Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Serialization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

3-D reconstruction and microstructural characterization of neutron-irradiated U-10Zr fuel using FIB-SEM serial sectioning

Herein, focused ion beam-scanning electron microscopy serial sectioning was applied to characterize the three-dimensional (3-D) porosity and phase regions of a neutron-irradiated U-10 wt% Zr fuel. The specimen was removed from an intermediate radial region of a fuel pin irradiated to 5.7 at.% burn-up. Backscattered electron imaging and energy-dispersive spectroscopy were performed on each serial section, allowing for the characterization of microstructural morphology and composition. Porosity size followed a lognormal distribution, ranging from 1.46 × 10 –4 to 25.58 µm 3 with a total porosity volume fraction of 13.02%. Distinctive microstructural regions were identified by composition and porosity: (1) a Zr-rich region with an average composition of 28.4 wt% Zr and a local porosity fraction of 6.88%, and (2) a U-rich region with an average composition of 97.0 wt% U and a local porosity fraction of 14.11%; subdivided into U-rich—high porosity (16.68%) and U-rich—low porosity (8.04%) regions. The detailed 3-D compositional and porosity regions can improve nuclear fuel performance codes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multi-static Serial LiDAR for Surveillance and Identification of Marine Life at MHK Installations

Final Report for project DE-EE0006787: Multi-static Serial LiDAR for Surveillance and Identification of Marine Life at MHK Installations. This project developed and tested an optical monitoring system prototype that will be suitable for marine and hydrokinetic (MHK) full project lifecycle observation (baseline, commissioning, and decommissioning), with automated real-time classification of marine animals. This system can be deployed to collect pre-installation baseline species observations at a proposed deployment site with minimal post-processing overhead. To satisfy deployed MHK project species of concern (e.g. Endangered Species Act-listed) monitoring requirements, the system provides automated tracking and notification of the presence of managed animals within established perimeters of MHK equipment and provides high resolution imagery of their behavior through a wide range of conditions. During a project’s decommissioning stage, the system can remain installed to provide resource managers with post-installation data. Our technology, known as an Unobtrusive Multi-static Serial LiDAR Imager (UMSLI), is a technology transfer of underwater distributed LiDAR imaging technology that preserves the advantages of traditional optical and acoustic solutions while overcoming associated disadvantages for MHK environmental monitoring applications. This new approach is a purposefully-designed, reconfigurable adaptation of an existing technology that can be easily mounted on or around different classes of MHK equipment. The system uses low average power red (638nm) laser illumination to be invisible and eye-safe to marine animals and is compact and cost effective. The equipment is designed for long term, maintenance-free operations, to inherently generate a sparse primary dataset that only includes detected anomalies (animal presence information), and to allow robust real-time automated animal classification/identification with a low data bandwidth requirement. Advantages of the technology over others currently being used or being considered for MHK monitoring include: Unlike a conventional camera, the depth of field is near-infinite and limited by attenuation (approximately 5-8 m) rather than focal properties of a lens; Operation in an adaptive mode which can project a sparse grid of pulses with higher peak power for longer range detection (>10 meters) and track animals within a zone of interest with high resolution imagery for identification of marine life at closer range (<5m); System detection limit and Signal-to-Noise-Ratio is superior to a camera, due to rejection of both backscattering component and ambient solar background; Multiple wide-angle pulsed laser illuminators and bucket detectors can be flexibly configured to cover a 4pi steradian (i.e. omnidirectional) scene volume, while also retrieving 3D features of animal targets from timing information; Process and classification framework centered around a novel active learning and incremental classification classifier that enables accurate identification of a variety of marine animals automatically; A two-tiered monitoring architecture and invisible watermarking-based data archiving and retrieving approach ensures significant data reduction while preserving high fidelity monitoring. A methodology to train and optimize the classifier for target species of concern to optimize site monitoring effectiveness. This technological innovation addresses a high priority regulatory requirement to observe marine life interaction near MHK projects. Our solution improves resource manager confidence that any interactions between marine animals and equipment are observed in a cost-effective and automated manner. Without EERE funding, this novel application of multi-static LiDAR would not have been available to the MHK community for environmental monitoring.

