Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Software errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Power Distribution Designing For Resilience Application (powdder)

Power Distribution Designing for Resilience Application (PowDDeR) is a software application to succinctly capture the capabilities of a power system to respond to disturbances, including natural or human (malicious or errors) caused disturbances. The software provides a measure of resilience for power systems.

McJunkin, TimothyR↗

2021 Radionuclide Air Emissions Report for Los Alamos National Laboratory, Revised October 2022

Provided is a revision to the Calendar Year 2021 Radionuclide Air Emissions Report for the Los Alamos National Laboratory (LANL). This report is a regulatory compliance deliverable for LANL under the Radionuclide NESHAP, 40 CFR 61 Subpart H. The revised report is needed to correct an error identified regarding generation of wind data files. These wind data files are used for plume modeling as part of calculating off-sites doses from monitored radionuclide air emissions sources. The error resulted from a software update by LANL’s meteorology team after new towers were added to the tower network. As a result of this error, incorrect wind frequencies were assigned to the different stability classes. This slightly affected the plume model calculations and subsequent off-site dose determinations for analyses using these wind files.

2021 Radionuclide, Air Emissions↗

SU-E-P-36: Evaluation of MLC Positioning Errors in Dynamic IMRT Treatments by Analyzing Dynalog Files

Purpose: To assess the accuracy of MLC positioning in Varian linear accelerator, in dynamic IMRT technique, from the analysis of dynalog files generated by the MLC controller. Methods: In Clinac accelerators (pre-TrueBeam technology), control system has an approximately 50ms delay (one control cycle time). Then, the system compares the measured position to the planned position corresponding to the next control cycle. As it has been confirmed by Varian technical support, this effect causes that measured positions appear in dynalogs one cycle out of phase with respect to the planned positions. Around 9000 dynalogs have been analyzed, coming from the three linear accelerators of our center (one Trilogy and two Clinac 21EX) equipped with a Millennium 120 MLC. In order to compare our results to recent publications, leaf positioning errors (RMS and 95th percentile) are calculated with and without delay effect. Dynalogs have been analyzed using a in-house Matlab software. Results: The RMS errors were 0.341, 0.339 and 0.348mm for each Linac; being the average error 0.343 mm. The 95th percentiles of the error were 0.617, 0.607 and 0.625; with an average of 0.617mm. A recent multi-institution study carried out by Kerns et al. found a mean leaf RMS error of 0.32mm and a 95th percentile error value of 0.64mm.Without delay effect, mean leaf RMS errors obtained were 0.040, 0.042 and 0.038mm for each treatment machine; being the average 0.040mm. The 95th percentile error values obtained were 0.057, 0.058 and 0.054 mm, with an average of 0.056mm. Conclusion: Results obtained for the mean leaf RMS error and the mean 95th percentile were consistent with the multi-institution study. Calculated error statistics with delay effect are significantly larger due to the speed proportional and systematic leaf offset. Consequently it is proposed to correct this effect in dynalogs analysis to determine the MLC performance.

60 APPLIED LIFE SCIENCES↗

SU-E-CAMPUS-J-05: Quantitative Investigation of Random and Systematic Uncertainties From Hardware and Software Components in the Frameless 6DBrainLAB ExacTrac System

Purpose: To evaluate setup accuracy and quantify individual systematic and random errors for the various hardware and software components of the frameless 6D-BrainLAB ExacTrac system. Methods: 35 patients with cranial lesions, some with multiple isocenters (50 total lesions treated in 1, 3, 5 fractions), were investigated. All patients were simulated with a rigid head-and-neck mask and the BrainLAB localizer. CT images were transferred to the IPLAN treatment planning system where optimized plans were generated using stereotactic reference frame based on the localizer. The patients were setup initially with infrared (IR) positioning ExacTrac system. Stereoscopic X-ray images (XC: X-ray Correction) were registered to their corresponding digitally-reconstructed-radiographs, based on bony anatomy matching, to calculate 6D-translational and rotational (Lateral, Longitudinal, Vertical, Pitch, Roll, Yaw) shifts. XC combines systematic errors of the mask, localizer, image registration, frame, and IR. If shifts were below tolerance (0.7 mm translational and 1 degree rotational), treatment was initiated; otherwise corrections were applied and additional X-rays were acquired to verify patient position (XV: X-ray Verification). Statistical analysis was used to extract systematic and random errors of the different components of the 6D-ExacTrac system and evaluate the cumulative setup accuracy. Results: Mask systematic errors (translational; rotational) were the largest and varied from one patient to another in the range (−15 to 4mm; −2.5 to 2.5degree) obtained from mean of XC for each patient. Setup uncertainty in IR positioning (0.97,2.47,1.62mm;0.65,0.84,0.96degree) was extracted from standard-deviation of XC. Combined systematic errors of the frame and localizer (0.32,−0.42,−1.21mm; −0.27,0.34,0.26degree) was extracted from mean of means of XC distributions. Final patient setup uncertainty was obtained from the standard deviations of XV (0.57,0.77,0.67mm,0.39,0.35,0.30degree). Conclusion: Statistical analysis was used to calculate cumulative and individual systematic errors from the different hardware and software components of the 6D-ExacTrac-system. Patients were treated with cumulative errors (<1mm,<1degree) with XV image guidance.

