Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sizing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Design of a Particle Shadow-graph Velocimetry and Size (PSVS) System to Determine Particle Size and Density Distributions in Hanford Nuclear Tank Wastes - 12280

Accurate particle size and density distributions for nuclear tank waste materials are essential information that helps determine the engineering requirements for a host of waste management unit operations (e.g., tank mixing, pipeline transport, and filtration). The most prevalent approach for determining particle size and density distribution is highly laborious and involves identifying individual particles using scanning electron microscope/x-ray diffraction and then acquiring the density of the materials from the technical literature. Other methods simply approximate individual particle densities by assuming chemical composition, rather than obtaining actual measurements of particle density. To overcome these limitations, a Particle Shadow-graph Velocimetry and Size (PSVS) system has been designed to simultaneously obtain particle size and density distributions for a broad range of Hanford tank waste materials existing as both individual particles and agglomerates. The PSVS system uses optical hardware, a temperature-controlled settling column, and particle introduction chamber to accurately and reproducibly obtain images of settling particles. Image analysis software provides a highly accurate determination of both particle terminal velocity and equivalent spherical particle diameter. The particle density is then calculated from Newton's terminal settling theory. The PSVS system was designed to accurately image particle/agglomerate sizes between 10 and 1000 μm and particle/agglomerate densities ranging from 1.4 to 11.5 g/cm{sup 3}, where the maximum terminal velocity does not exceed 10 cm/s. Preliminary testing was completed with standard materials and results were in good agreement with terminal settling theory. Recent results of this method development are presented, as well as experimental design. The primary goal of these PSVS system tests was to obtain accurate and reproducible particle size and velocity measurements to estimate particle densities within 20 percent of direct measured density values. The average percent error observed in particle densities was 4.8, 8.2, and 25.8 percent for S1D3 (high-density soda-lime glass), S3D4 (zirconia), and S1D2 (soda-lime glass) beads, respectively. The maximum measured particle density error observed was 14.5, 21.0, and 58.4, for S1D3, S3D4, and S1D2 beads, respectively. Multiple sources of error can exist that contribute to inaccurate estimates of particle density using the PSVS approach. Two significant influences observed were thermal convective currents in the settling column fluid and non-spherical (irregular) particle shapes in the standard test materials. Experimental results using buoyant beads suggest thermal convective currents can influence the movement of settling particles as much as 4 mm/s. These thermal convective currents are clearly a significant concern for smaller and less-dense particles/agglomerates which have terminal velocities of the same magnitude. Significant effort went into the design and fabrication of a thermal control system for the PSVS settling column. However, small temperature variations (<0.3 deg. C) are difficult to prevent and measure accurately. Therefore, although designing the thermal control system was necessary, it is not considered the only solution to minimize error due to thermal convective currents. The use of small diameter (10 to 27 μm) polyethylene buoyant beads (in low concentrations) during actual settling experiments may be necessary to provide insight into particle-particle interactions and fluid velocity correction factors to account for potential influences from thermal convective currents. Future testing will incorporate the buoyant beads into the analysis technique when the suspension fluid is chemically compatible. The use of the Newton's law to calculate particle/agglomerate densities assumes spherical particle shapes. As the actual particle/agglomerates diverge from spherical, the margin of error increases. The selection of high quality (in density and shape) monodispersed particle standards was a direct attempt to reduce the uncertainties associated with non-spherical or irregular particles and to only observe the PSVS method and analysis error. While investigating the source of data scatter for the S1D3 bead (nominal 700 μm) standard, significant irregular particles where discovered. Yet, a subsequent investigation into the S3D4 bead standard was also conducted and it was determined that 60 percent of the particles had a 0.9 to 0.8 centricity, 32 percent were between 0.8 and 0.7, only 7 percent were between 1.0 and 0.9, and the remaining 1 percent of the particles had centricities between 0.7 and 0.6. Contrast this with the S1D3 bead standard, where 100 percent of particles had centricities between 0.95 and 0.98, upon applying the centricity filter. The influence of the non-spherical shape of the S3D4 bead standard is evident when comparing a 3.9 percent average density error for S1D3 glass bead standard with an 8.3 percent average density error for the S3D4 bead standard. Model corrections for non-spherical shape must be implemented to account for these measurement errors during future method validation and system performance assessments. In addition, further work is needed to resolve the higher than expected velocities for the smaller S1D2 particles. Initial measurements conducted with buoyant beads as fluid velocity tracers indicate that fluid velocities can be subtracted from the increased particle velocities to determine the particle terminal velocity, regardless of the surrounding fluid velocity. However, this approach is in its infancy and will need to be carefully and methodically validated. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Uncovering the Size-dependent Thermal Solid Transformation of Akaganéite

