Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STRESS CORROSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The role of local strains from prior cold work on stress corrosion cracking of α-brass in Mattsson's solution

The dynamic strain rate ahead of a crack tip formed during stress corrosion cracking (SCC) under a static load is assumed to arise from the crack propagation. The strain surrounding the crack tip would be redistributed as the crack grows, thereby having the effect of dynamic strain. Recently, several studies have shown cold work to cause accelerated crack growth rates during SCC, and the slip-dissolution mechanism has been widely applied to account for this via a supposedly increased crack-tip strain rate in cold worked material. While these interpretations consider cold work as a homogeneous effect, dislocations are generated inhomogeneously within the microstructure during cold work. The presence of grain boundaries results in dislocation pile-ups that cause local strain concentrations. The local strains generated from cold working α-brass by tensile elongation were characterized using electron backscatter diffraction (EBSD). The role of these local strains in SCC was studied by measuring the strain distributions from the same regions of the sample before cold work, after cold work, and after SCC. Though, the cracks did not always initiate or propagate along boundaries with pre-existing local strains from the applied cold work, the local strains surrounding the cracked boundaries had contributions from both the crack propagation and the prior cold work. - Highlights: • Plastic strain localization has a complex relationship with SCC susceptibility. • Surface relief created by cold work creates its own granular strain localization. • Cold work promotes crack growth but several other factors are involved.

36 MATERIALS SCIENCE↗

Development of a numerical model for simulating stress corrosion cracking in spent nuclear fuel canisters

Abstract Prediction and detection of the chloride-induced stress corrosion cracking (CISCC) in Type 304 stainless steel spent nuclear fuel canisters are vital for the lifetime extension of dry storage canisters. This paper conducts a critical review that focuses on the numerical modeling and simulation on the research progress of the CISCC. The numerical models emphasizing the residual stress, susceptible microstructure, and corrosive environment are summarized individually. Meanwhile, the simulation studies on the role of hydrogen-assisted cracking are reviewed. Finally, a multi-physical numerical model, which combines the different fields is proposed based on our recent investigation.

Materials Science↗

STRESS CORROSION CRACK GROWTH RESPONSE FOR ALLOY 152/52 DISSIMILAR METAL WELDS IN PWR PRIMARY WATER

As part of ongoing research into primary water stress corrosion cracking (PWSCC) susceptibility of alloy 690 and its welds, SCC tests have been conducted on alloy 152/52 dissimilar metal (DM) welds with cracks positioned with the goal to assess weld dilution and fusion line effects on SCC susceptibility. No increased crack growth rate was found when evaluating a 20% Cr dilution zone in alloy 152M joined to carbon steel (CS) that had not undergone a post-weld heat treatment (PWHT). However, high SCC crack growth rates were observed when the crack reached the fusion line of that material where it propagated both on the fusion line and in the heat affected zone (HAZ) of the carbon steel. Crack surface and crack profile examinations of the specimen revealed that cracking in the weld region was transgranular (TG) with weld grain boundaries not aligned with the geometric crack growth plane of the specimen. The application of a typical pressure vessel PWHT on a second set of alloy 152/52 – carbon steel DM weld specimens was found to eliminate the high SCC susceptibility in the fusion line and carbon steel HAZ regions. PWSCC tests were also performed on alloy 152-304SS DM weld specimens. Constant K crack growth rates did not exceed 5x10-9 mm/s in this material with post-test examinations revealing cracking primarily on the fusion line and slightly into the 304SS HAZ.

alloy 152↗

Stress Corrosion cracking Testing in Supercritical Carbon Dioxide

This document presents a summary of the ldrd project. The project consists in developing testing capability to address stress corrosion cracking issues in supercritical carbon dioxide. In addition, this project is generating corrosion data. This work aims to help select structural materials for supercritical carbon dioxide energy systems.

