Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sorbent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Performance of copper chloride-impregnated sorbents on mercury vapor control in an entrained-flow reactor system

An entrained-flow system has been designed and constructed to simulate in-flight mercury (Hg) capture by sorbent injection in ducts of coal-fired utility plants. The test conditions of 1.2-sec residence time, 140{degree}C gas temperature, 6.7 m/sec (22 ft/sec) gas velocity, and 0-0.24 g/m{sup 3} (0-15 lbs of sorbent per 1 million actual cubic feet of flue gas sorbent injection rates were chosen to simulate conditions in the ducts. Four kinds of sorbents were used in this study. Darco Hg-LH (lignite-based) served as a benchmark sorbent with which Hg control capability of other sorbents could be compared. Also, Darco-FGD (lignite-based) was used as a representative raw activated carbon sorbent. Two different copper chloride-impregnated sorbents were developed in the laboratory and tested in the entrained-flow system to examine the possibility of using these sorbents at coal-fired power plants. The test results showed that one of the copper chloride sorbents has remarkable elemental mercury (Hg{sup 0}) oxidation capability, and the other sorbent demonstrated a better performance in Hg removal than Darco Hg-LH. 13 refs., 4 figs., 3 tabs.

01 COAL, LIGNITE, AND PEAT↗

Dual-Bed Radioiodine Capture from Complex Gas Streams with Zeolites: Regeneration and Reuse of Primary Sorbent Beds for Sustainable Waste Management

Dual-sorbent systems are proposed for radioiodine management with a regenerated primary bed for multiple cycles of use in complex conditions and a secondary bed for disposal with higher waste loadings. Sorbent approaches for the effective capture of gaseous radioiodine (isotopes 129 I and 131 I) produced from a range of nuclear processes have been studied for over half a century. (1−5) Whether or not a sorbent (e.g., molecular sieve) is required to physically screen/trap or chemically bind a radionuclide of interest through chemisorption, the complexity of the gas stream has a large impact on the performance (e.g., loading capacity, selectivity) and active life of a sorbent bed. (3) Silver mordenite (AgZ), the U.S. Department of Energy baseline sorbent for radioiodine capture from nuclear processes, performs well within acidic conditions and at elevated temperatures (6) and can be consolidated into a chemically durable waste form for long-term disposal. (7,8) However, new sorbents are being sought because optimal capture performance of AgZ significantly decreases in dynamic oxidizing environments with competing species, and it is expensive and it contains Ag (a toxic metal). (9) Until a new sorbent is found to replace AgZ, the regeneration and reuse of AgZ is an attractive alternative to a single-use primary sorbent bed. In this regard, a primary sorbent could be designed for enhanced capture in complex gas streams and the ability to be regenerated for reuse. Here, a secondary sorbent could then be tailored for maximum iodine loading in the gas stream and chemical durability within a disposal facility.

chemisorption↗

Experiment and modeling of CO{sub 2} capture from flue gases at high temperature in a fluidized bed reactor with Ca-based sorbents

The cyclic CO{sub 2} capture and CaCO{sub 3} regeneration characteristics in a small fluidized bed reactor were experimentally investigated with limestone and dolomite sorbents. Kinetic rate constants for carbonation and calcination were determined using thermogravimetric analysis (TGA) data. Mathematical models developed to model the Ca-based sorbent multiple cycles of CO{sub 2} capture and calcination in the bubbling fluidized bed reactor agreed with the experimental data. The experimental and simulated results showed that the CO{sub 2} in flue gases could be absorbed efficiently by limestone and dolomite. The time for high-efficiency CO{sub 2} capture decreased with an increasing number of cycles because of the loss of sorbent activity, and the final CO{sub 2} capture efficiency remained nearly constant as the sorbent reached its final residual capture capacity. In a continuous carbonation and calcination system, corresponding to the sorbent activity loss, the carbonation kinetic rates of sorbent undergoing various cycles are different, and the carbonation kinetic rates of sorbent circulating N times in the carbonation/calcination cycles are also different because of the different residence time of sorbent in the carbonator. Therefore, the average carbonation rate was given based on the mass balance and exit age distribution for sorbent in the carbonator. The CO{sub 2} capture characteristics in a continuous carbonation/calcination system were predicted, taking into consideration the mass balance, sorbent circulation rate, sorbent activity loss, and average carbonation kinetic rate, to give useful information for the reactor design and operation of multiple carbonation/calcination reaction cycles. 27 refs., 15 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Characteristics and reactivity of rapidly hydrated sorbent for semidry flue gas desulfurization

