Direct Observation of Ultralow Vertical Emittance using a Vertical Undulator

In recent work, the first quantitative measurements of electron beam vertical emittance using a vertical undulator were presented, with particular emphasis given to ultralow vertical emittances [K. P. Wootton, et al., Phys. Rev. ST Accel. Beams, 17, 112802 (2014)]. Using this apparatus, a geometric vertical emittance of 0.9 ± 0.3 pm rad has been observed. A critical analysis is given of measurement approaches that were attempted, with particular emphasis on systematic and statistical uncertainties. The method used is explained, compared to other techniques and the applicability of these results to other scenarios discussed.

43 PARTICLE ACCELERATORS↗

Observation of Coherent Optical Transition Radiation in the LCLS Linac

The beam diagnostics in the linac for the Linac Coherent Light Source (LCLS) X-ray FEL project at SLAC includes optical transition radiation (OTR) screens for measurements of transverse and longitudinal beam properties. We report on observations of coherent light emission from the OTR screens (COTR) at visible wavelengths from the uncompressed and compressed electron beam at various stages in the accelerator.

43 PARTICLE ACCELERATORS↗

Using Beam Echo Effect for Generation of Short-Wavelength Radiation

We propose to use an echo effect previously observed in hadron accelerators for up-frequency conversion of density modulation in an electron beam. We show that, for generation of high harmonics, this method is much more efficient in comparison with the currently used approach. A one dimensional model of the effect is developed which allows to optimize the amplitude of the modulation for a given harmonic number.

43 PARTICLE ACCELERATORS↗

An Optimal Exposure Strategy for Cryoprotected Virus Crystals With Lattice Constants Greater Than 1000 Angstrom

Studies of icosahedral virus capsids provide insights into the function of supramolecular machines. Virus capsid crystals have exceptionally large unit cells; as a result, they diffract weakly compared with protein crystals. HK97 is a dsDNA lambda-like bacteriophage whose 13 MDa capsid expands from 550 {angstrom} to 650 {angstrom} with large subunit conformational changes during virus maturation. The HK97 penultimate maturation intermediate was crystallized in a tetragonal unit cell that has lattice constants of 1010 {angstrom} x 1010 {angstrom} x 730 {angstrom}. The crystals could be cryoprotected, but diffracted to a modest resolution of 5 {angstrom} at a bending-magnet beamline. When these crystals were optimally exposed with two orders-of-magnitude more photons from a new insertion-device beamline, data extending to better than 3.8 {angstrom} resolution were obtained. Here, the strategies to collect and process such data are described. These strategies can be adapted for other crystals with large unit cells and for microcrystals.

59 BASIC BIOLOGICAL SCIENCES↗

Reduction of Beam Emittance of Pep-X Using Quadruple Bend Achromat Cell

SLAC National Accelerator Laboratory is studying an option of building a high brightness synchrotron light source machine, PEP-X, in the existing PEP-II tunnel [1, 2]. By replacing 6 arcs of FODO cells of PEPII High Energy Ring (HER) with two arcs of DBA and four arcs of TME and installation of 89.3 m long damping wiggler an ultra low beam emittance of 0.14 nm-rad (including intra-beam scattering) at 4.5 GeV is achieved. In this paper we study the possibility to further reduce the beam emittance by releasing the constraint of the dispersion free in the DBA straight. The QBA (Quadruple Bend Achromat) cell is used to replace the DBA. The ratio of outer and inner bending angle is optimized. The dispersion function in the non-dispersion straight is controlled to compromise with lower emittance and beam size at the dispersion straight. An undulator of period length 23 mm, maximum magnetic field of 1.053 T, and total periods of 150 is used to put in the 30 straights to simulate the effects of these IDs on the beam emittance and energy spread. The brightness including all the ID effects is calculated and compared to the original PEP-X design.

