Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal enhancement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Super-resolution stimulated X-ray Raman spectroscopy

Propagation of intense X-ray pulses through dense media has led to the observation of phenomena such as atomic X-ray lasing, self-induced transparency and stimulated X-ray Raman scattering (SXRS)4. SXRS has been long predicted as a means to launch and probe valence-electron wavepackets and as a building block for nonlinear X-ray spectroscopies. However, experimental observations of SXRS to date have not provided spectroscopic information, and theoretical modelling has largely implemented hard-to-realize phase-coherent attosecond pulses. Here we demonstrate SXRS with spectroscopic precision, that is, detection of valence-excited states in neon with a near Fourier-limited joint energy–time resolution of 0.1 eV–40 fs. We used a new covariance analysis between statistically spiky broadband incident X-ray and scattered X-ray Raman pulses. Using 18,000 single shots, we beat not only the incident (about 8 eV) bandwidth but also the approximately 0.2 eV instrumental energy resolution, thus creating super-resolution conditions, in analogy to super-resolved fluorescence microscopy. Our experimental results, supported by ab initio propagation simulations, reveal the competition between lasing in the ion and stimulated Raman scattering in the neutral. We demonstrate enhanced signal collection efficiency and a broad excitation window, surpassing spontaneous Raman efficiencies by orders of magnitude. This stochastic SXRS approach represents a first step towards tracking elementary events that determine chemical outcomes.

nonlinear x-ray spectroscopy↗

Label-free nanoscopy of cell metabolism by ultrasensitive reweighted visible stimulated Raman scattering

Nanoscopic imaging of cell metabolism is hindered by the incompatibility of small metabolites with fluorescent dyes and the limited resolution of imaging mass spectrometry. We present ultrasensitive reweighted visible stimulated Raman scattering (URV-SRS), a label-free vibrational nanoscopy technique that enables multiplexed detection of metabolic nanostructures within cells. We developed an extensively chirped spectral focusing visible SRS microscope that achieves a detection limit of 4,000 molecules and introduced a self-supervised learning-based denoiser to robustly suppress non-independent SRS noise by over 7.2 dB. The instrumentation-based signal enhancement and computation-based noise suppression synergistically improved the detection sensitivity by 50 times over near-infrared SRS. Leveraging this enhanced sensitivity, we further pushed the resolution to nanoscopic levels by introducing Fourier reweighting to amplify sub-100 nm spatial frequencies previously overwhelmed by noise. Validated by Fourier ring correlation, URV-SRS achieves a lateral resolution of 86 nm in cellular imaging. Here, we applied URV-SRS to elucidate the reprogramming of metabolic nanostructures associated with virus replication in Vero E6 host cells and to compositionally delineate subcellular fatty acid synthesis in engineered Escherichia coli, demonstrating its capability towards nanoscopic spatial metabolomics.

59 BASIC BIOLOGICAL SCIENCES↗

Ultra-low field 13 C MRI of hyperpolarized pyruvate

Medicine is evolving beyond therapy largely predicated on anatomical information and towards incorporating patient-specific molecular biomarkers of disease for more accurate diagnosis and effective treatment. The complementary combination of hyperpolarization by spin-lock induced crossing signal amplification by reversible exchange (SLIC SABRE) and low field magnetic resonance imaging (MRI) can enable accessible metabolic imaging to advance personalized medicine. Hyperpolarized 13 C-enriched pyruvate has demonstrated promise for imaging metabolism in cancer, heart disease and neurodegenerative disorders; however, broader clinical adoption awaits validated clinical indications, and is further constrained by the cost and limited availability of current hyperpolarization technology. Parahydrogen-based polarization techniques, paired with low-cost high-performance MRI at millitesla fields, offer a means of broadening the reach of metabolic imaging. Here we show results demonstrating in situ hyperpolarization of pyruvate at 6.5 mT by SLIC SABRE, followed by immediate readout without field cycling or sample shuttling. We achieve 13 C signal enhancements several million times above thermal equilibrium at 6.5 mT, corresponding to polarization levels of approximately 3%. Leveraging this enhancement, we perform 13 C MRI and acquire NMR spectra with resolution sufficient to distinguish chemical shifts between pyruvate isotopomers. These results show a viable pathway towards accessible metabolic imaging with hyperpolarized 13 C MRI at ultra-low field.

