Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Electrochemical Imaging of Interfaces in Energy Storage via Scanning Probe Methods: Techniques, Applications, and Prospects

Developing a deeper understanding of dynamic chemical, electronic, and morphological changes at interfaces is key to solving practical issues in electrochemical energy storage systems (EESSs). To unravel this complexity, an assortment of tools with distinct capabilities and spatiotemporal resolutions have been used to creatively visualize interfacial processes as they occur. This review highlights how electrochemical scanning probe techniques (ESPTs) such as electrochemical atomic force microscopy, scanning electrochemical microscopy, scanning ion conductance microscopy, and scanning electrochemical cell microscopy are uniquely positioned to address these challenges in EESSs. We describe the operating principles of ESPTs, focusing on the inspection of interfacial structure and chemical processes involved in Li-ion batteries and beyond. We discuss current examples, performance limitations, and complementary ESPTs. Finally, we discuss prospects for imaging improvements and deep learning for automation. We foresee that ESPTs will play an enabling role in advancing EESSs as we transition to renewable energies.

25 ENERGY STORAGE↗

XRF-ROI Finder: Machine Learning to Guide Region-of-Interest Scanning for X-ray Fluorescence Microscopy

The ROI-finder software is being developed for use by several Microscopy Group beamlines at Argonne National Laboratory, including 2-ID microprobes and 9-ID-B Bionanoprobe which use multi-scale scanning fluorescence microscopy to acquire elemental maps (multi-modal image data). Microscopy experiments require scan of samples at a coarse resolution followed by ROI identification using feature detection based on domain expertise. Finer resolution scans are then conducted based on identified ROI. The decision-making process based on domain expertise will be difficult to perform for faster data rates and much larger sampling volumes anticipated after APS-U necessitating the need for the ROI-finder software. The ROI- finder detects regions of interest through a continuous learning process, starting with a unsupervised representation learning and improving its recommendations through supervised learning and an interactive tool for user annotation. The scope of ongoing development efforts includes the integration of image registration module to correlate optical and X-ray images, extraction of feature morphology as well as elemental signatures in the image space and incorporation of beamtime streaming data by the scanning probe via EPICS.

CHOWDHURY, M. ARSHAD ZAHANGIR↗

Hard X-ray imaging with sub-10 nm resolution by scanning bonded 2D multilayer Laue lenses

Multilayer Laue lenses (MLLs) offer significant advantages over traditional diffractive focusing optics, such as zone plates (ZPs), in terms of efficiency and durability when focusing hard X-rays to 10 nm and below. Typically, a pair of 1D MLLs is aligned independently to achieve point focusing. This approach only permits scanning microscopy by moving the sample stage, which presents a limitation when it comes to scanning large or bulky objects at high speed. In this study, we present an experimental demonstration of scanning monolithically bonded 2D MLLs while keeping the sample stationary, effectively addressing the limitation of the sample’s size and weight. We characterized the system’s positional and angular stabilities during scanning, which are critical parameters to the nanofocusing performance of MLLs. In addition, we provided the X-ray measurement results and corresponding image resolution analysis.

36 MATERIALS SCIENCE↗

DSTL HMEX Reference QC Bounds Generation Using 2023 TP89 and Water Scans [Slides]

This presentation covers the results of new QC bounds generated using data from 10 TP89 reference specimen scans and 30 water scans acquired between January 12 and February 2, 2023. All scan data were acquired on the DSTL HMEX MCT system (in lead cabinet). All data presented were from DSTL’s reconstructions of recent HMEX scans.

