Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sim”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Model Package Report: Hanford Soil Inventory Model SIM v.2 Build 1

The Hanford Soil Inventory Model (SIM) is a tool for the estimation of inventory of contaminants that were released to soil from liquid discharges during the U.S. Department of Energy’s Hanford Site operations. This model package report documents the construction and development of a second version of SIM (SIM-v2) to support the needs of Hanford Site Composite Analysis. The SIM-v2 is implemented using GoldSim Pro® 1 software with a new model architecture that preserves the uncertainty in inventory estimates while reducing the computational burden (compared to the previous version) and allowing more traceability and transparency in calculation methodology. The calculation architecture is designed in such a manner that future updates to the waste stream composition along with addition or deletion of waste sites can be performed with relative ease. In addition, the new computational platform allows for continued hardware upgrade.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Updates to the Hanford Soil Inventory Model (SIM Version 2) for FY 2023

The purpose of this environmental calculation file (ECF) is to document the updates made to the Soil Inventory Model version 2.1 (SIM-v2.1) (ECF-HANFORD-21-0073, Updates to the Hanford Soil Inventory Model (SIM Version 2) for FY 2021) in FY 2023. These updates to SIM-v2.1 are referred to as the SIM-v2.2 version. The following updates have been made: • Include inventory estimate for a new analyte • hexavalent chromium (Cr(VI)), separate from total chromium inventory • Revise the inventory discharged to the 216-U-10 and 216-T-4 Pond systems based on partitioning of waste streams discharges over time and space among influent ditches and ponds • Enhance the preprocessing and postprocessing of the input and output files Note that the methodology for estimating Cr(VI) inventories is based on ECF-200W-23-0040, Recommendations for Updating Liquid Discharged Inventory and Transport Modeling Parameters for Cumulative Impacts Evaluation of Hexavalent Chromium in the 200 West Area while the revision of inventory discharged to the 216-U-10 and 216-T-4 Pond systems is based on ECF-HANFORD-19-0032, Distribution of Infiltration in the 216-U-10, 216-B-3 Pond, and 216-T-4 Pond Systems 1944-1997.

54 ENVIRONMENTAL SCIENCES↗

WEC-Sim (Wave Energy Converter - SIMulator)

WEC-Sim (Wave Energy Converter SIMulator) is a code developed by Sandia National Laboratories and the National Renewable Energy Laboratory to model wave energy converters (WECs) when they are subject to operational waves. The code is a time-domain modeling tool developed in MATLAB/Simulink using the multi-body dynamics solver SimMechanics. In WEC-Sim, WECs are modeled by connecting rigid bodies to one another with joint or constraint blocks from the WEC-Sim library. WEC-Sim is a publicly available, open-source code to model WECs.

Source record↗

WEC-Sim Array Development and Experimental Comparison Study: Preprint

Wave energy is still considered to be an emerging industry, and one significant contribution that researchers are making is to find solutions that reduce costs. The National Renewable Energy Laboratory and Sandia National Laboratories have contributed to this by creating WEC-Sim, an opensource modeling toolbox, to assist with early design decisions related to the design of wave energy converters (WECs). Previously, studies involving WEC-Sim have focused on single WEC modeling. In this paper, we will conduct a validation study to investigate the accuracy and ability of WEC-Sim to model arrays of WECs. The results from the WEC-Sim array simulations are compared to those from an existing experimental study. In addition, the array model is used to investigate the interaction between the WECs in the array and the influence of array spacing on the WECs' hydrodynamic performance.

16 TIDAL AND WAVE POWER↗

Indigenous Organic Molecular Biosignatures are Detectable via ToF-SIMS of a Kerogen-rich Jurassic Clay

Time of Flight - Secondary Ion Mass Spectrometry (ToF-SIMS) is a Mass Spectrometry (MS) imaging technique that can be used in conjunction with traditional organic geochemical analysis (organics extracted from a crushed sample) in order to determine how molecules observed in the organic extracts were incorporated into a particular rock sample. This type of analysis may be used on samples collected as part of Mars Sample Return (MSR) in order to determine if potential organic compounds were indigenous to Mars or whether they are contaminants.Here we show that Organic Molecular Biosignatures (OMBs including steranes and derivatives of a carotenoid) are detectable via ToF-SIMS within a Jurassic mudstone. The OMBs are only detectable in areas with high organic carbon, likely kerogen, indicating that they are indigenous to the rock. We conclude that: I) Indigenous OMBs are detectable via ToF-SIMS in ancient, kerogen-rich samples; II) the presence of a molecular ion strengthens the interpretation of ToF-SIMS spectra of complex natural material, and III) the spatial co-occurrence of kerogen and potentially indigenous OMBs in ancient sediments is a valid test of their character. These conclusions are directly relevant to MSR sample selection as well as the analysis of MSR samples upon return.