16 TIDAL AND WAVE POWER↗

Humidified sample preparation station for serial crystallography

Humidified sample preparation station for serial crystallography according to one embodiment is a humidified enclosure that delivers relative humidities above 95% and preferably above 97% in standard operation, and that can allow microscope observation of samples within. Humidified sample preparation station for serial crystallography can be used for preparation of protein crystal samples for examination using X-rays and for protein structure determination by X-ray crystallography, involving addition of liquid to the sample and removal of liquid from the sample using vacuum or suction.

Jayne, Richard↗

High-viscosity injector-based pink-beam serial crystallography of microcrystals at a synchrotron radiation source

Since the first successful serial crystallography (SX) experiment at a synchrotron radiation source, the popularity of this approach has continued to grow showing that third-generation synchrotrons can be viable alternatives to scarce X-ray free-electron laser sources. Synchrotron radiation flux may be increased ∼100 times by a moderate increase in the bandwidth (`pink beam' conditions) at some cost to data analysis complexity. Here, we report the first high-viscosity injector-based pink-beam SX experiments. The structures of proteinase K (PK) and A 2A adenosine receptor (A 2A AR) were determined to resolutions of 1.8 and 4.2 Å using 4 and 24 consecutive 100 ps X-ray pulse exposures, respectively. Strong PK data were processed using existing Laue approaches, while weaker A 2A AR data required an alternative data-processing strategy. This demonstration of the feasibility presents new opportunities for time-resolved experiments with microcrystals to study structural changes in real time at pink-beam synchrotron beamlines worldwide.

36 MATERIALS SCIENCE↗

Integrated sample-handling and mounting system for fixed-target serial synchrotron crystallography

Serial synchrotron crystallography (SSX) is enabling the efficient use of small crystals for structure–function studies of biomolecules and for drug discovery. An integrated SSX system has been developed comprising ultralow background-scatter sample holders suitable for room and cryogenic temperature crystallographic data collection, a sample-loading station and a humid `gloveless' glovebox. The sample holders incorporate thin-film supports with a variety of designs optimized for different crystal-loading challenges. These holders facilitate the dispersion of crystals and the removal of excess liquid, can be cooled at extremely high rates, generate little background scatter, allow data collection over >90° of oscillation without obstruction or the risk of generating saturating Bragg peaks, are compatible with existing infrastructure for high-throughput cryocrystallography and are reusable. The sample-loading station allows sample preparation and loading onto the support film, the application of time-varying suction for optimal removal of excess liquid, crystal repositioning and cryoprotection, and the application of sealing films for room-temperature data collection, all in a controlled-humidity environment. The humid glovebox allows microscope observation of the sample-loading station and crystallization trays while maintaining near-saturating humidities that further minimize the risks of sample dehydration and damage, and maximize working times. This integrated system addresses common problems in obtaining properly dispersed, properly hydrated and isomorphous microcrystals for fixed-orientation and oscillation data collection. Its ease of use, flexibility and optimized performance make it attractive not just for SSX but also for single-crystal and few-crystal data collection. Fundamental concepts that are important in achieving desired crystal distributions on a sample holder via time-varying suction-induced liquid flows are also discussed.

47 OTHER INSTRUMENTATION↗

A Framework for Closed-Loop Optimization of an Automated Mechanical Serial-Sectioning System via Run-to-Run Control as Applied to a Robo-Met.3D

Optimization of automated data collection is gaining increased interest for the purposes of enabling closed-loop self-correcting systems that inherently maximize operational efficiencies and reduce waste. Many data collection systems have several variables which influence data accuracy or consistency and which can require frequent user interaction to be monitored and maintained. Operating upon a Robo-MET.3D™ automated mechanical serial-sectioning system, a run-to-run control algorithm has been developed to accelerate data collection and reduce data inconsistency. Here, using historical data amassed over a decade of experiments, a linear regression model of the deterministic system dynamics is created and used to employ a run-to-run control algorithm that optimizes selected system inputs to reduce operator intervention and increase efficacy while reducing variance of system output.

