Testing of Heat Flux Sensors at Cryogenic Temperatures

Normally, in order to characterize multilayer insulation installed onto a test tank, the boil-off of the tank is measured and then heat loads from structural and fluid penetrations are calculated from temperature measurements throughout the system. For the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig testing, it was determined that this approach would have significant uncertainties (over 50%) and that another method was needed to characterize the heat load through the blanket. Heat flux sensors are widely used to measure heat loads and characterize insulation systems at room temperature, however, the heat fluxes measured are usually two orders of magnitude higher than high performance MLI. Three different heat flux sensors were initially checked out on a liquid hydrogen calorimeter. One was chosen for actual implementation and 20 sensors were ordered. Of those sensors, calibration was attempted on 7 of the sensors. The results from testing and calibration are discussed.

cryogenic fluid management

Improvements in the On-Orbit Response Versus Scan Angle Characterization of the Aqua MODIS Reflective Solar Bands

The Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) has been chosen by the Global Space-based Inter-Calibration System operational community as the reference sensor in cross-sensor calibration. A number of geostationary orbit and low-earth orbit sensors use the 0.64-μm band from Aqua MODIS as a calibration reference. After over 15 years on-orbit, the performance characteristics of the MODIS instrument have changed, with effects evident at short wavelengths. MODIS employs a reflectance-based calibration using the solar diffuser measurements with the monthly lunar observations facilitating a response versus scan angle characterization on-orbit. As the instrument continues to operate beyond its design lifetime of 6 years, the on-board calibrators alone are insufficient to accurately characterize the instrument's response at all scan angles. This results in a long-term reflectance drift, particularly observed in the 0.64- and 0.85-μm bands, while observing the temporally invariant desert sites. Long-term reflectance drifts of up to 2% and 3% are observed at the beginning of scan for the 0.64- and 0.85-μm bands, respectively. An approach using earth-view response to supplement the on-board calibrator measurements has been shown to overcome these inadequacies and is now implemented for the 0.64-, 0.85-, 0.46-, and 0.55-μm land bands of Aqua MODIS. This paper presents the details related to the algorithm implementation and an independent evaluation using the Dome Concordia site and deep-convective clouds. This approach has been reviewed, tested, and approved by the MODIS science team and has been implemented in the forward production of the MODIS L1B Collection 6 starting July 9, 2016. This enhanced approach has also been adopted in the MODIS L1B Collection 6.1 reprocess for the entire mission to facilitate an improved quality of downstream science products. The results with the enhanced approach reduce the reflectance drifts to within 0.5% for most cases.

Angal, Amit

Radiometric Calibration of the AWiFS Sensor and a Cross-calibration Enhanced Vicarious Calibration Technique

Using vicarious calibration validation of moderate resolution sensors such as AWiFS is complicated by requiring more land area to ensure proper registration and sufficient pixel numbers. A trial AWiFS calibration was performed on a grass site that consisted of two dramatically different grass heights. Ground truth data was collected over relatively small areas representing only a few pixels. The radiometric gain results for each of these areas will be reported. To enhance this analysis, since a near coincidence high resolution image was collected, the high resolution data was effectively resized to produce pixels comparable to AWiFS and the atmospheric model was used to produce a top of canopy radiance map. Multiple uniform vegetated areas of several radiances were then identified and subsequently propagated to the top of atmosphere viewpoint of the moderate resolution (AWiFS) satellite. The radiometric gain was then calculated based on the vendor high resolution satellite gains (for the 3 bands with comparable wavelengths). Band-to-band conversion was performed assuming a hyperspectral reflectance based on the standard vegetated site. The initial comparison produces AWiFS radiometric gain values that agree to better than 10% of the values measured using the standard vicarious gain technique.