Pasterski, Michael↗

Nanoscale imaging of Li and B in nuclear waste glass, a comparison of ToF-SIMS, NanoSIMS, and APT: Nanoscale imaging of Li and B in nuclear waste glass

It has been very difficult to use popular elemental imaging techniques to image Li and B distribution in glass samples with nanoscale resolution. In this study, atom probe tomography (APT), time-of-flight secondary ion mass spectrometry (ToF-SIMS), and nanoscale secondary ion mass spectrometry (NanoSIMS) were used to image the distribution of Li and B in two representative glass samples. APT can provide three-dimensional Li and B imaging with very high spatial resolution (≤ 2 nm). In addition, absolute quantification of Li and B is possible, though room remains to improve accuracy. However, the major drawbacks of APT include limited field of view (normally ≤ 100 × 100 × 500 nm 3 ) and poor sample compatibility. As a comparison, ToF-SIMS and NanoSIMS are sample-friendly with flexible field of view (up to 500 × 500 μm 2 and image stitching is feasible); however, lateral resolution is limited to only about 100 nm. Therefore, SIMS and APT can be regarded as complementary techniques for nanoscale imaging Li and B in glass and other novel materials.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Study of the Au-Cr bilayer system using X-ray reflectivity, GDOES, and ToF-SIMS

Here, we study a Au (25 nm)/Cr (10 nm) bilayer system as a model of mirror for the soft X–ray energy range. The Au and Cr thin films are a few nanometer thick and are deposited on a float glass substrate. The sample is characterized by using 3 complementary techniques: soft X–ray reflectivity, glow discharge optical emission spectrometry (GDOES), and time–of–flight secondary ion mass spectroscopy (ToF–SIMS). Soft X–ray reflectivity provides information about the thickness and roughness of the different layers, while GDOES is used to obtain the elemental depth profile of the stack and ToF–SIMS to obtain the elemental and chemical depth profiles. GDOES and ToF–SIMS have both a nanometer depth resolution. A coherent description of the bilayer stack is obtained through the combination of these techniques. It consists in 5 layers namely a surface contamination layer, a principal gold layer, a Au–Cr mixed layer, a Cr layer, and another contamination layer at the top of the substrate.

36 MATERIALS SCIENCE↗

Probing Perovskite Inhomogeneity beyond the Surface: TOF-SIMS Analysis of Halide Perovskite Photovoltaic Devices

Understanding the origins and evolution of inhomogeneity in halide perovskite solar cells appears to be a key to advancing the technology. Time-of-flight secondary-ion mass spectrometry (TOF-SIMS) is one of the few techniques that can obtain chemical information from all components of hybrid organic-inorganic perovskite photovoltaics in one dimension (standard depth profiling), two dimensions (high-resolution 100-nm imaging), as well as three dimensions (tomography combining high-resolution imaging with depth profiling). TOF-SIMS has been used to analyze perovskite photovoltaics made by a variety of methods, and the breadth of insight that can be gained from the technique is illustrated here including: cation uniformity (depth and lateral), changes in chemistry upon alternate processing, changes in chemistry upon degradation, and lateral distribution of additives that passivate grain boundaries. Using TOF-SIMS on multiple perovskite compositions, we show information regarding hybrid perovskite formation as well as inhomogeneity critical to device performance can be extracted providing one of the best proxies for understanding compositional changes resulting from degradation. Here, we also describe in detail the measurement artifacts and recommended best practices that enable unique insight regarding hybrid perovskite solar cell materials and devices.

