Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample preparation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The Laser Ablation Ion Funnel: Sampling for in situ Mass Spectrometry on Mars

A considerable investment has been made by NASA and other space agencies to develop instrumentation suitable for in situ analytical investigation of extra terrestrial bodies including various mass spectrometers (time-of-flight, quadrupole ion trap, quadrupole mass filters, etc.). However, the front-end sample handling that is needed to collect and prepare samples for interrogation by such instrumentation remains underdeveloped. Here we describe a novel approach tailored to the exploration of Mars where ions are created in the ambient atmosphere via laser ablation and then efficiently transported into a mass spectrometer for in situ analysis using an electrodynamic ion funnel. This concept would enable elemental and isotopic analysis of geological samples with the analysis of desorbed organic material a possibility as well. Such an instrument would be suitable for inclusion on all potential missions currently being considered such as the Mid-Range Rover, the Astrobiology Field Laboratory, and Mars Sample Return (i.e., as a sample pre-selection triage instrument), among others.

Johnson, Paul V.↗

An Examination of the Space Weathering Patina of Lunar Rock 76015

Space weathering discussions have generally centered around soils but exposed rocks will also incur the effects of weathering. Rocks have much longer surface lifetimes than an individual soil grain and thus record a longer history of exposure. By studying the weathering products which have built up on a rock surface, we can gain a deeper perspective on the weathering process and better assess the relative importance of various weathering components. The weathered coating, or patina, of the lunar rock 76015 has been previously studied under SEM and also by TEM using ultramicrotome sample preparation methods. However, to really understand the products involved in creating these coatings, it is helpful to examine the patina in cross section, something which is now possible though the use of Focused Ion Beam (FIB) sample prep techniques, which allows us to preserve intact the delicate stratigraphy of the patina coating and provides a unique cross-sectional view of the space weathering process. Several samples have been prepared from the rock and the coatings are found to be quite variable in thickness and composition from one sample to the next.

Noble, S.↗

A Novel Hybrid Ultramicrotomy/FIB-SEM Technique: Preparation of Serial Electron-Transparent Thin Sections of a Hayabusa Grain

The Japanese space agency's (JAXA) Hayabusa mission returned the first particulate samples (typically <100micron) from the surface of an asteroid (25143 Itokawa). These precious samples provide important insights into early Solar System processes, but their sizes pose tremendous challenges to coordinated analysis using a variety of nano- and micro-beam techniques. The ability to glean maximal information from individual particles has become increasingly important and depends critically on sample preparation. We developed a hybrid technique combining traditional ultramicrotomy with focused ion beam (FIB) techniques, allowing for more thorough in situ investigations of grain surfaces and interiors. Using this method, we increase the number of FIB-prepared sections that can be recovered from a particle with dimensions on the order of tens of microns. These sections can be subsequently analyzed using a variety of analytical techniques. Particle RA-QD02-0211 is a approx. 40×40×20 micron particle from Itokawa containing olivine and Fe sulfides. It was embedded in low viscosity epoxy and partly sectioned to a depth of approx 10 micron; sections are placed on Cu grids with thin amorphous films for transmission electron microscope (TEM) analyses. With the sample surface partly exposed, the epoxy bullet is trimmed to a height of approx. 5mm to accommodate the allowable dimensions for FIB work (FEI Quanta 600 3D dual beam FIB-SEM). Using a diamond trim knife, the epoxy surrounding the grain is removed on 3 sides (to within a few microns of the grain); the depth of material removed extends well below the bottom of the particle. The sample is attached to an SEM pin mount, the epoxy coated with conductive paint, and the entire assembly coated with approx. 40nm of carbon to eliminate sample charging during FIB work. A protective carbon cap is placed according to the plan for the 15 FIB sections. The central 'spine' of the cap runs perpendicular to the front of the sample, and the 'ribs' protruding from either side run parallel. Each rib indicates the location of a planned FIB section, and the spine contains the final two planned sections. We use a cap with a 4 micron-wide spine and 2micron-wide ribs that have ≳3.5 micron of space between them (narrower cuts result in too much re-deposition of material inside the trenches). Using a 30kV, 3nA ion-beam we expose the front surface of the grain and commence milling trenches between sections. Rather than using the typical C-cut to prepare the sample for lift-out, an L-cut is used instead, leaving the sample connected by an interior tab. tab. Sections are lifted out, attached to TEM grids and thinned to electron transparency. TEM analyses show that our hybrid technique preserves both interior and edge features, including surface modifications from exposure to the space environment, such as damaged rims that form in response to solar wind implantation effects and adhering grains. In addition, the FIB sections provide larger areas that are free of fractures and chatter effects in comparison to the microtome thin sections, thus enabling more accurate measurements of solar flare particle track densities that are used to determine the surface exposure age of the particles.