60 APPLIED LIFE SCIENCES↗

Polisher

Polisher is a software package designed to facilitate the error correction of an assembled genome using Illumia read data. The software addresses substandard regions by automatically correcting consensus errors and/or suggesting primer walking reactions to improve the quality of the bases.

Trong, S.↗

Managing scientific software complexity with Bocca and CCA

In high-performance scientific software development, the emphasis is often on short time to first solution. Even when the development of new components mostly reuses existing components or libraries and only small amounts of new code must be created, dealing with the component glue code and software build processes to obtain complete applications is still tedious and error-prone. Component-based software meant to reduce complexity at the application level increases complexity to the extent that the user must learn and remember the interfaces and conventions of the component model itself. To address these needs, we introduce Bocca, the first tool to enable application developers to perform rapid component prototyping while maintaining robust software-engineering practices suitable to HPC environments. Bocca provides project management and a comprehensive build environment for creating and managing applications composed of Common Component Architecture components. Of critical importance for high-performance computing (HPC) applications, Bocca is designed to operate in a language-agnostic way, simultaneously handling components written in any of the languages commonly used in scientific applications: C, C++, Fortran, Python and Java. Bocca automates the tasks related to the component glue code, freeing the user to focus on the scientific aspects of the application. Bocca embraces the philosophy pioneered by Ruby on Rails for web applications: start with something that works, and evolve it to the user's purpose.

99 GENERAL AND MISCELLANEOUS↗

Software Verification Toolkit (SVT): Survey on Available Software Verification Tools and Future Direction

Writing software is difficult. However, writing complex, well tested and designed, and functionally correct software is incredibly difficult. An entire field of study is devoted to the validation and verification of software to address this problem, and in this paper we analyze the landscape of currently available third party software. We have divided our analyses into three separate subsections with regards to software validation: formal methods, static analysis, and test generation. Formal verification is the most complex method in which to validate software correctness, but also the most thorough as it truly validates the mathematical validity of the source code. Static analysis generally is relegated to abstract syntax tree traversal techniques to find errors related to faulty software such as memory leaks or stack overflow issues. Automatic test generation is similar in implementation to static analysis, but pushes a bit further in verifying the boundedness of function inputs and outputs with regards to annotated or parsed criteria. The crux of this report is to analyze and describe the software tools that implement these techniques to validate and verify software. Pros and cons related to installation, utilization, and capabilities of the frameworks are described, and reproducible examples are provided with a focus on usability. The initial survey concluded that the most interesting tools of note are Z3, Isabelle/HOL, and TLA+ with regards to formal verification; and Infer, Frama-C, and SonarQube with regards to static analysis. With these tools in mind, a final conjecture is provided that describes future avenues of utilizing these tools for developing a verification framework to assist in validating existing software at Sandia National Laboratories.

97 MATHEMATICS AND COMPUTING↗

Interfraction rotation of the prostate as evaluated by kilovoltage X-ray fiducial marker imaging in intensity-modulated radiotherapy of localized prostate cancer

To quantify the daily rotation of the prostate during a radiotherapy course using stereoscopic kilovoltage (kV) x-ray imaging and intraprostatic fiducials for localization and positioning correction. From 2005 to 2009, radio-opaque fiducial markers were inserted into 38 patients via perineum into the prostate. The ExacTrac/Novalis Body X-ray 6-day image acquisition system (ET/NB; BrainLab AG, Feldkirchen, Germany) was used to determine and correct the target position. During the first period in 10 patients we recorded all rotation errors but used only Y (table) for correction. For the next 28 patients we used for correction all rotational coordinates, i.e., in addition Z (superior-inferior [SI] or roll) and X (left-right [LR] or tilt/pitch) according to the fiducial marker position by use of the Robotic Tilt Module and Varian Exact Couch. Rotation correction was applied above a threshold of 1 Degree-Sign displacement. The systematic and random errors were specified. Overall, 993 software-assisted rotational corrections were performed. The interfraction rotation errors of the prostate as assessed from the radiodense surrogate markers around the three axes Y, Z, and X were on average 0.09, -0.52, and -0.01 Degree-Sign with standard deviations of 2.01, 2.30, and 3.95 Degree-Sign , respectively. The systematic uncertainty per patient for prostate rotation was estimated with 2.30, 1.56, and 4.13 Degree-Sign and the mean random components with 1.81, 2.02, and 3.09 Degree-Sign . The largest rotational errors occurred around the X-axis (pitch), but without preferring a certain orientation. Although the error around Z (roll) can be compensated on average by a transformation with 4 coordinates, a significant error around X remains and advocates the full correction with 6 coordinates. Rotational errors as assessed via daily stereoscopic online imaging are significant and dominate around X. Rotation possibly degrades the dosimetric coverage of the target volume and may require suitable strategies for correction.