Medical and clinical diagnostics↗

SABRE-SHEATH hyperpolarized 15 N 2 -imidazole for Zn 2+ sensing

Zinc ions are essential for numerous biological functions and activities. Accordingly, Zn 2+ sensors are crucial in biomedical research to understand the role of Zn 2+ in health and disease. Here, we demonstrated the viability of SABRE-SHEATH hyperpolarized 15 N 2 -imidazole, providing an NMR signal enhancement of 45 700 fold (p = 2.15%), as a probe for Zn 2+ sensing by monitoring the Zn-imidazole interaction using NMR and extracted a LOD of 1.3 mM. This study is one of the first demonstrations of SABRE-SHEATH hyperpolarized 15 N as a sensor of other non-hyperpolarized species, which promises chemical sensing without penetration-depth limitations.

Hyperpolarization↗

Pressure-induced 𝐵⁢1 to 𝐵⁢2 phase transition in CeN studied by 𝑎⁢𝑏 𝑖⁢𝑛⁢𝑖⁢𝑡⁢𝑖⁢𝑜 correlation matrix renormalization theory calculations

We apply correlation matrix renormalization theory (CMRT) to cerium nitride (CeN) under pressure. For 𝐵⁢1 (NaCl-type) phase, CMRT gives an equation of state consistent with ambient pressure experiments. It produces electronic density-of-state (DOS) characterized by a sharp 4⁢𝑓 quasiparticle resonance peak pinned at the Fermi level and two subbands formed by strong hybridization between the localized Ce-4⁢𝑓 electrons and the itinerant Ce-5⁢𝑑 and N-2⁢𝑝 electrons below the Fermi level, consistent with x-ray photoemission spectroscopy experiments. Upon compression, CMRT predicts a first-order 𝐵⁢1 → 𝐵⁢2 (CsCl-type) transition with ∼11% volume collapse in agreement with experiments. Across the transition, the 4⁢𝑓 spectrum broadens, the 4⁢𝑓 orbital occupancy increases, and the hybridization with conduction states enhances, signaling a crossover from partially localized to more itinerant 4⁢𝑓 behavior. Furthermore, these features are in excellent agreement with experimental observations, demonstrating that CMRT provides a parameter-free description and prediction of correlation-driven structural and electronic transitions in rare-earth compounds.

Ab initio calculations↗

Pump with Broadband Probe Experiments for Single-Shot Measurements of Plasma Conditions and Crossed-Beam Energy Transfer

Here, a novel technique for measuring plasma conditions using monochromatic pump-broadband-probe laser interactions has been experimentally demonstrated. Originally proposed in Ludwig et al. [Phys. Plasmas 26, 113108 (2019)], this method utilizes crossed-beam energy transfer between the broadband probe and the pump, mediated by plasma ion acoustic waves. The complete energy transfer spectrum can be captured in a single shot, enabling the inference of plasma parameters such as density, electron and ion temperatures, and flow velocity. Compared to Thomson scattering, this technique offers signal enhancements typically larger than 9 orders of magnitude, significantly reducing the required probe laser intensity and facilitating interactions that are linear and measurements that are nonperturbative of the plasma. Furthermore, it provides a powerful tool for advancing studies of crossed-beam energy transfer under conditions relevant to inertial confinement fusion experiments.

Physics - Plasma physics↗

Superconducting quasiparticle-amplifying transmon: A qubit-based sensor for meV-scale phonons and single terahertz photons

With great interest from the quantum computing community, an immense amount of R&D effort has been invested into improving superconducting qubits. The technologies developed for the design and fabrication of these qubits can be directly applied to applications for ultralow-threshold particle detectors, e.g., low-mass dark matter and far-infrared photon sensing. We propose a novel energy-resolving sensor based on the transmon qubit architecture combined with a signal-enhancing superconducting quasiparticle amplification stage. We refer to these sensors as SQUATs: superconducting quasiparticle-amplifying transmons. We detail the operating principle and design of this new sensor and predict that, with minimal R&D effort, solid-state-based detectors patterned with these sensors can achieve sensitivity to single terahertz photons, and sensitivity to 1 meV phonons in the detector absorber substrate on the microsecond timescale. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION↗

Mitigating Electrochemical Impedance Spectroscopy Artifacts in PEMWE Reference Electrode Measurements

This study investigates strategies to improve the quality of electrochemical impedance spectroscopy (EIS) measurements using reference electrodes (RE) in proton exchange membrane water electrolyzers (PEMWE). We demonstrate that adding a low impedance wire in parallel to the RE significantly enhances signal accuracy, especially at high frequencies. Additionally, we identify electrical pad heaters as a source of measurement noise. EIS measurements fulfilling Kramers–Kronig validity criteria were only achieved in their absence. These insights advance the diagnostic capabilities of REs in water electrolyzers and support more reliable, spatially resolved analysis of electrochemical losses within the cell.