14 SOLAR ENERGY↗

Mitigating Measurement Artifacts in TOF-SIMS Analysis of Perovskite Solar Cells

Time-of-flight secondary ion mass spectrometry (TOF-SIMS) is one of the few techniques that can specifically distinguish between organic cations such as methylammonium and formamidinium. Distinguishing between these two species can lead to specific insight into the origins and evolution of compositional inhomogeneity and chemical gradients in halide perovskite solar cells, which appears to be a key to advancing the technology. TOF-SIMS can obtain chemical information from hybrid organic-inorganic perovskite solar cells (PSCs) in up to three dimensions, while not simply splitting the organic components into their molecular constituents (C, H, and N for both methylammonium and formamidinium), unlike other characterization methods. Here, we report on the apparently ubiquitous A-site organic cation gradient measured when doing TOF-SIMS depth-profiling of PSC films. Using thermomechanical methods to cleave perovskite samples at the buried glass/transparent conducting oxide interface enables depth profiling in a reverse direction from normal depth profiling (backside depth profiling). When comparing the backside depth profiles to the traditional front side profiled devices, an identical slight gradient in the A-site organic cation signal is observed in each case. This indicates that the apparent A-site cation gradient is a measurement artifact due to beam damage from the primary ion beam causing a continually decreasing ion yield for secondary ions of methylammonium and formamidinium. This is due to subsurface implantation and bond breaking from the 30 keV bismuth primary ion beam impact when profiling with too high of a data density. Here, we show that the beam-generated artifact associated with this damage can mostly be mitigated by altering the measurement conditions. We also report on a new method of depth profiling applied to PSC films that enables enhanced sensitivity to halide ions in positive measurement polarity, which can eliminate the need for a second measurement in negative polarity in most cases.

14 SOLAR ENERGY↗

Understanding Measurement Artifacts Causing Inherent Cation Gradients in Depth Profiles of Perovskite Photovoltaics with TOF-SIMS

Time-of-flight secondary-ion mass spectrometry (TOF-SIMS) is one of the few techniques that can obtain chemical information from the hybrid organic-inorganic perovskite solar cells (PSCs) in one dimension (standard depth profiling), two dimensions (high-resolution 100-nm imaging), as well as three dimensions (tomography combining high-resolution imaging with depth profiling). We have very recently developed thermo-mechanical methods to cleave perovskite samples at the back transparent conducting oxide/PSC interface. This allowed for depth-profiling from the back of the device to the front. The resultant profiles answered the lingering question of the apparent A-site cation gradient typically seen in TOF-SIMS depth profiles. In fact, this gradient is a measurement artifact due to beam damage that the community should be informed of as TOF-SIMS data become more commonly employed. Methods of mitigating this artifact by altering the measurement conditions are also presented.

14 SOLAR ENERGY↗

Switchable 1,8-diazabicycloundec-7-ene and 1-hexanol ionic liquid analyzed by liquid ToF-SIMS

Switchable ionic liquids (SWIL) play an important role in green chemistry. Due to the nature of SWIL chemistry, such as air sensitivity and pressure and temperature dependence, it is difficult to characterize SWIL using vacuum-based surface techniques. The fully CO2 loaded and none-loaded DBU and hexanol mixtures, a SWIL system, were analyzed in situ by time-of-flight secondary ion mass spectrometry (ToF-SIMS) coupled with the System for Analysis at the Liquid Vacuum Interface (SALVI), respectively. The DBU/Hexanol/CO2 SWIL was injected into the microchannel before liquid SIMS analysis. Bi3+ primary ion beam was used. The positive and negative spectra of the SWIL chemical components are presented. The characteristic peaks m/z 153 (reduced DBU) in the positive mode and m/z 101 (oxidized hexanol) in negative mode were observed. In addition, ion pair peaks including m/z 253, 319, 305, 451 in the positive mode and m/z 145, 223, 257 in the negative mode are first observed using this approach. These results demonstrate that the SALVI microfluidic reactor enables the vacuum-based surface technique (i.e., ToF-SIMS) for in situ characterization of challenging liquid samples such as ionic liquids.

DBU, hexanol↗

HERO WEC V1.0 2024 - WEC-Sim Detailed Simulation Runs and Summary Data

This dataset includes results from simulations of NREL's hydraulic and electric reverse osmosis wave energy converter (HEREO WEC). Simulation runs include 135 wave cases that were based on the updated WEC-Sim model, which is linked below. The data represented in this repository is based on an updated WEC-Sim model using laboratory data to tune and refine the original WEC-Sim model for the V1.0 HERO WEC. The 135 wave cases represent waves with the following wave height and wave period ranges: - Significant Wave Height: 0.25 - 3.75m in 0.25m increments - Wave Period: 5 - 13 sec in 1 sec increments Each run was simulated using a Pierson-Moskowitz irregular wave spectrum with a 100 second ramp time, a total simulation time of 3,100 seconds, and a simulation time-step of 0.005s. A reference table has been included to map each multi condition run (MCR) case with each wave condition. Summary data set includes a spreadsheet and image files with matrices that are associated with data from simulation runs. All matrices cover the same significant wave height and wave periods from the simulation runs, in the same increments. The following matrices are included: - Power Abs: The average absorbed power from the WEC (calculated from anchor reaction force and heave velocity) - Power Hyd: The average hydraulic power output at pump (calculated from pump output flow and pressure) - Power - Hyd ROi: The average hydraulic power measured at the RO system inlet (calculated from RO system pressure and flow (pre-accumulator)) - Flow - Pump out: The average flowrate measured at the pump outlet - Flow - Perm: The average permeate (clean water) production - Flow - RO (pre): The average flowrate measured at the inlet of the RO system before the accumulators - Flow - RO (post): The average flowrate measured after the accumulator bank in the RO system - Pressure - RO: The average pressure measured at the inlet of the RO system This data set has been developed by the National Renewable Energy Laboratory, operated by the Alliance for Sustainable Energy, LLC, for the U.S. Department of Energy (DOE) under Contract No. DE-AC36-08GO28308. Funding provided by the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Water Power Technologies Office.