Investigating the structural evolution and phase transformation of iron oxides is crucial for gaining a deeper understanding of geological changes on diverse planets and preparing oxide materials suitable for industrial applications. In this study, we employed in-situ heating techniques in conjunction with transmission electron microscopy (TEM) observations and ex-situ characterization to thoroughly analyze the thermal solid-phase transformation of akaganéite one-dimensional (1D) nanostructures with varying diameters. Our findings offer compelling evidence for a size-dependent morphology evolution in akaganéite 1D nanostructures, which can be attributed to the transformation from akaganéite to maghemite (?-Fe2O3) and subsequent crystal growth. Specifically, we observed that akaganéite nanorods with a diameter of around 50 nm transformed into hollow polycrystalline maghemite nanorods, which demonstrated remarkable stability without arresting crystal growth under continuous heating. In contrast, smaller akaganéite nanoneedles or nanowires with a diameter ranging from 20 to 8 nm displayed a propensity for forming single-crystal nanoneedles or nanowires through phase transformation and densification. By manipulating the size of the precursors, we have developed a straightforward method for the synthesis of single-crystal and polycrystalline maghemite nanowires through solid-phase transformation. These significant findings provide new insights into the size-dependent structural evolution and phase transformation of iron oxides at the nanoscale.

Wang, Xiang↗

Quantifying structural errors in cloud condensation nuclei activity from reduced representation of aerosol size distributions

Aerosol effects on clouds and radiation are the dominant contribution to uncertainty in radiative forcing relative to the pre-industrial atmosphere. While previous studies have assessed the impact of parametric uncertainty on modeled forcing, structural errors from the numerical representation of particle distributions have not been well quantified. Here we present a framework for quantifying error in aerosol size distributions and cloud condensation nuclei activity, which we apply to the widely used 4-mode version of the Modal Aerosol Module (MAM4). Box model predictions from the MAM4 are evaluated against the Particle Monte Carlo Model for Simulating Aerosol Interactions and Chemistry (PartMC-MOSAIC), a benchmark model that tracks the evolution of individual particles. We show that size distributions simulated by MAM4 diverge from those simulated by PartMC-MOSAIC after only a few hours of aging by condensation and coagulation in polluted conditions, which leads to large errors in modeled cloud condensation nuclei concentrations. We find that differences between MAM4 and PartMC-MOSAIC are largest under polluted conditions, where the size distribution evolves rapidly though aging by condensation of semi-volatile substances and coagulation among particles. These findings suggest that structural error in modeled aerosol properties contributes to the large inter-model variability in aerosol radiative forcing.

Fierce, Laura M.↗

Ab-Initio Investigation of Finite Size Effects in Rutile Titania Nanoparticles with Semilocal and Nonlocal Density Functionals

In this work, we employ hybrid and generalized gradient approximation (GGA) level density functional theory (DFT) calculations to investigate the convergence of surface properties and electronic gap of rutile titania nanoparticles with particle size. The surface energies and electronic gaps are calculated for cuboidal particles with minimum dimension ranging from 3.7 Angstrom (24 atoms) to 10.3 Angstrom (384 atoms) using a highly-parallel real-space DFT code to enable hybrid level DFT calculations of larger nanoparticles than are typically practical. We deconvolute the geometric and electronic finite size effects in surface energy, and evaluate the influence of defects on electronic gap and density of states (DOS). The electronic finite size effects in surface energy vanish when the minimum length scale of the nanoparticles becomes greater than 10 Angstrom. We show that this length scale is consistent with a computationally efficient numerical analysis of the characteristic length scale of electronic interactions. The surface energy of nanoparticles having minimum dimension beyond this characteristic length can be approximated using slab calculations that account for the geometric defects. In contrast, the finite size effects on the electronic gap and DOS is highly dependent on the shape and size of these particles. Furthermore, the DOS for cuboidal particles and more realistic particles constructed using the Wulff algorithm reveal that defect states within the electronic gap play a key role in determining the eigen value distribution of nanoparticles and the electronic gap does not converge to the bulk limit for the particle sizes investigated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