08 HYDROGEN↗

Chasing ghosts: characterization of artifact generation in coded aperture decoding due to experimental implementation

Coded aperture imaging is a form of lensless aperture imaging that projects multiple overlapping images of the source onto the detector, enhancing signal strength, which is advantageous for low-flux sources or high-resolution imaging. This technique requires decoding of the detector signal to reconstruct the original source, which involves convolving the detector data with the aperture pattern. When the signal is from a centered point source, the reconstructed source image is known as the point spread function (PSF). A clean PSF without artifacts is a Dirac delta function [Appl. Opt. 20, 1858 (1981)]. This paper examines the robustness of the decoding process against variations in experimental tolerances by analyzing artifact growth in the reconstructed PSF. We illustrate the effects of incorrect magnification, rotation, and detector size and find that aperture–detector rotational misalignment about the imaging axis is the most sensitive parameter, with significant artifact generation occurring with angular offsets of less than one degree. We discuss compensation methods for imperfect aperture placement, finding that small detector sizes produce uncompensatable artifact generation, and compare theoretical predictions with experimental PSF measurements of a rank , 6.8 mm thick (less than one mean free path) coded aperture with a 3.5 mm cell size, conducted at the MegaJOuLe Neutron Imaging Radiography dense plasma focus [IEEE Trans. Plasma Sci. 49, 3299 (2021)] using a 2.45 MeV neutron source. Based on our findings, we recommend using magnified coded apertures in the under-sampled regime, which allows for the inclusion of fiducial markers to characterize aperture–detector rotational offsets and the addition of mechanical coupling, where possible, to constrain rotational and magnification offsets.

Selwood, M. P. [Lawrence Livermore National Labora↗

Seismic Array Analysis Using Fiber-Optic Distributed Acoustic Sensing on Small Local and Regional Earthquakes

We examined the feasibility of using fiber-optic Distributed Acoustic Sensing (DAS) as an alternative to a traditional seismic array. Seismic arrays are used routinely globally to measure waveform propagation parameters and signal features including back-azimuth (BAZ) and apparent horizontal velocity through the process of beamforming or frequency-wavenumber (f-k) array analysis with the assumption that the signals travel across the array as a plane-wave. These measurements are useful for identifying signal detections as teleseismic, regional, or local distance seismic phases based on their velocities traveling across the array (e.g., Rost and Thomas, 2001). Signal enhancement is the main benefit of array processesing through the stacking of multiple channels as a phased array. This enhancement increases as the square root of the number of channels relative to a single seismic station (e.g., Rost and Thomas, 2001), which is a factor of 3 from a typical nine-channel array. DAS provides the potential of stacking waveforms from 100’s to 1000’s of channels. However, DAS is a novel technology designed for geophysical exploration and therefore has some limitations which we will explore. We started with the dataset from the PoroTomo project because of its unique experimental layout of colocated geophone array and DAS deployment so the two recording technologies can be compared side-by-side.

58 GEOSCIENCES↗

Efficiency of ML Anomaly Detection Triggers for Emerging Jets

Novel machine learning-based anomaly detection Level 1 (L1) triggers are currently under development at CMS, namely AXOL1TL and CICADA. The former employs a variational autoencoder, while the latter utilizes a convolutional autoencoder. These triggers aim to balance rate reduction with model independence, enabling the selection of potentially significant events that might be overlooked by traditional triggers relying on basic kinematic variable selections. Consequently, they have the potential to enhance signals indicative of physics beyond the Standard Model, such as those associated with emerging jets. Such signals are predicted by models featuring a composite dark sector where long-lived particles decay into Standard Model jets with displaced tracks and numerous vertices. This study evaluates the efficiency of these anomaly detection triggers in selecting events with emerging jets produced via the s-channel production of two dark quarks.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Digital automatic data reduction techniques used in a 1000-flight biomedical study

Techniques developed to automatically process a large quantity of physiological data obtained during a 1000-flight study are described. To reduce this data reliably, a study program was conducted using physiological data from X-15 flights as a data source for experimenting with signal enhancement and noise elimination techniques. The techniques include an automatic means for counting heart rates, averaging electrocardiogram waveforms, plotting histograms of heart rate versus frequency, and counting respiration rates. These techniques were used to reduce more than 2000 hours of physiological data recorded in flight.