42 ENGINEERING↗

Overview of a Methodology for Calculating the A Priori Scan Minimum Detectable Concentration for Post-Processed Radiological Surveys (Final Report) (Rev.1)

Increased continuous data collection using automated data loggers and autonomous radiological survey devices or vehicles has introduced a need for corresponding guidance and statistical techniques for data that are collected without surveyor vigilance. This report presents a method for calculating the a priori scan minimum detectable concentrations (MDCs) for surveys performed without vigilance similar to methods described in the Multi-Agency Radiation Survey and Site Investigation Manual, NUREG-1507, and NUREG/CR-6364. A priori scan MDCs are calculated during survey planning to ensure that survey parameters (e.g., scanning speed, scanning altitude, detector geometry) will lead to collecting data in which potentially contaminated areas can be detected when data are processed after the survey, within acceptable statistical error probabilities.

54 ENVIRONMENTAL SCIENCES↗

Understanding the Effect of Electron Beam Melting Scanning Strategies on the Aluminum Content and Materials State of Single Ti-6Al-4V Feedstock

Research on the additive manufacturing of metals often neglects any characterization of the composition of final parts, erroneously assuming a compositional homogeneity that matches the feedstock material. Here, the composition of electron-beam-melted Ti-6Al-4V produced through three distinct scanning strategies (linear raster and two point melting strategies, random fill and Dehoff fill) is characterized both locally and globally through energy-dispersive spectroscopy and quantitative chemical analysis. As a result of the different scanning strategies used, differing levels of preferential vaporization occur across the various parts, leading to distinct final compositions, with extremes of ~5.8 wt.% Al and ~4.8 wt.% Al. In addition, energy-dispersive spectroscopy composition maps reveal specific features in both the XY and XZ planes (with Z being the build direction) as a result of local inhomogeneous preferential vaporization. The subsequent change in composition significantly modifies the materials’ state of parts, wherein parts and local regions with higher aluminum contents lead to higher hardness levels (with a ~50 HV difference) and elastic property values and vice versa. While varying scan strategies and scan parameters are known to modify the microstructure and properties of a part, the effect on composition cannot, and should not, be neglected.

36 MATERIALS SCIENCE↗

An extended radar relative calibration adjustment (eRCA) technique for higher-frequency radars and range–height indicator (RHI) scans

Abstract. This study extends the relative calibration adjustment technique for calibration of weather radars to higher-frequency radars as well as range–height indicator (RHI) scans. The calibration of weather radars represents one of the most dominant sources of error for their use in a variety of fields including quantitative precipitation estimation and model comparisons. While most weather radars are routinely calibrated, the frequency of calibration is often less than required, resulting in miscalibrated time periods. While full absolute calibration techniques often require the radar to be taken offline for a period of time, there have been online calibration techniques discussed in the literature. The relative calibration adjustment (RCA) technique uses the statistics of the ground clutter surrounding the radar as a monitoring source for the stability of calibration but has only been demonstrated to work at S- and C-band for plan-position indicator (PPI) scans at a constant elevation. In this work the RCA technique is modified to work with higher-frequency radars, including Ka-band cloud radars. At higher frequencies the properties of clutter can be much more variable. This work introduces an extended clutter selection procedure that incorporates the temporal stability of clutter and helps to improve the operational stability of RCA for relatively higher-frequency radars. The technique is also extended to utilize range–height scans from radars where the elevation is varied rather than the azimuth. These types of scans are often utilized with research radars to examine the vertical structure of clouds. The newly extended technique (eRCA) is applied to four Department of Energy Atmospheric Radiation Measurement (DOE ARM) weather radars ranging in frequency from C- to Ka-band. Cross comparisons of three co-located radars with frequencies C, X, and Ka at the ARM Cloud, Aerosol, and Complex Terrain Interactions (CACTI) site show that the technique can determine changes in calibration. Using an X-band radar at the ARM Eastern North Atlantic (ENA) site, we show how the technique can be modified to be more resilient to clutter fields that show increased variability, in this case due to sea clutter. The results show that this technique is promising for a posteriori data calibration and monitoring.