16 TIDAL AND WAVE POWER↗

SIMS Analysis of d18O and d13C of Carbonate Cements in Shale & Mudstone. Final report

This project has had two primary goals: 1) improving new technology for in situ microanalysis of stable isotope ratios by SIMS (secondary ion mass spectrometry) and 2) evaluating the importance of in situ analysis for studies of carbonate cements within shales of the Bakken Petroleum System. The systematic relations of stable isotope ratios provide an important tool to help resolve critical questions in geology. Stable isotope analysis of carbonate cements in shale constrain many topics of interest to DOE including: CO2 sequestration, climate change, and the genesis and quality of rock reservoirs for petroleum, natural gas, and water. However, this evidence is often preserved as fine-scale zonation, which is homogenized by conventional bulk analysis of powders. Recently, analysis of ultra-small spots in polished samples at the University of Wisconsin WiscSIMS Lab. has documented stable isotope zoning in carbonates and other diagenetic cements at smaller scales than previously possible. We have made detailed studies of oxygen and carbon isotope ratios in diagenetic cements from shales of the Bakken Formation from the Williston basin and elsewhere. The Bakken contains both reservoir and source rocks for petroleum. Hydrofracturing has greatly enhanced production of oil in these tight reservoirs. The sediments contain zoned carbonate cements with growth textures that record multiple events. The growth of carbonate (dolomite) cements has been proposed to control reservoir quality, but previous stable isotope studies of homogenized powders could not resolve individual generations of cement and this proposal remains untested. Our better characterization of the multiple growth zones in these carbonates will aid in understanding the genesis of these tight reservoirs and the production of unconventional oil and gas. This study has also developed SIMS standards for analysis of all compositions of Ca-Mg-Fe carbonate and selected Mn-carbonates and hydromagnesite. We have refined techniques for improved accuracy of SIMS stable isotope analysis, and for sub-1-micron spot sizes. We have established protocols for mapping and correlating sample analyses at micron-scale using QGIS software.

04 OIL SHALES AND TAR SANDS↗

In Situ SIMS and IR Spectroscopy of Well-Defined Surfaces Prepared by Soft Landing of Mass-Selected Ions

Soft landing of mass-selected ions onto surfaces is a powerful approach for the highly-controlled preparation of materials that are inaccessible using conventional synthesis techniques. Coupling soft landing with in situ characterization using secondary ion mass spectrometry (SIMS) and infrared reflection absorption spectroscopy (IRRAS) enables analysis of well-defined surfaces under clean vacuum conditions. The capabilities of three soft-landing instruments constructed in our laboratory are illustrated for the representative system of surface-bound organometallics prepared by soft landing of mass-selected ruthenium tris(bipyridine) dications, [Ru(bpy)3]2+, onto carboxylic acid terminated self-assembled monolayer surfaces on gold (COOH-SAMs). In situ time-of-flight (TOF)-SIMS provides insight into the reactivity of the soft-landed ions. In addition, the kinetics of charge reduction, neutralization and desorption occurring on the COOH-SAM both during and after ion soft landing are studied using in situ Fourier transform ion cyclotron resonance (FT-ICR)-SIMS measurements. In situ IRRAS experiments provide insight into how the structure of organic ligands surrounding metal centers is perturbed through immobilization of organometallic ions on COOH-SAM surfaces by soft landing. Collectively, the three instruments provide complementary information about the chemical composition, reactivity and structure of well-defined species supported on surfaces.

in situ↗

WEC-Sim Wave Energy Converter Simulator

WEC-Sim (Wave Energy Converter SIMulator) is an open-source wave energy converter (WEC) simulation tool. The code is developed in MATLAB/SIMULINK using the multi-body dynamics solver SimMechanics. WEC-Sim has the ability to model devices that are comprised of rigid bodies, power-take-off systems, and mooring systems. Simulations are performed in the time-domain by solving the governing WEC equations of motion in 6 degrees-of-freedom. The WEC-Sim project is funded by the U.S. Department of Energy's Wind and Water Power Technologies Office and the code development effort is a collaboration between the National Renewable Energy Laboratory (NREL) and Sandia National Laboratories (SNL).