43 PARTICLE ACCELERATORS↗

Polarization Analysis of Nonlinear Harmonic Radiation in a Crossed-Planar Undulator

There is growing interest in producing intense, coherent x-ray radiation with an adjustable and arbitrary polarization state. The crossed-planar undulator, which was first proposed by Kim, could achieve rapid polarization control in synchrotron radiation sources and free electron lasers (FELs) through the manipulation of a phase shifter. Recently, a statistical analysis shows that a polarization degree of over 80% is obtainable for a Self-Amplified Spontaneous Emission (SASE) FEL near saturation. In such a scheme, nonlinear harmonic radiation is also generated in each undulator and the polarization of the radiation is controllable in the same manner. In this paper, we study the degree of polarization achievable at the third harmonic in a crossed-planar undulator. We also propose a method for generating second harmonic radiation with arbitrary polarization.

43 PARTICLE ACCELERATORS↗

The Attachment of Amino Fragment to Purine: Inner-Shell Structures And Spectra

The impact of the amino fragment (-NH{sub 2}) attachment on the inner-shell structures and spectra of unsubstituted purine and the purine ring of adenine are studied. Density functional theory calculations, using the LB94/TZ2P//B3LYP/TZVP model, reveal significant site-dependent electronic structural changes in the inner shell of the species. A condensed Fukui function indicates that all of the N and C sites, except for N{sub (1)} and C{sub (5)}, demonstrate significant electrophilic reactivity (f > 0.5 in |e|) in the unsubstituted purine. Once the amino fragment binds to the C{sub (6)} position of purine to form adenine, the electrophilic reactivity of these N and C sites is greatly reduced. As expected, the C{sub (6)} position experiences substantial changes in energy and charge transfer, owing to the formation of the C-NH{sub 2} bond in adenine. The present study reveals that the N1s spectra of adenine inherit the N1s spectra of the unsubstituted purine, whereas the C1s spectra experience significant changes although purine and adenine have geometrically similar carbon frames. The findings also indicate that the attachment of the NH{sub 2} fragment to purine exhibits deeply rooted influences to the inner-shell structures of DNA/RNA bases. The present study suggests that some fragment-based methods may not be applicable to spectral analyses in the inner shell.

59 BASIC BIOLOGICAL SCIENCES↗

LCLS Undulator Commissioning, Alignment, and Performance

The LCLS x-ray FEL has recently achieved its 1.5-Angstrom lasing and saturation goals upon first trial. This was achieved as a result of a thorough pre-beam checkout, both traditional and beam-based component alignment techniques, and high electron beam brightness. The x-ray FEL process demands very tight tolerances on the straightness of the electron beam trajectory (<5 {micro}m) through the LCLS undulator system. Tight, but less stringent tolerances of {approx}100 {micro}m rms were met for the transverse placement of the individual undulator segments with respect to the beam axis. The tolerances for electron beam straightness can only be met through a beam-based alignment (BBA) method, which is implemented using large electron energy variations and sub-micron resolution cavity beam position monitors (BPM), with precise conventional alignment used to set the starting conditions. Precision-fiducialization of components mounted on remotely adjustable girders, and special beam-finder wires (BFW) at each girder have been used to meet these challenging alignment tolerances. Longer-term girder movement due to ground motion and temperature changes are being monitored, continuously, by a unique stretched wire and hydrostatic level Alignment Diagnostics System (ADS).

43 PARTICLE ACCELERATORS↗

Experiences from First Top-Off Injection at the Stanford Synchrotron Radiation Lightsource

As the Stanford Synchrotron Radiation Lightsource (SSRL) of the SLAC National Accelerator Laboratory (SLAC) is moving toward Top-Off injection mode, SLAC's Radiation Protection Department is working with SSRL on minimizing the radiological hazards of this mode. One such hazard is radiation that is created inside the accelerator concrete enclosure by injected beam. Since during Top-Off injection the stoppers that would otherwise isolate the storage ring from the experimental area stay open, the stoppers no longer prevent such radiation from reaching the experimental area. The level of this stray radiation was measured in April 2008 during the first Top-Off injection tests. They revealed radiation dose rates of up to 18 microSv/h (1.8 millirem/h) outside the experimental hutches, significantly higher than our goal of 1 microSv/h (0.1 millirem/h). Non-optimal injection increased the measured dose rates by a factor two. Further tests in 2008 indicated that subsequent improvements by SSRL to the injection system have reduced the dose rates to acceptable levels. This presentation describes the studies performed before the Top-Off tests, the tests themselves and their major results (both under initial conditions and after improvements were implemented), and presents the controls being implemented for full and routine Top-Off injection.