61 RADIATION PROTECTION AND DOSIMETRY↗

Accuracy of Thermodynamic Databases for Hydroxyapatite Dissolution Constant

We report that discrepancies have been noted in the solubility constant values of calcium phosphate minerals between various databases employed in widely-used aqueous speciation calculation software programs. This can cause serious errors in the calculated speciation of waters using these software programs. The aim of the present communication was to bring to light these discrepancies. Experimental determinations of the hydroxyapatite solubility product vary by as much as ten orders of magnitude as a result of experimental challenges related to the presence of impurities in the hydroxyapatite used, incongruent dissolution and the contamination of solutions with dissolved carbon dioxide. Finally, it is suggested that the value used in the database Thermo.dat is consistent with experimental data devoid of common experimental problems, while other common databases use values that lead to a vastly overestimated solubility of hydroxyapatite.

58 GEOSCIENCES↗

GSIMF : a web service based software and database management system for the generation grids.

To process the vast amount of data from high energy physics experiments, physicists rely on Computational and Data Grids; yet, the distribution, installation, and updating of a myriad of different versions of different programs over the Grid environment is complicated, time-consuming, and error-prone. Our Grid Software Installation Management Framework (GSIMF) is a set of Grid Services that has been developed for managing versioned and interdependent software applications and file-based databases over the Grid infrastructure. This set of Grid services provide a mechanism to install software packages on distributed Grid computing elements, thus automating the software and database installation management process on behalf of the users. This enables users to remotely install programs and tap into the computing power provided by Grids.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-789: Validation of 3DVH Accuracy On Quantifying Delivery Errors Based On Clinical Relevant DVH Metrics

Purpose: Detection of treatment delivery errors is important in radiation therapy. However, accurate quantification of delivery errors is also of great importance. This study aims to evaluate the 3DVH software’s ability to accurately quantify delivery errors. Methods: Three VMAT plans (prostate, H&N and brain) were randomly chosen for this study. First, we evaluated whether delivery errors could be detected by gamma evaluation. Conventional per-beam IMRT QA was performed with the ArcCHECK diode detector for the original plans and for the following modified plans: (1) induced dose difference error up to ±4.0% and (2) control point (CP) deletion (3 to 10 CPs were deleted) (3) gantry angle shift error (3 degree uniformly shift). 2D and 3D gamma evaluation were performed for all plans through SNC Patient and 3DVH, respectively. Subsequently, we investigated the accuracy of 3DVH analysis for all cases. This part evaluated, using the Eclipse TPS plans as standard, whether 3DVH accurately can model the changes in clinically relevant metrics caused by the delivery errors. Results: 2D evaluation seemed to be more sensitive to delivery errors. The average differences between ECLIPSE predicted and 3DVH results for each pair of specific DVH constraints were within 2% for all three types of error-induced treatment plans, illustrating the fact that 3DVH is fairly accurate in quantifying the delivery errors. Another interesting observation was that even though the gamma pass rates for the error plans are high, the DVHs showed significant differences between original plan and error-induced plans in both Eclipse and 3DVH analysis. Conclusion: The 3DVH software is shown to accurately quantify the error in delivered dose based on clinically relevant DVH metrics, where a conventional gamma based pre-treatment QA might not necessarily detect.

60 APPLIED LIFE SCIENCES↗

Results of a Multi-Institutional Benchmark Test for Cranial CT/MR Image Registration

Purpose: Variability in computed tomography/magnetic resonance imaging (CT/MR) cranial image registration was assessed using a benchmark case developed by the Quality Assurance Review Center to credential institutions for participation in Children's Oncology Group Protocol ACNS0221 for treatment of pediatric low-grade glioma. Methods and Materials: Two DICOM image sets, an MR and a CT of the same patient, were provided to each institution. A small target in the posterior occipital lobe was readily visible on two slices of the MR scan and not visible on the CT scan. Each institution registered the two scans using whatever software system and method it ordinarily uses for such a case. The target volume was then contoured on the two MR slices, and the coordinates of the center of the corresponding target in the CT coordinate system were reported. The average of all submissions was used to determine the true center of the target. Results: Results are reported from 51 submissions representing 45 institutions and 11 software systems. The average error in the position of the center of the target was 1.8 mm (1 standard deviation = 2.2 mm). The least variation in position was in the lateral direction. Manual registration gave significantly better results than did automatic registration (p = 0.02). Conclusion: When MR and CT scans of the head are registered with currently available software, there is inherent uncertainty of approximately 2 mm (1 standard deviation), which should be considered when defining planning target volumes and PRVs for organs at risk on registered image sets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comprehensive Automated Welder System

