Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Solid state detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Hybrid X-ray telescope systems

It has been known for some time that glancing incidence X-ray optics have sharply peaked point response functions. The spatial resolution of Wolter X-ray telescope systems is frequently limited by the performance characteristics of the X-ray detector rather than by the optics, even when high resolution detectors such as photographic emulsions are used. This problem becomes even more severe when it is desirable to take advantage of the high sensitivity and broad wavelength response afforded by modern solid state detectors such as charge coupled devices or multi-anode microchannel arrays. Results of theoretical investigations of methods for increasing the telescope plate scale by the use of glancing incidence hyperboloid/ellipsoid X-ray microscope optics and normal incidence contoured layered synthetic microstructure optics for coupling the Wolter mirrors to the detector are reported. The relative merits of the different hybrid X-ray telescope systems which result will be discussed. Considerations will be made concerning applications of these systems to high resolution imagery and spectroscopy of astronomical X-ray/XUV sources.

Shealy, David L.↗

A sub-5 ps jitter time-to-digital converter ASIC with back-gate delay tuning in 22 nm CMOS

We present the design of a Time-to-Digital Converter (TDC) ASIC together with performance characterization results at cryogenic temperature (6-8 K), and at room temperature using emulated Low-Gain Avalanche Detector (LGAD) signals. The TDC design uses a two-step architecture with a ring-oscillator based counter and a Vernier delay line fine TDC. The TDC is implemented in an FD-SOI process, and back-gate tuning is used not only to correct threshold variation due to cryogenic operation, but also as a novel way to tune TDC delay elements with very little overhead. Using this technique, we demonstrate a design with very low power (0.5 mW) and area (0.003 mm 2 ). We present test results using the Fermilab Constant Fraction Discriminator (FCFD) ASIC to produce discriminated signals from an internal charge injection mechanism that mimics the waveform and signal amplitude of minimum ionizing particles impinging on LGAD sensors. We characterize the time precision of the full system and verify that the TDC ASIC contributes a negligible amount to the total system time precision, fully consistent with the expected jitter contribution of less than 5 ps. In conclusion, the results presented here demonstrate the utility of our TDC for applications in physics and quantum communications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Techniques in balloon X-ray astronomy.

Since the first balloon observation of the Crab Nebula balloon data have provided much information on the positions, spectra, time variability and pulsed nature of localized sources, and on the spectrum and isotropy of diffuse galactic and universal components. Measurements are limited to energies above about 20 keV by atmospheric attenuation at 2 to 3 g/sq cm depth and to below several hundred keV by detector sensitivity. Detectors usually consist of large-area Na I or Cs I scintillation counters with anticoincidence collimators for rejection of charged particles and scattered X-rays. Proportional counters are occasionally used at lower energies and solid-state detectors are used where extreme energy resolution is important. The instruments require a pointing capability on the order of 1.0 to 0.1 deg, depending on the collimator aperture. Digital data is either recorded on board or telemetered using a PCM technique.

Peterson, L. E.↗

Si and GaAs photocapacitive MIS infrared detectors

Improvement of the previously reported photocapacitive MIS infrared detectors has led to the development of exceptional room-temperature devices. Unoptimized peak detectivities on the order of 10 to the 13th cm sq rt Hz/W, a value which exceeds the best obtainable from existing solid-state detectors, have now been consistently obtained in Si and GaAs devices using high-capacitance LaF3 or composite LaF3/native-oxide insulating layers. The measured spectral response of representative samples is presented and discussed in detail together with a simple theory which accounts for the observed behavior. The response of an ideal MIS photocapacitor is also contrasted with that of both a conventional photoconductor and a p-i-n photodiode, and reasons for the superior performance of the MIS detectors are given. Finally, fundamental studies on the electrical, optical, and noise characteristics of the MIS structures are analyzed and discussed in the context of infrared-detector applications.