3D Morphology of Bimodal Porous Copper with Nano-Sized and Micron-Sized Pores to Enhance Transport Properties for Functional Applications

Multiscale porous metals with multiscale porosity from nanometer to micrometer have a high specific surface area and high effective diffusivity for ion transport, thereby enhancing functionalities and extending the applications of porous metals. Herein, the Cu–Fe–Al ternary system was selected as the precursor alloy to construct multiscale, bimodal porous copper by the chemical dealloying method. The effect of the phase composition and initial microstructure of precursor alloys (Al x Fe 75– x Cu 25 , x = 10–60) on the three-dimensional (3D) morphology of multiscale porous metals was systematically investigated, with a goal to precisely control the multiscale porous structure. The four crystal structure phases (body-centered cubic (BCC), face-centered cubic (FCC), CsCl type (B2), and monoclinic) in precursor alloys were analyzed by synchrotron X-ray diffraction refinement. The 3D morphology, feature size distribution, and tortuosity of four representative porous Cu after dealloying Al x Fe 75– x Cu 25 ( x = 10, 30, 50, and 60) precursor alloys were directly visualized and quantified via advanced synchrotron X-ray nanotomography. The relationship between the phases/crystal structures of precursor alloys and their corresponding porous morphology was established: the micron-sized pores in bimodal porous Cu are formed by dissolving the CuFeAl phase with BCC and monoclinic crystal structures, and the nano-sized pores are formed by dealloying the CuFeAl phase with FCC and B2 crystal structures. The size of the nanoporous structure depends on the ratio between the more noble and more active components in the precursor alloy, while the size of the microporous structure depends on the corresponding phase size in the precursor alloy. The tortuosity results showed that the multiscale porous structure with both nanoporosity and microporosity exhibits lower tortuosity, which will enhance transport properties for functional applications.

25 ENERGY STORAGE↗

Quantum Dot Size Dependent J - V Characteristics in Heterojunction ZnO/PbS Quantum Dot Solar Cells

The current-voltage (J-V) characteristics of ZnO/PbS quantum dot (QD) solar cells show a QD size-dependent behavior resulting from a Schottky junction that forms at the back metal electrode opposing the desirable diode formed between the ZnO and PbS QD layers. We study a QD size-dependent roll-over effect that refers to the saturation of photocurrent in forward bias and crossover effect which occurs when the light and dark J-V curves intersect. We model the J-V characteristics with a main diode formed between the n-type ZnO nanocrystal (NC) layer and p-type PbS QD layer in series with a leaky Schottky-diode formed between PbS QD layer and metal contact. We show how the characteristics of the two diodes depend on QD size, metal work function, and PbS QD layer thickness, and we discuss how the presence of the back diode complicates finding an optimal layer thickness. Finally, we present Kelvin probe measurements to determine the Fermi level of the QD layers and discuss band alignment, Fermi-level pinning, and the Voc within these devices.

36 MATERIALS SCIENCE↗

Simple size-controlled synthesis of Au nanoparticles and their size-dependent catalytic activity

The controlled preparation of Au nanoparticles (NPs) in the size range of 6 to 22 nm is explored in this study. The Au NPs were prepared by the reduction of tetrachloroauric acid using maltose in the presence of nonionic surfactant Tween 80 at various concentrations to control the size of the resulting Au NPs. With increasing concentration of Tween 80 a decrease in the size of produced Au NPs was observed, along with a significant decrease in their size distribution. The size-dependent catalytic activity of the synthesized Au NPs was tested in the reduction of 4-nitrophenol with sodium borohydride, resulting in increasing catalytic activity with decreasing size of the prepared nanoparticles. Eley-Rideal catalytic mechanism emerges as the more probable, in contrary to the Langmuir-Hinshelwood mechanism reported for other noble metal nanocatalysts.