The Comprehensive Automated Welder System - PDRD SR-17-007 project was initiated to develop hardware and software to eliminate possible error pre-cursor functions of the pinch welding process that require manual manipulation and data entry as well as leveraging 21st century technology advances by replacing obsolete hardware with state of the art maintainable equipment. The project plan targeted three primary areas for improvement: 1. Replacing the existing welding power supply system with a solid-state power supply, 2. Improving the data acquisition system, sensors and controls, and 3. Updating the software to a FPGA “real-time” program with automated steps. SRNL purchased, designed and installed in 723-A, a system to meet the requirements for these areas. While improvements in hardware controls and sensor selection were achieved and a successful software automation routine was demonstrated, the performance goals were not met with the custom solid-state power transformer.

42 ENGINEERING↗

SU-E-P-43: A Knowledge Based Approach to Guidelines for Software Safety

Purpose: In the fall of 2012, a survey was distributed to medical physicists across Canada. The survey asked the respondents to comment on various aspects of software development and use in their clinic. The survey revealed that most centers employ locally produced (in-house) software of some kind. The respondents also indicated an interest in having software guidelines, but cautioned that the realities of cancer clinics include variations, that preclude a simple solution. Traditional guidelines typically involve periodically repeating a set of prescribed tests with defined tolerance limits. However, applying a similar formula to software is problematic since it assumes that the users have a perfect knowledge of how and when to apply the software and that if the software operates correctly under one set of conditions it will operate correctly under all conditions Methods: In the approach presented here the personnel involved with the software are included as an integral part of the system. Activities performed to improve the safety of the software are done with both software and people in mind. A learning oriented approach is taken, following the premise that the best approach to safety is increasing the understanding of those associated with the use or development of the software. Results: The software guidance document is organized by areas of knowledge related to use and development of software. The categories include: knowledge of the underlying algorithm and its limitations; knowledge of the operation of the software, such as input values, parameters, error messages, and interpretation of output; and knowledge of the environment for the software including both data and users. Conclusion: We propose a new approach to developing guidelines which is based on acquiring knowledge-rather than performing tests. The ultimate goal is to provide robust software guidelines which will be practical and effective.

60 APPLIED LIFE SCIENCES↗

Characterizing the AB Doradus moving group via high-resolution spectroscopy and kinematic traceback

We present a detailed analysis of 10 proposed F and G members of the nearby, young moving group AB Doradus (ABD). Our sample was obtained using the 2.7 m telescope at the McDonald Observatory with the coude echelle spectrograph, achieving R ∼ 60,000 and signal-to-noise ratio ∼200. We derive spectroscopic T {sub eff}, log(g), [Fe/H], and microturbulance (v{sub t} ) using a bootstrap method of the TGVIT software resulting in typical errors of 33K in T {sub eff}, 0.08 dex in log(g), 0.03 dex in [Fe/H], and 0.13 km s{sup –1} in v{sub t} . Characterization of the ABD sample is performed in three ways: (1) chemical homogeneity, (2) kinematic traceback, and (3) isochrone fitting. We find the average metal abundance is [M/H] = –0.03 ± 0.06 with a traceback age of 125 Myr. Our stars were fit to three different evolutionary models and we found that the best match to our ABD sample is the YREC [M/H] = –0.1 model. In our sample of 10 stars, we identify 1 star that is a probable non-member, 3 enigmatic stars, and 6 stars with confirmed membership. We also present a list of chemically coherent stars from this study and the Barenfeld et al. study.

79 ASTRONOMY AND ASTROPHYSICS↗

FPDetect: Efficient Reasoning About Stencil Programs Using Selective Direct Evaluation

We present FPDetect, a low-overhead approach for detecting logical errors and soft errors affecting stencil computations without generating false positives. We develop an offline analysis that tightly estimates the number of floating-point bits preserved across stencil applications. This estimate rigorously bounds the values expected in the data space of the computation. Violations of this bound can be attributed with certainty to errors. FPDetect helps synthesize error detectors customized for user-specified levels of accuracy and coverage. FPDetect also enables overhead reduction techniques based on deploying these detectors coarsely in space and time. Experimental evaluations demonstrate the practicality of our approach.

97 MATHEMATICS AND COMPUTING↗