Sher, A.↗

Apparatus and method using a holographic optical element for converting a spectral distribution to image points

A holographic optical element transforms a spectral distribution of light to image points. The element comprises areas, each of which acts as a separate lens to image the light incident in its area to an image point. Each area contains the recorded hologram of a point source object. The image points can be made to lie in a line in the same focal plane so as to align with a linear array detector. A version of the element has been developed that has concentric equal areas to match the circular fringe pattern of a Fabry-Perot interferometer. The element has high transmission efficiency, and when coupled with high quantum efficiency solid state detectors, provides an efficient photon-collecting detection system. The element may be used as part of the detection system in a direct detection Doppler lidar system or multiple field of view lidar system.

McGill, Matthew J.↗

Detectors for energies greater than 10 MeV

The detector telescopes used in gamma ray astronomy in general are more similar to particle detectors than to optical devices, since the high frequency of the radiation precludes the use of reflection or diffraction techniques, but the high energy content of each photon does enable them to be detected with scintillators, track imaging chambers, and solid state detectors. Within the gamma ray range, the basic design of the instrument changes as the energy of the gamma ray exceeds 10 to 20 MeV, and therefore, moves from the region where the Compton effect predominates in the absorption of the gamma ray to that where electron pair production is most important. In the energy range from 10 to 20 MeV to several times 10,000 MeV, gamma ray telescopes are usually built so that the electron pair may be seen and the properties of the electrons measured.

Source record↗

Rocket observations of energetic particles at the geomagnetic equator

Energetic particle detectors were included in the payloads of two rockets launched in Peru during the Condor campaign of 1983. These night-time flights reached altitudes of 587 and 535 km, respectively. The pitch-angle distribution is anisotropic with the maximum at 90 deg. Each payload included two solid-state detectors differing in the thickness of the aluminum coating. Comparison of the fluxes measured by the two detectors leads to the conclusion that, on both occasions, the energetic particles are predominantly helium ions. The flux is small below 200 km, increases linearly to 350 km, and then more slowly to apogee. The east-west asymmetry of flux, noted at 200 km in a previous equatorial launch, is not seen at greater altitudes, consistent with the flux profile and the large gyroradius of the ions.

Smith, L. G.↗

Molecular and Elemental Dust Analyzer (MEDA) for the comet rendezvous asteroid flyby mission

Comets are some to the most primitive bodies in the solar system and therefore should contain elemental, chemical, and isotopic records of the early history of the solar system. An opportunity to perform in situ analyses of a comet nucleus exists with the Comet Rendezvous Asteroid Flyby (CRAF) mission. An integrated gas chromatograph/X-ray fluorescence instrument (MEDA), being proposed for inclusion onboard the CRAF spacecraft, will measure the molecular and elemental constituents of collected dust grains and ices. The gas chromatograph, employing helium ionization detectors and three columns designed to separate light gases, polar gases, and hydrocarbons will measure the volatile compounds of the biogenic elements thermally released from collected dust grains. The sensitivity of the GC for compounds of interest is at the picogram level. X-ray fluorescence utilized cryogenically cooled Si(Li) solid state detectors of nominal 150 eV resolution at 5.9 keV. Based on laboratory work with carbonaceous meteorites, both the GC and XRF can perform meaningful analyses with a few micrograms of collected comet dust.

Ohara, B. J.↗

Delta-Doped CCDs as Detector Arrays in Mass Spectrometers

In a conventional mass spectrometer, charged particles (ions) are dispersed through a magnetic sector onto an MCP at an output (focal) plane. In the MCP, the impinging charged particles excite electron cascades that afford signal gain. Electrons leaving the MCP can be read out by any of a variety of means; most commonly, they are post-accelerated onto a solid-state detector array, wherein the electron pulses are converted to photons, which, in turn, are converted to measurable electric-current pulses by photodetectors. Each step in the conversion from the impinging charged particles to the output 26 NASA Tech Briefs, February 2007 current pulses reduces spatial resolution and increases noise, thereby reducing the overall sensitivity and performance of the mass spectrometer. Hence, it would be preferable to make a direct measurement of the spatial distribution of charged particles impinging on the focal plane. The utility of delta-doped CCDs as detectors of charged particles was reported in two articles in NASA Tech Briefs, Vol. 22, No. 7 (July 1998): "Delta-Doped CCDs as Low-Energy-Particle Detectors" (NPO-20178) on page 48 and "Delta- Doped CCDs for Measuring Energies of Positive Ions" (NPO-20253) on page 50. In the present developmental miniature mass spectrometers, the above mentioned miniaturization and performance advantages contributed by the use of delta-doped CCDs are combined with the advantages afforded by the Mattauch-Herzog design. The Mattauch- Herzog design is a double-focusing spectrometer design involving an electric and a magnetic sector, where the ions of different masses are spatially separated along the focal plane of magnetic sector. A delta-doped CCD at the focal plane measures the signals of all the charged-particle species simultaneously at high sensitivity and high resolution, thereby nearly instantaneously providing a complete, high-quality mass spectrum. The simultaneous nature of the measurement of ions stands in contrast to that of a scanning mass spectrometer, in which abundances of different masses are measured at successive times.