The semidry flue gas desulfurization (FGD) process has many advantages over the wet FGD process for moving sulfur dioxide emissions from pulverized coal-fired power plants. Semidry FGD with a rapidly hydrated sorbent was studied in a pilot-scale circulating fluidized bed (CFB) experimental facility. The sorbent was made from lumps of lime and coal fly ash. The desulfurization efficiency was measured for various operating parameters, including the sorbent recirculation rate and the water spray method. The experimental results show that the desulfurization efficiencies of the rapidly hydrated sorbent were 1.5-3.0 times higher than a commonly used industrial sorbent for calcium to sulfur molar ratios from 1.2 to 3.0, mainly due to the higher specific surface area and pore volume. The Ca(OH){sub 2} content in the cyclone separator ash was about 2.9% for the rapidly hydrated sorbent and was about 0.1% for the commonly used industrial sorbent, due to the different adhesion between the fine Ca(OH){sub 2} particles and the fly ash particles, and the low cyclone separation efficiency for the fine Ca(OH){sub 2} particles that fell off the sorbent particles. Therefore the actual recirculation rates of the active sorbent with Ca(OH){sub 2} particles were higher for the rapidly hydrated sorbent, which also contributed to the higher desulfurization efficiency. The high fly ash content in the rapidly hydrated sorbent resulted in good operating stability. The desulfurization efficiency with upstream water spray was 10-15% higher than that with downstream water spray. 20 refs., 7 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Performance of a novel synthetic Ca-based solid sorbent suitable for desulfurizing flue gases in a fluidized bed

The extent and mechanism of sulfation and carbonation of limestone, dolomite, and chalk, were compared with a novel, synthetic sorbent (85 wt % CaO and 15 wt % Ca{sub 12}A{sub l14}O{sub 33}), by means of experiments undertaken in a small, electrically heated fluidized bed. The sorbent particles were used either (I) untreated, sieved to two particle sizes and reacted with two different concentrations of SO{sub 2}, or (ii) after being cycled 20 times between carbonation, in 15 vol % CO{sub 2} in N2, and calcination, in pure N2, at 750 degrees C. The uptake of untreated limestone and dolomite was generally low (<0.2 g(SO{sub 2})/g(sorbent)), confirming previous results, However, the untreated chalk and the synthetic sorbent were found to be substantially more reactive with SO{sub 2}, and their final uptake was significantly higher (>0.5 g(SO{sub 2})/g(sorbent)) and essentially independent of the particle size. Here, comparisons are made on the basis of the sorbents in the calcined state. The capacities for the uptake of SO{sub 2}, on a basis of unit mass of calcined sorbent, were comparable for the chalk and the synthetic sorbent. However, previous work has demonstrated the ability of the synthetic sorbent to retain its capacity for CO{sub 2} over many cycles of carbonation and calcination: much more so than natural sorbents such as chalk and limestone. Accordingly, the advantage of the synthetic sorbent is that it could be used to remove CO{sub 2} from flue gases and, at the end of its life, to remove SO{sub 2} on a once-through basis.

01 COAL, LIGNITE, AND PEAT↗

SO 2 -Resistant Immobilized Amine Sorbents for CO 2 Capture

The solid amine sorbent for CO 2 capture process has advantages of simplicity and low operating cost compared to the MEA (monoethanolamine) process. Solid amine sorbents reported so far suffered from either low CO 2 capture capacity or low stability in the flue gas environment. This project is aimed at developing a SO 2 -resistant solid amine sorbent for capturing CO 2 from coal–fired power plants with SCR/FGD which emits SO 2 ranging from 15 to 30 ppm and NO ranging from 5 to 10 ppm. The amine sorbent we developed in a previous project degraded rapidly with 65% decrease in the initial capture capacity in presence of 1% SO 2 . This amine sorbent was further modified by coating with polyethyleneglycol (PEG) to increase the SO 2 -resistance. Polyethylene glycol (PEG) was found to decrease the SO 2 -amine interaction, resulting in the decrease in the maximum SO desorption temperature (Tmax ) of amine sorbent. The PEG-coated amine sorbent exhibited higher stability with only 40% decrease in the initial capture capacity compared to un-coated amine sorbents. The cost of the solid amine sorbent developed in this project is estimated to be less than $7.00/lb; the sorbent exhibited CO 2 capture capacity more than 2.3 mmol/g. The results of this study provided the scientific basis for further development of SO 2 -resistant sorbents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating Autoxidation Radical Scavengers and Additives to Enhance Aminopolymer Sorbent Stability