13 HYDRO ENERGY↗

Improving the Molecular Ion Signal Intensity for In Situ Liquid SIMS Analysis

In situ liquid secondary ion mass spectrometry (SIMS) enabled by system for analysis at the liquid vacuum interface (SALVI) has proven to be a promising new tool to provide molecular information at solid–liquid and liquid–vacuum interfaces. However, the initial data showed that useful signals in positive ion spectra are too weak to be meaningful in most cases. In addition, it is difficult to obtain strong negative molecular ion signals when m/z>200. These two drawbacks have been the biggest obstacle towards practical use of this new analytical approach. In this study, we report that strong and reliable positive and negative molecular signals are achievable after optimizing the SIMS experimental conditions. Four model systems, including a 1,8-diazabicycloundec-7-ene (DBU)-base switchable ionic liquid, a live Shewanella oneidensis biofilm, a hydrated mammalian epithelia cell, and an electrolyte popularly used in Li ion batteries were studied. A signal enhancement of about two orders of magnitude was obtained in comparison with non-optimized conditions. Therefore, molecular ion signal intensity has become very acceptable to use for in situ liquid SIMS to study solid–liquid and liquid–vacuum interfaces.

36 MATERIALS SCIENCE↗

Investigation of the Ionization Mechanism of NAD{sup +}/NADH-Modified Gold Electrodes in ToF-SIMS Analysis

Analysis of nicotinamide adenine dinucleotide (NAD{sup +}/NADH)-modified electrodes is important for in vitro monitoring of key biological processes. In this work, time-of-flight secondary ion mass spectrometry (ToF-SIMS) was used to analyze NAD{sup +}/NADH-modified gold electrodes. Interestingly, no obvious characteristic peaks of nicotinamide fragment could be observed in the mass spectra of NAD{sup +}/NADH in their neutral sodium pyrophosphate form. However, after acidification, the characteristic peaks for both NAD{sup +} and NADH were detected. This was due to the suppression effect of inner pyrophosphoric salts in both neutral molecules. Besides, it was proved that the suppression by inner salt was intramolecular. No obvious suppression was found between neighboring molecules. These results demonstrated the suppression effect of inner salts in ToF-SIMS analysis, providing useful evidence for the study of ToF-SIMS ionization mechanism of organic molecule-modified electrodes. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MeV-SIMS TOF Imaging of Organic Tissue with Continuous Primary Beam

MeV-SIMS is an emerging mass spectrometry imaging method, which utilizes fast, heavy ions to desorb secondary molecules. High yields and low fragmentation rates of large molecules, associated with the electronic sputtering process, make it particularly useful in biomedical research, where insight into distribution of organic molecules is needed. Since the implementation of MeV-SIMS in to the micro-beam line at the tandem accelerator of Jožef Stefan Institute, MeV-SIMS provided some valuable observations on the distribution of biomolecules in plant tissue, as discussed by Jenčič et al. (Nucl. Inst. Methods Phys. Res. B. 371, 205–210, 2016; Nucl. Inst. Methods Phys. Res. B. 404, 140–145, 2017). However, limited focusing ability of the chlorine ion beam only allowed imaging at the tissue level. In order to surpass shortcomings of the existing method, we introduced a new approach, where we employ a continuous, low-current primary beam. In this mode, we bombard thin samples with a steady chlorine ion flux of approx. 5000 ions/s. After desorbing molecules, chlorine ions penetrate through the thinly cut sample and trigger the time-of-flight “start” signal on a continuous electron multiplier detector, positioned behind the sample. Such bombardment is more effective than previously used pulsing-beam mode, which demanded several orders of magnitude higher primary ion beam currents. Sub-micrometer focusing of low-current primary ion beam allows imaging of biological tissue on a subcellular scale. Simultaneously, new time-of-flight acquisition approach also improves mass resolution by a factor of 5. Within the article, we compare the performance of both methods and demonstrate the application of continuous mode on biological tissue. We also describe the thin sample preparation protocol, necessary for measurements with low primary ion currents. .

74 ATOMIC AND MOLECULAR PHYSICS↗