Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensitivity and Specificity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Sensitivity studies associated with dosimetry experiment interpretation

Document available in abstract form only, full text of document follows: Interpretation of reactor dosimetry experiments with C/E comparison requires precise knowledge of parameters involved in modeling. Some parameters have more weight than others on the calculated values. So, sensitivity studies should be conducted to verify the importance of these parameters. The conclusions of these studies are used to refine the experiment modeling, or to correct uncertainty calculations. The results of these sensitivity studies allow a post-irradiation analysis, which can justify the discarding of some atypical C/M values. Derived uncertainties may be improved by the sensitivity analyses. Beyond classical parameters as geometry or composition, this paper describes some specific sensitivity studies conducted for dosimetry irradiation in reactor, and presents conclusions. These studies are based on dosimeters irradiated in the EOLE reactor facility at Cadarache CEA center. Conclusions drawn from these studies are generic and can be applied to any dosimetry study. Calculations performed for these studies were realized using TRIPOLI-4 Monte Carlo code. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Element-specific first order reversal curves measured by magnetic transmission x-ray microscopy

The first-order reversal curve (FORC) method is a macroscopic measurement technique that can be used to extract quantitative and microscopic properties of hysteretic systems. Using magnetic transmission x-ray microscopy (MTXM), local element-specific FORC measurements are performed on a 20 nm thick film of CoTb. The FORCs measured with microscopy reveal a step-by-step domain evolution under the magnetic field cycling protocol and provide a direct visualization of the mechanistic interpretation of FORC diagrams. They are compared with magnetometry FORCs and show good quantitative agreement. Furthermore, the high spatial resolution and element-specific sensitivity of MTXM provide new capabilities to measure FORCs in small regions or specific phases within multicomponent systems, including buried layers in heterostructures. The ability to perform FORCs on very small features is demonstrated with the MTXM-FORC measurement of a rectangular microstructure with vortex-like Landau structures. This work demonstrates the confluence of two uniquely powerful techniques to achieve quantitative insight into nanoscale magnetic behavior.

36 MATERIALS SCIENCE↗

Computer-aided measurement of liver volumes in CT by means of geodesic active contour segmentation coupled with level-set algorithms

Purpose: Computerized liver extraction from hepatic CT images is challenging because the liver often abuts other organs of a similar density. The purpose of this study was to develop a computer-aided measurement of liver volumes in hepatic CT. Methods: The authors developed a computerized liver extraction scheme based on geodesic active contour segmentation coupled with level-set contour evolution. First, an anisotropic diffusion filter was applied to portal-venous-phase CT images for noise reduction while preserving the liver structure, followed by a scale-specific gradient magnitude filter to enhance the liver boundaries. Then, a nonlinear grayscale converter enhanced the contrast of the liver parenchyma. By using the liver-parenchyma-enhanced image as a speed function, a fast-marching level-set algorithm generated an initial contour that roughly estimated the liver shape. A geodesic active contour segmentation algorithm coupled with level-set contour evolution refined the initial contour to define the liver boundaries more precisely. The liver volume was then calculated using these refined boundaries. Hepatic CT scans of 15 prospective liver donors were obtained under a liver transplant protocol with a multidetector CT system. The liver volumes extracted by the computerized scheme were compared to those traced manually by a radiologist, used as ''gold standard.''Results: The mean liver volume obtained with our scheme was 1504 cc, whereas the mean gold standard manual volume was 1457 cc, resulting in a mean absolute difference of 105 cc (7.2%). The computer-estimated liver volumetrics agreed excellently with the gold-standard manual volumetrics (intraclass correlation coefficient was 0.95) with no statistically significant difference (F=0.77; p(F{<=}f)=0.32). The average accuracy, sensitivity, specificity, and percent volume error were 98.4%, 91.1%, 99.1%, and 7.2%, respectively. Computerized CT liver volumetry would require substantially less completion time (compared to an average of 39 min per case by manual segmentation). Conclusions: The computerized liver extraction scheme provides an efficient and accurate way of measuring liver volumes in CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Engineering an ultra-stable affinity reagent based on Top7

