Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Small object detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A SEARCH FOR RAPIDLY ACCRETING WHITE DWARFS IN THE SMALL MAGELLANIC CLOUD

The nature of the progenitors of Type Ia supernovae (SNe Ia) is still a mystery. While plausible candidates are known for both the single-degenerate and double-degenerate models, the observed numbers fall significantly short of what is required to reproduce the SNe Ia rate. Some of the most promising single-degenerate Type Ia progenitors are recurrent novae and super-soft sources (SSS). White dwarfs (WDs) with higher mass transfer rates can also be SN Ia progenitors. For these rapidly accreting white dwarfs (RAWDs), more material than is needed for steady burning accretes on the WD, and extends the WD's photosphere. Unlike SSS, such objects will likely not be detectable at soft X-ray energies, but will be bright at longer wavelengths, such as the far-ultraviolet (UV). Possible examples include LMC N66 and the V Sagittae stars. We present a survey using multi-object spectrographs looking for RAWDs in the central core of the Small Magellanic Cloud (SMC), from objects selected to be bright in the far-UV and with blue far UV - V colors. While we find some unusual objects, and recover known planetary nebula and Wolf-Rayet (WR) stars, we detect no candidate RAWD. The upper limits from this non-detection depend on our expectations of what an RAWD should look like, as well assumptions about the internal extinction of the SMC. Assuming they resemble LMC N66 or fainter versions of WR stars we set an upper limit of 10-14 RAWDs in the SMC. However, our survey is unlikely to detect objects like V Sge, and hence we cannot set meaningful upper limits if RAWDs generally resemble V Sge.

79 ASTRONOMY AND ASTROPHYSICS↗

THE SURFACE COMPOSITION OF LARGE KUIPER BELT OBJECT 2007 OR10

We present photometry and spectra of the large Kuiper belt object 2007 OR10. The data show significant near-infrared absorption features due to water ice. While most objects in the Kuiper belt with water ice absorption this prominent have the optically neutral colors of water ice, 2007 OR10 is among the reddest Kuiper belt objects known. One other large Kuiper belt object-Quaoar-has similar red coloring and water ice absorption, and it is hypothesized that the red coloration of this object is due to irradiation of the small amounts of methane able to be retained on Quaoar. 2007 OR10, though warmer than Quaoar, is in a similar volatile retention regime because it is sufficiently larger that its stronger gravity can still retain methane. We propose, therefore, that the red coloration on 2007 OR10 is also caused by the retention of small amounts of methane. Positive detection of methane on 2007 OR10 will require spectra with higher signal to noise. Models for volatile retention on Kuiper belt objects appear to continue to do an excellent job reproducing all of the available observations.

79 ASTRONOMY AND ASTROPHYSICS↗

DRoP: Automated detection of conserved solvent‐binding sites on proteins

Abstract Water and ligand binding play critical roles in the structure and function of proteins, yet their binding sites and significance are difficult to predict a priori. Multiple solvent crystal structures (MSCS) is a method where several X‐ray crystal structures are solved, each in a unique solvent environment, with organic molecules that serve as probes of the protein surface for sites evolved to bind ligands, while the first hydration shell is essentially maintained. When superimposed, these structures contain a vast amount of information regarding hot spots of protein‐protein or protein‐ligand interactions, as well as conserved water‐binding sites retained with the change in solvent properties. Optimized mining of this information requires reliable structural data and a consistent, objective analysis tool. Detection of related solvent positions (DRoP) was developed to automatically organize and rank the water or small organic molecule binding sites within a given set of structures. It is a flexible tool that can also be used in conserved water analysis given multiple structures of any protein independent of the MSCS method. The DRoP output is an HTML format list of the solvent sites ordered by conservation rank in its population within the set of structures, along with renumbered and recolored PDB files for visualization and facile analysis. Here, we present a previously unpublished set of MSCS structures of bovine pancreatic ribonuclease A (RNase A) and use it together with published structures to illustrate the capabilities of DRoP.

