Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Efficient fully-coherent quantum signal processing algorithms for real-time dynamics simulation

Simulating the unitary dynamics of a quantum system is a fundamental problem of quantum mechanics, in which quantum computers are believed to have significant advantage over their classical counterparts. One prominent such instance is the simulation of electronic dynamics, which plays an essential role in chemical reactions, non-equilibrium dynamics, and material design. These systems are time-dependent, which requires that the corresponding simulation algorithm can be successfully concatenated with itself over different time intervals to reproduce the overall coherent quantum dynamics of the system. In this paper, we quantify such simulation algorithms by the property of being fully-coherent: the algorithm succeeds with arbitrarily high success probability 1 − δ while only requiring a single copy of the initial state. Here we subsequently develop fully-coherent simulation algorithms based on quantum signal processing (QSP), including a novel algorithm that circumvents the use of amplitude amplification while also achieving a query complexity additive in time t, ln(1/δ), and ln(1/ϵ) for error tolerance ϵ: $Θ‖\mathscr{H}‖|t|+ln(1/ϵ)+ln(1/δ)$. Furthermore, we numerically analyze these algorithms by applying them to the simulation of the spin dynamics of the Heisenberg model and the correlated electronic dynamics of an H2 molecule. Since any electronic Hamiltonian can be mapped to a spin Hamiltonian, our algorithm can efficiently simulate time-dependent ab initio electronic dynamics in the circuit model of quantum computation. Accordingly, it is also our hope that the present work serves as a bridge between QSP-based quantum algorithms and chemical dynamics, stimulating a cross-fertilization between these exciting fields.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Atom-Precise Approach to Damp First-Order Phase Transitions and Its Implications for Neuromorphic Signal Processing

Neuromorphic computing inspired by mammalian intelligence aims to emulate the nonlinear dynamics of biological neurons and synapses to achieve fast, low-energy, and highly efficient information processing. Brain-inspired computing relies on the design and discovery of materials exhibiting nonlinear current–voltage profiles, frequently underpinned by electronic state transitions, to achieve spiking neurons and dynamically tunable synapses. A signature challenge in the design of artificial neurons is controlling the steepness of first-order transitions in active elements, as abrupt transitions are at risk of driving unstable voltage and temperature oscillations, which result in catastrophic device failure. A critical knowledge gap is the lack of structure–function correlations mapping the composition and atomistic structure of crystalline solids to nonlinear dynamical response characteristics. Here, we address the key question of how modification of atomistic structure correlates with alteration of neuron-like functionality. Constructing oscillator circuits from millimeter-scale single crystals enables high-resolution atomic structure solutions, which we use to demonstrate that the selective positioning of Pb cations modifies charge ordering along a one-dimensional CuxV2O5 framework even at low insertion stoichiometries, thereby providing an atom-precise design parameter for damping first-order transitions. We use temperature-variant X-ray diffraction and X-ray spectroscopy to elucidate the suppression of Cu-ion shuttling based on the precise positioning of Pb ions in seven-coordinated tunnel interstitial sites as the mechanistic basis for transition broadening, thus bridging a critical gap between statistical mechanics and quantum chemical descriptions of phase transitions. Such mechanistic understanding thus paves the way to site-selective modification strategies for modulating the sharpness of first-order transitions, with an exemplary demonstration here in tuning neuronal signal processing.

Crystal structure↗

Archaeological applications of laser-induced breakdown spectroscopy: an example from the Coso Volcanic Field, California, using advanced statistical signal processing analysis