ABSTRACT Antibodies are widely used for diagnostic and therapeutic applications because of their sensitive and specific recognition of a wide range of targets; however, their application is limited by their structural complexity. More demanding applications require greater stability than can be achieved by immunoglobulin-based reagents. Highly-stable, proteinbased affinity reagents are being investigated for this role with the goal of identifying a suitable scaffold that can attain specificity and sensitivity similar to that of antibodies while performing under conditions where antibodies fail. We have engineered Top7 a highly stable, computationally-designed protein to specifically bind human CD4 by inserting a peptide sequence derived from a CD4-specific antibody. Molecular dynamics simulations were used to evaluate the structural effect of the peptide insertion at a specific site within Top7 and suggest that this Top7 variant retains conformational stability over 100 °C. This engineered protein specifically binds CD4 and, consistent with simulations, is extremely resistant to thermal and chemical denaturation retaining its secondary structure up to at least 95°C and requiring 6 M guanidine to completely unfold. This CD4-specific protein demonstrates the functionality of Top7 as a viable scaffold for use as a general affinity reagent which could serve as a robust and inexpensive alternative to antibodies.

59 BASIC BIOLOGICAL SCIENCES↗

Sensitivity Studies of Premixed Flame Response to Transverse, High Frequency Disturbances

This study analyzes the response of premixed flames to high frequency transverse acoustic disturbances. A significant body of experiment, modeling and simulation efforts has been performed to understand the response of the spatially integrated heat release of premixed flames to low-frequency disturbances. These studies quantified this sensitivity through the Flame Transfer Function (FTF), as the global heat release is the key quantity influencing thermoacoustic stability for acoustically compact flames. Recent efforts have expanded these models to consider high-frequency acoustic disturbances, and the sensitivity of premixed flames through the Rayleigh integral (RI). The full Rayleigh Integral, as opposed to simply the spatially integrated heat release, must be considered in these cases where the flame is not acoustically compact. Prior modeling studies considered several effects - stability of axisymmetric flames centered in a cylindrical combustion chamber and the effect of flame offset from the combustor axis and the effect of mean flame asymmetries in the flame centered in the combustor. These studies showed that the flame's stability was sensitive to all these parameters, as well as to the transverse mode in question. In this paper, we quantify these different parametric sensitivities of premixed flame stability in the presence of high-frequency transverse acoustic modes - specifically sensitivity to flame length and nozzle location within the acoustic mode shape for 2 different transverse modes. The sensitivity of the RI to these control parameters provides an improved understanding of which flame parameters are critical to improve the overall thermoacoustic stability of the system.

Acharya, Vishal S.↗

Dynamic balance control in elders: gait initiation assessment as a screening tool

OBJECTIVE: To determine whether measurements of center of gravity-center of pressure separation (CG-CP moment arm) during gait initiation can differentiate healthy from disabled subjects with sufficient specificity and sensitivity to be useful as a screening test for dynamic balance in elderly patients. SUBJECTS: Three groups of elderly subjects (age, 74.97+/-6.56 yrs): healthy elders (HE, n = 21), disabled elders (DE, n = 20), and elders with vestibular hypofunction (VH, n = 18). DESIGN: Cross-sectional, intact-groups research design. Peak CG-CP moment arm measures how far the subject will tolerate the whole-body CG to deviate from the ground reaction force's CP; it represents dynamic balance control. Screening test cutoff points at 16 to 18 cm peak CG-CP moment arm predicted group membership. RESULTS: The magnitude of peak CG-CP moment arm was significantly greater in HE than in DE and VH subjects (p<.01) and was not different between the DE and VH groups. The peak CG-CP moment arm occurred at the end of single stance phase in all groups. As a screening test, the peak moment arm has greater than 50% sensitivity and specificity to discriminate the HE group from the DE and VH groups with peak CG-CP moment arm cutoff points between 16 and 18 cm. CONCLUSIONS: Examining dynamic balance through the use of the CG-CP moment arm during single stance in gait initiation discriminates between nondisabled and disabled older persons and warrants further investigation as a potential tool to identify people with balance dysfunction.