Carpenter, R.↗

Molecular beam simulation of planetary atmospheric entry: Some recent results

Molecular beam sources for producing fast beams containing CO2 and atomic oxygen are discussed. Results pertinent to the design and calibration of mass spectrometer ion source for measurement of the Martian atmosphere during the free molecule portion of the entry trajectory are also presented. The shortcomings and advantages of the simulation technique are discussed. It is shown that an open cavity configuration retains sensitivity to atomic oxygen, provides reasonable signal enhancement from the stagnation effect, is not highly sensitive to pitch and yaw effects, and presents no unforeseen problems in measuring CO2 or atomic oxygen. The simulation techniques used provide assistance in designing, developing, and (potentially) in testing and calibrating the required flight instrument.

French, J. B.↗

Dispersion studies of the 22 GHz water vapor line shape. II - Instrumental correction.

Anomalies in the resonance dispersion of the pressure-broadened water vapor line at a frequency of 22.235 GHz are resolved. The pressure-scanning differential-refraction spectrometer gives rise to a signal enhancement as the line center moves within the width of the dispersion discriminator. Resonance absorption prevents the frequency of peak transmitted power from coinciding with the resonance condition of zero phase. The results reported for the 23.6 GHz rotational line of ethylene oxide show a Lorentzian molecular line shape.

Dillon, T. A.↗

Molecular beam simulation of planetary atmospheric entry - Some recent results.

Progress is reported in the development of molecular beam techniques to simulate entry into planetary atmospheres. Molecular beam sources for producing fast beams containing CO2 and atomic oxygen are discussed. Results pertinent to the design and calibration of a mass spectrometer ion source for measurement of the Martian atmosphere during the free molecule portion of the entry trajectory are also presented. The shortcomings and advantages of this simulation technique are discussed, and it is demonstrated that even with certain inadequacies much information useful to the ion source design was obtained. Particularly, it is shown that an open-cavity configuration retains sensitivity to atomic oxygen, provides reasonable signal enhancement from the stagnation effect, is not highly sensitive to pitch and yaw effects, and presents no unforeseen problems in measuring CO2 or atomic oxygen.

French, J. B.↗

Reduction of losses in low-frequency /2 MHz/ surface-wave delay line by outgassing

Surface waves are attenuated by a fluid or gas surrounding the surface of propagation, an effect caused by frictional losses determined by the fluid or gas viscosity and by the emission of compression waves into the environment. The paper reports a large reversible reduction in attenuation of surface waves at frequencies as low as 2 MHz by outgassing treatments of some materials, suggesting that at such frequencies vacuum encapsulation is a desirable procedure. Outgassing experiments were performed on a delay line constructed from high-density p.z.t.-8 (lead-zirconate-titanate). The delay line configuration was a slab waxed onto a metal base with coaxial connectors mounted near and connected by gold-wire leads to the interdigital finger sets. Output signal enhancements by as much as 8 dB were achieved after overnight evacuation at 10 to the -2 torr at room temperature.

Tittmann, B. R.↗

Improved methods for fan sound field determination

Several methods for determining acoustic mode structure in aircraft turbofan engines using wall microphone data were studied. A method for reducing data was devised and implemented which makes the definition of discrete coherent sound fields measured in the presence of engine speed fluctuation more accurate. For the analytical methods, algorithms were developed to define the dominant circumferential modes from full and partial circumferential arrays of microphones. Axial arrays were explored to define mode structure as a function of cutoff ratio, and the use of data taken at several constant speeds was also evaluated in an attempt to reduce instrumentation requirements. Sensitivities of the various methods to microphone density, array size and measurement error were evaluated and results of these studies showed these new methods to be impractical. The data reduction method used to reduce the effects of engine speed variation consisted of an electronic circuit which windowed the data so that signal enhancement could occur only when the speed was within a narrow range.

Cicon, D. E.↗

Rotor wake characteristics relevant to rotor-stator interaction noise generation

Mean and turbulent wake properties at three axial locations behind the rotor of an aerodynamically loaded 1.2 pressure ratio fan were measured using a stationary cross film anemometer in an anechoic wind tunnel. Wake characteristics at four radial immersions across the duct at four different fan speeds were determined utilizing a signal enhancement technique. The shapes of the waveforms of the mean rotor relative and mean upwash velocities were shown to change significantly across the span of the blades. In addition, an increase in fan rotational speed caused an increase in the maximum wake turbulence intensity levels near the hub and tip. Spectral analysis was used to described the complex nature of the rotor wake.

Shaw, L. M.↗