47 OTHER INSTRUMENTATION↗

Optimizing radar scan strategies for tracking isolated deep convection using observing system simulation experiments

Abstract. Optimizing radar observation strategies is one of the most important considerations in pre-field campaign periods. This is especially true for isolated convective clouds that typically evolve faster than the observations captured by operational radar networks. This study investigates uncertainties in radar observations of the evolution of the microphysical and dynamical properties of isolated deep convective clouds developing in clean and polluted environments. It aims to optimize the radar observation strategy for deep convection through the use of high-spatiotemporal cloud-resolving model simulations, which resolve the evolution of individual convective cells every 1 min, coupled with a radar simulator and a cell tracking algorithm. The radar simulation settings are based on the Tracking Aerosol Convection Interactions ExpeRiment (TRACER) and Experiment of Sea Breeze Convection, Aerosols, Precipitation and Environment (ESCAPE) field campaigns held in the Houston, TX, area but are generalizable to other field campaigns focusing on isolated deep convection. Our analysis produces the following four outcomes. First, a 5–7 m s−1 median difference in maximum updrafts of tracked cells is shown between the clean and polluted simulations in the early stages of the cloud lifetimes. This demonstrates the importance of obtaining accurate estimates of vertical velocity from observations if aerosol impacts are to be properly resolved. Second, tracking of individual cells and using vertical cross section scanning every minute capture the evolution of precipitation particle number concentration and size represented by polarimetric observables better than the operational radar observations that update the volume scan every 5 min. This approach also improves multi-Doppler radar updraft retrievals above 5 km above ground level for regions with updraft velocities greater than 10 m s−1. Third, we propose an optimized strategy composed of cell tracking by quick (1–2 min) vertical cross section scans from more than one radar in addition to the operational volume scans. We also propose the use of a single-RHI (range height indicator) updraft retrieval technique for cells close to the radars, for which multi-Doppler radar retrievals are still challenging. Finally, increasing the number of deep convective cells sampled by such observations better represents the median maximum updraft evolution with sample sizes of more than 10 deep cells, which decreases the error associated with sampling the true population to less than 3 m s−1.

54 ENVIRONMENTAL SCIENCES↗

A multi-modal scanning system to digitize CBRNE emergency response scenes

A handheld system developed to digitize a contextual understanding of the scene at a chemical, biological, radiological, nuclear and/or explosives (CBRNE) events is described. The system uses LiDAR and cameras to create a colorized 3D model of the environment, which helps domain experts that are supporting responders in the field. To generate the digitized model, a responder scans any suspicious objects and the surroundings by carrying the system through the scene. The scanning system provides a real-time user interface to inform the user about scanning progress and to indicate any areas that may have been missed either by the LiDAR sensors or the cameras. Currently, the collected data are post-processed on a different device, building a colorized triangular mesh of the encountered scene, with the intention of moving this pipeline to the scanner at a later point. The mesh is sufficiently compressed to be sent over a reduced bandwidth connection to a remote analyst. Furthermore, the system tracks fiducial markers attached to diagnostic equipment that is placed around the suspicious object. The resulting tracking information can be transmitted to remote analysts to further facilitate their supporting efforts. The paper will discuss the system's design, software components, the user interface used for scanning a scene, the necessary procedures for calibration of the sensors, and the processing steps of the resulting data. The discussion will close by evaluating the system's performance on 11 scenes.

