At least 91 records · Page 5

KCMP Minnesota Tall Tower Nitrous Oxide Inverse Modeling Dataset 2010-2015

This data set contains nitrous oxide mixing ratios and supporting information measured at a tall tower (KCMP, 244 meter) site near St. Paul, Minnesota, USA. The data include nitrous oxide and carbon dioxide mixing ratios measured at the 100 meter level. Turbulence and wind data were measured using a sonic anemometer at the 185 meter level. Also included in this data set are estimates of the “background” nitrous oxide mixing ratios. This data was collected to improve understanding of the reactive nitrogen budget for the region.

54 ENVIRONMENTAL SCIENCES↗

KCMP Minnesota Tall Tower Ammonia Observations and Emission Estimates Dataset 2017-2018

This data set contains NH3 mixing ratios, net ecosystem NH3 exchange, and supporting information measured at a tall tower (KCMP, 244 meter) site near St. Paul, Minnesota, USA. The data include NH3 and H2O mixing ratios measured at the 100 meter level, as well as NH3 mixing ratio measured at the 56 meter level. Wind data was measured using a sonic anemometer at the 185 meter level. Also included in this data set are values of wet N and NH3 deposition from 2016 - 2018. This data was collected to improve understanding of the ammonia and reactive nitrogen budget for the region.Ammonia mixing ratios were filtered for periods when the NH3 analyzer measured anomalous (i.e. 10 mmol mol-1) water vapor mixing ratios based on comparison with the IRGA (LI7000). Further, we filtered out NH3 observations obtained during strongly condensing conditions. These periods were identified when the water vapor mixing ratio differences between the 100 m and 56 m levels were more negative than -0.5 mmol mol-1 (i.e. when the water vapor gradient was strong and directed toward the land surface). Finally, we filtered out NH3 fluxes when the atmosphere was strongly stable (i.e. when (z-d)/L exceeded a value of +4.5) and subject to decoupling from the surface fluxes. Approximately 35.1% of the hourly flux data were either missing due to instrument failure or filtered according to the above quality control procedures.

54 ENVIRONMENTAL SCIENCES↗

CROCUS High-Frequency Measurements of CO₂, H₂O, Wind, and Temperature at University of Illinois Chicago

As of April 9, 2026: this dataset is currently being versioned to include data up to March 31, 2026. Once the versioning process is complete, new data files will be available for access. The dataset metadata will also be updated to reflect the data availability of the new data being versioned. Raw atmospheric measurements collected at the University of Illinois Chicago (UIC) as part of the Community Research on Climate and Urban Science (CROCUS) project. The data includes high-frequency measurements of carbon dioxide (CO₂) concentration, water vapor (H₂O) concentration, wind speed (U, V, W components), temperature, and atmospheric pressure. These raw data are recorded by the LI-7500DS Open Path CO₂/H₂O Analyzer and a sonic anemometer at a 10 Hz acquisition frequency, providing the necessary inputs for calculating fluxes of CO₂, H₂O, heat, and momentum. In addition to gas concentration measurements, the dataset includes diagnostic information from the instruments, including absorptance, sample and reference signals, and diagnostic values. The data were collected to study urban atmospheric conditions and contribute to flux calculations for urban climate research. These measurements form the basis for calculating 30-minute average fluxes of key atmospheric variables using the eddy covariance method. This dataset provides critical raw input data for researchers interested in atmospheric fluxes, urban air quality, and the interaction between the urban environment and atmospheric processes. The data is part of the U.S. Department of Energy’s Biological and Environmental Research (BER) program, under the CROCUS Urban Integrated Field Laboratory (UIFL) project.

54 ENVIRONMENTAL SCIENCES↗

AmeriFlux US-ARM ARM Southern Great Plains site- Lamont

This is the AmeriFlux version of the carbon flux data for the site US-ARM ARM Southern Great Plains site- Lamont. Site Description - Central facility tower crop field (winter wheat, corn, soy, alfalfa). The site also has continuous measurements of precise mixing ratios of CO2, CH4, CO, N2O, and isotopic ratio of 13CO2. In addition to 4 m system, there are sonic anemometers at 25 m and 60 m.

Biraud, Sebastien↗

AmeriFlux US-Bsg Burns Sagebrush

This is the AmeriFlux version of the carbon flux data for the site US-Bsg Burns Sagebrush. Site Description - The site was established in 2012 and is part of a NOAA observation network for high precision measurements of carbon dioxide concentrations. It is located about 60 km southwest of Burns, Oregon in the Oregon High Desert. The vegetation in this area is dominated by sagebrush. The sampling inlets are at the heights of 18.5, 28.5, and 38.5 m. Gas analysis is performed with a Picarro 2302 Cavity Ringdown Spectrometer and a Li-Cor 7200 enclosed path IRGA. The tower is also equipped with a set of meteorological instruments, including an HMP sensor, radiation sensors (incoming and diffuse PAR, Net radiometer), and a CSAT3 sonic anemometer. This site is also part of the PhenoCam network operated by Harvard University and the University of New Hampshire.

Still, Chris↗

AmeriFlux FLUXNET-1F US-ARM ARM Southern Great Plains site- Lamont

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-ARM ARM Southern Great Plains site- Lamont. This is the FLUXNET version of the carbon flux data for the site US-ARM ARM Southern Great Plains site- Lamont produced by applying the standard ONEFlux (1F) software. Site Description - Central facility tower crop field (winter wheat, corn, soy, alfalfa). The site also has continuous measurements of precise mixing ratios of CO2, CH4, CO, N2O, and isotopic ratio of 13CO2. In addition to 4 m system, there are sonic anemometers at 25 m and 60 m.