Kearney, Bradley M.↗

WE-H-206-00: Advances in Preclinical Imaging

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

WE-H-206-01: Photoacoustic Tomography: Multiscale Imaging From Organelles to Patients by Ultrasonically Beating the Optical Diffusion Limit

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

WE-H-206-02: Recent Advances in Multi-Modality Molecular Imaging of Small Animals

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

WE-H-206-03: Promises and Challenges of Benchtop X-Ray Fluorescence CT (XFCT) for Quantitative in Vivo Imaging

Lihong V. Wang: Photoacoustic tomography (PAT), combining non-ionizing optical and ultrasonic waves via the photoacoustic effect, provides in vivo multiscale functional, metabolic, and molecular imaging. Broad applications include imaging of the breast, brain, skin, esophagus, colon, vascular system, and lymphatic system in humans or animals. Light offers rich contrast but does not penetrate biological tissue in straight paths as x-rays do. Consequently, high-resolution pure optical imaging (e.g., confocal microscopy, two-photon microscopy, and optical coherence tomography) is limited to penetration within the optical diffusion limit (∼1 mm in the skin). Ultrasonic imaging, on the contrary, provides fine spatial resolution but suffers from both poor contrast in early-stage tumors and strong speckle artifacts. In PAT, pulsed laser light penetrates tissue and generates a small but rapid temperature rise, which induces emission of ultrasonic waves due to thermoelastic expansion. The ultrasonic waves, orders of magnitude less scattering than optical waves, are then detected to form high-resolution images of optical absorption at depths up to 7 cm, conquering the optical diffusion limit. PAT is the only modality capable of imaging across the length scales of organelles, cells, tissues, and organs (up to whole-body small animals) with consistent contrast. This rapidly growing technology promises to enable multiscale biological research and accelerate translation from microscopic laboratory discoveries to macroscopic clinical practice. PAT may also hold the key to label-free early detection of cancer by in vivo quantification of hypermetabolism, the quintessential hallmark of malignancy. Learning Objectives: To understand the contrast mechanism of PAT To understand the multiscale applications of PAT Benjamin M. W. Tsui: Multi-modality molecular imaging instrumentation and techniques have been major developments in small animal imaging that has contributed significantly to biomedical research during the past decade. The initial development was an extension of clinical PET/CT and SPECT/CT from human to small animals and combine the unique functional information obtained from PET and SPECT with anatomical information provided by the CT in registered multi-modality images. The requirements to image a mouse whose size is an order of magnitude smaller than that of a human have spurred advances in new radiation detector technologies, novel imaging system designs and special image reconstruction and processing techniques. Examples are new detector materials and designs with high intrinsic resolution, multi-pinhole (MPH) collimator design for much improved resolution and detection efficiency compared to the conventional collimator designs in SPECT, 3D high-resolution and artifact-free MPH and sparse-view image reconstruction techniques, and iterative image reconstruction methods with system response modeling for resolution recovery and image noise reduction for much improved image quality. The spatial resolution of PET and SPECT has improved from ∼6–12 mm to ∼1 mm a few years ago to sub-millimeter today. A recent commercial small animal SPECT system has achieved a resolution of ∼0.25 mm which surpasses that of a state-of-art PET system whose resolution is limited by the positron range. More recently, multimodality SA PET/MRI and SPECT/MRI systems have been developed in research laboratories. Also, multi-modality SA imaging systems that include other imaging modalities such as optical and ultrasound are being actively pursued. In this presentation, we will provide a review of the development, recent advances and future outlook of multi-modality molecular imaging of small animals. Learning Objectives: To learn about the two major multi-modality molecular imaging techniques of small animals. To learn about the spatial resolution achievable by the molecular imaging systems for small animal today. To learn about the new multi-modality imaging instrumentation and techniques that are being developed. Sang Hyun Cho; X-ray fluorescence (XRF) imaging, such as x-ray fluorescence computed tomography (XFCT), offers unique capabilities for accurate identification and quantification of metals within the imaging objects. As a result, it has emerged as a promising quantitative imaging modality in recent years, especially in conjunction with metal-based imaging probes. This talk will familiarize the audience with the basic principles of XRF/XFCT imaging. It will also cover the latest development of benchtop XFCT technology. Additionally, the use of metallic nanoparticles such as gold nanoparticles, in conjunction with benchtop XFCT, will be discussed within the context of preclinical multimodal multiplexed molecular imaging. Learning Objectives: To learn the basic principles of XRF/XFCT imaging To learn the latest advances in benchtop XFCT development for preclinical imaging Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; L. Wang, Funding Support: NIH; COI: Microphotoacoustics; S. Cho, Yes: ;NIH/NCI grant R01CA155446 DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

Orbital Motion of the Wide Planetary-mass Companion GSC 6214-210 b: No Evidence for Dynamical Scattering