Solid amine sorbents have shown promise in the removal of ultradilute CO 2 from the atmosphere. Despite being a promising candidate material type for this application, these sorbents are prone to degradation during long-term exposure to environmental components such as CO 2 , O 2 , and H 2 O, with amine oxidation being a particularly challenging problem. In this study, we investigate the potency of different radical scavengers and additives in mitigating the degradation of a model poly- (ethylenimine) (PEI)/Al 2 O 3 sorbent under direct air capture (DAC)-relevant conditions. The results reveal that a 4,4′-bis(α,α- dimethylbenzyl)diphenylamine (BDDPA)-incorporated PEI/Al 2 O 3 sorbent showed the most resistance toward oxidative degradation at varying exposure times and BDDPA loadings under CO 2 -free air (21% O 2 /balance N 2 ) at 120 °C. Interestingly, under humid (∼43% relative humidity (RH) at 26 °C) and dry 0.04% CO 2 -air, the BDDPA/PEI/Al 2 O 3 sorbent showed enhanced sorbent stability both at 70 and 120 °C after 4.5 h of exposure. Under humid CO 2 -free air, at 120 °C, the antioxidant performance slightly declined (in comparison to the dry CO 2 -free air condition) but displayed a much higher stability than the pristine sorbent. Overall, the ability of BDDPA to inhibit sorbent degradation under dry and humid, CO 2 -free and CO 2 -containing (0.04%) air at intermediate (70 °C) and elevated (120 °C) temperatures is promising in prolonging sorbent stability and underscores the importance of performing accelerated oxidation studies in the presence of all species that are expected to be present in DAC processes to identify suitable stabilization treatments for sorbent materials.

36 MATERIALS SCIENCE↗

Sorbent Based Post-Combustion CO 2 Slipstream Testing

TDA Research, Inc. has developed a low-cost sorbent (alkalized alumina) based technology for post-combustion CO 2 capture. The sorbent runs in an isothermal process for adsorption and regeneration. Neither temperature swing nor pressure swing is needed. TDA designed a system which operated 10 fixed beds to simulate a moving bed process. The flow pattern was optimized to minimize the steam usage for regeneration. An excellent sorbent (Batch 1) was also developed with collaboration with our partner. The sorbent degraded after long term operation. We developed a reprocessing procedure, which can be conducted in situ, to restore the sorbent capture capacity as the fresh sorbent after running for about 1250 hours. The reprocessing extended the sorbent longevity significantly. TDA designed a pilot unit (40’ x 32’ x 11.5’), processing flue gas equivalent to 0.5 MW of power generation. It had 10 beds and each bed could hold 1.75 m 3 of sorbent. We worked with Springs Fabrication, Inc. to complete the construction of the pilot unit. It was then shipped and installed at NCCC. The pilot unit was kept running in 24-hour mode when the flue gas and steam were available. It could run automatically without operator on site. Parametric and long-term (2 months) tests were carried out successfully. The results showed that TDA’s process can achieve 90% capture and 95% CO 2 purity for both coal and NG flue gases. For coal flue gas, the system reached performance target when processing up to 0.62 MW flue gas, 24% higher than the design capacity. Thus, capital cost could be saved on the reactors and sorbent. The strip air flow was designed to be 0.25 of that of the flue gas. The test data showed the strip/flue ratio can be reduced to as little as 0.18, which saves the power consumption for the strip air blower. The pressure drop was found to be lower than what the empirical equation calculated. The sorbent still had 91.7% of original capacity after 3-month test. With the data from the pilot test, we updated the TEA. For a 550-MW e supercritical coal fired power plant with CO 2 capture, the capture cost for TDA’s process is $34.9/tonne CO 2 captured, which meets DOE’s goal of $40/tonne and is 17.1% less than the DOE baseline Case 12. Therefore, TDA’s process has a good potential for commercialization.