Over the past quarter century, multielement chemical analysis has become a common means for attributing the provenance of archaeological materials. The Coso Volcanic Field (CVF) in California, USA, contains at least 38 high-silica rhyolite domes, many of which contain obsidian glass that has been quarried for tools by the indigenous population for more than 12,000 years. Artifacts made from CVF obsidian are found throughout the southwestern United States and geochemical sourcing of CVF obsidian has been an important tool in understanding prehistoric Native American trading patterns. Laser-induced breakdown spectroscopy (LIBS) is a simple atomic emission spectroscopic technique that has the potential for real-time man-portable chemical analysis in the field. Because LIBS is simultaneously sensitive to all elements, a single laser shot can be used to record the broadband emission spectra, which provides a ''chemical fingerprint'' of a material. Single-shot broadband LIBS spectra were collected using a commercial benchtop LIBS system for 27 obsidian samples from major sites across the CVF and four additional sites in California and western Nevada outside of CVF. Classification of the samples was performed using partial least-squares discriminant analysis (PLSDA), a common chemometric technique suitable for performing regression on high-dimensional data. Provenance identification for the obsidian samples was evaluated for three separate labeling frameworks. The first framework consisted of a binary classification problem to distinguish CVF samples from non-CVF samples. The second approach focused on the CVF samples with labels that corresponded to the eight separate Coso sites encompassed by the 27 samples. In the third analysis, non-CVF samples were excluded, and the remaining 27 CVF samples were labeled based on groupings defined from previous major and trace element chemical studies, which reduces the number of possible classes from eight to four. Different aspects of the classifier setup considered in this study include the training/testing routine (a 27-fold leave-one-sample-out setup versus a simple split of the data into separate sets for training and evaluation), the number of latent variables used in the regression model, and whether PLSDA operating on the entire broadband LIBS spectrum is superior to that using only a selected subset of LIBS emission lines. The results point to the robustness of the PLSDA technique and suggest that LIBS analysis combined with the appropriate statistical signal processing has the potential to be a useful tool for chemical analysis of archaeological artifacts and geological specimens.

74 ATOMIC AND MOLECULAR PHYSICS↗

Decoding Signal Processing at the Single-Cell Level

The ability of cells to detect and decode information about their extracellular environment is critical to generating an appropriate response. In multicellular organisms, cells must decode dozens of signals from their neighbors and extracellular matrix to maintain tissue homeostasis while still responding to environmental stressors. How cells detect and process information from their surroundings through a surprisingly limited number of signal transduction pathways is one of the most important question in biology. Despite many decades of research, many of the fundamental principles that underlie cell signal processing remain obscure. However, in this issue of Cell Systems, Gillies et al present compelling evidence that the early response gene circuit can act as a linear signal integrator, thus providing significant insight into how cells handle fluctuating signals and noise in their environment.

59 BASIC BIOLOGICAL SCIENCES↗

Laser Doppler anemometer signal processing for blood flow velocity measurements

A new method for analysing the signal in a laser Doppler anemometer based on the differential scheme is proposed, which provides the flow velocity measurement in strongly scattering liquids, particularly, blood. A laser Doppler anemometer intended for measuring the absolute blood flow velocity in animal and human near-surface arterioles and venules is developed. The laser Doppler anemometer signal structure is experimentally studied for measuring the flow velocity in optically inhomogeneous media, such as blood and suspensions of scattering particles. The results of measuring the whole and diluted blood flow velocity in channels with a rectangular cross section are presented. (laser applications and other topics in quantum electronics)

42 ENGINEERING↗

All-optical signal processing at 10 GHz using a photonic crystal molecule

We report on 10 GHz operation of an all-optical gate based on an Indium Phosphide Photonic Crystal Molecule. Wavelength conversion and all-optical mixing of microwave signals are demonstrated using the 2 mW output of a mode locked diode laser. The spectral separation of the optical pump and signal is crucial in suppressing optical cross-talk.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Signal processing to reduce dark noise impact in precision timing

We introduce a technique to mitigate the effects of low frequency noise on precision timing. The example of Dark Count Noise Rate (DCR) in Silicon Photomultipliers (SiPMs) is emphasized. This technique exploits the correlation between time shifts on the leading edge of a signal and the residual slope of the baseline (due to noise) which remains after baseline subtraction. In fast timing applications (such as for Time-of-flight particle ID) the signal arrival time is typically captured on the signal leading edge. The signal risetime is often fixed by the physics of the sensor and input circuit. Then accurate pulse timing can be achieved by correcting a leading edge threshold time (depending on a slope proportional to both the Amplitude and the risetime) to a “constant fraction” time. This compensation for time walk due to amplitude fluctuations breaks down once we introduce interference from low frequency noise on the leading edge. In this paper we demonstrate that an additional measurement of the slope at threshold can be used to correct for this noise jitter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New signal processing technique for density profile reconstruction using reflectometry