42 ENGINEERING↗

3D Reconstruction of a High-Energy Diffraction Microscopy Sample Using Multi-modal Serial Sectioning with High-Precision EBSD and Surface Profilometry

High-energy diffraction microscopy (HEDM) combined with in situ mechanical testing is a powerful nondestructive technique for tracking the evolving microstructure within polycrystalline materials during deformation. This technique relies on a sophisticated analysis of X-ray diffraction patterns to produce a three-dimensional reconstruction of grains and other microstructural features within the interrogated volume. However, it is known that HEDM can fail to identify certain microstructural features, particularly smaller grains or twinned regions. Characterization of the identical sample volume using high-resolution surface-specific techniques, particularly electron backscatter diffraction (EBSD), can not only provide additional microstructure information about the interrogated volume but also highlight opportunities for improvement of the HEDM reconstruction algorithms. In this study, a sample fabricated from undeformed “low solvus, high refractory” nickel-based superalloy was scanned using HEDM. The volume interrogated by HEDM was then carefully characterized using a combination of surface-specific techniques, including epi-illumination optical microscopy, zero-tilt secondary and backscattered electron imaging, scanning white light interferometry, and high-precision EBSD. Custom data fusion protocols were developed to integrate and align the microstructure maps captured by these surface-specific techniques and HEDM. The raw and processed data from HEDM and serial sectioning have been made available via the Materials Data Facility (MDF) at https://doi.org/10.18126/4y0p-v604 for further investigation.

36 MATERIALS SCIENCE↗

A Robust Data-Driven Approach for Mechanical Serial Sectioning

Mechanical serial sectioning (MSS) provides detailed microstructural information across large length scales. By repeatedly removing thin layers of material and imaging the exposed surface, a 3D representation of a specimen’s internal structure can be constructed, enabling failure analysis and feature identification that are otherwise inaccessible via conventional 2D or nondestructive evaluation techniques. Achieving consistent and accurate material removal can be challenging due to system variability, requiring an experienced operator to manually adjust parameters, prolonging data collection times and necessitating post-processing routines to standardize the data. Here, to address these challenges, this paper presents the employment of a one-step model predictive control (MPC) framework tailored to a run-to-run (R2R) controller. The R2R-MPC controller automates the parameter selection process, improving the consistency of material removal through iterative feedback for disturbance rejection and accurate tracking of the target removal rate. Using a data-driven approach, the controller robustly adapts to changing material characteristics. The effectiveness of the R2R-MPC controller is demonstrated through simulation and experimental results and compared to previous data collection procedures.

3D Materials Science↗

All-alumina quarter-wave plate coatings fabricated by glancing angle deposition using serial bideposition

Anisotropic phase retarders, used in high power laser facilities to perform polarization smoothing, can be obtained by the glancing angle deposition (GLAD) coating process. Due to its high laser resistance, the coatings are mainly made of silica. Therefore, limited attention has been given to other dielectric materials. Here we present a study on alumina GLAD anisotropic coatings; a material with high laser resistance, higher birefringence and lower environmental sensitivity than silica. Since the anisotropy is related to the coatings microstructure through the deposition angle, samples were coated at angles varying from ± 68° to ± 82° using the serial bideposition technique. They were characterized by ellipsometry, polarimetry, spectrophotometry and electron microscopy. We showed that the highest birefringence is obtained at a deposition angle of ± 76° with an in-plane value of 0.053. Based on these results, a quarter-wave plate at 351 nm was designed as a multilayer with seven pairs of anisotropic layers deposited at ± 76° and isotropic layers deposited at 0°. The fabricated coating exhibited a uniform retardance of 88.51 ± 0.45 nm. The alumina GLAD wave plates presented here, open the door to new possibilities in the laser field and especially in the field of fusion energy.

36 MATERIALS SCIENCE↗

3D microstructure reconstruction of casting aluminum alloy based on serial block-face scanning electron microscopy

In this work, the inner microstructure of aluminum-silicon casting alloy was experimentally investigated to reveal the spatial morphology and phase distribution. Its industrial use is as a light-weight structural material. As a powerful three-dimensional (3D) imaging tool at the nano-scale, the serial block-face scanning electron microscopy (SBFSEM) was employed to investigate the specimens. After being 3D reconstructed, the images were visualized to identify preference for several specific intermetallics by quantitative analysis. It was found that these phases have certain relationships in spatial distribution and differences in spatial shapes. In conclusion, the spatial distribution of cracks was studied to understand their propagation and growth.