NASA Discipline Neuroscience↗

NOW-23: the 2023 National Offshore Wind Data Set

In this report, we present the latest wind resource data specifically tailored for offshore regions in the United States. The data set, known as the 2023 National Offshore Wind data set (NOW-23), has been developed by the National Renewable Energy Laboratory (NREL) and its partners, and surpasses the previous resource data set, the Wind Integration National Dataset (WIND) Toolkit, which was released approximately ten years ago, in its offshore component. The WIND Toolkit has been widely utilized by stakeholders involved in wind resource assessments across the continental United States. However, with significant advancements in numerical weather prediction modeling over the past decade, the NOW-23 data set incorporates the latest research and development progress to provide stakeholders with an updated and cutting-edge resource for offshore wind analysis. The NOW-23 data set is created using the Weather Research and Forecasting (WRF) model and its output is available, as for its predecessor, at 5-minute time resolution and 2-kilometer horizontal spatial resolution. However, the NOW-23 data set improves upon the WIND Toolkit through: 1. A modeling period of at least 20 years (and as long as 23 years in selected regions), starting in 2000 (compared to the 7-year 2007–2013 modeling period in the WIND Toolkit). 2. For several offshore regions, a region-specific sensitivity analysis, driven by an ensemble of WRF simulations, to assess the most adequate region-specific WRF setup. 3. An updated WRF model, from Version 3.4 used in the WIND Toolkit to Version 4.2.1 used for the NOW-23 data set, which incorporates significant research advancements. 4. The use of the state-of-the-art reanalysis product ERA5 (which supersedes the older ERA-Interim used in the WIND Toolkit) to provide atmospheric forcing at the WRF domain boundaries. Figure 1 shows the NOW-23 mean wind speed at 160 m above sea level (asl), which we use as proxy for hub-height of a commercial offshore wind turbine in this report across all regions.

17 WIND ENERGY↗

Final Report Construction of Whole Genome Microarrays, and Expression Analysis of Desulfovibrio vulgaris cells in Metal-Reducing Conditions

We continue to utilize the oligonucleotide microarrays that were constructed through funding with this project to characterize growth responses of Desulfovibrio vulgaris relevant to metal-reducing conditions. To effectively immobilize heavy metals and radionuclides via sulfate-reduction, it is important to understand the cellular responses to adverse factors observed at contaminated subsurface environments (e.g., nutrients, pH, contaminants, growth requirements and products). One of the major goals of the project is to construct whole-genome microarrays for Desulfovibrio vulgaris. First, in order to experimentally establish the criteria for designing gene-specific oligonucleotide probes, an oligonucleotide array was constructed that contained perfect match (PM) and mismatch (MM) probes (50mers and 70mers) based upon 4 genes. The effects of probe-target identity, continuous stretch, mismatch position, and hybridization free energy on specificity were examined. Little hybridization was observed at a probe-target identity of <85% for both 50mer and 70mer probes. 33 to 48% of the PM signal intensities were detected at a probe-target identity of 94% for 50mer oligonucleotides, and 43 to 55% for 70mer probes at a probe-target identity of 96%. When the effects of sequence identity and continuous stretch were considered independently, a stretch probe (>15 bases) contributed an additional 9% of the PM signal intensity compared to a non-stretch probe (< 15 bases) at the same identity level. Cross-hybridization increased as the length of continuous stretch increased. A 35-base stretch for 50mer probes or a 50-base stretch for 70mer probes had approximately 55% of the PM signal. Mismatches should be as close to the middle position of an oligonucleotide probe as possible to minimize cross-hybridization. Little cross-hybridization was observed for probes with a minimal binding free energy greater than -30 kcal/mol for 50mer probes or -40 kcal/mol for 70mer probes. Based on the experimental results, a set of criteria were suggested for the design of gene-specific and group-specific oligonucleotide probes, and these criteria should provide valuable information for the development of new software and algorithms for microarray-based studies. Secondly, in order to empirically determine the effect of probe length on signal intensities, microarrays with oligonucleotides of different lengths were used to monitor gene expression at a whole genome level. To determine what length of oligonucleotide is a better alternative to PCR-generated probes, the performance of oligonucleotide probes was systematically compared to that of their PCR-generated counterparts for 96 genes from Shewanella oneidensis MR-1 in terms of overall signal intensity, numbers of detected genes, specificity, sensitivity and differential gene expression under experimental conditions. Hybridizations conducted at 42 C, 45 C, 50 C, and 60 C indicated that good sensitivities were obtained at 45 C for oligonucleotide probes in the presence of 50% formamide, under which conditions specific signals were detected by both PCR and oligonucleotide probes. Signal intensities increased as the length of oligonucleotide probes increased, and the 70mer oligonucleotide probes produced similar signal intensities and detected a similar number of ORFs compared to the PCR probes. cDNA, 70mer, 60mer and 50mer arrays had detection sensitivities at 5.0, 25, 100 and 100 ng of genomic DNA, or an approximately equivalent of 1.9 x 10{sup 6}, 9.2 x 10{sup 6}, 3.7 x 10{sup 7} and 3.7 x 10{sup 7} copies, respectively when the array was hybridized with genomic DNA. To evaluate differential gene expression under experimental conditions, S. oneidensis MR-1 cells were exposed to low or high pH conditions for 30 and 60 min, and the transcriptional profiling detected by oligonucleotide probes (50mer, 60mer, and 70mer) was closely correlated with that detected by the PCR probes. The results demonstrated that 70mer oligonucleotides can achieve the most comparable performance with PCR-generated probes. We have analyzed expression data as D. vulgaris transitioned during electron donor depletion. As the cells transitioned from exponential to stationary-phase a majority of the down-expressed genes were involved in translation and transcription, and this trend continued in the remaining time points. Interestingly, most phage-related genes were up-expressed at the onset of stationary-phase. This result suggested that nutrient depletion may impact community dynamics and DNA transfer mechanisms of sulfate-reducing bacteria via phage cycle. The putative feoAB system (in addition to other presumptive iron metabolism genes) was significantly up-expressed, and suggested the possible importance of Fe{sup 2+} acquisition under metal-reducing conditions. Namely, that iron availability should be considered when sulfate-reducing conditions are stimulated in the subsurface for heavy metal reduction.