Prins, Nicholas↗

Use of the Manuela 3D/Radiation Scanning Tool at Nuclear Facilities - 20437

Licensees, facility operators and decommissioning contractors have a need for comprehensive, accurate and precise radiological and topographical data to plan and execute safe and efficient Decontamination and Decommissioning (D and D) projects. Traditional approaches rely greatly upon labor and administratively intensive data collection methods that require considerable time and effort to glean the relevant data to plan and perform work in a radiological work area. Orano Decommissioning Services has developed and utilized at French nuclear facilities a lightweight portable scanning instrument called MANUELA (Mobile Apparatus for Nuclear Expertise Localization Assistance). Recently Orano conducted demonstrations at two United States nuclear facilities using MANUELA that may prove useful in areas of the fuel cycle including: - ALARA (As Low As Reasonably Achievable) planning during facility operations; - Scoping and site characterization during the D and D planning phase; - Remedial action support during active decommissioning work; - Radiation and modeling planning for plant modifications; - Support Final Status Survey and demonstration of 'end state' compliance for license termination. MANUELA is currently being evaluated for use during decommissioning of nuclear facilities and could aide in demonstrating compliance with end state criteria after decommissioning. Of particular interest are decommissioning projects planned for various sites across the United States. Most of these sites present unique challenges and opportunities to safely and efficiently decommission in a regulatory compliant manner. The two demonstration site's current conditions of relatively low radiation levels inside containment proved to be ideal platforms to deploy the MANUELA instrument for evaluation of the complex geometries typically found in a nuclear facility. The MANUELA instrument was able to precisely identify local hot spots of the reactor system's primary equipment and was able to simultaneously overlay the dose information onto the scanned 3D images. Using data like this, a licensee would be able to make informed technical and personnel decisions on methods to remediate, shield or properly dispose of the radioactive source term. MANUELA can be used throughout the decommissioning process to validate progress and continue to refine the work activities to optimize the efforts of the crew which reduces downtime waiting for survey results, whereas traditional survey methodology relies on a physical survey to be performed and the data transcribed onto survey maps that are only two dimensional. The traditional format tends to be inaccurate and difficult to interpret the precise location(s) of hot spots or generalized dose rates. The resultant scan also allows the user to know the exact extent of the survey versus transposing information onto a map with only a portion of the map area scanned. MANUELA also compiles all of the relevant survey data into a downloadable table format which includes the measurement identification number, time stamp, point space location on the XYZ plane, and the dose rate value. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Designing Track for Electrospinning Unit and Cost-Effective Laser Scanning System

Nanofibers are produced in the Targeted Systems Department (TSD) by applying a large voltage to the nanofiber fluid and the collection apparatus known as the electrospinner. The fiber is then shot out of nozzles and collected onto the electrospinner into a nanofiber mat. The problem is that since the nozzle heads are stationary, there is non-uniform deposition of nanofiber on the collection drum leading to variation in thickness of the produced nanofiber mat. To mitigate this issue, a reciprocating mechanism is designed to move the nozzle along the drum collector along with the ability to vary its stroke length. This design was realized using Siemens NX and several parts were printed using a 3D printer, but is, as of writing, untested. Second project involved providing an alternative method to scan a large sample that had undergone certain surface deformation by beam interaction and detect out of plane deformation such as micro-scale swelling and surface roughness. Systems to carry out this scanning already exist; however, they are expensive and produce many files that need to be stitched together and are cumbersome to deal with. The solution is to create a scanning system using an already purchased scanning laser and linear stage motor. The laser and stage motor were combined to produce length results that aligned with a digital microscope but differing height results.

Ruffolo, Leopoldo↗

Designing a track for an electrospinning unit and cost-effective laser scanning system

Nanofibers are produced in the Targeted Systems Department (TSD) by applying a large voltage to the nanofiber fluid and the collection apparatus known as the electrospinner. The fiber is then shot out of nozzles and collected onto the electrospinner into a nanofiber mat. The problem is that since the nozzle heads are stationary, there is non-uniform deposition of nanofiber on the collection drum leading to variation in thickness of the produced nanofiber mat. To mitigate this issue, a reciprocating mechanism is designed to move the nozzle along the drum collector along with the ability to vary its stroke length. This design was realized using Siemens NX and several parts were printed using a 3D printer, but is, as of writing, untested. Second project involved providing an alternative method to scan a large sample that had undergone certain surface deformation by beam interaction and detect out of plane deformation such as micro-scale swelling and surface roughness. Systems to carry out this scanning already exist; however, they are expensive and produce many files that need to be stitched together and are cumbersome to deal with. The solution is to create a scanning system using an already purchased scanning laser and linear stage motor. The laser and stage motor were combined to produce length results that aligned with a digital microscope but differing height results.