Reflectometry profile measurement requires an accurate determination of the plasma reflected signal. Along with a good resolution and a high signal to noise ratio of the phase measurement, adequate data analysis is required. A new data processing based on time-frequency tomographic representation is used. It provides a clearer separation between multiple components and improves isolation of the relevant signals. In this paper, this data processing technique is applied to two sets of signals coming from two different reflectometer devices used on the Tore Supra tokamak. For the standard density profile reflectometry, it improves the initialization process and its reliability, providing a more accurate profile determination in the far scrape-off layer with density measurements as low as 10{sup 16} m{sup -1}. For a second reflectometer, which provides measurements in front of a lower hybrid launcher, this method improves the separation of the relevant plasma signal from multi-reflection processes due to the proximity of the plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear test ban treaty verification: Improving test ban monitoring with empirical and model-based signal processing

In this approach, small scale-length medium perturbations not modeled in the tomographic inversion might be described as random fields, characterized by particular distribution functions (e.g., normal with specified spatial covariance). Conceivably, random field parameters (scatterer density or scale length) might themselves be the targets of tomographic inversions of the scattered wave field. As a result, such augmented models may provide processing gain through the use of probabilistic signal sub spaces rather than deterministic waveforms.

42 ENGINEERING↗

Bistatic SAR: Signal Processing and Image Formation.

This report describes the significant processing steps that were used to take the raw recorded digitized signals from the bistatic synthetic aperture RADAR (SAR) hardware built for the NCNS Bistatic SAR project to a final bistatic SAR image. In general, the process steps herein are applicable to bistatic SAR signals that include the direct-path signal and the reflected signal. The steps include preprocessing steps, data extraction to for a phase history, and finally, image format. Various plots and values will be shown at most steps to illustrate the processing for a bistatic COSMO SkyMed collection gathered on June 10, 2013 on Kirtland Air Force Base, New Mexico.

Wahl, Daniel E.↗

Liquid argon TPC signal formation, signal processing and reconstruction techniques

This document describes a reconstruction chain that was developed for the ArgoNeuT and MicroBooNE experiments at Fermilab. These experiments study accelerator neutrino interactions that occur in a Liquid Argon Time Projection Chamber. Reconstructing the properties of particles produced in these interactions benefits from the knowledge of the micro-physics processes that affect the creation and transport of ionization electrons to the readout system. A wire signal deconvolution technique was developed to convert wire signals to a standard form for hit reconstruction, to remove artifacts in the electronics chain and to remove coherent noise. A unique clustering algorithm reconstructs line-like trajectories and vertices in two dimensions which are then matched to create of 3D objects. In conclusion, these techniques and algorithms are available to all experiments that use the LArSoft suite of software.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In vivo electroretinographic studies of the role of GABA C receptors in retinal signal processing

The retina expresses all three classes of receptors for the inhibitory neurotransmitter GABA (GABAR). Our study investigated roles of GABAR, especially GABA(C)R (GABA(A)-rho), in retinal signaling in vivo by studying effects on the mouse electroretinogram (ERG) of genetic deletion of GABA(C)R versus pharmacological blockade using receptor antagonists. Brief full-field flash ERGs were recorded from anesthetized GABA(C)R(-/-) mice, and WT C57BL/6 (B6) mice, before and after intravitreal injection of GABA(C)R antagonists, TPMPA, 3-APMPA, or the more recently developed 2-AEMP; GABA(A)R antagonist, SR95531; GABA(B)R antagonist, CGP, and agonist, baclofen. Intravitreal injections of TPMPA and SR95531 were also made in Brown Norway rats. The effect of 2-AEMP on GABA-induced current was tested directly in isolated rat rod bipolar cells, and 2-AEMP was found to preferentially block GABA(C)R in those cells. Maximum amplitudes of dark (DA) and light-adapted (LA) ERG b-waves were reduced in GABA(C)R(-/-) mice, compared to B6 mice, by 30-60%; a-waves were unaltered and oscillatory potential amplitudes were increased. In B6 mice, after injection of TPMPA (also in rats), 3-APMPA or 2-AEMP, ERGs became similar to ERGs of GABA(C)R(-/-) mice. Blockade of GABA(A)Rs and GABA(B)Rs, or agonism of GABA(B)Rs did not alter B6 DA b-wave amplitude. Furthermore, the negative scotopic threshold response (nSTR) was slightly less sensitive in GABA(C)R(-/-) than in B6 mice, and unaltered by 2-AEMP. However, amplitudes of nSTR and photopic negative response (PhNR), both of which originate from inner retina, were enhanced by TPMPA and 3-APMPA, each of which has GABA(B) agonist properties, and further increased by baclofen. The finding that genetic deletion of GABA(C)R, the GABA(C)R antagonist 2-AEMP, and other antagonists all reduced ERG b-wave amplitude, supports a role for CABA(C)R in determining the maximum response amplitude of bipolar cells contributing to the b-wave. GABA(C)R antagonists differed in their effects on nSTR and PhNR; antagonists with GABA(B) agonist properties enhanced light-driven responses whereas 2-AEMP did not.

