Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Solar PV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Solar PV Curtailment in Changing Grid and Technological Contexts: Preprint

Solar photovoltaic (PV) systems generate electricity with no marginal costs or emissions. As a result, PV output is almost always prioritized over other fuel sources and delivered to the electric grid. At increasing levels of PV penetration situations arise where PV is curtailed, either because of local supply/demand imbalances or to maintain system flexibility. In 2018, we estimate that about 6.5 million MWh of PV output was curtailed in four key countries: Chile, China, Germany, and the United States. We find that PV curtailment peaks in the spring and fall, when PV output is relatively high but electricity demand is relatively low. Similar to the case of wind, some PV curtailment is attributable to limited transmission capacity connecting sparsely populated solar-heavy regions to load centers.Grid policies generally seek to minimize curtailment because it is viewed as an economic and environmental loss. However, we argue that changing grid and technological contexts warrant new thinking on PV curtailment. In the grid context, as grids integrate more PV and other renewable energy generation, seeking an optimal level of accepted curtailment becomes more efficient than preventing it. In the technological context, emerging technologies such as advanced inverters and low-cost battery storage are making PV systems more flexible. With flexible PV, grid operators can use withheld PV output to provide various non-generation grid services. This withheld PV output is a form of curtailment under prevailing definitions of the term. Hence, policies that aim to minimize curtailment may undercut the ability of grid operators to fully use the emerging capabilities of flexible PV systems. We argue that the changing grid and technological contexts require a re-examination of the curtailment paradigm. We argue that PV output that is withheld to provide grid services is fundamentally different from output that goes unused in response to system constraints. As a result, we propose a more exclusive definition of curtailment as unused PV output rather than the more expansive conventional definition as any reduction in system output from its technical potential. The terminological distinction is more than a question of semantics. Facilitating grid services by withholding PV output may increase the potential value of flexible PV systems to the grid. This shift in thinking may allow grid operators and policymakers to think in terms of PV curtailment management rather than minimization. Effective curtailment management may include policies that increase PV system dispatchability, alternative PV compensation schemes that decouple generator revenue from system output, and policies to increase grid flexibility.

Chile↗

Building efficiency, electrification, and distributed solar PV bill savings under time-based retail rate designs

Building energy technologies and distributed generation, including energy efficiency (EE), distributed solar PV (DPV), and building electrification, are critical to meeting decarbonization goals. Rate design may play an important role in determining the customer economics of adopting these technologies, but it is unclear whether – and to what extent – current rate design trends support or impede progress toward these goals. In this study, we answer these questions by quantifying the range of residential customer bill impacts of EE, DPV, and building electrification investments under current and emerging time-based retail electricity rate designs (i.e., time-of-use, event-based pricing, coincident demand charges, and real time pricing). We also compare these customer bill savings to power system and societal benefits and assess how well the investments are compensated relative to the societal value they provide.

14 SOLAR ENERGY↗

Hierarchical Control of Utility-Scale Solar PV Plants for Mitigation of Generation Variability and Ancillary Service Provision

This paper presents a hierarchical control system to mitigate the variability of solar photovoltaic (PV) power plant and provide ancillary services to the electric grid without the need for additional non-solar resources. With coordinated management of each inverter in the system, the control system commands the power plant to proactively curtail a small fraction of its instantaneous maximum power potential, which gives the plant enough headroom to ramp up production from the overall power plant, for a service such as regulation reserve. This control system is practical for continuously changing cloud cover conditions in partially cloudy days. A case study from a site in Hawaii with one-second resolution solar irradiance data is used to verify the efficacy of the proposed control system. The proposed control algorithm is subsequently compared with the alternative control technology from the literature, the grouping control algorithm; the results show that the proposed hierarchical control system is over 10 times more effective in reducing generator mileage to support power fluctuations from solar PV power plants.

14 SOLAR ENERGY↗

Knowledge spillovers between PV installers can reduce the cost of installing solar PV

We analyze pricing in PV systems using data from 2008-2014 to identify the effects of knowledge spillovers in reducing the installed cost of PV. This paper estimates the size of the effects of learning by doing and knowledge spillovers using multiple formulations of spillover related variables. We found knowledge spillovers between firms within a county to be a significant and substantial factor in reducing the costs of PV. However, these spillovers reduce costs only for firms over a certain size threshold, and no cost-reducing spillovers were found for smaller installers. Geographic spillovers, within a firm from one county to another were also significant although not as large as the local between-firm effects. We ran 43 specifications on the data and generally found these main results to be robust, although not in every specification. One implication of these results is that policies that subsidize demand for PV are leading to the creation of new knowledge that would not exist at lower levels of demand. Furthermore, that the spillovers become stronger at higher levels of experience suggests that these subsidies would need to be substantial, particularly in new markets with many small firms.