Berger, Eve L.↗

Advanced Curation Activities at NASA: Preparation for Upcoming Missions

The responsibility for curating NASA's astromaterials collections falls to the NASA Curation Office at Johnson Space Center. Under the governing document, NASA Policy Directive (NPD) 7100.10F and derivative requirements documents, JSC is charged with curation of all extraterrestrial material under NASA control, including future NASA missions to include material returned in Mars Sample Return (MSR) efforts, OSIRIS-REx, NASA's subset of Hayabusa-2 samples, and any other sample return missions. The Directive defines Curation as activities including documentation, preservation, sample preparation, distribution, and tracking of samples for research, education, and public outreach. In this abstract we will describe Curation's research and development efforts to improve the care of existing collections and prepare for future NASA sample return missions. These efforts are collectively referred to as Advanced Curation, a term first coined in 2002.

Fries, M. D.↗

Effects of multifunctional crosslinking agents on the thermomechanical properties of polyimide films

The potential of high temperature resistant polymers such as polyimides (PI) and polyphenylquinoxalines (PPQ) as matrix resins in fiber-reinforced composites has not been fully realized to date. One of the problems associated with these resins is that they exhibit creep, or thermoplastic yielding under load at temperatures approaching 316 C (600 F). The purpose of this investigation was to further reduce thermoplastic behavior of polyimide resins by substituting a controlled amount of the diamine monomer with crosslinking agents having a higher amine functionality. The knowledge gained from a study of the thermomechanical properties of the crosslinked resins would then be used in the fabrication of fiber-reinforced polyimide composites. This report describes the synthesis and characterization of three new polyfunctional amines. Polyimide films containing varying amounts of the cross-linking agents were prepared, and their properties compared with those of control samples prepared with difunctional amines. The effect of crosslink density on isothermal weight loss, polymer softening, and glass transition temperatures is discussed.

Delvigs, P.↗

Determination of oxygen in silicon and carbide by activation with 27.2 meV alpha particles

The Si sample was polished on one side, and on the other side Ni was applied chemically and soldered with Pb to a water cooled Cu substrate. Optical quartz standard was fixed from the other side. Si carbide samples were soldered to a substrated with In. The prepared samples were irradiated in a cyclotron with a 27.2 MeV alpha particle beam. The layers were removed from the Si and Si carbide samples by grinding and the positron activity of F-18(t sub 1/2 110 min) was measured by using a gamma, gamma coincidence spectrometer with two NaI(TI) crystals. For analysis of Si carbide, the activity decay curve of the samples was recorded to find the contribution of the positron activity of Cu-65(t sub 1/2 12.9 hr) which formed from Ni impurity on irradiation.

Dolgolenko, A. P.↗

Materials processing in low gravity

Activities of the Materials Processing in Low Gravity Program in which the University of Alabama in Huntsville (UAH) designed, fabricated, and performed various low gravity experiments in materials processing between October 26, 1988 through October 25, 1989 are discussed. Details of low gravity experiments using the Drop Facilities at the Marshall Space Flight Center (MSFC) and the KC-135 aircraft at Ellington Field are discussed. This effort included the defining of experimental requirements and equipment, experiment-facility integration requirements, building/assembling the necessary experiment apparatus, and conducting experiments which will contribute to the knowledge base for commercialization of materials processing in low gravity. UAH also performed logistical support needed to execute the experimentation, the necessary sample preparation, metallography analysis, and physical properties measurements of the processed samples.