Nikzad, Shouleh↗

The MERiT Onboard the CeREs: A Novel Instrument to Study Energetic Particles in the Earth's Radiation Belts

The Miniaturized Electron pRoton Telescope, MERiT, is a low‐mass, low‐power, compact instrument using an innovative combination of particle detectors, sensor electronics, and onboard processing. MERiT is flying on the Compact Radiation belt Explorer, CeREs, a 3U CubeSat launched into a low earth orbit of 500‐km altitude and inclination of 85° on 16 December 2018. The primary and secondary science goals of CeREs are to investigate electron microbursts and to study solar particles. MERiT comprises a stack of solid state detectors (SSD) behind space facing avalanche photo diodes (APDs) surrounded by W‐Al shielding to reduce side‐penetrating particle background. The APD‐SSD combination enables measurement of electrons from 5 to 200 keV and 1 to 8 MeV; protons from 200–400 keV and 7–100 MeV in differential channels with energy resolution ΔE/E≈30% for both electrons and protons. MERiT measures microbursts with a high time resolution ranging from 4 to 16 ms and solar particles with a cadence of 1 s. MERiT energy channels and cadences are software configurable via algorithms and lookup tables residing on a field‐programmable gate array. The lookup tables can be changed via ground commands. MERiT geometry factor is 31 sq.cm‐sr and optimized to measure microbursts with the instrument viewing the local zenith in orbit. MERiT enables investigation of dynamical processes of radiation belt electron energization and loss, solar electron and proton transport, and their access to the Earth's polar caps. We describe the MERiT sensor design, calibration, operational modes, data products, and science goals.

Kanekal, S. G.↗

Development of High Energy Resolution Fluorescence Detection Methods for Advanced Microscale X-ray Absorption Fine Structure Analysis of Critical Elements (Final Report)

This project is developing High-Energy Resolution Fluorescence Detection (HERFD) X-ray Absorption Fine-Structure Spectroscopy (XAFS) at the hard X-ray microprobe beamline at GSECARS beamline 13-ID-E, at the Advanced Photon Source at Argonne National Laboratory. This enhancement will improve sensitivity and spectral interpretation limitations of conventional XAFS which uses energy dispersive solid-state detectors (SSD) to measure the total fluorescence yield (TFY-XAFS). By using high-quality Si and Ge crystal analyzers to select X-ray fluorescence (XRF) from specific emission lines, background signals from other elements or X-ray scattering that can paralyze SSDs can be nearly eliminated, improving the sensitivity to the oxidation and chemical state of dilute species even though the solid angle of the analyzers is relatively small. Furthermore, by using analyzers of low-strain Si or Ge, the energy selection can be smaller than the natural widths of the core electron level. We are particularly interested in applying these enhanced sensitivities to Lanthanide series of rare-earth elements, which are typically at concentrations at or below 10 ppm, and where spectral overlaps with the 3rd row transition metals degrade sensitivity.

47 OTHER INSTRUMENTATION↗

Hybrid AlGaN-SiC Avalanche Photodiode for Deep-UV Photon Detection

The proposed device is capable of counting ultraviolet (UV) photons, is compatible for inclusion into space instruments, and has applications as deep- UV detectors for calibration systems, curing systems, and crack detection. The device is based on a Separate Absorption and Charge Multiplication (SACM) structure. It is based on aluminum gallium nitride (AlGaN) absorber on a silicon carbide APD (avalanche photodiode). The AlGaN layer absorbs incident UV photons and injects photogenerated carriers into an underlying SiC APD that is operated in Geiger mode and provides current multiplication via avalanche breakdown. The solid-state detector is capable of sensing 100-to-365-nanometer wavelength radiation at a flux level as low as 6 photons/pixel/s. Advantages include, visible-light blindness, operation in harsh environments (e.g., high temperatures), deep-UV detection response, high gain, and Geiger mode operation at low voltage. Furthermore, the device can also be designed in array formats, e.g., linear arrays or 2D arrays (micropixels inside a superpixel).