Aaron, David

TPSAS-NF1676L-16988-DND

There has been renewed interest to uniformly recalibrate historical geostationary (GEO) data records to aid in climate monitoring. GEO sensors have annual repeatable angular sampling over a given location. The view angle is fixed and the imaging schedule is usually constant through its lifetime. Given the fact that colocated GEOs are always share the same sub-satellite point and maintain their imaging schedules provides repeatable angular sampling over decades. One of the biggest challenges in transferring a reference sensor calibration using invariant desert targets to another sensor is the accuracy of the bidirectional reflectance distribution function (BDRF). A well-calibrated GEO can be used to predict the daily exoatmospheric radiance model (DERM) over a desert target for a given GMT that is valid for any GEO sensor at the same location. The advantage of this method is that a BRDF is not needed. Another challenge of invariant target calibration is the unique spectra signature of the desert. However, since most GEOs are built in batches, the spectral response functions (SRF) are very similar for most historical GEOs, the spectral band adjustment factor (SBAF) between GEO sensors is much smaller than for MODIS and GEO sensors. Since the water vapor burden over the desert is seasonal, both the TOA and desert surface can be considered invariant for a given day of the year. The reference GEO can be inter-calibrated with MODIS or VIIRS, which have onboard visible calibration using solar diffusers, using other methods, such as ray-matching or deep convective clouds. Also the next generation GEOs will have onboard visible calibration, which will increase the accuracy of this method. Three Meteosats over the Libyan desert will be used to illustrate the DERM method. The reference Meteosat will be inter-calibrated against Aqua-MODIS. The reference GEO DERM will be constructed and used to calibrate the remaining Meteosats. The DERM calibration will be validated by comparing the calibration using Aqua-MODIS ray-matching. Similarly, two GOES sensors using the Sonoran desert will also be highlighted. An uncertainty analysis will also be performed with emphasis on the SBAF, derived over the desert targets using both SCIAMACHY and Hyperion hyper-spectral radiances.

David Doelling

Simplified Vicarious Radiometric Calibration

A measurement-based radiance estimation approach for vicarious radiometric calibration of spaceborne multispectral remote sensing systems has been developed. This simplified process eliminates the use of radiative transfer codes and reduces the number of atmospheric assumptions required to perform sensor calibrations. Like prior approaches, the simplified method involves the collection of ground truth data coincident with the overpass of the remote sensing system being calibrated, but this approach differs from the prior techniques in both the nature of the data collected and the manner in which the data are processed. In traditional vicarious radiometric calibration, ground truth data are gathered using ground-viewing spectroradiometers and one or more sun photometer( s), among other instruments, located at a ground target area. The measured data from the ground-based instruments are used in radiative transfer models to estimate the top-of-atmosphere (TOA) target radiances at the time of satellite overpass. These TOA radiances are compared with the satellite sensor readings to radiometrically calibrate the sensor. Traditional vicarious radiometric calibration methods require that an atmospheric model be defined such that the ground-based observations of solar transmission and diffuse-to-global ratios are in close agreement with the radiative transfer code estimation of these parameters. This process is labor-intensive and complex, and can be prone to errors. The errors can be compounded because of approximations in the model and inaccurate assumptions about the radiative coupling between the atmosphere and the terrain. The errors can increase the uncertainty of the TOA radiance estimates used to perform the radiometric calibration. In comparison, the simplified approach does not use atmospheric radiative transfer models and involves fewer assumptions concerning the radiative transfer properties of the atmosphere. This new technique uses two neighboring uniform ground target areas having different reflectance values. The target areas can be natural or artificial and must be large enough to minimize adjacent-pixel contamination effects. The radiative coupling between the atmosphere and the terrain needs to be approximately the same for the two targets. This condition can be met for relatively uniform backgrounds when the distance between the targets is within a few hundred meters. For each target area, the radiance leaving the ground in the direction of the satellite is measured with a radiometrically calibrated spectroradiometer. Using the radiance measurements from the two targets, atmospheric adjacency and atmospheric scattering effects can be subtracted, thereby eliminating many assumptions about the atmosphere and the radiative interaction between the atmosphere and the terrain. In addition, the radiometrically calibrated spectroradiometer can be used with a known reflectance target to estimate atmospheric transmission and diffuse- to-global ratios without the need for ancillary sun photometers. Several comparisons between the simplified method and traditional techniques were found to agree within a few percent. Hence, the simplified method reduces the overall complexity of performing vicarious calibrations and can serve as a method for validating traditional radiative transfer models

Stanley, Thomas

Infrastructure-Based Cooperative Perception at a Traffic Intersection: Overview and Challenges: Preprint