54 ENVIRONMENTAL SCIENCES↗

Accuracy of Fukuoka and American Gastroenterological Association Guidelines for Predicting Advanced Neoplasia in Pancreatic Cyst Neoplasm: A Meta-Analysis

Background: A differential diagnosis of advanced pancreatic cystic neoplasms (PCNs) is critical to determine optimal treatment. The Fukuoka and American Gastroenterological Association (AGA) guidelines are the most widely accepted criteria for the management of PCNs. Objective: This study aimed to evaluate the diagnostic value of these guidelines in predicting advanced neoplasia (AN). Methods: A comprehensive electronic search of the PubMed, EMBASE, Web of Science, Cochrane Library, and Scopus databases was conducted to identify all relevant studies evaluating the Fukuoka and AGA guidelines in surgically resected and histologically confirmed PCNs. Pooled sensitivity, specificity, and diagnostic odds ratios (DORs) were calculated as compound measures of diagnostic accuracy using the random-effects model. Summary of receiver operating characteristic (SROC) curves and the area under the curve (AUC) were also performed. Results: A total of 21 studies with 3723 patients were included in this meta-analysis. Of these studies, 15, 4, and 2 evaluated the Fukuoka guidelines, the AGA guidelines, and both guidelines, respectively. For AN prediction, the Fukuoka guidelines had a pooled sensitivity of 0.67 (95% confidence interval [CI] 0.64–0.70), pooled specificity of 0.64 (95% CI 0.62–0.66), and pooled DOR of 6.28 (95% CI 4.38–9.01), with an AUC of the SROC of 0.78. AGA guidelines showed a pooled sensitivity of 0.59 (95% CI 0.52–0.65), pooled specificity of 0.77 (95% CI 0.74–0.80), and pooled DOR of 5.84 (95% CI 2.60–13.15), with an AUC of 0.79 (95% CI 0.70–0.88). Conclusion: When used alone, the Fukuoka and AGA guidelines showed similar but unsatisfactory diagnostic accuracy in the risk stratification of malignant potential of PCN. Thus, we recommend that they be applied only as a broad framework in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of Aerodynamic Matching Sensitivities for Conceptual Design

A methodology for aerodynamic matching was implemented in the Higher fidelity Conceptual Design and structural optimization (HCDstruct) tool to support transonic flutter simulations. The Enhanced Factor Correction Technique was implemented in HCDstruct to correct the Nastran doublet lattice method using data from corresponding computational fluid dynamics simulations. In this paper, sensitivities associated with this aerodynamic matching technique were investigated using HCDstruct and a Boeing 737-200-like aircraft configuration. Specifically, sensitivities of the aerodynamic matching method were investigated with respect to changes in flight conditions, such as changes in Mach number and angle of attack, and also in key design variables for the main wing, such as changes in aspect ratio and sweep angle. The variations in flight conditions and design parameters were mapped to estimated prediction error in sectional lift for the main wing, which helps to demonstrate the extent to which a user may expect a given aerodynamic correction matrix to provide suitable aerodynamic predictions for a realistic aircraft wing.