Aslam, Shahid↗

Advanced Radiation Detectors and Detector Systems Research

Real‐time awareness of space radiation is critical for missions beyond LEO. Missions to the Moon, Mars, Near‐Earth‐Objects (NEOs), inner and outer planets, as well as other destinations in space, will require embedded instrumentation to provide feedback for “smart”, adaptive control systems. Precision instrumentation will also be needed to provide improved data for space radiation modeling and space weather forecasting and awareness. Compact instrumentation on small platforms such as CubeSats and other small space‐faring vehicles will provide a better understanding of the space radiation environment by supplying data from multiple locations in space where information is yet unknown. Compact integrable solid‐state detectors with low noise and high tolerance of operation in a radiation environment are enabled by the application of Wide Band Gap semiconductors as radiation detectors. NASA Glenn Research Center (GRC) is applying its expertise and facilities in harsh environment instrumentation to develop supporting technologies that enable improved instruments for space science missions. A variety of radiation detectors are under development, such as silicon carbide semiconductor detectors, for applications to space science, lunar prospecting, and fission power systems.

Field and particle detectors↗

Shielded Heavy-Ion Environment Linear Detector (SHIELD): an experiment for the Radiation and Technology Demonstration (RTD) Mission

Radiological assessment of the many cosmic ion species of widely distributed energies requires the use of theoretical transport models to accurately describe diverse physical processes related to nuclear reactions in spacecraft structures, planetary atmospheres and surfaces, and tissues. Heavy-ion transport models that were designed to characterize shielded radiation fields have been validated through comparison with data from thick-target irradiation experiments at particle accelerators. With the RTD Mission comes a unique opportunity to validate existing radiation transport models and guide the development of tools for shield design. For the first time, transport properties will be measured in free-space to characterize the shielding effectiveness of materials that are likely to be aboard interplanetary space missions. Target materials composed of aluminum, advanced composite spacecraft structure and other shielding materials, helium (a propellant) and tissue equivalent matrices will be evaluated. Large solid state detectors will provide kinetic energy and charge identification for incident heavy-ions and for secondary ions created in the target material. Transport calculations using the HZETRN model suggest that 8 g cm -2 thick targets would be adequate to evaluate the shielding effectiveness during solar minimum activity conditions for a period of 30 days or more.

NASA Center LaRC↗

In-Situ Spectrometry of Neutrons

High energy charged particles of extra-galactic, galactic and solar origin collide with spacecraft structures in Earth orbit outside the atmosphere and in interplanetary travel beyond the Earth's magnetosphere. These primaries create a number of secondary particles inside the structures that can produce a significant ionizing radiation environment. This radiation is a threat to long term inhabitants or travelers for space missions and produces an increased risk of cancer and DNA damage. The primary high energy cosmic rays and trapped protons collide with common spacecraft materials such as aluminum and silicon and create secondary particles inside structures that are mostly protons and neutrons. Charged protons are readily detected and instruments are already in existence for this task. Neutrons are electrically neutral and therefore much more difficult to measure and detect. These neutrons are reported to contribute 30-60% of the dose inside space structures and cannot be ignored. Currently there is no compact, portable and real time neutron detector instrumentation available for use inside spacecraft or on planetary surfaces where astronauts will live and work. We propose to design and build a portable, low power and robust neutron spectrometer that will measure the neutron spectrum from 10 KeV to 500 MeV with at least 10% energy resolution in the various energy intervals. This instrument will monitor the existing neutron environment both inside spacecraft structures and on planetary surfaces to determine the safest living areas, warn of high fluxes associated with solar storms and assist the NSBRI Radiation Effects Team in making an accurate assessment of increased cancer risk and DNA damage to astronauts. The instrument uses a highly efficient proportional counter Helium 3 tube at the lowest energy intervals where .equivalent damage factors for tissue are the highest (10 KeV-2 MeV). The Helium 3 tube may be shielded with a cadmium absorber to eliminate the much less damaging, but more prevalent, thermal and epithermal neutrons and to make the structure of the spectrum more accurate in the 20 KeV-2 MeV range; or a pair of tubes, one shielded and one unshielded, can be combined so that the difference in their counts yields the thermal neutron contribution. The spectrometer also uses a 5mm lithium drifted bulk silicon solid state detector in the medium energy range of 2-20 Mev and two standard silicon surface barrier detectors separated by tens of millimeters behind a I cm thick polyethylene moderator in a stack or telescope arrangement for the high energy neutrons (>20 MeV). In the medium and high energy regions equivalent damage factors are lower but hits from one or a small number of neutrons may prove to be important. The silicon detector systems for medium and high energy neutrons will discriminate against charged particles by using a plastic cesium iodide scintillator of an appropriate geometry monitored by a silicon PIN photodiode.