59 BASIC BIOLOGICAL SCIENCES↗

Towards single-chip radiofrequency signal processing via acoustoelectric electron–phonon interactions

Abstract The addition of active, nonlinear, and nonreciprocal functionalities to passive piezoelectric acoustic wave technologies could enable all-acoustic and therefore ultra-compact radiofrequency signal processors. Toward this goal, we present a heterogeneously integrated acoustoelectric material platform consisting of a 50 nm indium gallium arsenide epitaxial semiconductor film in direct contact with a 41° YX lithium niobate piezoelectric substrate. We then demonstrate three of the main components of an all-acoustic radiofrequency signal processor: passive delay line filters, amplifiers, and circulators. Heterogeneous integration allows for simultaneous, independent optimization of the piezoelectric-acoustic and electronic properties, leading to the highest performing surface acoustic wave amplifiers ever developed in terms of gain per unit length and DC power dissipation, as well as the first-ever demonstrated acoustoelectric circulator with an isolation of 46 dB with a pulsed DC bias. Finally, we describe how the remaining components of an all-acoustic radiofrequency signal processor are an extension of this work.

36 MATERIALS SCIENCE↗

DETECTION OF SIGNALS FROM COSMIC REIONIZATION USING RADIO INTERFEROMETRIC SIGNAL PROCESSING

Observations of the H I 21 cm transition line promises to be an important probe into the cosmic dark ages and epoch of reionization. One of the challenges for the detection of this signal is the accuracy of the foreground source removal. This paper investigates the extragalactic point source contamination and how accurately the bright sources (approx>1 Jy) should be removed in order to reach the desired rms noise and be able to detect the 21 cm transition line. Here, we consider position and flux errors in the global sky model for these bright sources as well as the frequency independent residual calibration errors. The synthesized beam is the only frequency dependent term included here. This work determines the level of accuracy for the calibration and source removal schemes and puts forward constraints for the design of the cosmic reionization data reduction scheme for the upcoming low frequency arrays such as, Murchison Widefield Array, Precision Array to Probe Epoch of Reionization, etc. We show that in order to detect the reionization signal the bright sources need to be removed from the data sets with a positional accuracy of approx0.1 arcsec. Our results also demonstrate that the efficient foreground source removal strategies can only tolerate a frequency independent antenna based mean residual calibration error of approx<0.2% in amplitude or approx<0.{sup 0}2 in phase, if they are constant over each days of observations (6 hr). In future papers, we will extend this analysis to the power-spectral domain and also include the frequency-dependent calibration errors and direction-dependent errors (ionosphere, primary beam, etc.).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Innovative signal processing for Johnson Noise thermometry

This report summarizes the newly developed algorithm that subtracted the Electromagnetic Interference (EMI). The EMI performance is very important to this measurement because any interference in the form on pickup from external signal sources from such as fluorescent lighting ballasts, motors, etc. can skew the measurement. Two methods of removing EMI were developed and tested at various locations. This report also summarizes the testing performed at different facilities outside Oak Ridge National Laboratory using both EMI removal techniques. The first EMI removal technique reviewed in previous milestone reports and therefore this report will detail the second method.

97 MATHEMATICS AND COMPUTING↗

Time reversal signal processing for communication.

Time-reversal is a wave focusing technique that makes use of the reciprocity of wireless propagation channels. It works particularly well in a cluttered environment with associated multipath reflection. This technique uses the multipath in the environment to increase focusing ability. Time-reversal can also be used to null signals, either to reduce unintentional interference or to prevent eavesdropping. It does not require controlled geometric placement of the transmit antennas. Unlike existing techniques it can work without line-of-sight. We have explored the performance of time-reversal focusing in a variety of simulated environments. We have also developed new algorithms to simultaneously focus at a location while nulling at an eavesdropper location. We have experimentally verified these techniques in a realistic cluttered environment.

99 GENERAL AND MISCELLANEOUS↗