43 PARTICLE ACCELERATORS↗

Operational Radiation Protection in Synchrotron Light and Free Electron Laser Facilities

The 3rd generation synchrotron radiation (SR) facilities are storage ring based facilities with many insertion devices and photon beamlines, and have low injection beam power (< few tens of watts), but extremely high stored beam power ({approx} 1 GW). The 4th generation x-ray free electron laser (FEL) facilities are based on an electron Linac with a long undulator and have high injection beam power (a few kW). Due to its electron and photon beam characteristics and modes of operation, storage ring and photon beamlines have unique safety aspects, which are the main subjects of this paper. The shielding design limits, operational modes, and beam losses are first reviewed. Shielding analysis (source terms and methodologies) and interlocked safety systems for storage ring and photon beamlines (including SR and gas bremsstrahlung) are described. Specific safety issues for storage ring top-off injection operation and FEL facilities are discussed. The operational safety program, e.g., operation authorization, commissioning, training, and radiation measurements, for SR facilities is also presented.

43 PARTICLE ACCELERATORS↗

HOM Sensitivity in the PEP-II HER Vacuum Chamber

Synchrotron radiation is the main source of vacuum chamber heating in the PEP-II storage ring collider. This heating is reduced substantially as lattice energy is lowered. Energy scans over {Upsilon} energy states were performed by varying the high energy ring (HER) lattice energy at constant gap voltage and frequency. We observed unexpected temperature rise at particular locations when HER lattice energy was lowered from 8.6 GeV ({Upsilon}(3S)) to 8.0 GeV ({Upsilon}(2S)) while most other temperatures decreased. Bunch length measurements reveal a shorter bunch at the lower energy. The shortened bunch overheated a beam position monitoring electrode causing a vacuum breach. We explain the unexpected heating as a consequence of increased higher order mode (HOM) power generated by a shortened bunch. In this case, temperature rise helps to identify HOM sources and HOM sensitive vacuum chamber elements. Reduction of gap voltage helps to reduce this unexpected heating.

43 PARTICLE ACCELERATORS↗

Characterization of Second Harmonic Afterburner Radiation at the LCLS

During commissioning of the Linac Coherent Light Source (LCLS) x-ray Free Electron Laser (FEL) at the SLAC National Accelerator Laboratory it was shown that saturation lengths much shorter than the installed length of the undulator line can routinely be achieved. This frees undulator segments that can be used to provide enhanced spectral properties and at the same time, test the concept of FEL Afterburners. In December 2009 a project was initiated to convert undulator segments at the down-beam end of the undulator line into Second Harmonic Afterburners (SHAB) to enhance LCLS radiation levels in the 10-20 keV energy range. This is being accomplished by replacement of gap-shims increasing the fixed gaps from 6.8 mm to 9.9 mm, which reduces their K values from 3.50 to 2.25 and makes the segments resonant at the second harmonic of the upstream unmodified undulators. This paper reports experimental results of the commissioning of the SHAB extension to LCLS.

43 PARTICLE ACCELERATORS↗

Echo-Enabled Harmonic Generation

A recently proposed concept of the Echo-Enabled Harmonic Generation (EEHG) FEL uses two laser modulators in combination with two dispersion sections to generate a high-harmonic density modulation in a relativistic beam. This seeding technique holds promise of a one-stage soft x-ray FEL that radiates not only transversely but also longitudinally coherent pulses. Currently, an experimental verification of the concept is being conducted at the SLAC National Accelerator Laboratory aimed at the demonstration of the EEHG.

43 PARTICLE ACCELERATORS↗

Noise Amplification in Echo-Enabled Harmonic Generation (EEHG)

Two essential elements of a seeded FEL based on the echo-enabled harmonic generation (EEHG) are the undulator-modulators, in which a laser beam modulates the beam energy. We study how the interaction of electrons in these undulators changes the noise properties of the beam. This paper is based on the method of noise analysis developed in Ref. [1] and extends it for the case of EEHG.