14 SOLAR ENERGY↗

Statistical Analysis of Solar PV Power Frequency Spectrum for Optimal Employment of Building Loads

In this paper, a statistical analysis of the frequency spectrum of solar photovoltaic (PV) power output is conducted. This analysis quantifies the frequency content that can be used for purposes such as developing optimal employment of building loads and distributed energy resources. One year of solar PV power output data was collected and analyzed using one-second resolution to find ideal bounds and levels for the different frequency components. The annual, seasonal, and monthly statistics of the PV frequency content are computed and illustrated in boxplot format. To examine the compatibility of building loads for PV consumption, a spectral analysis of building loads such as Heating, Ventilation and Air-Conditioning (HVAC) units and water heaters was performed. This defined the bandwidth over which these devices can operate. Results show that nearly all of the PV output (about 98%) is contained within frequencies lower than 1 mHz (equivalent to ~15 min), which is compatible for consumption with local building loads such as HVAC units and water heaters. Medium frequencies in the range of ~15 min to ~1 min are likely to be suitable for consumption by fan equipment of variable air volume HVAC systems that have time constants in the range of few seconds to few minutes. This study indicates that most of the PV generation can be consumed by building loads with the help of proper control strategies, thereby reducing impact on the grid and the size of storage systems.

boxplot↗

U.S. Wind and Solar PV Supply Curves with Future Land-use Change

This dataset provides future supply curves representing the total resource potential for land-based wind and solar photovoltaic (PV) deployment in the conterminous United States after accounting for the impact of land-use and land-cover change (LULC). We use LULC projections from 2010 to 2050 developed based on the Intergovernmental Panel on Climate Change (IPCC) Special Report on Emission Scenarios. The LULC projections are subsequently fed into the renewable energy potential model (reV), which estimates total available wind and solar capacity after excluding non-developable land. Supply curves are provided for four IPCC scenarios in 2050: A1B, A2, B1, and B2. As a baseline, we also provide the supply curve from the B2 scenario in 2010. In addition to the supply curves, we also provide representative wind and solar generation profiles for each supply curve point. These generation profiles are provided as capacity factors and are based on a 2012 weather year using NSRDB and WindToolkit resource data. For more details on the supply curve and profile datasets included here please refer to README. Additional information on the supply curves and the LULC projections used to generate them, as well as an analysis of their impact on wind and solar deployment under decarbonization can be found in the publication linked below: "U.S. Wind and Solar PV Supply Curves with Future Land-use Change Publication".

Array↗

Case Study: Link Logistics Industrial Solar PV

This case study describes how Link Logistics uses community solar programs and other internal procedures to increase NOI at a warehouse property through leasing roof space for solar installation.

solar, solar PV, photovoltaic, onsite solar, indus↗

On-Site Commercial Solar PV Decision Guide for the Healthcare Sector

This document provides guidance for hospitals and healthcare facilities concerning the implementation and potential benefits of on-site solar photovoltaics (PV). It includes best practices and considerations for each step of the decision-making process.

Healthcare, Solar, PV, Photovoltaic, solar PV, Hos↗

Weather impacts on solar PV operations summary of the current body of knowledge and implications for further investigation

There is growing concern that severe weather events are negatively affecting solar photovoltaic (PV) systems and pose ongoing and unrecognized risks. Clearly research is needed to quantify and characterize the risks so that properly calibrated improvements can be implemented. To begin this process, this report is a collection of information of severe weather impacts on solar PV available today taken from research, insurance data, and field inspections. While it is not comprehensive enough to draw conclusions, this information provides a baseline for action and indicates an urgent need to investigate further.

14 SOLAR ENERGY↗

Solar PV O&M Standards and Best Practices - Existing Gaps and Improvement Efforts

As greater numbers of photovoltaic (PV) systems are being installed, operations & maintenance (O&M) activities will need to be performed to ensure the PV system is operating as designed over its useful lifetime. To mitigate risks to PV system availability and performance, standardized procedures for O&M activities are needed to ensure high reliability and long-term system bankability. Efforts are just getting underway to address the need for standard O&M procedures as PV gains a larger share of U.S. generation capacity. Due to the existing landscape of how and where PV is installed, including distributed generation from small and medium PV systems, as well as large, centralized utility-scale PV, O&M activities will require different levels of expertise and reporting, making standards even more important. This report summarizes recent efforts made by solar industry stakeholders to identify the existing standards and best practices applied to solar PV O&M activities, and determine the gaps that have yet to be, or are currently being addressed by industry.