Ruffolo, Leopoldo↗

Characterization of Two Fast-Turnaround Dry Dilution Refrigerators for Scanning Probe Microscopy

Low-temperature scanning probe microscopes (SPMs) are critical for the study of quantum materials and quantum information science. Due to the rising costs of helium, cryogen-free cryostats have become increasingly desirable. However, they typically suffer from comparatively worse vibrations than cryogen-based systems, necessitating the understanding and mitigation of vibrations for SPM applications. Here, in this work, we demonstrate the construction of two cryogen-free dilution refrigerator SPMs with minimal modifications to the factory default and we systematically characterize their vibrational performance. We measure the absolute vibrations at the microscope stage with geophones and use both microwave impedance microscopy and a scanning single-electron transistor to independently measure tip-sample vibrations. Additionally, we implement customized filtering and thermal anchoring schemes and characterize the cooling power at the scanning stage and the tip electron temperature. This work serves as a reference to researchers interested in cryogen-free SPMs, as such characterization is not standardized in the literature or available from manufacturers.

36 MATERIALS SCIENCE↗

Controlling mechanical properties of laser powder bed fused AlSi10Mg through manipulation of laser scan rotation

The microstructure and mechanical properties of laser powder bed fused (LPBF) AlSi10Mg alloys can be controlled by many processing parameters. This study focuses on the scan rotation angle, α, between adjacent layers, and establishes the relationship between α and tensile behavior of the as-built LPBF-processed AlSi10Mg alloy. Near-full density cubic coupons were manufactured using the same processing parameters but with systematic variation of α from 0° to 90°. Microscopic observations and X-ray diffraction analysis showed that differences among various coupons mainly include orientations of the melt pools with respect to the build direction and development of the crystallographic texture. The α=0° coupon and α=30° coupon showed the highest and lowest texture index, although the overall crystallographic texture was mild. Tensile specimens were manufactured horizontally and vertically using either α=0° or α=30°, but with various first layer laser direction with respect to the build plate. Notably, the α=0° specimen that was tested along the laser scan direction showed the largest yield strength (283 MPa) and highest tensile ductility (10.1 %). Quantitative image analysis and fractography were performed on all specimens. Results showed that the melt pool orientation with respect to the tensile direction affected the tensile behavior across the different specimens. This was closely related to the localized strain distribution within the melt pool and along the melt pool boundary for the different melt pool orientations observed. Further, these results demonstrate that the laser scan rotation angle between layers can be used to fine tune the mechanical properties of LPBF AlSi10Mg alloy.

36 MATERIALS SCIENCE↗

Voltage scanning and technical upgrades at the Collinear Resonance Ionization Spectroscopy experiment

To optimize the performance of the Collinear Resonance Ionization Spectroscopy (CRIS) experiment at CERN-ISOLDE, technical upgrades are continuously introduced, aiming to enhance its sensitivity, precision, stability, and efficiency. Recently, a voltage-scanning setup was developed and commissioned at CRIS, which improved the scanning speed by a factor of three as compared to the current laser-frequency scanning approach. This leads to faster measurements of the hyperfine structure for systems with high yields (more than a few thousand ions per second). Additionally, several beamline sections have been redesigned and manufactured, including a new field-ionization unit, an electrostatic bend with a larger deflection angle, and improved ion optics. The beamline upgrades are expected to yield an improvement of at least a factor of 5 in the signal-to-noise ratio by avoiding the use of high-power lasers (which yield non-resonantly produced ions) and providing time-of-flight separation between the resonant ions and the collisional background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scanning Tunneling Thermometry