Workman, Gary L.↗

Use of electron microprobe x-ray analysis for determination of low calcium concentrations across leaves deficient in calcium

An electron microprobe with wavelength-dispersive x-ray spectrometry (WDS) was found to be useful for the determination of Ca concentrations in leaf tissue deficient in Ca. WDS effectively detected Ca concentrations as low as 0.2 mg/g dry wt in the presence of high levels of K and Mg (120 and 50 mg/g dry wt, respectively). Leaf specimens were prepared for analysis by quick-freezing in liquid nitrogen and freeze-drying at -20 degrees C to maintain elemental integrity within the tissue. Because dry material was analyzed, sample preparation was simple and samples could be stored for long periods before analysis. A large beam diameter of 50 gm was used to minimize tissue damage under the beam and analyze mineral concentrations within several cells at one time. Beam penetration was between 50 and 55 microns, approximately one-third of the thickness of the leaf. For analysis of concentrations in interveinal areas, analyses directed into the abaxial epidermis were found most useful. However, because of limited beam penetration, analyses of veinal areas would require use of cross sections [correction of crosssections]. Solid mineral standards were used for instrument standardization. To prevent measurement errors resulting from differences between the matrix of the mineral standards and the analyzed tissue, concentrations in leaves were corrected using gelatin standards prepared and analyzed under the same conditions. WDS was found to be useful for documenting that very low Ca levels occur in specific areas of lettuce leaves exhibiting the Ca deficiency injury termed tipburn.

Non-NASA Center↗

Effects of multifunctional crosslinking agents on the thermomechanical properties of polyimide films

Three polyfunctional amines were synthesized. Polyimide films containing varying amounts of the amine crosslinking agents were prepared. Their thermomechanical properties were compared with those of control film samples prepared from difunctional amines. The effect of crosslink density on isothermal weight loss, polymer softening, and glass transition temperature is discussed.

Delvigs, P.↗

Adhesive bond evaluation using phase sensitive detection techniques

Quadrature phase detection techniques have been used to monitor the amplitude and phase of a toneburst ultrasonic wave normally reflected from adhesively-bonded steel/rubber interface. The measured phase change values of the reflected signals were found to correlate with variations in sample preparation. It was determined that measured phase shift changes were larger for samples with weaker bonds as manifested by smaller measured values of the applied tensile loads at failure. A model calculation which incorporates the concept of interfacial strength into the usual problem of wave propagation in multi-layered isotropic elastic media was used to deduce a bond-quality parameter from an experimentally measured phase shift.

Smith, Alphonso C.↗

Prototype Backscatter Moessbauer Spectrometer for Measurement of Martian Surface Mineralogy

We have designed and successfully tested a prototype of a backscatter Moessbauer spectrometer (BaMS) targeted for use on the Martian surface to (1) determine oxidation states of iron, and (2) identify and determine relative abundances of iron-bearing mineralogies. No sample preparation is required to perform measurements; it is only necessary to bring sample and instrument into physical contact. The prototype meets our projected specification for a flight instrument in terms of mass, power, and volume. A Moessbauer spectrometer on the Martian surface would provide wide variety of information about the current state of the Martian surface, and this information is described.

Shelfer, T. D.↗

Miniature Mass Spectrometers on Space and Planetary Missions

Space flight mass spectrometers contribute our understanding of the origin and evolution of our solar system and even of life itself. This fundamental role has motivated increasing interest in miniature mass spectrometry for planetary missions. Several remarkable new instruments are en route or under development to investigate the composition of planetary bodies such as Mars and comets. For instance, the Sample Analysis at Mars (SAM) suite on the 2009 Mars Science Laboratory (MSL) mission includes a quadrupole mass spectrometer with a sophisticated gas processing system as well as pyrolysis and chemical derivatization protocols for solid samples. Future missions will require even lighter, lower power, and yet more capable mass spectrometers, particularly to analyze samples in situ on planetary surfaces. We have been developing laser-based mass spectrometers for elemental and organic/molecular analysis of rock, ice, or fine particle samples. These typically use time-of-flight (TOF) mass analyzers, which are readily miniaturized and can detect both atomic species and complex organics that occur in a variety of planetary materials. For example, nonvolatile polycyclic aromatic hydrocarbons and kerogen-like macromolecular carbon are found in some carbonaceous meteorites, which derived from asteroid parent bodies. A single focused laser pulse is able to volatilize and ionize some of these compounds for direct TOF analysis. While this is possible without any sample preparation or contact, sensitivity and quantitative performance can improve significantly with some sample handling. As such we have also been examining robotic mechanisms and protocols to accompany space flight mass spectrometers. In addition, sensors in early development may significantly improve these capabilities, via use of techniques such as switchable polarity, ambient pressure, or resonant ionization; tandem mass spectrometry (TOF or ion trap); and chemical imaging.