01 COAL, LIGNITE, AND PEAT↗

Parametric study on the CO{sub 2} capture capacity of CaO-based sorbents in looping cycles

An experimental parametric study on the CO{sub 2} capture activity of four limestone-derived CaO-based sorbents was performed. Experiments were done in a thermogravimetric analyzer (TGA) at temperatures ranging from 650 to 850{sup o}C. Three particle-size fractions of Kelly Rock limestone and powders obtained by their grinding were also tested, while the influence of carbonation and calcination durations was examined at 750 and 850{sup o}C. The results indicated that increasing the calcination/carbonation temperature had a negative influence on the sorbent activity, while the influence of particle size was small, although larger particles have higher activity. This was unexpected, but it can be explained by the higher content of impurities in the smaller particles. Grinding enhances sorbent activity, and this appears to be more than simply due to increased external surface area of the sorbent particles in the powdered samples. Prolonged carbonation time has a negative effect on the sorbent performance. The formation and decomposition of CaCO{sub 3} as well as its presence on the sorbent surface at higher temperatures appear to be key factors in the loss of surface area (i.e., decrease in sorbent activity). However, it is shown that the prolonged exposure to calcination conditions employed in this work (inert atmosphere) has a slightly beneficial effect on sorbent behavior as a function of the number of calcination/carbonation cycles. Experiments with larger sample masses typically resulted in better conversions. Analysis of scanning electron microscope (SEM) images of spent sorbent particles obtained from different reactor types indicated that thermal stresses are the main cause for sorbent particle fracture and attrition. 36 refs., 10 figs.

01 COAL, LIGNITE, AND PEAT↗

Study on the stability of sorbents removing H{sub 2}S from hot coal gas

Mixed metal oxide containing iron with the high-sulfur capacity and reactivity is considered as one of the most favorable sorbents for desulfurization in hot gas. The stability and life of iron-based sorbents are the main challenges for the hot gas cleanup techniques. Not only the effect of gas atmosphere but also the effect of ZnO and MgO on the stability of iron-based sorbent was studied in this work. The mechanism and factors influencing sorbent stability are discussed. The results showed that the coexistence of CO and H{sub 2} result in the instability of the zinc-iron-based sorbents. The reaction of carbon deposit is the crucial step affecting the stability of sorbent for hot gas desulfurization. ZnO in the sorbent is adverse to the physical stability of the iron-based sorbents. MgO in the sorbent hardly affects the physical stability of the iron-based sorbents but improves the capacity of removing the hydrogen sulfide from hot coal gas at 773 K. 12 refs., 8 figs., 5 tabs.

01 COAL, LIGNITE, AND PEAT↗

SO{sub 2} Retention by CaO-Based Sorbent Spent in CO{sub 2} Looping Cycles

CaO-based looping cycles are promising processes for CO{sub 2} Capture from both syngas and flue gas. The technology is based on cyclical carbonation of CaO and regeneration of CaCO{sub 3} in a dual fluidized-bed reactor to produce a pure CO{sub 2} stream suitable for sequestration. Use of spent sorbent from CO{sub 2} looping cycles for SO{sub 2} capture is investigated. Three limestones were investigated: Kelly Rock (Canada), La Blanca (Spain), and Katowice (Poland, Upper Silesia). Carbonation/calcination cycles were performed in a tube furnace with both the original limestones and samples thermally pretreated for different times (i.e., sintered). The spent sorbent samples were sulfated in a thermogravimetric analyzer (TGA). The changes in the resulting sorbent pore structure were then investigated using mercury porosimetry. It has been shown that the sulfation rates of both thermally pretreated and spent sorbent samples are lower in comparison with those of the original samples. However, final conversions of both spent and pretreated sorbents after longer sulfation time were comparable or higher than those observed for the original sorbents under comparable conditions. Maximum sulfation levels strongly depend on sorbent porosity and pore surface area. The results showed that spent sorbent samples from CO{sub 2} looping cycles can be used as sorbents for SO{sub 2} retention in cases where significant porosity loss does not occur during CO{sub 2} reaction cycles. In the case of spent Kelly Rock and Katowice samples, sorbent particles are practically uniformly sulfated, achieving final conversions that are determined by the total pore volume available for the bulky CaSO{sub 4} product.