36 MATERIALS SCIENCE↗

Size consistent formulations of the perturb-then-diagonalize Møller-Plesset perturbation theory correction to non-orthogonal configuration interaction

In this paper we introduce two size consistent forms of the non-orthogonal configuration interaction with second-order Møller-Plesset perturbation theory method, NOCI-MP2. We show that the original NOCI-MP2 formulation [S. R. Yost, T. Kowalczyk, and T. VanVoorh, J. Chem. Phys. 193, 174104 (2013)], which is a perturb-then-diagonalize multi-reference method, is not size consistent. We also show that this causes significant errors in large systems like the linear acenes. By contrast, the size consistent versions of the method give satisfactory results for singlet and triplet excited states when compared to other multi-reference methods that include dynamic correlation. For NOCI-MP2 however, the number of required determinants to yield similar levels of accuracy is significantly smaller. These results show the promise of the NOCI-MP2 method, though work still needs to be done in creating a more consistent black-box approach to computing the determinants that comprise the many-electron NOCI basis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Size‐Dependent Crystal Properties of Nanocuprite

Cuprite nanoparticles from 9 nm to 1 μm with narrow size distribution (±7%) are prepared by two different methods. The lattice parameter increases up to 0.2% as the crystallite size decreases to 9 nm from micron size. X‐ray Absorption Near Edge Spectroscope study of our copper oxide nanoparticles shows mostly Cu (I) with increasing concentration of Cu ( II ) as decreasing crystal sizes. The size effect in Cu( II )/Cu(I) ratio indicates that at smaller crystal size, the Cu 2 O tends to be more oxidized at higher charge state with Cu(I)‐O bond. Thus, the lattice expansion can be explained by the presence of longer Cu ( II )‐O bond than Cu (I)‐O bond and/or oxygen interstitials in nanocuprite.

Song, Junhua↗

Size Effect on Nuclear Gamma-Ray Energy Spectra Acquired by Different Sized CeBr3, LaBr3:Ce, and NaI:Tl Gamma-Ray Detectors

Gamma-ray energy spectra were acquired for different sizes of cerium tribromide (CeBr3), cerium-doped lanthanum tribromide (LaBr3:Ce), and thallium-doped sodium iodide (NaI:Tl) detectors. A comparison was conducted of the energy resolution and detection efficiency of these scintillator detectors for different sizes of detectors. The results of this study are consistent with the observation that for each size detector, LaBr3:Ce offers better resolution than either a CeBr3 or NaI:Tl detector of the same size. In addition, CeBr3 and LaBr3:Ce detectors could resolve some closely spaced peaks in the spectra of several radioisotopes that NaI:Tl could not. As the detector size increased, all three detector materials exhibited higher efficiency, albeit with slightly reduced resolution. Significantly, the very low intrinsic activity of CeBr3 is also demonstrated in this study, which, when combined with energy resolution characteristics for a range of detector sizes, could lead to an improved ability to detect special nuclear materials compared to the other detectors.

actinium-227↗

Size-dependent selectivity and activity of silver nanoclusters in the partial oxidation of propylene to propylene oxide and acrolein : A joint experimental and theoretical study.

Model silver nanocatalysts between 9 and 23 nm in size were prepared by size-selected cluster deposition from a free cluster beam on amorphous alumina films and their size-dependent catalytic performance studied in the partial oxidation of propylene under realistic reaction conditions. Smaller clusters preferentially produced acrolein, while the 23 nm particles were considerably more selective towards the formation of propylene oxide, at reaction rates far exceeding those previously reported for larger silver particles. The activity of clusters dropped significantly with increasing particle size. First-principle calculations, of the activation energies for oxygen adsorption and its dissociation, at variable surface coverage yielded surface energies which resulted in particle shapes resembling the experimentally observed shapes of partially oxidized silver clusters. The calculated activation barriers for propylene oxide and acrolein formation on various facets and on the edges of the nanoparticles provided detailed information about the energetics of the competing reaction pathways. The size- and corresponding morphology dependent theoretical activity and selectivity are in good accord with experimental observations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