Brinckerhoff, William↗

Non-Contact Thermal Properties Measurement with Low-Power Laser and IR Camera System

As shown by the Phoenix Mars Lander's Thermal and Electrical Conductivity Probe (TECP), contact measurements of thermal conductivity and diffusivity (using a modified flux-plate or line-source heat-pulse method) are constrained by a number of factors. Robotic resources must be used to place the probe, making them unavailable for other operations for the duration of the measurement. The range of placement is also limited by mobility, particularly in the case of a lander. Placement is also subject to irregularities in contact quality, resulting in non-repeatable heat transfer to the material under test. Most important from a scientific perspective, the varieties of materials which can be measured are limited to unconsolidated or weakly-cohesive regolith materials, rocks, and ices being too hard for nominal insertion strengths. Accurately measuring thermal properties in the laboratory requires significant experimental finesse, involving sample preparation, controlled and repeatable procedures, and, practically, instrumentation much more voluminous than the sample being tested (heater plates, insulation, temperature sensors). Remote measurements (infrared images from orbiting spacecraft) can reveal composite properties like thermal inertia, but suffer both from a large footprint (low spatial resolution) and convolution of the thermal properties of a potentially layered medium. In situ measurement techniques (the Phoenix TECP is the only robotic measurement of thermal properties to date) suffer from problems of placement range, placement quality, occupation of robotic resources, and the ability to only measure materials of low mechanical strength. A spacecraft needs the ability to perform a non-contact thermal properties measurement in situ. Essential components include low power consumption, leveraging of existing or highly-developed flight technologies, and mechanical simplicity. This new in situ method, by virtue of its being non-contact, bypasses all of these problems. The use of photons to both excite and measure the thermal response of any surface material to a high resolution (estimated footprint = 10 square centimeters) is a generational leap in physical properties measurements. The proposed method consists of spot-heating the surface of a material with a low (less than 1 W) power laser. This produces a moderate (5-10 K) temperature increase in the material.

Hudson, Troy L.↗

Changes in Black Carbon Deposition to Antarctica from Two Ice Core Records, A.D. 1850-2000

Continuous flow analysis was based on a steady sample flow and in-line detection of BC and other chemical substances as described in McConnell et al. (2007). In the cold room, previously cut one meter ice core sticks of 3x3cm, are melted continuously on a heated melter head specifically designed to eliminate contamination from the atmosphere or by the external parts of the ice. The melted ice from the most inner part of the ice stick is continuously pumped by a peristaltic pump and carried to a clean lab by Teflon lines. The recorded signal is continuous, integrating a sample volume of about 0.05 mL, for which the temporal resolution depends on the speed of melting, ice density and snow accumulation rate at the ice core drilling site. For annual accumulation derived from the WAIS and Law Dome ice cores, we assumed ~3.1 cm water equivalent uncertainty in each year's accumulation from short scale spatial variability (glaciological noise) which was determined from several measurements of annual accumulation in multiple parallel ice cores notably from the WAIS Divide ice core site (Banta et al., 2008) and from South Pole site (McConnell et al., 1997; McConnell et al., 2000). Refractory black carbon (rBC) concentrations were determined using the same method as in (Bisiaux et al., 2011) and adapted to continuous flow measurements as described by (McConnell et al., 2007). The technique uses a single particle intracavity laser induced incandescence photometer (SP2, Droplet Measurement Technologies, Boulder, Colorado) coupled to an ultrasonic nebulizer/desolvation (CETAC UT5000) Flow Injection Analysis (FIA). All analyses, sample preparation etc, were performed in a class 100 cleanroom using anti contamination "clean techniques". The samples were not acidified.

Bisiaux, Marion M.↗

Pressure dependence of the electrical properties of GaBi solidified in low gravity

Immiscible GaBi alloys were solidified during free fall in the NASA Marshall Space Flight Center drop tower, which provides about 4.5 seconds of low gravity. The electrical resistivity and magnetic susceptibility were measured as a function of pressure (up to 18 kbar) and temperature (300 K to 4.2 K) of drop tower (DT) and ground control (GC) samples prepared under identical conditions, except for gravity. At ambient pressure the electrical resistance of the DT sample exhibits a broad maximum at 100 K, while that of GC sample decreases rapidly as temperature decreases. Both DT and GC samples become superconducting at 7.7 K. However, a minor second superconducting phase with a transition temperature at 8.3 K is observed only in the DT samples.

