and ALI imagers to determine the strengths and limitations of these two sensors for applications of forest biophysics. This effort will yield the first physical ly-based, quantitative analysis of the detection and intensity of selective logging in Amazonia, comparing hyperspectral and improved multi-spectral approaches as well as inverse modeling, linear mixture modeling, and vegetation index techniques.

Asner, Gregory P.↗

Determining Reactor Fuel Type from Continuous Antineutrino Monitoring

In this work, we investigate the ability of an antineutrino detector to determine the fuel type of a reactor. A hypothetical 5-ton antineutrino detector is placed 25 m from the core and measures the spectral shape and rate of antineutrinos emitted by fission fragments in the core for a number of 90-d periods. Our results indicate that four major fuel types can be differentiated from the variation of fission fractions over the irradiation time with a true positive probability of detection at approximately 95%. In addition, we demonstrate that antineutrinos can identify the burnup at which weapons-grade mixed-oxide (MOX) fuel would be reduced to reactor-grade MOX, on average, providing assurance that plutonium-disposition goals are met. We also investigate removal scenarios where plutonium is purposefully diverted from a mixture of MOX and low-enriched uranium fuel. Lastly, we discuss how our analysis is impacted by a spectral distortion around 6 MeV observed in the antineutrino spectrum measured from commercial power reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A spectral multi-domain technique for analysis of chemically reacting flows

A technique is presented which models the chemical kinetics and flow kinematics of a nonionized air mixture passing through a fully resolved shock wave, thus alleviating the need for artificial viscosity. The quasi-one-dimensional Navier-Stokes equations and the species conversation equation are the governing equations. The validity of the multidomain Navier-Stokes algorithm is demonstrated via comparison with experiment.

Macaraeg, Michele G.↗

Analysis of steranes and triterpanes in geolipid extracts by automatic classification of mass spectra

A computer method is described for the automatic classification of triterpanes and steranes into gross structural type from their mass spectral characteristics. The method has been applied to the spectra obtained by gas-chromatographic/mass-spectroscopic analysis of two mixtures of standards and of hydrocarbon fractions isolated from Green River and Messel oil shales. Almost all of the steranes and triterpanes identified previously in both shales were classified, in addition to a number of new components. The results indicate that classification of such alkanes is possible with a laboratory computer system. The method has application to diagenesis and maturation studies as well as to oil/oil and oil/source rock correlations in which rapid screening of large numbers of samples is required.

Wardroper, A. M. K.↗

A tool for manual endmember selection and spectral unmixing

Sampling a continuous radiance spectrum in many narrow contiguous spectral bands results in a high covariance between the bands. Hence, the true dimensionality of imaging spectrometer data is not determined by the number of spectral bands, but by the number of spectrally unique signatures whose mixtures reproduce the spectral variance observed in an image. Methods to unmix high dimensional multispectral data use principal components analysis to reduce the dimensionality. The variance of the spectral data is modeled as a linear combination of a finite set of endmembers in the space of the eigen-vectors that account for most of the variance. The number and characteristics of these endmembers are determined not only by the number and characteristics of the spectrally unique materials on the surface but also by processes (e.g., illumination, atmospheric scattering and absorption) affecting the signal received by the sensor. Selection of endmember spectra has typically been from a library. However, since most libraries are incomplete and do not account for the processes mentioned above, we have devised a computer display that allows researchers to explore interactively the eigenvector space of a representative and mean-corrected subset of the image data in search of extreme spectra to designate as endmembers. This display, which is based on parallel coordinates, is unique in the area of multidimensional visualization in that it includes not only a passive view of higher dimensional data but also the capability to interact and move geometrical objects in higher dimensional spaces.

Bateson, C. Ann↗

Chemical composition of Luna 16 lunar regolith

Data on the chemical composition of regolith returned by the Luna 16 automatic station and two fragments of basalts from the lower layer of the core are presented. Spark mass spectrometric, primary X-ray spectral, emission spectral, and atomic absorption methods were used in the analysis. The regolith of mare provinces were shown to be a mixture of material of various origins. The source of the material of the mare regolith was principally basalts of the corresponding lunar lava maria. The regolith is genetically related to it. This follows from a comparison of the chemical composition, mineralogical, and petrochemical features of the basesalts and the regolith from the Sea of Fertility, Sea of Tranquillity, and Ocean of Storms, respectively.

Vinogradov, A. P.↗

X-ray Spectral Analysis for Void Fraction Measurement

X-ray attenuation technique has been widely used in two-phase flow measurement. In general, an x-ray system measures the overall attenuation of the two-phase mixture existing between an x-ray source and a detector. One can obtain the void fraction from the intensity of the attenuated x-ray beam and known attenuation coefficients of each phase. Fig. 1 shows a schematic of the line detector system developed at Virginia Tech, and the reconstructed image of a sample slug bubble. The system is capable of obtaining high-resolution (100 {mu}m or less) x-ray images of two-phase flow at a frame rate exceeding 1000 Hz. Note that the intensity of the image can be converted into the line-averaged void fraction data measured by each detector pixel. Typical x-ray systems do not resolve the energy spectrum. Instead, they only measure the total energy deposited in the detector during the exposure period. However, the x-ray source generated from x-ray tubes present polychromatic characteristics. The attenuation coefficient and detector efficiency strongly depend on the energy of x-ray photons. In relation to this, this paper presents the spectral characteristics of a typical x-ray system used for void fraction measurement in two-phase flows. The photon-energy-dependent efficiency of the detector is determined by a calibration test. (authors)

42 ENGINEERING↗