3D microstructure reconstruction↗

Crystal structure of CO-bound cytochrome c oxidase determined by serial femtosecond X-ray crystallography at room temperature

Here, cytochrome c oxidase (C c O), the terminal enzyme in the electron transfer chain, translocates protons across the inner mitochondrial membrane by harnessing the free energy generated by the reduction of oxygen to water. Several redox-coupled proton translocation mechanisms have been proposed, but they lack confirmation, in part from the absence of reliable structural information due to radiation damage artifacts caused by the intense synchrotron radiation. Here we report the room temperature, neutral pH (6.8), damage-free structure of bovine C c O (bC c O) in the carbon monoxide (CO)-bound state at a resolution of 2.3 Å, obtained by serial femtosecond X-ray crystallography (SFX) with an X-ray free electron laser. As a comparison, an equivalent structure was obtained at a resolution of 1.95 Å, from data collected at a synchrotron light source. In the SFX structure, the CO is coordinated to the heme a3 iron atom, with a bent Fe–C–O angle of ~142°. In contrast, in the synchrotron structure, the Fe–CO bond is cleaved; CO relocates to a new site near Cu B , which, in turn, moves closer to the heme a 3 iron by ~0.38 Å. Structural comparison reveals that ligand binding to the heme a 3 iron in the SFX structure is associated with an allosteric structural transition, involving partial unwinding of the helix-X between heme a and a 3 , thereby establishing a communication linkage between the two heme groups, setting the stage for proton translocation during the ensuing redox chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

2'-O methylation of RNA cap in SARS-CoV-2 captured by serial crystallography

The genome of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) coronavirus has a capping modification at the 5'-untranslated region (UTR) to prevent its degradation by host nucleases. These modifications are performed by the Nsp10/14 and Nsp10/16 heterodimers using S-adenosylmethionine as the methyl donor. Nsp10/16 heterodimer is responsible for the methylation at the ribose 2'-O position of the first nucleotide. To investigate the conformational changes of the complex during 2'-O methyltransferase activity, we used a fixed-target serial synchrotron crystallography method at room temperature. We determined crystal structures of Nsp10/16 with substrates and products that revealed the states before and after methylation, occurring within the crystals during the experiments. Here we report the crystal structure of Nsp10/16 in complex with Cap-1 analog ( m7 GpppA m2'-O ). Inhibition of Nsp16 activity may reduce viral proliferation, making this protein an attractive drug target.

59 BASIC BIOLOGICAL SCIENCES↗

3D printed droplet generation devices for serial femtosecond crystallography enabled by surface coating

The role of surface wetting properties and their impact on the performance of 3D printed microfluidic droplet generation devices for serial femtosecond crystallography (SFX) are reported herein. SFX is a novel crystallography method enabling structure determination of proteins at room temperature with atomic resolution using X-ray free-electron lasers (XFELs). In SFX, protein crystals in their mother liquor are delivered and intersected with a pulsed X-ray beam using a liquid jet injector. Owing to the pulsed nature of the X-ray beam, liquid jets tend to waste the vast majority of injected crystals, which this work aims to overcome with the delivery of aqueous protein crystal suspension droplets segmented by an oil phase. For this purpose, 3D printed droplet generators that can be easily customized for a variety of XFEL measurements have been developed. The surface properties, in particular the wetting properties of the resist materials compatible with the employed two-photon printing technology, have so far not been characterized extensively, but are crucial for stable droplet generation. This work investigates experimentally the effectiveness and the long-term stability of three different surface treatments on photoresist films and glass as models for our 3D printed droplet generator and the fused silica capillaries employed in the other fluidic components of an SFX experiment. Finally, the droplet generation performance of an assembly consisting of the 3D printed device and fused silica capillaries is examined. Stable and reproducible droplet generation was achieved with a fluorinated surface coating which also allowed for robust downstream droplet delivery. Experimental XFEL diffraction data of crystals formed from the large membrane protein complex photosystem I demonstrate the full compatibility of the new injection method with very fragile membrane protein crystals and show that successful droplet generation of crystal-laden aqueous droplets intersected by an oil phase correlates with increased crystal hit rates.

47 OTHER INSTRUMENTATION↗

Pattern-matching indexing of Laue and monochromatic serial crystallography data for applications in materials science