14 SOLAR ENERGY↗

Solar PV O&M Standards and Best Practices – Existing Gaps and Improvement Efforts

As greater numbers of photovoltaic (PV) systems are being installed, operations & maintenance (O&M) activities will need to be performed to ensure the PV system is operating as designed over its useful lifetime. To mitigate risks to PV system availability and performance, standardized procedures for O&M activities are needed to ensure high reliability and long-term system bankability. Efforts are just getting underway to address the need for standard O&M procedures as PV gains a larger share of U.S. generation capacity. Due to the existing landscape of how and where PV is installed, including distributed generation from small and medium PV systems, as well as large, centralized utility-scale PV, O&M activities will require different levels of expertise and reporting, making standards even more important. This report summarizes recent efforts made by solar industry stakeholders to identify the existing standards and best practices applied to solar PV O&M activities, and determine the gaps that have yet to be, or are currently being addressed by industry.

14 SOLAR ENERGY↗

Optimizing Solar PV Deployment in Manufacturing: A Morphological Matrix and Fuzzy TOPSIS Approach

The growing energy demand of the industrial sector and the need for sustainable solutions highlight the importance of efficient decision making in solar photovoltaic (PV) implementation. Selecting optimal PV configuration is complex due to the interdependent technical, economic, environmental, and social factors involved. This study introduces an integrated decision-making method combining a morphological matrix and fuzzy TOPSIS to systematically select and rank optimal PV system configurations for manufacturing firms. While the morphological matrix exhaustively examines possible design solutions based on sensing, smart, sustainable, and social (S4) attributes, the fuzzy TOPSIS method ranks the alternatives by handling uncertainty in decision making. A case study conducted in a Mexican manufacturing company validates the methodology’s effectiveness. The optimal PV configuration identified comprehensively addresses operational and sustainability criteria, covering all lifecycle stages. This approach demonstrates quantitative superiority and greater robustness compared to existing fuzzy TOPSIS-based methods for solar PV applications. The findings highlight the practical value of data-driven, multi-criteria decision making for industrial solar energy adoption, enhancing project feasibility, cost efficiency, and environmental compliance. Future research will incorporate discrete event simulation (DES) to further refine energy consumption strategies in manufacturing.

Briceño, Citlaly Pérez↗

Trends in Installer Strategy and Customer Choice on a Solar PV Financing Platform

In this study, we explore how solar photovoltaic (PV) installer strategies have changed over time with respect to PV financing products and how these strategies affect PV customer choice. We use a novel data set from obtained from a software platform that connects installers to institutional investors and helps installers generate financed quotes. This data set enables us to explore the behaviors of small and mid-scale installers, whose market strategies have largely been unknown owing to lack of data. We find that the financing platform extends access to financing to small- and mid-scale installers, that installers have shifted toward power purchase agreements over time, that installers appear to modify strategies in reaction to various policy and market drivers, and that installers tend to 'lock in' to a specific strategy.

14 SOLAR ENERGY↗

The Effects of Market Concentration on Residential Solar PV Prices: Competition, Installer Scale, and Soft Costs

Competition among residential solar photovoltaic (PV) installers may reduce PV price markups and yield lower prices. At the same time, competition may reduce installer experience and opportunities for cost reductions through learning-by-doing and economies of scale. These dynamics suggest that PV non-hardware or 'soft' costs and installed prices depend on the distribution of market shares among installers, also known as market structure. This study leverages a rich data set of 226,769 residential PV systems to examine the relationship between market structure, soft costs, and PV prices. The results show that PV prices are lower, on average, in more concentrated markets, i.e., markets with fewer installers or where a subset of installers holds a large market share. The study provides evidence that this relationship is non-linear, such that prices are minimized in markets with an optimal balance of the benefits of market concentration and the benefits of competition.

14 SOLAR ENERGY↗

City and County Solar PV Training Program, Module 1: Goal Setting and Clarification

This module will help attendees understand nuances between different types of renewable energy goals, the importance of terminology when setting and announcing goals, the value of formally clarifying priorities, and how priorities may impact procurement options. It is the first training in a series intended to help municipal staff procure solar PV for their land and buildings.

100% renewable↗