36 MATERIALS SCIENCE↗

FY2022 Status Update: A Probabilistic Model for Stress Corrosion Cracking of SNF Dry Storage Canisters

Understanding the potential risk of stress corrosion cracking of spent nuclear fuel dry storage canisters has been identified as a knowledge gap for determining the safety of long-term interim storage of spent nuclear fuel. To address this, the DOE is funding a multi-lab DOE effort to understand the timing, occurrence, and consequences of potential canister SCC. Sandia National Laboratories has developed a probabilistic model for canister penetration by SCC. This model has been continuously updated at SNL since 2014. Model uncertainties are treated using a nested loop structure, where the outer loop accounts for uncertainties due to lack of data and the inner aleatoric loop accounts for uncertainties due to variation in nature. By separating uncertainties into these categories, it is possible to focus future work on reducing the most influential epistemic uncertainties. Several experimental studies have already been performed to improve the modeling approach through expanded process understanding and improved model parameterization. The resulting code is physics-based and intended to inform future work by identifying (1) important modeling assumptions, (2) experimental data needs, and (3) necessary model developments. In this document, several of the sub-models in the probabilistic SCC model have been exercised, and the intermediate results, as the model progresses from one sub-model to the next, are presented. Evaluating the sub-models in this manner provides a better understanding of sub-model outputs and has identified several unintended consequences of model assumptions or parameterizations, requiring updates to the modeling approach. The following updates have been made, and future updates have been identified.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Systems and methods for application of stress corrosion cracking resistant cold spray coatings

Systems and methods for application of stress corrosion cracking resistant cold spray coatings include a method of forming a partial coating on a canister having a perimeter wall with a surface. The method may include identifying a compromised region on the surface of the wall of the canister, and impacting a substantially linear flow of particles of a powder against an area in the compromised region of the surface in a manner effective to cause the particles of the powder to bond to the surface of the wall to produce a coating on the area of the compromised region. The method may also include moving the substantially linear flow in a direction substantially parallel to the surface of the wall to cause the particles to impact an additional area of the compromised region to cause the particles to bond to the surface of the additional area.

Johnson, Kyle William↗

Stress Corrosion Crack Initiation of Cold-Worked Alloy 600 and Alloy 690 in PWR Primary Water

This is an annual report summarizing research on stress corrosion crack initiation in alloy 600 and alloy 690 in simulated pressurized water reactor primary water environments. A key aspect of the work is developing an understanding of the mechanisms and controlling factors for producing initiated cracks in these materials. This work covers research that explores and compares the initiation response between alloy 600 and alloy 690.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

In situ investigation of high humidity stress corrosion cracking of 7075 aluminum alloy by three-dimensional (3D) X-ray synchrotron tomography

In situ X-ray synchrotron tomography was used to investigate the stress corrosion cracking behavior of under-aged Al–Zn–Mg–Cu alloy in moisture. The discontinuous surface cracks (crack jumps) mentioned in the literature are actually a single continuous and tortuous crack when observed in three dimension (3D). Contrary to 2D measurements made at the surface which suggest non-uniform crack growth rates, 3D measurements of the crack length led to a much more accurate measurement of crack growth rates.

36 MATERIALS SCIENCE↗

Effect of AC Current Density on the Stress Corrosion Cracking Behavior and Mechanism of E690 High-Strength Steel in Simulated Seawater

In this work, we studied the impact of alternating current (AC) density on the stress corrosion cracking (SCC) behavior and mechanism of E690 high-strength steel in simulated seawater with electrochemical measurements, U-bend immersion tests and slow strain rate tensile tests. Results demonstrate that AC enhances both anodic and cathodic processes, especially localized anodic dissolution and hydrogen evolution, which manifests as the increase in i{sub corr} with AC current density rising. Therefore, AC leads to higher SCC susceptibility. Accordingly, SCC is dominated by anodic dissolution (AD) at low AC current density while in a mixed control of AD and hydrogen embrittlement (HE) at high AC current density as a result of increasing hydrogen concentration. Besides, 50 A/m{sup 2} corresponds to the threshold hydrogen concentration of the “hydrogen-induced plasticity to HE” transformation, which is due to the different interactions of dislocation and hydrogen.

36 MATERIALS SCIENCE↗

Laser glazing of cold sprayed coatings for the mitigation of stress corrosion cracking in light water reactor (LWR) applications

The effect of laser power, traverse speed, and cold spray coating thickness were examined with the goal of mitigating and repairing stress corrosion cracking (SCC) in light water reactor (LWR) environment. For this purpose, SCC-susceptible Alloy 600 substrate material was coated with SCC-resistant Alloy 690 via the cold spray technique. The cold spray coated substrate was then laser-glazed using various laser parameters. Single pass and multiple pass laser glazed regions were created to determine the effects. For this purpose, the area of the fusion zone, depth of the fusion zone, and elemental composition of the cross section were examined by optical microscopy, scanning electron microscopy, and energy dispersive spectroscopy. Additionally, it was shown that chromium dilution from the laser glazed region into the substrate is not a significant factor in laser glazed cold spray coated samples. Separate laser glazed samples were subjected to ASTM 633C to determine coating adhesion. Finally, by using interrupted SCC crack growth rate tests, it was shown that low traverse speeds and high laser powers produce deep fusion zones within the cold sprayed coating and substrate that can be used to seal pre-existing cracks, thus stopping SCC growth.