Recent advancement in autonomous driving vehicles and V2X communication has attracted increasing attention towards Intelligent Transportation Systems to build a safe and reliable traffic intersection. However, most of the systems are still at the initial stages and require significant progress to become a reality. This paper presents an overview of NREL Infrastructure Perception and Control (IPC) framework which is an open-source track-data fusion engine which takes input from infrastructure-based perception sensors and cooperatively shared messages from Connected Autonomous Vehicles (CAVs) and Connected Vehicle (CVs) and the challenges associated with deploying such cooperative perception framework at a four-way traffic intersection in the city of Colorado Springs, CO, USA. The sensor data is collected by deploying two radars and two LiDAR sensors on the IPC mobile lab and two radars on diagonally opposite traffic poles at the proposed intersection. The sensor output results imply the need for rapid sensor calibration to bring the collective perception to a common coordinate frame, the importance of time synchronization between the sensors in order to capture accurate spatial and temporal alignment of the objects, and the need for a health monitoring system with fail safe closed-loop detection model for real-time deployment.

camera

Calibration of passive remote observing optical and microwave instrumentation; Proceedings of the Meeting, Orlando, FL, Apr. 3-5, 1991

Various papers on the calibration of passive remote observing optical and microwave instrumentation are presented. Individual topics addressed include: on-board calibration device for a wide field-of-view instrument, calibration for the medium-resolution imaging spectrometer, cryogenic radiometers and intensity-stabilized lasers for EOS radiometric calibrations, radiometric stability of the Shuttle-borne solar backscatter ultraviolet spectrometer, ratioing radiometer for use with a solar diffuser, requirements of a solar diffuser and measurements of some candidate materials, reflectance stability analysis of Spectralon diffuse calibration panels, stray light effects on calibrations using a solar diffuser, radiometric calibration of SPOT 23 HRVs, surface and aerosol models for use in radiative transfer codes. Also addressed are: calibrated intercepts for solar radiometers used in remote sensor calibration, radiometric calibration of an airborne multispectral scanner, in-flight calibration of a helicopter-mounted Daedalus multispectral scanner, technique for improving the calibration of large-area sphere sources, remote colorimetry and its applications, spatial sampling errors for a satellite-borne scanning radiometer, calibration of EOS multispectral imaging sensors and solar irradiance variability.

Guenther, Bruce W.

Evaluation of Aqua MODIS and S-NPP VIIRS Thermal Emissive Bands Calibration Stability Using Dome-C

Establishing the calibration consistency between satellite measurements is an essential step in the implementation of a long-term global monitoring plan, which often leads to sensor calibration improvements. The Suomi National Polar-Orbiting Partnership (S-NPP) Visible Infrared Imaging Radiometer Suite (VIIRS) is a polar-orbiting Earth remote sensing instrument built with a strong Moderate Resolution Imaging Spectroradiometer (MODIS) heritage. The center wavelengths of all VIIRS thermal emissive bands (TEBs) match well with those of MODIS with the exception of VIIRS TEB M15 (10.7μm). Previous work from the MODIS Characterization Support Team (MCST) at the NASA/GSFC used specific Earth surface targets to track the long-term consistency,stability, and relative bias between the two MODIS instruments onboard the Terra and Aqua satellites. Using similar methodologies, this paper evaluates the TEB calibration consistency between the MODIS instruments and S-NPP VIIRS over Dome Concordia (Dome-C). The Dome-C site is uniformly snow-covered and the atmospheric effects are small in the surrounding area. Near-surface air temperature measurements from an Automatic Weather Station (AWS) are used as a reference to track each sensor’s calibration stability and determine the relative bias between the MODIS and VIIRS instruments. The results of this study provide a quantitative assessment of the S-NPP VIIRS TEB mission-long performance.

MODIS

Recent Goddard Space Flight Center (GSFC) experience with on-orbit calibration of attitude sensors

The results of on-orbit calibration for several satellites by the flight Dynamics Facility (FDF) at GSFC are reviewed. The examples discussed include attitude calibrations for sensors, including fixed-head star trackers, fine sun sensors, three-axis magnetometers, and inertial reference units taken from recent experience with the Compton Gamma Ray observatory, the Upper Atmosphere Research Satellite, and the Extreme Ultraviolet Explorer calibration. The methods used and the results of calibration are discussed, as are the improvements attained from in-flight calibration.