Maurer, Richard H.↗

Pixel response characterization of the ARCADIA fully depleted MAPS

Monolithic Active Pixel Sensors (MAPS) achieved widespread use in several scientific applications, thanks to their properties, such as low material budget and high granularity. The ARCADIA INFN project developed a Fully-Depleted MAPS (FD-MAPS), using a modified LFoundry 110 nm CIS process. This work presents the first laboratory characterization of the ARCADIA MD3 prototype. Measurements include threshold uniformity studies using both test-pulse injection and a 55 Fe source, as well as threshold and noise calibration achieved thanks to monochromatic X-ray sources. Ultimately, charge-collection efficiency is evaluated using an infrared laser setup.

Particle tracking detectors↗

The DAMIC-M Low Background Chamber

The DArk Matter In CCDs at Modane (DAMIC-M) experiment isdesigned to search for light dark matter (m$_{χ}$ < 10 GeV/c$^{2}$)at the Laboratoire Souterrain de Modane (LSM) in France. DAMIC-Mwill use skipper charge-coupled devices (CCDs) as a kg-scale activedetector target. Its single-electron resolution will enable eV-scaleenergy thresholds and thus world-leading sensitivity to a range ofhidden sector dark matter candidates. A DAMIC-M prototype, the LowBackground Chamber (LBC), has been taking data at LSM since2022. The LBC provides a low-background environment, which has beenused to characterize skipper CCDs, study dark current, and measureradiopurity of materials planned for DAMIC-M. It also allows testingof various subsystems like readout electronics, data acquisitionsoftware, and slow control. This paper describes the technicaldesign and performance of the LBC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Individual and Simultaneous Imaging of ⁹⁹mTc and ¹⁷⁷Lu With a Preclinical Broad Energy-Spectrum CZT-Based SPECT

Radiopharmaceutical therapy has demonstrated a high efficacy in the treatment of various tumor types. One of the radionuclides already used in the clinic is 177Lu, a beta emitter that also emits several photons imageable with SPECT. Quantitative imaging of 177Lu is critical for developing new radiopharmaceuticals. Energy resolution is an important factor when imaging multiple photon emissions. Solid-state detectors offer a superior performance over scintillators, that are commonly used in commercially-available preclinical SPECT scanners. This study demonstrates the feasibility of 99m Tc and 177Lu quantitative imaging in mouse phantoms, individually and simultaneously, with a SPECT prototype built with four CdZnTe (CZT) detector heads and a custom-designed and energy-optimized parallel-hole tungsten collimator. With a custom implementation of the one-step late (OSL) image reconstruction algorithm, the system is capable of imaging energies from ~70 keV to 250 keV. Above 250 keV, images were significantly affected by septal penetration, consistent with the collimator design. A recovery coefficient within 25% was obtained for activities as low as 2 kBq/mL for 99m Tc and 45% for 177Lu. Compared to a commercial NaI-based preclinical SPECT (VECTor4/CT), our prototype showed a superior energy resolution (< 5% at 140 keV), a similar uniformity with a high-compact design.

Encarnação, Pedro M C C↗