Wu, M. K.↗

A Modified LC/MS/MS Method with Enhanced Sensitivity for the Determination of Scopolamine in Human Plasma

Intranasal scopolamine is a choice drug for the treatment of motion sickness during space flight because of its quick onset of action, short half-life and favorable sideeffects profile. The dose administered usually ranges between 0.1 and 0.4 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids using existing sensitive LC/MS/MS method, especially when the biological sample volumes are limited. To measure scopolamine in human plasma to facilitate pharmacokinetic evaluation of the drug, we developed a sensitive LC/MS/MS method using 96 well micro elution plates for solid phase extraction (SPE) of scopolamine in human plasma. Human plasma (100-250 micro L) were loaded onto Waters Oasis HLB 96 well micro elution plate and eluted with 50 L of organic solvent without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 3 minutes. The mobile phase for separation was 80:20 (v/v) methanol: ammonium acetate (30 mM) in water. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 right arrow 138.1 and internal standard hyoscyamine m/z = 290.2 right arrow 124.1. The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at about 1.1 and 1.7 min respectively. The linear range is 25-10000 pg/mL for scopolamine in human plasma with correlation coefficients greater than 0.99 and CV less than 0.5%. The intra-day and inter-day CVs are less than 15% for quality control samples with concentrations of 75,300, and 750 pg/mL of scopolamine in human plasma. SPE using 96 well micro elution plates allows rapid sample preparation and enhanced sensitivity for the LC/MS/MS determination of scopolamine in a small volume of biological samples. The new method is also cost effective since it uses a small volume of organic solvents compared to the methods using SPE cartridges or regular 96 well SPE plates. This method can be successfully used for bioavailability and pharmacokinetic evaluations of scopolamine, especially when volumes of biological samples are limited. Further investigation to use automated SPE system with 96 well micro elution plates is planned.

Wang, Zuwei↗

Fluid Inclusions in Extraterrestrial Samples: Failures, Successes, Possibilities, and A Note of Caution

Over the past half century the search for life in the solar system and beyond has become a major research focus, with much effort devoted to finding evidence for liquid H2O and reduced carbon-bearing (organic) species in extraterrestrial samples. The most direct and convincing evidence for the presence of water and organic molecules is provided by fluid inclusions (FI)trapped in minerals that formed on the parent bodies. Beginning in the 1970s, reports of FI in extraterrestrial samples generated much enthusiasm within the planetary sciences community. However, many of the reported FI were determined to be artifacts of sample preparation, or incomplete characterization of features that appear to be FI, or were inconsistent with the inferred PT history of the meteorite sample. An early report of aqueous (and hydrocarbon-bearing) FI in stony meteorites and the subsequent follow-up study that showed that most or all of the “FI” contained water used during cutting and polishing of the samples led to a general unwillingness to believe later reports of FI in meteorites. One of the first confirmed occurrences of extraterrestrial aqueous (liquid) fluid inclusions in a meteorite was reported by Zolensky et al. (1999; Science), who described aqueous inclusions in halite in the Monahans and later the Zag meteorites. These meteorite falls were collected shortly after landing on earth and were prepared without using water or other fluids that could introduce artifacts. The oxygen and hydrogen isotopic composition of water in FI in these same samples was later measured, showing that the fluids represent various degrees of water-rock interaction on the parent body .In more recent years, careful studies of FI trapped in extraterrestrial samples combining synchrotron X-ray computed tomography to locate FI in samples followed by cryo-TOF-SIMS analysis of the FI have identified the presence of molecular fragments suggesting the presence of H2O and various organic molecules in the fluids. Challenges associated with studying FI in extraterrestrial samples include the limited abundance of potential host phases for FI, such as carbonates and phosphates, the often poor optical quality of the host phases, and the small size of the FI, with few as large as 5 microns and most less than 1-2 microns in maximum dimension

Robert Bodnar↗

Trace-element analysis of 1000 environmental samples per year using instrumental neutron activation analysis

The technology and methods developed at the Plum Brook Reactor to analyze 1000 samples per year and report data on as many as 56 elements are described. The manpower for the complete analysis of 20 to 24 samples per week required only 3 to 3.5 hours per sample. The solutions to problems encountered in sample preparation, irradiation, and counting are discussed. The automation of data reduction is described. Typical data on various sample matrices are presented.

Sheibley, D. W.↗