Davis, W.

Detector Noise Characterization and Performance of MODIS Thermal Emissive Bands

MODIS has 16 thermal emissive bands, a total of 160 individual detectors (10 for each spectral bands), located on the two cold focal plane assemblies (CFPA). MODIS TEB detectors were fully characterized pre-launch in a thermal vacuum (TV) environment using a NIST traceable blackbody calibration source (BCS) with temperatures ranging from 170 to 340K. On-orbit the TEB detectors are calibrated using an on-board blackbody (BB) on a scan-by-scan basis. For nominal on-orbit operation, the on-board BB temperature is typically controlled at 285K for Aqua MODIS and 290K for Terra MODIS. For the MODIS TEB calibration, each detector's noise equivalent temperature difference (NEdT) is often used to assess its performance and this parameter is a major contributor to the calibration uncertainty. Because of its impact on sensor calibration and data product quality, each MODIS TEB detector's NEdT is monitored on a daily basis at a fixed BB temperature and completely characterized on a regular basis at a number of BB temperatures. In this paper, we describe MODIS on-orbit TEB NEdT characterization activities, approaches, and results. We compare both pre-launch and on-orbit performance with sensor design specification and examine detector noise characterization impact on the calibration uncertainty. To date, 135 TEB detectors (out of a total of 160 detectors) in Terra MODIS (launched in December 1999) and 158 in Aqua MODIS (launched in May 2002) continue to perform with their NEdT below (or better than) their design specifications. A complete summary of all TEB noisy detectors, identified both pre-launch and on-orbit, is provided.

Xiong, X.

Results from Solar Reflective Band End-to-End Testing for VIIRS F1 Sensor Using T-SIRCUS

Verification of the Visible Infrared Imager Radiometer Suite (VIIRS) End-to-End (E2E) sensor calibration is highly recommended before launch, to identify any anomalies and to improve our understanding of the sensor on-orbit calibration performance. E2E testing of the Reflective Solar Bands (RSB) calibration cycle was performed pre-launch for the VIIRS Fight 1 (F1) sensor at the Ball Aerospace facility in Boulder CO in March 2010. VIIRS reflective band calibration cycle is very similar to heritage sensor MODIS in that solar illumination, via a diffuser, is used to correct for temporal variations in the instrument responsivity. Monochromatic light from the NIST T-SIRCUS was used to illuminate both the Earth View (EV), via an integrating sphere, and the Solar Diffuser (SD) view, through a collimator. The collimator illumination was cycled through a series of angles intended to simulate the range of possible angles for which solar radiation will be incident on the solar attenuation screen on-orbit. Ideally, the measured instrument responsivity (defined here as the ratio of the detector response to the at-sensor radiance) should be the same whether the EV or SD view is illuminated. The ratio of the measured responsivities was determined at each collimator angle and wavelength. In addition, the Solar Diffuser Stability Monitor (SDSM), a ratioing radiometer designed to track the temporal variation in the SD BRF by direct comparison to solar radiation, was illuminated by the collimator. The measured SDSM ratio was compared to the predicted ratio. An uncertainty analysis was also performed on both the SD and SDSM calibrations.

McIntire, Jeff

V/STOL tilt rotor research aircraft. Volume 2: Ship 1 instrumentation

Information covering sensor cables, sensor installation, and sensor calibration for the XV-15 aircraft number 1 is included. For each junction box (J-box) designation there is a schematic of the J-box disconnect harness instrumentation worksheets which show sensor location, and calibration data sheets for each sensor associated with that J-box. An index of measurement item codes to J-box locations is given in a table. Cross references are given.

Source record

V/STOL tilt rotor research aircraft. Volume 3: Ship 2 instrumentation

Information covering sensor cables, sensor installation, and sensor calibration for the XV-15 aircraft number 2 is included. For each junction box (J-box) designation there is a schematic of the J-box disconnect harness, instrumentation worksheets which show sensor location, and calibration data sheets for each sensor associated with that J-box. An index of measurement data codes to J-box locations is given in a table. Cross references are given.