Direct-imaging exoplanet surveys have discovered a class of 5–20 M{sub Jup} substellar companions at separations >100 au from their host stars, which present a challenge to planet and star formation models. Detailed analysis of the orbital architecture of these systems can provide constraints on possible formation mechanisms, including the possibility that they were dynamically ejected onto a wide orbit. We present astrometry for the wide planetary-mass companion GSC 6214-210 b (240 au; ≈14 M{sub Jup}) obtained using NIRC2 with adaptive optics at the Keck telescope over 10 years. Our measurements achieved astrometric uncertainties of ≈1 mas per epoch. We determined a relative motion of 1.12 ± 0.15 mas yr{sup −1} (0.61 ± 0.09 km s{sup −1}), the first detection of orbital motion for this companion. We compute the minimum periastron for the companion due to our measured velocity vector and derive constraints on the orbital parameters through our modified implementation of the Orbits for the Impatient rejection sampling algorithm. We find that close periastron orbits, which could indicate that the companion was dynamically scattered, are present in our posterior but have low likelihoods. For all orbits in our posterior, we assess the detectability of close-in companions that could have scattered GSC 6214-210 b from a closer orbit, and find that most potential scatterers would have been detected in previous imaging. We conclude that formation at small orbital separation and subsequent dynamical scattering through interaction with another potential close-in object is an unlikely formation pathway for this companion. We also update stellar and substellar properties for the system using the new parallax from Gaia DR2.

79 ASTRONOMY AND ASTROPHYSICS↗

SEARCHING FOR GAS GIANT PLANETS ON SOLAR SYSTEM SCALES: VLT NACO/APP OBSERVATIONS OF THE DEBRIS DISK HOST STARS HD172555 AND HD115892

Using the Apodizing Phase Plate (APP) coronagraph of Very Large Telescope/NACO we searched for planetary mass companions around HD115892 and HD172555 in the thermal infrared at 4 {mu}m. Both objects harbor unusually luminous debris disks for their age and it has been suggested that small dust grains were produced recently in transient events (e.g., a collision) in these systems. Such a collision of planetesimals or protoplanets could have been dynamically triggered by yet unseen companions. We did not detect any companions in our images but derived the following detection limits: for both objects we would have detected companions with apparent magnitudes between {approx}13.2 and 14.1 mag at angular separations between 0.''4 and 1.''0 at the 5{sigma} level. For HD115892 we were sensitive to companions with 12.1 mag even at 0.''3. Using theoretical models these magnitudes are converted into mass limits. For HD115892 we would have detected objects with 10-15 M{sub Jup} at angular separations between 0.''4 and 1.''0 (7-18 AU). At 0.''3 ({approx}5.5 AU) the detection limit was {approx}>25 M{sub Jup}. For HD172555 we reached detection limits between 2 and 3 M{sub Jup} at separations between 0.''5 and 1.''0 (15-29 AU). At 0.''4 ({approx}11 AU) the detection limit was {approx}>4 M{sub Jup}. Despite the non-detections, our data demonstrate the unprecedented contrast performance of NACO/APP in the thermal infrared at very small inner working angles and we show that our observations are mostly background limited at separations {approx}>0.''5.

79 ASTRONOMY AND ASTROPHYSICS↗

Hubble space telescope high-resolution imaging of Kepler small and cool exoplanet host stars

High-resolution imaging is an important tool for follow-up study of exoplanet candidates found via transit detection with the Kepler mission. We discuss here Hubble Space Telescope imaging with the WFC3 of 23 stars that host particularly interesting Kepler planet candidates based on their small size and cool equilibrium temperature estimates. Results include detections, exclusion of background stars that could be a source of false positives for the transits, and detection of physically associated companions in a number of cases providing dilution measures necessary for planet parameter refinement. For six Kepler objects of interest, we find that there is ambiguity regarding which star hosts the transiting planet(s), with potentially strong implications for planetary characteristics. Our sample is evenly distributed in G, K, and M spectral types. Albeit with a small sample size, we find that physically associated binaries are more common than expected at each spectral type, reaching a factor of 10 frequency excess in M. We document the program detection sensitivities, detections, and deliverables to the Kepler follow-up program archive.