01 COAL, LIGNITE, AND PEAT↗

Pilot Testing of a Highly Efficient Pre-combustion Sorbent-based Carbon Capture System

TDA developed and demonstrated a highly efficient pre-combustion carbon capture system. The overall objective of this work was to develop a new sorbent-based pre-combustion carbon capture technology for Integrated Gasification Combined Cycle (IGCC) power plants. In this project our goal was to demonstrate the techno-economic viability of the new technology by 1) demonstrating it in large-scale slipstream tests, and 2) carrying out a high fidelity engineering and cost analysis. TDA’s process used an advanced physical adsorbent that selectively removes CO 2 from coal-derived synthesis gas above the dew point of the gas at temperatures as high as 300°C. The sorbent consists of a mesoporous carbon whose surface was grafted with functional groups that remove CO 2 via a well-known acid-base interaction. As documented in bench-scale experiments and field tests with actual coal gas, the sorbent achieved a very high capacity for CO 2 at temperatures as high as 300°C. The sorbent bound CO 2 more strongly than common physical adsorbents, providing the chemical potential needed for the high temperature operation. However, because CO 2 does not form a true covalent bond with the surface sites (as is the case with chemical absorbents), the sorbent regeneration could be carried out with only a very small energy input. The heat input to regenerate our sorbent was only 4.9 kcal per mol of CO 2 , which is much lower than that for chemical absorbents (e.g., 29.9 kcal/mol CO 2 for sodium carbonate) and was similar to the requirements of physical solvents (e.g., 4 kcal/mol CO 2 for Selexol TM ). Because the sorbent operates above the dew point of the synthesis gas (unlike the Selexol TM process), a higher power cycle efficiency can be achieved. With previous DOE/NETL funding (Contract No. DE-FE-0000469), we demonstrated the techno-economic viability of the technology in bench-scale tests and slipstream demonstrations at the National Carbon Capture Center (NCCC), Wilsonville, Alabama and Wabash River IGCC plant in Terra Haute, Indiana. We demonstrated a stable working CO 2 capacity for over 11,650 cycles with simulated synthesis gas. We also evaluated its performance with actual synthesis gas in two test campaigns at the Wabash River IGCC Plant, Terre Haute, IN and the National Carbon Capture Center (NCCC), Wilsonville, AL. The slipstream tests clearly showed that the actual coal gas constituents and potential contaminants (e.g. trace metals, halides, tars) had no effect on the sorbent’s ability to remove CO 2 (the same sorbent beds were used in both field tests with no sign of deactivation for 2,000 cycles with over 26,750 SCF of gas treated). As expected, due to the high temperature CO 2 removal capability and low energy needed to regenerate the sorbent, the power cycle efficiency with our process was greater than 34% on a higher heating value (HHV) basis; in comparison, the same IGCC plant equipped with the Selexol TM solvent for carbon capture can only achieve 31.4% HHV efficiency. The capital cost for an IGCC system with TDA’s process is estimated as $2,417/kW e , which is 12% lower than that of the IGCC/ Selexol TM process. The levelized cost for electricity including the transport, storage and monitoring (TS&M) cost for CO 2 was calculated as $\$ $92.9/MWh (lowest reported to our knowledge), which is much better than the $105.2/MWh estimated for the IGCC/ Selexol TM process. In this project (DE-FE0013105), TDA Research, in collaboration with our partners Gas Technology Institute (GTI), Illinois Clean Coal Institute (ICCI), University of California, Irvine (UCI), University of Alberta (UOA), Siemens, NCCC and Sinopec advanced the technical maturity of the technology; scaling it up by a factor of 100. We optimized the reactor design using computational fluid dynamics (CFD); using adsorption modeling we improved the pressure swing adsorption (PSA) cycle sequence. We carried out two field test campaigns with a fully-equipped 0.1 MW e prototype unit (for a total of 844 hours) using actual synthesis gas to prove the viability of the new technology. A successful 30 day (707 hrs) evaluation was completed at NCCC under air blown gasification conditions. We demonstrated 97.3% carbon capture at 1,500 SLPM, 93% carbon capture at 1,800 SLPM, and 90% carbon capture at 2,100 SLPM in the NCCC tests. We also demonstrated the system for 137 hours at a Sinopec petrochemical plant under oxygen blown gasification, demonstrating 86% carbon capture at 2,660 SLPM. In collaboration with University of California, Irvine (UCI), we completed a techno-economic analysis (TEA) for TDA’s warm gas cleanup technology integrated to IGCC power plant. The net plant efficiencies (on a coal HHV basis) for the warm gas cleanup cases were estimated to be 34.0% for E-GasTM gasifier, 34.4% for GE gasifier, 33.4 for the Shell gasifier and 34.2 for the TRIG TM gasifier (Cases 2, 4, 6 and 8 in this study) with a catalytic combustor for CO 2 purification, which are significantly higher than those for the Cold Gas Case, or an increase of as much as 12% in the heat rate for Case 2, 6% for Case 4, 9% for Case 6, and 9% for Case 8. The 1st year cost of electricity with the transport, storage and monitoring (TS&M) costs for the CO 2 included was $\$ $129.2/MWh for the E-GasTM gasifier Warm Gas Cleanup Case, $\$ $131.9/MWh for the GE gasifier Warm Gas Cleanup Case, $\$ $146.8/MWh for the Shell Gasifier Warm Gas Cleanup Case, and $\$ $129.9/MWh for the TRIG TM gasifier Warm Gas Cleanup Case. For comparison, the costs for the baseline Cold Gas CO 2 removal with Selexol for the different gasifiers were: $\$ $146.6/MWh for the E-Gas TM gasifier, $\$ $142.2/MWh for the GE gasifier, $\$ $159.0/MWh for the Shell gasifier and $\$ $144.3/MWh for the TRIG TM gasifier. In summary, the costs for our system were 7 to 12% lower than the corresponding Cold Gas Cleanup cases. The results of this techno-economic analysis suggested that TDA’s high temperature PSA-based Warm Gas Clean-up Technology can make a substantial improvement in the IGCC plant thermal performance for achieving near zero CO 2 emissions for E-Gas TM , GE, Shell and TRIG TM gasifier based IGCC power plants. The capital expenses were estimated to be lower than that of Selexol’s™. Taken together, the higher net plant efficiency and lower capital and operating costs resulted in substantial reduction in the cost of carbon capture for the IGCC plant equipped with TDA’s high temperature PSA-based carbon capture system. Finally, in collaboration with Gas Technology Institute (GTI) we completed the environmental health and safety assessment for TDA’s warm gas carbon capture technology.