The best spatial resolution so far achieved in thermal imaging is several nanometers, much coarser than routinely achieved for other physical properties. Here we propose a method to map electronic temperature variations in operating nanoscale conductors by relying solely upon electrical tunneling current measurements. The proposed measurement scheme involves two scanning probe operations to measure the conductance and thermopower, respectively. These two measurements are shown to determine the local temperature with high accuracy in nanoscale conductors, where the Wiedemann-Franz law holds quite generally. We report the proposed scanning tunneling thermometer, owing to its operation in the tunneling regime, would be capable of mapping temperature variations with subnanometer resolution, thereby enhancing the resolution of scanning thermometry by some 2 orders of magnitude.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Coupling Pulse Radiolysis with Nanosecond Time-Resolved Step-Scan Fourier Transform Infrared Spectroscopy: Broadband Mid-Infrared Detection of Radiolytically Generated Transients

We describe the first implementation of broadband, nanosecond time-resolved step-scan Fourier transform infrared (S 2 -FT-IR) spectroscopy at a pulse radiolysis facility. This new technique allows the rapid acquisition of nano- to microsecond time-resolved infrared (TRIR) spectra of transient species generated by pulse radiolysis of liquid samples at a pulsed electron accelerator. Wide regions of the mid-infrared can be probed in a single experiment, which often takes < 20–30 min to complete. It is therefore a powerful method for rapidly locating the IR absorptions of short-lived, radiation-induced species in solution, and for directly monitoring their subsequent reactions. Time-resolved step-scan FT-IR detection for pulse radiolysis thus complements our existing narrowband quantum cascade laser-based pulse radiolysis-TRIR detection system, which is more suitable for acquiring single-shot kinetics and narrowband TRIR spectra on small-volume samples and in strongly absorbing solvents, such as water. We have demonstrated the application of time-resolved step-scan FT-IR spectroscopy to pulse radiolysis by probing the metal carbonyl and organic carbonyl vibrations of the one-electron-reduced forms of two Re-based CO 2 reduction catalysts in acetonitrile solution. Transient IR absorption bands with amplitudes on the order of 1 × 10 −3 are easily detected on the sub-microsecond timescale using electron pulses as short as 250 ns.

(S2-FT-IR)↗

Mechanical Solutions Scan Report

Power lines, poles, and towers are the backbone of the United States (U.S.) electric-power grid. These transmission and distribution networks route electricity from generator to loads. The characteristics of these routes are rapidly changing -- trending towards decentralized renewable generation, electric heating, vehicle charging, and large data-center loads. Coupled with aging infrastructure and the increased frequency of extreme weather events, there is concern about the future reliability and transmission capacity of conductors and adjacent components. This scan report seeks to provide an overview of mechanical solutions to challenges caused by extreme weather events associated with components of transmission and distribution infrastructure, including conductor heat sag, ice accumulation, wind, and wildfire. Many options could increase transmission capacity or reliability, and these are at various stages of technological readiness. Some have only been lab tested, while some have been widely deployed in the U.S. or overseas for decades. The solution categories and providers featured in this report are intended to be comprehensive at the time of publication and to serve as a reference for decision-makers concerned about transmission and distribution reliability. There are two other categories of large, complex solutions, which are not covered in this report: replacing existing conductors with advanced conductors and implementing digital grid enhancing technologies. A separate scan report titled “Advanced Conductor Scan Report,” which discusses advanced carbon-core conductors, was published by the Idaho National Laboratory (INL) in 2023. Information on digital technologies, such as dynamic line ratings, power-flow controllers, and other power electronics and communications-based devices, can be found on the Grid- Enhancing Technologies landing page. Mechanical grid-enhancing technologies, or solutions covered in this report, often do not require full equipment replacement and do not rely on digital components. Mechanical technologies are overlooked because they may be older, simpler, or seemingly “more obvious” than digital or carbon-core technologies. However, it is wise to consider mechanical solutions in a thorough evaluation of grid enhancing technology solutions.

24 - POWER TRANSMISSION AND DISTRIBUTION↗