79 ASTRONOMY AND ASTROPHYSICS↗

CATALOG MATCHING WITH ASTROMETRIC CORRECTION AND ITS APPLICATION TO THE HUBBLE LEGACY ARCHIVE

Object cross-identification in multiple observations is often complicated by the uncertainties in their astrometric calibration. Due to the lack of standard reference objects, an image with a small field of view can have significantly larger errors in its absolute positioning than the relative precision of the detected sources within. We present a new general solution for the relative astrometry that quickly refines the World Coordinate System of overlapping fields. The efficiency is obtained through the use of infinitesimal three-dimensional rotations on the celestial sphere, which do not involve trigonometric functions. They also enable an analytic solution to an important step in making the astrometric corrections. In cases with many overlapping images, the correct identification of detections that match together across different images is difficult to determine. We describe a new greedy Bayesian approach for selecting the best object matches across a large number of overlapping images. The methods are developed and demonstrated on the Hubble Legacy Archive, one of the most challenging data sets today. We describe a novel catalog compiled from many Hubble Space Telescope observations, where the detections are combined into a searchable collection of matches that link the individual detections. The matches provide descriptions of astronomical objects involving multiple wavelengths and epochs. High relative positional accuracy of objects is achieved across the Hubble images, often sub-pixel precision in the order of just a few milliarcseconds. The result is a reliable set of high-quality associations that are publicly available online.

79 ASTRONOMY AND ASTROPHYSICS↗

Origin of 1I/’Oumuamua. II. An Ejected Exo-Oort Cloud Object?

1I/’Oumuamua is the first detected interstellar interloper. We test the hypothesis that it is representative of a background population of exo-Oort cloud objects ejected under the effect of post-main sequence mass loss and stellar encounters. We do this by comparing the cumulative number density of interstellar objects inferred from the detection of 1I/’Oumuamua to that expected from these two clearing processes. We consider the 0.08–8 M {sub ⊙} mass range, take into account the dependencies with stellar mass, Galactocentric distance, and evolutionary state, and consider a wide range of size distributions for the ejected objects. Our conclusion is that 1I/’Oumuamua is likely not representative of this background population, even though there are large uncertainties in the masses and size distributions of the exo-Oort Clouds. We discuss whether the number density of free-floating, planetary-mass objects derived from gravitational microlensing surveys could be used as a discriminating measurement regarding 1I/’Oumuamua’s origin (given their potential common origin). We conclude that this is challenged by the mass limitation of the surveys and the resulting uncertainty of the mass distribution of the free floaters. The detection of interlopers may be one of the few observational constraints of the small end of this population, with the caveat that, as we conclude here and in Moro-Martín (2018), in the case of 1I/’Oumuamua, it might not be appropriate to assume this object is representative of an isotropic background population, which makes the derivation of a number density very challenging.

79 ASTRONOMY AND ASTROPHYSICS↗

The population of tiny near-Earth objects observed by NEOWISE

Only a very small fraction of the asteroid population at size scales comparable to the object that exploded over Chelyabinsk, Russia has been discovered to date, and physical properties are poorly characterized. We present previously unreported detections of 105 close approaching near-Earth objects (NEOs) by the Wide-field Infrared Survey Explorer (WISE) mission's NEOWISE project. These infrared observations constrain physical properties such as diameter and albedo for these objects, many of which are found to be smaller than 100 m. Because these objects are intrinsically faint, they were detected by WISE during very close approaches to the Earth, often at large apparent on-sky velocities. We observe a trend of increasing albedo with decreasing size, but as this sample of NEOs was discovered by visible light surveys, it is likely that selection biases against finding small, dark NEOs influence this finding.

79 ASTRONOMY AND ASTROPHYSICS↗

Yarkovsky Drift Detections for 247 Near-Earth Asteroids

The Yarkovsky effect is a thermal process acting upon the orbits of small celestial bodies, which can cause these orbits to slowly expand or contract with time. The effect is subtle (〈da/dt〉∼10{sup −4} au My{sup −1} for a 1 km diameter object) and is thus generally difficult to measure. We analyzed both optical and radar astrometry for 600 Near-Earth Asteroids (NEAs) for the purpose of detecting and quantifying the Yarkovsky effect. We present 247 NEAs with measured drift rates, which is the largest published set of Yarkovsky detections. This large sample size provides an opportunity to examine the Yarkovsky effect in a statistical manner. In particular, we describe two independent population-based tests that verify the measurement of Yarkovsky orbital drift. First, we provide observational confirmation for the Yarkovsky effect’s theoretical size dependence of 1/D, where D is diameter. Second, we find that the observed ratio of negative to positive drift rates in our sample is 2.34, which, accounting for bias and sampling uncertainty, implies an actual ratio of 2.7{sub −0.7}{sup +0.3}. This ratio has a vanishingly small probability of occurring due to chance or statistical noise. The observed ratio of retrograde to prograde rotators is two times lower than the ratio expected from numerical predictions from NEA population studies and traditional assumptions about the sense of rotation of NEAs originating from various main belt escape routes. We also examine the efficiency with which solar energy is converted into orbital energy and find a median efficiency in our sample of 12%. We interpret this efficiency in terms of NEA spin and thermal properties.