Jesse R. Quinlan↗

Investigation of Aerodynamic Matching Sensitivities for Conceptual Design

A methodology for aerodynamic matching was implemented in the Higher fidelity Conceptual Design and structural optimization (HCDstruct) tool to support transonic flutter simulations. The Enhanced Factor Correction Technique was implemented in HCDstruct to correct the Nastran doublet lattice method using data from corresponding computational fluid dynamics simulations. In this paper, sensitivities associated with this aerodynamic matching technique were investigated using HCDstruct and a Boeing 737-200-like aircraft configuration. Specifically, sensitivities of the aerodynamic matching method were investigated with respect to changes in flight conditions, such as changes in Mach number and angle of attack, and also in key design variables for the main wing, such as changes in aspect ratio and sweep angle. The variations in flight conditions and design parameters were mapped to estimated prediction error in sectional lift for the main wing, which helps to demonstrate the extent to which a user may expect a given aerodynamic correction matrix to provide suitable aerodynamic predictions for a realistic aircraft wing.

Jesse Ray Quinlan↗

SU-E-J-142: Performance Study of Automatic Image-Segmentation Algorithms in Motion Tracking Via MR-IGRT

Purpose: Evaluate commonly used segmentation algorithms on a commercially available real-time MR image guided radiotherapy (MR-IGRT) system (ViewRay), compare the strengths and weaknesses of each method, with the purpose of improving motion tracking for more accurate radiotherapy. Methods: MR motion images of bladder, kidney, duodenum, and liver tumor were acquired for three patients using a commercial on-board MR imaging system and an imaging protocol used during MR-IGRT. A series of 40 frames were selected for each case to cover at least 3 respiratory cycles. Thresholding, Canny edge detection, fuzzy k-means (FKM), k-harmonic means (KHM), and reaction-diffusion level set evolution (RD-LSE), along with the ViewRay treatment planning and delivery system (TPDS) were included in the comparisons. To evaluate the segmentation results, an expert manual contouring of the organs or tumor from a physician was used as a ground-truth. Metrics value of sensitivity, specificity, Jaccard similarity, and Dice coefficient were computed for comparison. Results: In the segmentation of single image frame, all methods successfully segmented the bladder and kidney, but only FKM, KHM and TPDS were able to segment the liver tumor and the duodenum. For segmenting motion image series, the TPDS method had the highest sensitivity, Jarccard, and Dice coefficients in segmenting bladder and kidney, while FKM and KHM had a slightly higher specificity. A similar pattern was observed when segmenting the liver tumor and the duodenum. The Canny method is not suitable for consistently segmenting motion frames in an automated process, while thresholding and RD-LSE cannot consistently segment a liver tumor and the duodenum. Conclusion: The study compared six different segmentation methods and showed the effectiveness of the ViewRay TPDS algorithm in segmenting motion images during MR-IGRT. Future studies include a selection of conformal segmentation methods based on image/organ-specific information, different filtering methods and their influences on the segmentation results. Parag Parikh receives research grant from ViewRay. Sasa Mutic has consulting and research agreements with ViewRay. Yanle Hu receives travel reimbursement from ViewRay. Iwan Kawrakow and James Dempsey are ViewRay employees.

60 APPLIED LIFE SCIENCES↗

Diagnostic accuracy of MRI with extracellular vs. hepatobiliary contrast material for detection of residual hepatocellular carcinoma after locoregional treatment

Purpose: To compare the diagnostic accuracy of extracellular gadolinium-based contrast-enhanced MRI (Gd-MRI) and gadoxetic acid-enhanced MRI (EOB-MRI) for the assessment of hepatocellular carcinoma (HCC) response to locoregional therapy (LRT) using explant correlation as the reference standard. Methods: Forty-nine subjects with cirrhosis and HCC treated with LRT who underwent liver MRI using either Gd-MRI (n = 26) or EOB-MRI (n = 23) within 90 days of liver transplantation were included. Four radiologists reviewed the MR images blinded to histology to determine the size and percentage of viable residual HCC using a per-lesion explant reference standard. Sensitivities, specificities, accuracies, and agreement with histology for the detection residual HCC were calculated. Results: Gd-MRI had greater agreement with histology (ICC: 0.98 [0.95–0.99] vs. 0.80 [0.63–0.90]) and greater sensitivity for viable HCC (76% [13/17 50–93%] vs. 58% [7/12; 28–85%]) than EOB-MRI; specificities were similar (84% [16/19; 60–97%] vs. 85% [23/27; 66–96%]). Areas under ROC curves for detecting residual viable tumor were 0.80 (0.64–0.92) for Gd-MRI and 0.72 (0.55–0.85) for EOB-MRI. Gd-MRI had greater inter-rater agreement than EOB-MRI for determining the size of residual viable HCC (ICC: 0.96 [0.92–0.98] vs. 0.85 [0.72–0.92]). Conclusion: Gd-MRI may be more accurate and precise than EOB-MRI for the assessment of viable HCC following LRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Infections in patients using ventricular-assist devices: Comparison of the diagnostic performance of {sup 18}F-FDG PET/CT scan and leucocyte-labeled scintigraphy