Source record

Methods for Radiometric Cross-Calibration of Imaging Sensors With and Without Overlapping Collections

This slide presentation reviews methods of cross calibration for imaging sensors. Cross calibration methods fall under two categories: (1) Relies on knowledge of a source that is common to both sensors, (2) Typically near-coincident views. Some work has used methods that do not require simultaneous data collections. This talk discusses the International System of Units (SI) -traceable approaches that permit cross-calibration. It describes on-orbit cross-calibration methods that are typically used, with and without overlapping views. It reviews sample results. It also describes a method without overlapping views and without on-site measurements.

Thome, K. J.

Assessment, Validation, and Refinement of the Atmospheric Correction Algorithm for the Ocean Color Sensors

The primary focus of this proposed research is for the atmospheric correction algorithm evaluation and development and satellite sensor calibration and characterization. It is well known that the atmospheric correction, which removes more than 90% of sensor-measured signals contributed from atmosphere in the visible, is the key procedure in the ocean color remote sensing (Gordon and Wang, 1994). The accuracy and effectiveness of the atmospheric correction directly affect the remotely retrieved ocean bio-optical products. On the other hand, for ocean color remote sensing, in order to obtain the required accuracy in the derived water-leaving signals from satellite measurements, an on-orbit vicarious calibration of the whole system, i.e., sensor and algorithms, is necessary. In addition, it is important to address issues of (i) cross-calibration of two or more sensors and (ii) in-orbit vicarious calibration of the sensor-atmosphere system. The goal of these researches is to develop methods for meaningful comparison and possible merging of data products from multiple ocean color missions. In the past year, much efforts have been on (a) understanding and correcting the artifacts appeared in the SeaWiFS-derived ocean and atmospheric produces; (b) developing an efficient method in generating the SeaWiFS aerosol lookup tables, (c) evaluating the effects of calibration error in the near-infrared (NIR) band to the atmospheric correction of the ocean color remote sensors, (d) comparing the aerosol correction algorithm using the singlescattering epsilon (the current SeaWiFS algorithm) vs. the multiple-scattering epsilon method, and (e) continuing on activities for the International Ocean-Color Coordinating Group (IOCCG) atmospheric correction working group. In this report, I will briefly present and discuss these and some other research activities.

Wang, Menghua

The INSTEP Monitoring Network: Merging High-and-Low Cost Measurements to Characterize California Wildfires

Despite challenges with data quality and scope, low-cost sensor networks have skyrocketed in popularity over the last 15 years, making air quality data available on refined spatial scales. More recently, studies have leveraged both high and low-quality instruments to create stronger “hybrid” models, with most studies focusing on particulate matter. Low-cost measurements typically represent ground-level emissions only, providing context for human health issues from climate change-driven events such as wildfires. Since low-cost sensors’ capabilities are localized, daily events and microclimates tend to dominate the data rather than larger regional or atmospheric trends. Likewise, their low cost explains their high uncertainty. In contrast, some regulatory-grade instruments produce column measurements as well, providing reliable information on a broader scope. To bridge this gap while expanding into gas-phase measurements, we deployed 12 air quality sensor packages in California, USA during the 2022 wildfire season. These INSTEP (Inexpensive Network Sensor Technology Exploring Pollution) monitors measure carbon monoxide (CO), carbon dioxide (CO2), ozone (O3), nitrogen dioxide (NO2), and several hydrocarbons including methane (CH4) and formaldehyde (HCHO). Half of the monitors were co-located with remote sensing spectrometers: NASA Pandora and Total Column Carbon Observing Network (TCCON). The overlap in pollutants includes NO2, O3, and HCHO between the INSTEP monitors and the Pandora column measurements. TCCON covers column CO, CO2, and CH4, rounding out our comparison. Most of the monitors were distributed throughout the San Francisco Bay area, and an additional three were located within 100 km of Los Angeles. The sites ranged in geographic and population characteristics, including desert, mountainous, coastal, and urban locations. Since varying environmental conditions such as temperature and pressure are known to challenge sensor performance, we will apply newer sensor “calibration” techniques meant to combat this. We will normalize our sensor signals by z-scoring them prior to applying a single calibration model in the form of multivariate linear regression or an artificial neural network. While this technique has been validated for the hydrocarbon and ozone sensor types (metal oxide), it has not yet been tested on electrochemical and non-dispersive infrared sensors, which are also used in the INSTEP monitors. This will serve as a test to see if this normalization technique – or another – is most effective in accounting for environmental differences among sensors. Related data analysis efforts have found success with a variety of geospatial analysis techniques, including weighted network models in which high-quality instruments are given higher weights than their low-cost counterparts. Our preliminary analysis will focus on kriging, which uses a Gaussian algorithm to assign weights, providing estimated pollution levels at locations between monitors. Smoke trajectory and evolution will also be considered using both measurement types. We also aim to baseline subtract our emission estimates from each region to determine which portion of emissions are regional and local, further characterizing burn differences in northern and southern California fires. Future directions include using INSTEP jointly with TEMPO satellite data, and mobile deployments on aircraft and uncrewed aerial vehicles (UAV).

