Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Soot”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Single-Particle Soot Photometer (SP2) Black Carbon Number and Mass Concentrations

The single-particle soot photometer (SP2) records particle-by-particle measurements of the intensity of both the scattering signature and incandescence signature of particles that enter its laser beam. These intensities are then used to calculate refractory black carbon (rBC) masses and particle diameters. In previous U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility field campaigns, the SP2 data was difficult to process because the manufacturer-supplied code was not scalable to distributed machines, making it unusable for the large amounts of data output by the SP2. This prohibited the SP2 from becoming an operational instrument for ARM. Therefore, PySP2 was developed to solve this issue and enable SP2 to be an operational instrument for ARM. This technical document summarizes the test data sets from the ARM North Slope of Alaska (NSA) site and the Multidisciplinary Drifting Observatory for the Study of Arctic Climate (MOSAiC) field campaign that were used to develop and test PySP2.

54 ENVIRONMENTAL SCIENCES↗

A Reaction Mechanism for Carbon Soot in Post-Detonation Flows

This report documents the generation of a mechanism to predict the inclusion of carbon soot particles in a high explosive flow. The mechanism includes gasification and oxidation reactions, formation, sublimation, radiation, and agglomeration. Each part of the mechanism is derived from properties in the literature. The influence of each part of the mechanism is explored using simple, example simulations consisting of a 12 mm diameter 2,4,6-Trinitrotoluene charge detonated in ambient air. The mechanism has not been quantitatively compared to experiments. Additional efforts will be required to tune and validate it, which will require continued advancements in experimental diagnostics and simulation techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Predicting soot and radiation in pool fires using flamelet methods

This work provides an overview of the ongoing research to better estimate radiation and soot in large-scale pool fires. The core focus of this presentation is on improvements to models for novel physics at larger scales.

Meehan, Michael Alexander [Sandia National Laborat↗

Demonstration of Better than Diesel Efficiency and Soot Emissions using Gasoline Compression Ignition in a Light Duty Engine with a Fuel Pressure Limitation

Increasing regulatory demand to reduce CO2 emissions has led to a focus on advanced combustion strategy development to improve overall engine efficiency. Gasoline compression ignition (GCI) has been demonstrated by others to have the potential to meet future CO2 regulations and emissions while achieving comparable to better efficiency than conventional diesel compression ignition (DCI). Soot and NOx emissions are also reduced significantly by using gasoline instead of diesel in compression ignition engines due to differences in composition, fuel properties, and reactivity. In comparison with diesel fuel, gasoline has a higher volatility and more resistance to autoignition, therefore, its longer ignition delay time will allow for better mixing of the air-fuel charge before combustion. In this study, a GCI combustion system has been tested in a Hyundai 2.2L engine as part of a US Department of Energy funded project. A double-injection strategy was tested from mid-to-high loads (5-20 bar BMEP) and for engine speeds in the range of 1200-3000 rpm. Up to 43.4% brake thermal efficiency was achieved using the GCI mode versus 41% using DCI mode. The GCI mode has demonstrated two distinct strategies that work at different load ranges, partially premixed compression ignition (PPCI) and mixing-controlled compression ignition (MCCI). Overall, this study shows that for similar engine-out NOx levels, GCI mode had higher brake thermal efficiency than DCI with lower fuel pressure and EGR required.