Serial crystallography data can be challenging to index, as each frame is processed individually, rather than being processed as a whole like in conventional X-ray single-crystal crystallography. An algorithm has been developed to index still diffraction patterns arising from small-unit-cell samples. The algorithm is based on the matching of reciprocal-lattice vector pairs, as developed for Laue microdiffraction data indexing, combined with three-dimensional pattern matching using a nearest-neighbors approach. As a result, large-bandpass data (e.g. 5–24 keV energy range) and monochromatic data can be processed, the main requirement being prior knowledge of the unit cell. Furthermore, angles calculated in the vicinity of a few theoretical and experimental reciprocal-lattice vectors are compared, and only vectors with the highest number of common angles are selected as candidates to obtain the orientation matrix. Global matching on the entire pattern is then checked. Four indexing options are available, two for the ranking of the theoretical reciprocal-lattice vectors and two for reducing the number of possible candidates. Furthermore, the algorithm has been used to index several data sets collected under different experimental conditions on a series of model samples. Additionally, knowing the crystallographic structure of the sample and using this information to rank the theoretical reflections based on the structure factors helps the indexing of large-bandpass data for the largest-unit-cell samples. For small-bandpass data, shortening the candidate list to determine the orientation matrix should be based on matching pairs of reciprocal-lattice vectors instead of triplet matching.

36 MATERIALS SCIENCE↗

Co-flow injection for serial crystallography at X-ray free-electron lasers

Serial femtosecond crystallography (SFX) is a powerful technique that exploits X-ray free-electron lasers to determine the structure of macromolecules at room temperature. Despite the impressive exposition of structural details with this novel crystallographic approach, the methods currently available to introduce crystals into the path of the X-ray beam sometimes exhibit serious drawbacks. Samples requiring liquid injection of crystal slurries consume large quantities of crystals (at times up to a gram of protein per data set), may not be compatible with vacuum configurations on beamlines or provide a high background due to additional sheathing liquids present during the injection. Proposed and characterized here is the use of an immiscible inert oil phase to supplement the flow of sample in a hybrid microfluidic 3D-printed co-flow device. Co-flow generation is reported with sample and oil phases flowing in parallel, resulting in stable injection conditions for two different resin materials experimentally. A numerical model is presented that adequately predicts these flow-rate conditions. The co-flow generating devices reduce crystal clogging effects, have the potential to conserve protein crystal samples up to 95% and will allow degradation-free light-induced time-resolved SFX.

3D printing↗

Characterization and use of the spent beam for serial operation of LCLS

X-ray free-electron laser sources such as the Linac Coherent Light Source offer very exciting possibilities for unique research. However, beam time at such facilities is very limited and in high demand. This has led to significant efforts towards beam multiplexing of various forms. One such effort involves re-using the so-called spent beam that passes through the hole in an area detector after a weak interaction with a primary sample. This beam can be refocused into a secondary interaction region and used for a second, independent experiment operating in series. The beam profile of this refocused beam was characterized for a particular experimental geometry at the Coherent X-ray Imaging instrument at LCLS. A demonstration of this multiplexing capability was performed with two simultaneous serial femtosecond crystallography experiments, both yielding interpretable data of sufficient quality to produce electron density maps.

43 PARTICLE ACCELERATORS↗

Serial crystallography using automated drop dispensing

Automated, pulsed liquid-phase sample delivery has the potential to greatly improve the efficiency of both sample and photon use at pulsed X-ray facilities. In this work, an automated drop on demand (DOD) system that accelerates sample exchange for serial femtosecond crystallography (SFX) is demonstrated. Four different protein crystal slurries were tested, and this technique is further improved here with an automatic sample-cycling system whose effectiveness was verified by the indexing results. Here, high-throughput SFX screening is shown to be possible at free-electron laser facilities with very low risk of cross contamination and minimal downtime. The development of this technique will significantly reduce sample consumption and enable structure determination of proteins that are difficult to crystallize in large quantities. This work also lays the foundation for automating sample delivery.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fixed-target serial crystallography at the Structural Biology Center

Serial synchrotron crystallography enables the study of protein structures under physiological temperature and reduced radiation damage by collection of data from thousands of crystals. The Structural Biology Center at Sector 19 of the Advanced Photon Source has implemented a fixed-target approach with a new 3D-printed mesh-holder optimized for sample handling. The holder immobilizes a crystal suspension or droplet emulsion on a nylon mesh, trapping and sealing a near-monolayer of crystals in its mother liquor between two thin Mylar films. Data can be rapidly collected in scan mode and analyzed in near real-time using piezoelectric linear stages assembled in an XYZ arrangement, controlled with a graphical user interface and analyzed using a high-performance computing pipeline. Here, the system was applied to two β-lactamases: a class D serine β-lactamase from Chitinophaga pinensis DSM 2588 and L1 metallo-β-lactamase from Stenotrophomonas maltophilia K279a.

59 BASIC BIOLOGICAL SCIENCES↗