01 COAL, LIGNITE, AND PEAT↗

Effect of Storage Conditions on Efficacy of Poly(ethylenimine)-Alumina CO 2 Sorbents

Solid amine sorbents are one of the primary components of DAC technologies that allow for the removal of ultradilute CO 2 from the atmosphere. A main drawback in the implementation of solid amine sorbents in industrial-scale DAC applications is their instability under certain operational or storage conditions over an extended period. In this work, the effect of storage temperature and gas composition in the storage headspace on the long-term stability of a poly(ethylenimine)-alumina (PEI/γ-Al 2 O 3 ) sorbent is explored. PEI/γ-Al 2 O 3 sorbents with 70 and 100% pore filling are aged under varying gases (N 2 , O 2 , Ar, 0.04% CO 2 −N 2 , CO 2 , and ambient air) in an oven (40 °C), at common ambient indoor temperature conditions (23 °C), or in a freezer (−4 °C). The CO 2 sorption capacity, as measured by thermogravimetric analysis (TGA), along with FTIR spectra of the fresh and aged sorbents, reveal that at 23 and −4 °C, storage under ambient air or inert gas (Ar) provides reasonable long-term stability, with <13% degradation over 12 and 5 months of storage. Interestingly, with storage at 40 °C, similar levels of deactivation were observed under pure O 2 and N 2 after 4 months of storage, which suggests that nonoxidative thermal reactions can occur under prolonged storage conditions under N 2 . In contrast, with storage under CO 2 , sorbent degradation is substantially suppressed compared to storage under N 2 , ambient air, O 2 , or Ar, yielding sorbents with no observable loss in capacity after 2 months, compared to a 66, 63, and 62% loss under N 2 , ambient air, and N 2 in the same period at 40 °C, respectively. Overall, these findings provide guidance for practical amine sorbent storage in academic or industrial settings where amine sorbents are used for carbon capture.