Background: The usage of left-ventricular-assist device (LVAD) is increasing in patients presenting with advanced heart failure. However, device-related infections are a challenge to recognize and to treat, with an important morbidity and mortality rate. The role of nuclear medicine imaging remains not well established for LVAD infections. The present study compared the accuracy of positron emission tomography/computed tomography with {sup 18}F-fludeoxyglucose ({sup 18}F-FDG PET/CT) and radiolabeled leucocyte scintigraphy for the diagnosis of infections in patients supported with a continuous-flow LVAD. Methods: From a prospectively maintained database, we retrospectively analyzed the diagnostic performance of radiolabeled leucocyte scintigraphy and {sup 18}F-FDG PET/CT in 24 patients who had a LVAD with a suspected device-related infection. Both examinations were routinely performed in all patients. Infection was assessed by the International Society for Heart and Lung Transplantation criteria. Results: Twenty-four patients were included: 15 had a specific VAD infection (5 cardiac-LVAD and 10 driveline), 6 had a VAD-related infection, while 3 patients had a non-VAD-related infection. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 95.2%, 66.7%, 95.2%, 66.7%, and 91.6%, respectively, for {sup 18}F-FDG-PET; and 71.4%, 100%, 100%, 33.3%, and 75%, respectively, for leucocyte scintigraphy. {sup 18}F-FDG PET/CT showed significantly higher sensitivity (P = 0.01) than leucocyte scintigraphy. Conclusion: {sup 18}F-FDG PET/CT and radiolabeled leucocyte scintigraphy single-photon emission computed tomography carry high performance in the diagnostic of LVAD infections. {sup 18}F-FDG PET/CT shows significantly higher sensitivity and could be proposed as first-line nuclear medicine procedure. [French] French Abstract: Contexte: L’utilisation du dispositif d’assistance ventriculaire gauche (DAVG) est en utilisation croissante chez les patients avec insuffisance cardiaque avancée. Cependant, les infections liées au dispositif sont un défi à reconnaître et à traiter en raison d’ un taux de morbidité et de mortalité important. Le rôle de l’imagerie de médecine nucléaire n’est pas encore bien établi pour les infections secondaires au DAVG. La présente étude compare la précision de la tomographie par émission de positrons / tomodensitométrie au 18F-fluorodéoxyglucose (18F-FDG TEP/TDM) et la scintigraphie leucocytaire radio-marquée pour le diagnostic d’infections chez des patients porteurs par un DAVG à flux continu. Méthodes: A partir d’une base de données complétée de manière prospective nous avons analysé rétrospectivement les performances diagnostiques de la scintigraphie leucocytaire radio-marquée et de la TEP / TDM au 18F-FDG chez 24 patients ayant un DAVG avec une infection suspectée liée à l’appareillage. Les deux types d’examens scintigraphiques ont été systématiquement réalisé chez tous les patients. Le diagnostic d’infection fut établi selon les critères ISHLT. Résultats: Parmi les 24 patients inclus, 15 avaient une infection spécifique de l’appareillage AVG (5 au niveau de la pompe et/ou canule d’insertion myocardique) et 10 au niveau du driveline, 6 avaient une infection indirectement liée à l’appareillage AVG, tandis que 3 patients avaient une infection non liée au DAVG. La sensibilité, la spécificité, la valeur prédictive positive, la valeur prédictive négative et la précision étaient de 95,2%, 66,7%, 95,2%, 66,7% et 91,6%, respectivement, pour le 18F-FDG-PET et 71,4%, 100%, 100%, 33,3 %, et 75%, respectivement, pour la scintigraphie leucocytaire. La TEP / TDM au 18F-FDG a montré une sensitivité significativement plus élevée (p = 0,01) que la scintigraphie leucocytaire. Conclusion: 18F-FDG TEP/TDM et scintigraphie leucocytaire radio-marquée SPECT s’avèrent très efficaces pour le diagnostic des infections à DVAG. La TEP/TDM au 18F-FDG montre une sensibilité significativement plus élevée et pourrait être proposée en tant que la procédure de médecine nucléaire de premier choix. [Spanish] Spanish Abstract: Antecedentes: El uso de dispositivos de asistencia ventricular izquierda (DAVI) está incrementando en pacientes con insuficiencia cardiaca avanzada. Sin embargo, las infecciones relacionadas al dispositivo representan un reto diagnóstico y de tratamiento, con una importante tasa de morbilidad y mortalidad. El papel de los estudios de imagen de medicina nuclear en las infecciones de DAVI no se ha establecido claramente. El presente estudio comparó la precisión de la tomografía por emisión de positrones/tomografía computada con {sup 18}F-fluorodesoxiglucosa ({sup 18}F-FDG PET/CT) y la gammagrafía con leucocitos marcados para el diagnóstico de infecciones en pacientes utilizando un DAVI de flujo continuo. Métodos: Desde una base de datos obtenida de manera prospectiva, analizamos de manera retrospectiva el rendimiento diagnóstico de la gammagrafía de leucocitos marcados y del {sup 18}F-FDG PET/CT en 24 pacientes quienes tenían un DAVI con sospecha de infección relacionada al dispositivo. Ambos estudios fueron realizados rutinariamente en todos los pacientes. Se determinó la presencia de infección mediante los criterios de la ISHTL. Resultados: Se incluyeron veinticuatro pacientes, de los cuales 15 tuvieron una infección específica de DAV (5 con infecciones DAVI, y 10 con infección del driveline), 6 tuvieron una infección relacionada al DAV, y 3 pacientes tuvieron una infección no relacionada al DAV. La sensibilidad, especificidad, valor predictivo positivo, valor predictivo negativo y precisión diagnóstica fueron 95.2%, 66.7%, 95.2%, 66.7% y 91.6%, respectivamente para {sup 18}F-FDG PET/CT, y 71.4%, 100%, 100%, 33.3% y 75%, respectivamente para la gammagrafía de leucocitos marcados. El {sup 18}F-FDG PET/CT mostró una significativa mayor sensibilidad (p=0.01) que la gammagrafía con leucocitos marcados. Conclusión: El {sup 18}F-FDG PET/CT y la gammagrafía de leucocitos marcados tienen un alto desempeño en el diagnóstico de infecciones de DAVI. El {sup 18}F-FDG PET/CT muestra una significativa mayor sensibilidad y podría ser propuesto como el procedimiento de medicina nuclear de primera línea. [Chinese] Chinese Abstract: 背景: 左心室辅助装置 (LVAD) 越来越多的应用于重度心力衰竭患者。然而, 设备相关的感染有着重要的发病率和死亡率, 并且对其诊断和治疗均是一项挑战。对于 LVAD 相关感染, 核医学影像可扮演的角色一直没有完善。本研究针对装备有连续流式 LVAD 的感染病人,对比了 {sup 18}F-FDG PET/CT 造影术和放射性标记白细胞闪烁扫描法对感染诊断的准确性。 方法: 从一个前瞻性的数据库, 入选了24名疑似设备感染的 LVAD 病人, 并回顾性的分析了放射性标记白细胞闪烁扫描法和 {sup 18}F-FDG PET/CT 的诊断表现。所有病人都常规进行了上述两种检查。利用 ISHLT 标准对感染情况进行评估。 结果: 在入选的 24 名病人中, 15 名有明确的 VAD 感染 (5 名心脏的 LVAD 和 10 名动力传动系统装置), 6 名有 VAD 相关的感染,另外3名有 VAD 无关的感染。对于 {sup 18}F-FDG PET/CT 诊断方法,其敏感性,特异性,阳性预测值,阴性预测值和准确率分别为: 95.2%, 66.7%, 95.2%, 66.7%, 和 91.6%; 而对于白细胞闪烁扫描诊断方法, 其敏感性, 特异性, 阳性预测值,阴性预测值和准确率分别为: 71.4%, 100%, 100%, 33.3% 和 75%。相比于白细胞闪烁扫描, {sup 18}F-FDG PET/CT 明显展现出较高的敏感性 (p=0.01)。 结论: {sup 18}F-FDG PET/CT 和白细胞闪烁扫描 SPECT 对于 LVAD 感染的诊断具有很好的表现。{sup 18}F-FDG PET/CT 展现出较高的敏感性,可以作为核医学的首要检查。.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MR elastography of liver at 3 Tesla: comparison of gradient-recalled echo (GRE) and spin-echo (SE) echo-planar imaging (EPI) sequences and agreement across stiffness measurements