Low-cost sensors

Delta Method Application for the Correlation of IR Detector Thermal Parasitic Loads with Statistically Accurate Results

The Linear Etalon Imaging Spectral Array (LEISA) is a cryogenic IR detector that is passively cooled below 110K. LEISA is part of the L’Ralph instrument, which is going on the Lucy mission, with planned flyby’s of the Trojan asteroids around 5.5 AU. One of the primary thermal challenges is to successfully quantify each significant parasitic heat flow value with statistical certainty.Simulation of flight-like thermal environments and correlation of thermal models is an important part of this challenge, which can be critical for thermally sensitive systems such as cryogenic detectors that are passively cooled. It is common practice during TVAC to achieve several thermal balance points and then to correlate several design variables in order to achieve the closest match to all balance points tested. This approach lends itself to high levels of uncertainty in the correlated values due to the cumulative effect of absolute temperature uncertainty and differences between the sensors used for the measurement. Accuracy can be improved with the use of more accurate sensors, by calibrating all sensors with respect to each other, and by using Zero-Q methodologies, all of which add cost and complexity to the test.The Delta Method uses the difference in temperature caused by the changes in the boundary conditions to calculate heat flows and/or thermal resistances across temperature differentials. This eliminates the problem of high uncertainties with absolute temperature measurements, and yields statistically accurate results down to the sensor resolution of 1mK at < 100K, by taking the sensor’s calibration errors out of the equation. During testing, this method relies on parametric variations around an initial balance point, by varying the boundary conditions of the different parasitic heat sources. The Delta Method, as well as its application on the LEISA thermal test, will be discussed in detail.

Daniel G. Bae

Additional Characterization of Dome-C to Improve its Use as an Invariant Visible Calibration Target

Dome-C is a recommended CEOS invariant target that has been utilized by the calibration community for several decades for monitoring onboard sensor calibration systems as well radiometric inter-comparisons. Dome-C is a high-altitude Earth target located on the East Antarctic interior plateau, which has a permanent bright, flat, and homogeneous snow-covered surface with little aerosol, cloud cover, snowfall, and water vapor burden. This paper describes angular directional models for characterizing the Dome-C top-of-atmosphere (TOA)radiances as a function of cosine solar zenith angle for pre-solstice and post-solstice conditions. The 0.86-μm channel Dome-C reflectance decreases over the summer due to snow metamorphosisis not observed by the visible channels. Coinciding Terra and AquaMODIS Dome-C reflectance showed occasional inter-annual anomalies when compared against the deep convective cloud and Libya-4 invariant targets observations. Further characterization of the Dome-C reflectances with the Dome-C surface broadband albedo, Antarctic Oscillation(AAO) index, and ozone concentration values were evaluated. A strong correlation with ozone was found for the 0.55-μm and 0.65-μm MODIS channels. The monthly Dome-C reflectances were linearly regressed with ozone to derive the ozone correction coefficients. The uncertainty in the Aqua-and Terra-MODIS Dome-C trends was reduced by half after applying ozone corrections to both the 0.55-μm and 0.65-μm channelTOA observations.

David R Doelling