Atmospheric chemistry↗

Sorbent Scoping Studies

The Los Alamos National Laboratory–Carlsbad Operations (LANL-CO) office was tasked by the DOE CBFO, Office of the Manager to perform a review of the acceptable knowledge (AK) to identify the oxidizers and sorbents in transuranic (TRU) waste streams, to conduct scoping studies on the oxidizers and sorbents identified in AK review to inform the Quality Level 1 (QL1) testing, and to conduct a series of QL1 tests to provide the scientific data to support a basis of knowledge document for determining the criteria for (1) accepting waste at the Waste Isolation Pilot Plant (WIPP) without treatment, (2) determining waste that will require treatment, and (3) if treatment is required, how the treatment must be performed. The purpose of this report is to present the results of the AK review of sorbents present in active waste streams, provide a technical analysis of the sorbent list, report the results of the scoping studies for the fastest-burning organic sorbent, and provide the list of organic and inorganic sorbents to be used in the development of a Test Plan for Preparation and Testing of Sorbents Mixed with Oxidizer found in Transuranic Waste (DWT-TP-001). The companion report, DWT-RPT-001, Oxidizer Scoping Studies, has similar information for oxidizers identified during the AK review of TRU waste streams. The results of the oxidizer and sorbent scoping studies will be used to inform the QL1 test plan. The QL1 test results will support the development of a basis of knowledge document that will evaluate oxidizing chemicals and sorbents in TRU waste and provide guidance for treatment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Bench-Scale Development of a Novel Direct Air Capture Technology Using High-Capacity Structured Sorbents

The work performed under this project has resulted into development of a DAC technology utilizing a structured sorbent to capture CO 2 from ambient air with a key innovation of direct Joule heating of the sorbent for CO 2 desorption. A working SMA, fully integrated with an electrically resistive heating layer, high surface area support, and high CO 2 capacity sorbent coated onto a commercial ceramic monolithic substrate, was successfully developed and demonstrated over >200 adsorption-desorption cycles in a high-fidelity bench test unit directly using ambient air. A cordierite-based monolith was selected as a substrate owing to its high surface area, low bulk density, low heat capacity, and commercial availability. Reaction kinetics study conducted during this project led to development of a promoter for the base Na 2 CO 3 sorbent that could be incorporated into the sorbent to enhance to achieve higher CO 2 adsorption/desorption rates, greater working capacity, and reduced regeneration temperature. An accelerated aging study was conducted in a TGA to determine sorbent stability and no degradation in the sorbent performance was observed even after 250 adsorption-desorption cycles. An electrically resistive heating layer was developed with tunable electrical properties. The heating layer was coated onto the selected cordierite substrate. Aging studies performed showed the electrical properties and heating performance was stable after 500 heating and cooling cycles. The collective findings on the selected cordierite substrate, robust heating layer, promoter and sorbent selection were used to synthesize a full, 6”x6” SMA for bench-scale testing. The bench-scale DAC system was constructed to test full size SMAs using real ambient air for adsorption and joule heating for regeneration. After completing shakedown and commissioning of the 1 kg/day of CO 2 capacity DAC bench unit, an extended operation was performed to complete over 230 cycles with the full size SMA. This testing showed no observable degradation in sorbent performance. A detailed process model, TEA and LCA were developed for a conceptual 100,000 TPY CO 2 removal DAC facility. The LCA results show the net CO 2 e emissions from the DAC system are highly dependent on the electricity source. All other factors, including SMA manufacturing, materials for facility enclosure, etc., are minor cost contributors compared to the energy consumption required for CO 2 removal. With the successful development and validation of the SMA for the sustained performance for CO 2 removal from ambient air with joule heated regeneration in this project, a fully integrated 1 TPY bench-scale DAC system is currently in development with the support of DOE/FECM (DE-FE0032243). The project objective is to demonstrate the engineering design of the DAC system to produce a continuous, high purity CO 2 stream from ambient air. This project will address and validate key engineering features of the DAC system including the gas sealing mechanism and panels, enclosure and air contactor design, and automation sequence to achieve continuous CO 2 production.