79 ASTRONOMY AND ASTROPHYSICS↗

A Comparative Observational Study of YSO Classification in Four Small Star-forming H ii Regions

We have developed a new young stellar object (YSO) identification and classification technique using mid-infrared Wide-field Infrared Survey Explorer (WISE) data. We compare this new technique with previous WISE YSO detection and classification methods that used either infrared colors or spectral energy distribution slopes. In this study, we also use the new technique to detect and examine the YSO population associated with four small H ii regions: KR 7, KR 81, KR 120, and KR 140. The relatively simple structure of these regions allows us to effectively use both spatial and temporal constraints to identify YSOs that are potential products of triggered star formation. We are also able to identify regions of active star formation around these H ii regions that are clearly not influenced by the H ii region expansion, and thus demonstrate that star formation is on-going on megayear timescales in some of these molecular clouds.

79 ASTRONOMY AND ASTROPHYSICS↗

High Fidelity Digital Twins for BWRX-300 Critical Systems

This project developed and demonstrated digital-twin technology for advanced nuclear systems under the ARPA-E GEMINA program, with a focus on the BWRX-300 small modular reactor. The primary objective was to reduce operation and maintenance (O&M) costs through predictive health monitoring and model-based fault detection. The project combined MIT’s high-fidelity physics models and machine-learning and digital-twin algorithms, and GE Hitachi’s digital-twin algorithms and operational expertise to build physics-based digital twins capable of real-time system monitoring and maintenance scheduling.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

PRELIMINARY RESULTS FROM NEOWISE: AN ENHANCEMENT TO THE WIDE-FIELD INFRARED SURVEY EXPLORER FOR SOLAR SYSTEM SCIENCE

The Wide-field Infrared Survey Explorer (WISE) has surveyed the entire sky at four infrared wavelengths with greatly improved sensitivity and spatial resolution compared to its predecessors, the Infrared Astronomical Satellite and the Cosmic Background Explorer. NASA's Planetary Science Division has funded an enhancement to the WISE data processing system called 'NEOWISE' that allows detection and archiving of moving objects found in the WISE data. NEOWISE has mined the WISE images for a wide array of small bodies in our solar system, including near-Earth objects (NEOs), Main Belt asteroids, comets, Trojans, and Centaurs. By the end of survey operations in 2011 February, NEOWISE identified over 157,000 asteroids, including more than 500 NEOs and {approx}120 comets. The NEOWISE data set will enable a panoply of new scientific investigations.

79 ASTRONOMY AND ASTROPHYSICS↗

OGLE atlas of classical novae. I. Galactic bulge objects

Eruptions of classical novae are possible sources of lithium formation and gamma-ray emission. Nova remnants can also become Type Ia supernovae (SNe Ia). The contribution of novae to these phenomena depends on nova rates, which are not well established for the Galaxy. Here, we directly measure a Galactic bulge nova rate of 13.8 ± 2.6 yr{sup −1}. This measurement is much more accurate than any previous measurement of this kind thanks to many years’ monitoring of the bulge by the Optical Gravitational Lensing Experiment (OGLE) survey. Our sample consists of 39 novae eruptions, ∼1/3 of which are OGLE-based discoveries. This long-term monitoring allows us to not only measure the nova rate but also to study in detail the light curves of 39 eruptions and more than 80 post-nova candidates. We measured orbital periods for 9 post-novae and 9 novae, and in 14 cases we procured the first estimates. The OGLE survey is very sensitive to the frequently erupting recurrent novae. We did not find any object similar to M31 2008-12a, which erupts once a year. The lack of detection indicates that there is only a small number of them in the Galactic bulge.

79 ASTRONOMY AND ASTROPHYSICS↗