02 PETROLEUM↗

EPCAPE-PT-LANL Measurements: Single Particle Soot Photometer

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Single Particle Soot Photometer (Droplet Measurements Technology) Data Notes: Contact us if you want additional data products from this instrument. Reported data is the black carbon (rBC) number and mass concentration with diagnostic flags. The SP2 measures incandescence from particles that is induced with a 1064 Nd-YAG laser. Particles that absorb the laser energy and then emit radiation is assumed to contain black carbon. The amount of intensity of radiation is related to the mass of absorbing material in the particle. Here, we calibrate the incandescence intensity to size selected Regal Black (Cabot) nebulized from solution. Data provided for the EPCAPE campaign used the combined broadband high-gain + low-gain channels (BHBL). Each channel has a lower threshold of detection equivalent to 2-s of the respective channel noise. Thresholding has been applied to select between the high-gain and low-gain channels. The detection limit is 80-540 nm (Deq) or 0.36- 55 fg. It is assumed that rBC is the only aerosol type that is in significant concentration in the sampled atmosphere that absorbs the laser energy. Particle data are integrated over 10 second windows to calculate a rBC number and mass concentration. QC/QA: • Diagnostic flags that impacted measured concentration: - Sample, Sheath, and Purge Flow Rates: Despite observing fluctuations in all flows, the rBC detection and mass quantification are generally observed to be stable, although large changes in sample flow rate did impact detection efficiency. A flag was implemented for sample flow deviations >12 cm3/min from the set point averaged over 30 seconds - Laser Power: Detection efficiency decreases with laser power and deviations in laser power also affect mass quantification. Flag for laser power is set for deviations in laser current from the set value >5 mA. - Primary Detector Threshold: Primary thresholding is the signal value which determines whether a “particle” is recorded. Thresholding errors occur when the threshold value is too HIGH and real particles are ignored. • Several periods without data: - 16-18 Nov: Ultra Zero Air generator failure, flows deviated significantly from set points. rBC # conc recovered but questionable. - 20-21 Nov: Offline for calibrations for several hours each day. - 25-27 Nov: Data is missing. - 30 Nov: Power outage 3 Dec: SP2 hard-drive full. - 3 Dec: Power Outage Header: - BHBL_NumbConc[#/cc]: Refers to the number concentration of refractory black carbon (rBC) measured from combined broadband high-gain and low-gain channels, expressed in particles per cubic centimeter. - BHBL_BCMass_Conc[ug/m3]: Refers to the mass concentration of refractory black carbon (rBC) measured from combined broadband high-gain and low-gain channels, expressed in micrograms per cubic meter. - NoData_Flag[bool]: A boolean flag that indicates whether no data was recorded during a measurement. - NoBC_Flag[bool]: A boolean flag indicating whether no black carbon particles were recorded during the measurement. - Laser_Flag[bool]: A boolean flag indicating deviations in laser current during the measurement. - SampleFlow_Flag[bool]: A boolean flag indicating deviations from the set sample flow rate during the measurement. - PrimThresh_Flag[bool]: A boolean flag indicating deviations from the set primary threshold during the measurement, potentially ignoring real particles. - Manual_Flag[bool]: A boolean flag indicating manual intervention or adjustments during the measurement. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active or inactive during the measurement.

54 ENVIRONMENTAL SCIENCES↗

EPCAPE-PT-LANL Measurements: Soot Particle Aerosol Mass Spectrometer

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Soot particle-Aerosol Mass Spectrometer. (Aerodyne Inc.) Header: - Organic_GCVIoff[ug/m3]: Concentration of organic compounds measured via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Nitrate_GCVIoff[ug/m3]: Concentration of nitrate measured via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Sulfate_GCVIoff[ug/m3]: Concentration of sulfate measured via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Chloride_GCVIoff[ug/m3]: Concentration of chloride measured via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Ammonium_GCVIoff[ug/m3]: Concentration of ammonium via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Organic_GCVIon[ug/m3]: Concentration of organic compounds measured in-cloud via CVI in micrograms per cubic meter. - Nitrate_GCVIon[ug/m3]: Concentration of nitrate measured in-cloud via CVI in micrograms per cubic meter. - Sulfate_GCVIon[ug/m3]: Concentration of sulfate measured in-cloud via CVI in micrograms per cubic meter. - Chloride_GCVIon[ug/m3]: Concentration of chloride measured in-cloud via CVI in micrograms per cubic meter. - Ammonium_GCVIon[ug/m3]: Concentration of ammonium measured in-cloud via CVI in micrograms per cubic meter. - CVI_Flag[bool]: A boolean flag indicating whether the CVI was active (true) or inactive (false) during the measurement.

54 ENVIRONMENTAL SCIENCES↗