42 ENGINEERING↗

Mercury removal from flue gases by novel regenerable magnetic nanocomposite sorbents

Magnetic zeolite composites with supported silver nanoparticles are a new class of multifunctional materials with potential applications as recyclable catalysts, disinfectants, and sorbents. This study evaluated the suitability of the magnetic composites as sorbents for the removal of elemental mercury vapor from flue gases of coal-fired power plants. The sorbents were found to completely capture mercury at temperatures up to 200{sup o}C, and the mercury capacity of the sorbents was found to be affected by the state, content, and size of the silver particles in the composite. Cumulative or extended thermal treatments at 400{sup o}C were found to improve the mercury capture capacity, allowing the sorbent to be regenerated and recycled multiple times without performance degradation. The magnetic sorbent was readily separated from fly ash by magnetic separation, leaving the fly ash essentially free of sorbent contamination. In initial in-plant tests, the sorbents were able to capture mercury from the flue gases of an operational, full-scale, coal-fired power plant. The combination of mercury capacity, ease of separation and regeneration, and recyclability makes these multifunctional magnetic composites excellent candidate sorbents for the control of mercury emissions from coal-fired power plants. 35 refs., 5 figs., 2 tabs.

01 COAL, LIGNITE, AND PEAT↗

Sodium-based dry regenerable sorbent for carbon dioxide capture from power plant flue gas

Dry regenerable sorbent technology is one of the emerging technologies as a cost-effective and energy-efficient technology for CO{sub 2} capture from flue gas. Six sodium-based dry regenerable sorbents were prepared by spray-drying techniques. Their physical properties and reactivities were tested to evaluate their applicability to a fluidized-bed or fast transport-bed CO{sub 2} capture process. Each sorbents contained 20-50 wt% of Na{sub 2}CO{sub 3} or NaHCO{sub 3}. All sorbents except for Sorb NX30 were insufficient with either attrition resistance or reactivity, or both properties. Sorb NX30 sorbent satisfied most of the physical requirements for a commercial fluidized-bed reactor process along with good chemical reactivity. Sorb NX30 sorbent had a spherical shape, an average size of 89 {mu}m, a size distribution of 38-250 {mu}m, and a bulk density of approximately 0.87 g/mL. The attrition index (AI) of Sorb NX30 reached below 5% compared to about 20% for commercial fluidized catalytic cracking (FCC) catalysts. CO{sub 2} sorption capacity of Sorb NX30 was approximately 10 wt% (>80% sorbent utilization) in the simulated flue gas condition compared with 6 of 30 wt% MEA solution (33% sorbent utilization). All sorbents showed almost-complete regeneration at temperatures less than 120{sup o}C.

01 COAL, LIGNITE, AND PEAT↗

High-Performance, Superparamagnetic, Nanoparticle-Based Heavy Metal Sorbents for Removal of Contaminants from Natural Waters

We describe the synthesis and characterization of superparamagnetic iron oxide nanoparticle based heavy metal sorbents with various surface chemistries that demonstrate an excellent affinity for the separation of heavy metals in contaminated water systems (i.e. spiked Columbia river water). The magnetic nanoparticle sorbents are prepared from an easy to synthesize iron oxide precursor, followed by a simple, one-step ligand exchange technique to introduce the organic surface functionality of interest chosen to target either specific or broader classes of heavy metals. Functionalized superparamagnetic nanoparticles are excellent sorbent materials for the extraction of heavy metal contaminants from environmental and clinical samples since they are easily removed from the media once bound to the contaminant by simply applying a magnetic field. These engineered magnetic nanoparticle sorbents have an inherently high active surface area (often > 100 m2/g), allowing for increased binding capacity. To demonstrate the potential sorbent performance of each of the surface modified magnetic nanoparticles, river water was spiked with Hg, Pb, Cd, Ag, Co, Cu, and Tl and exposed to low concentrations of the functionalized nanoparticles. The samples were analyzed to determine the metal content before and after exposure to the magnetic nanoparticle sorbents. In almost all cases reported here the nanoparticles were found to be superior to commercially available sorbents binding a wide range of different heavy metals with extremely high affinity. Detailed characterization of the functionalized magnetic nanoparticle sorbents including FT-IR, BET surface analysis, TGA, XPS and VSM as well as the heavy metal removal experiments are presented.