Biraud, Sebastien↗

Eddy Correlation Flux Measurement System (ECOR) Instrument Handbook

The eddy correlation (ECOR) flux measurement system provides in situ, half-hour measurements of the surface turbulent fluxes of momentum, sensible heat, latent heat, and carbon dioxide (CO 2 ) (and methane at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s North Slope of Alaska central facility [NSA Barrow], and at the ARM Mobile Facility (AMF) deployment at Oliktok Point). The fluxes are obtained with the eddy covariance technique, which involves correlation of the vertical wind component with the horizontal wind component, the air temperature, the water vapor density, and the CO 2 concentration. The instruments used are: a fast-response, three-dimensional (3D) wind sensor (sonic anemometer) to obtain the orthogonal wind components and the speed of sound (SOS) (used to derive the air temperature), an open-path infrared gas analyzer (IRGA) to obtain the water vapor density and the CO 2 concentration, and an open-path infrared gas analyzer (IRGA) to obtain methane density and methane flux at NSA Barrow and at the AMF deployment at Oliktok Point. The ECOR systems are deployed at the locations where other methods for surface flux measurements (e.g., energy balance Bowen ratio [EBBR] systems) are difficult to employ, primarily at the north edge of a field of crops. A surface energy balance system (SEBS) has been installed collocated with each deployed ECOR system in SGP, NSA, Tropical Western Pacific (TWP), and each of three ARM Mobile Facilities. The surface energy balance system consists of upwelling and downwelling solar and infrared radiometers within one net radiometer, a wetness sensor, and soil measurements. Finally, the SEBS measurements allow the comparison of ECOR sensible and latent heat fluxes with the energy balance determined from the SEBS and provide information on wetting of the sensors for data quality purposes.

47 OTHER INSTRUMENTATION↗

Tools for Assessing Performance Project: FY2021 Quarter 4 Report

The rotatable building located at Texas Tech’s Reese Technology Center is approximately 14 m wide (width being defined as more normal to the wind than parallel), 9 m long (aligned more with the wind than perpendicular), and 4 m tall. By placing 29 sonic anemometers downwind of the building, see Fig. 1, this facility provided a chance to collect data concerning both the wake velocity deficit distribution in the downstream and crosssteam directions (relative to the mean wind) behind an isolated building. A preliminary comparison between this data and the recently- developed fast-running diffusive wake model, which was developed based on wind tunnel and LES (performed with JOULES) simulations, for the purpose of either validating this model of understanding potential persistent differences between the idealized wind tunnel or LES conditions and those of full-scale real world phenomena. For this preliminary exploration, we utilized the diffusive wake model implemented in the QUIC model.

42 ENGINEERING↗

Automated Generation of Weather and Climate Analysis Products

Wind roses are an important part to site operations as they depict the wind speed and direction percentage over a time period. In this project, I automated the production of wind roses for SRS meteorological towers. I developed a script to sequence through the dataset by period and create a wind rose for each of those period sets. Graphics were generated for every 4-hour period of the day, for each of the 4 heights of the instruments, for every half of each month. A 10-year climatological period consisted of wind speed and directions measurements at 15-minute intervals. We used the years 2014-2024 as the wind instruments on the tower were upgraded to sonic anemometers in early 2014. I then compared these wind roses to those from a previous study done in 2003 to analyze the differences and similarities in the wind patterns. The wind roses are also used to understand environmental transport conditions at SRS. When comparing the different heights of the anemometers to the 2003 report, there is a similarity in the fact that the direction is relatively the same across the levels, with the wind speeds increasing as you get higher in the air. When comparing the season of our graphs against the 2003 report, we noticed that the winter and summer months appear to have very similar wind directions. However, in the spring we noticed that there were more southerly winds compared to the 2003 report which had more westerly winds. Finally, in the fall months, we noticed that there was a higher percentage of northeasterly winds, while the 2003 report showed more southeasterly winds. We can use these summaries to estimate the directional dependence of dose that the surrounding areas receive throughout the year according to time of day.

47 OTHER INSTRUMENTATION↗

Acoustic Tomography System (CRADA Final Report)

NREL will install the CU/CIRES acoustic tomography array at the National Wind Technology Center (NWTC). The system consists of 9 freestanding towers of 9.1m height that are currently located at the NWTC. On these towers are installed a series of microphones and speakers. One center tower holds a sonic anemometer and temperature probe. The purpose of the acoustic tomography system is to measure complex flow fields surrounding wind turbine arrays that influence wind farm energy production and reliability. There is currently no funding to test and research the system (just install it), but NREL and CU researchers will write proposals that will fund the actual research with this unique measurement technology.

17 WIND ENERGY↗

Wind River Experimental Forest Subcanopy Tower Information Sheet

Wind River was one of three sites that collected 3d sonic anemometer data for an ICOS subcanopy observation study. The three sites were defined by the following features and terrain: a deciduous broadleaf forest in flat terrain (Lanžhot, Czech Republic), a coniferous forest in mountainous terrain (Renon, Italy), and a tall conifer forest in mountain-valley terrain (Wind River, USA). The Wind River subcanopy towers were deployed in a high LAI, old-growth evergreen conifer forest and collected approximately 11 months of data. The site is an ecologically rich temperate rainforest in the western Cascade Mountains, and the biological carbon sink and source strength has been measured since 1998 using eddy covariance on the top of a 74 m tall flux tower (currently called the Wind River NEON tower). Additionally, forest inventory records date back to the 1920s. In 2024, four subcanopy towers were installed near the Wind River NEON tower to measure wind flow in the understory canopy layer for better understanding canopy flow coupling and decoupling in the subcanopy and how this affects the interpretation of overstory fluxes. The subcanopy tower installation was done by Lawrence Livermore National Laboratory and Washington State University (WSU) with collaborations from the University of Utah and the National Ecological Observatory Network (NEON).