Purpose: To compare 2D gradient-recalled echo (GRE) and 2D spin-echo (SE) echo-planar imaging (EPI) MR elastography (MRE) for measurement of hepatic stiffness in adult patients with known or suspected liver disease at 3 Tesla. Materials and methods: Three hundred and eighty-seven consecutive patients underwent MRE of the liver at 3 Tesla with 2D-GRE and 2D-SE-EPI sequences. ‘Mean liver stiffness (LS)’ calculated by averaging 3 ROIs in the right lobe, ‘Maximum LS’ calculated by an ROI in the right lobe; and ‘Freehand LS’ calculated by an ROI in the entire liver were measured by two independent readers. Inter-observer and inter-class variability in stiffness measurements were assessed. Stiffness values were correlated with degree of liver fibrosis (METAVIR scores) in 97 patients who underwent biopsy. The diagnostic performance was compared by a receiver-operating characteristic analysis. Results: The technical failure rate was 2.8% for 2D-SE-EPI (11/387) and 4.1% for 2D-GRE (16/387, 9 had R{sub 2}* > 80 s{sup −1} indicating iron overload). There is high reproducibility for both GRE and SE-EPI variants (ICC = 0.84–0.94 for both GRE and SE-EPI MRE). The highest sensitivity, specificity, and accuracy of differentiating mild fibrosis (F0–F2) from advanced fibrosis (F3–F4) are 0.84 (GRE Freehand measurement), 0.92 (GRE Maximum stiffness measurement), and 0.88 (GRE Freehand measurement), respectively. Conclusions: High intra-class correlation and intra-reader correlation are seen on measured hepatic stiffness for both 2D-GRE and 2D-SE-EPI MRE. 2D-SE-EPI has lower failure rate. Diagnostic performance of both sequences is equivalent, with highest sensitivity for 2D-GRE Freehand stiffness measurement, and highest specificity 2D-GRE Maximum stiffness measurement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Biomedical Imaging: SPECT and PET

Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) are non-invasive nuclear imaging techniques relying on the use of tomographic reconstruction methods to provide 3D representations of the distribution of radiolabeled molecules in vivo. Differences in the underlying physical principles determine the achievable spatial resolution, sensitivity, specificity and observation time span of these two imaging modalities. Their specific characteristics are described and the current technology developments and design tradeoffs are reviewed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detection of bioagents using a shear horizontal surface acoustic wave biosensor

Viruses and other bioagents are of high medical and biodefense concern and their detection at concentrations well below the threshold necessary to cause health hazards continues to be a challenge with respect to sensitivity, specificity, and selectivity. Ideally, assays for accurate and real time detection of viral agents and other bioagents would not necessitate any pre-processing of the analyte, which would make them applicable for example to bodily fluids (blood, sputum) and man-made as well as naturally occurring bodies of water (pools, rivers). We describe herein a robust biosensor that combines the sensitivity of surface acoustic waves (SAW) generated at a frequency of 325 MHz with the specificity provided by antibodies and other ligands for the detection of viral agents. In preferred embodiments, a lithium tantalate based SAW transducer with silicon dioxide waveguide sensor platform featuring three test and one reference delay lines was used to adsorb antibodies directed against Coxsackie virus B4 or the negative-stranded category A bioagent Sin Nombre virus (SNV), a member of the genus Hantavirus, family Bunyaviridae, negative-stranded RNA viruses. Rapid detection (within seconds) of increasing concentrations of viral particles was linear over a range of order of magnitude for both viruses, although the sensor was approximately 50.times.10.sup.4-fold more sensitive for the detection of SNV. For both pathogens, the sensor's selectivity for its target was not compromised by the presence of confounding Herpes Simplex virus type 1. The biosensor was able to detect SNV at doses lower than the load of virus typically found in a human patient suffering from hantavirus cardiopulmonary syndrome (HCPS). Further, in a proof-of-principle real world application, the SAW biosensor was capable of selectively detecting SNV agents in complex solutions, such as naturally occurring bodies of water (river, sewage effluent) without analyte pre-processing.

47 OTHER INSTRUMENTATION↗