36 MATERIALS SCIENCE↗

Stress corrosion cracking of several solution heat-treated Mg–X alloys

Here we studied the stress corrosion cracking (SCC) behaviour of solution heat-treated as-cast Mg0.1Zr, Mg1Mn, Mg0.1Sr, Mg0.3Si, Mg5Sn, Mg5Zn and Mg0.3Ca in distilled water (DW) using the linearly increasing stress test (LIST). SCC susceptibility was related to the stress rate for all the Mg–X alloys except for Mg0.1Sr. At ~7.0 × 10 ₋4 MPa s ₋1 , Mg0.3Si and Mg5Sn were immune to SCC; Mg0.1Zr, Mg1Mn and Mg0.1Sr suffered medium SCC; Mg5Zn and Mg0.3Ca suffered relatively more serious SCC. At ~7.0 × 10 ₋5 MPa s ₋1 , Mg5Zn and Mg0.3Ca suffered the most serious transgranular SCC, whilst the other Mg–X alloys suffered medium SCC.

36 MATERIALS SCIENCE↗

Understanding the Risk of Chloride Induced Stress Corrosion Cracking of Interim Storage Containers for the Dry Storage of Spent Nuclear Fuel: Evolution of Brine Chemistry on the Container Surface.

Although the susceptibility of austenitic stainless steels to chloride-induced stress corrosion cracking is well known, uncertainties exist in terms of the environmental conditions that exist on the surface of the storage containers. While a diversity of salts is present in atmospheric aerosols, many of these are not stable when placed onto a heated surface. Given that the surface temperature of any container storing spent nuclear fuel will be well above ambient, it is likely that salts deposited on its surface may decompose or degas. To characterize this effect, relevant single and multi-salt mixtures are being evaluated as a function of temperature and relative humidity to establish the rates of degassing, as well as the likely final salt and brine chemistries that will remain on the canister surface.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Stress Corrosion Cracking of Ferritic Materials for Fossil Power Generation Applications

Creep strength enhanced ferritic (CSEF) steels Grades 23, 24, 91, and 92 have been widely implemented in the fossil fired industry for over two decades. The stress corrosion cracking (SCC) behavior of these materials with respect to mainstay Cr-Mo steels (such as Grades 11, 12 and 22) has not been properly assessed, particularly in consideration of recent reported issues of SCC in CSEF steels. This report details the results of Jones test exposures of a wide range of materials (Grades 11, 22, 23, 24, and 92), material conditions (as-received, improper heat treatments, normalized, weldments) and environments (salt fog; tube cleaning environments including decreasing, scale removal, and passivation; and high temperature water) to compare the susceptibility to cracking of these steels. In the as-received (normalized and tempered) condition, none of these materials are susceptible to SCC in the environments examined. However, in the hardened condition, certain combinations of environment and alloy reveal substantial SCC susceptibility.

ferritic↗

Historical Review of Stress Corrosion Cracking in Concentrated Uranium-Molybdenum Alloys

This report presents a historical overview of stress corrosion cracking (SCC) in uranium-molybdenum alloys, focusing primarily on bare U-10 wt. pct. Mo (U-10Mo). The fuel system being pursued by the United States High Performance Research Reactor (USHPRR) project incorporates a zirconium interlayer applied early in the process which likely serves as a protective coating. This alloy has been chosen as the high density uranium monolithic fuel for converting research reactors from high enriched uranium (HEU) to low enriched uranium (LEU) fuel for its combination of fuel density and gamma phase stability.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Intergranular Stress Corrosion Crack Initiation and Temperature Dependence of Alloy 600 in Pressurized Water Reactor Primary Water

Stress corrosion crack (SCC) initiation of a solution annealed, cold-worked (CW) UNS N06600 (Alloy 600) material was investigated in 360 and 325ºC simulated PWR primary water using constant load tensile instrumented for in-situ detection by the direct current potential drop technique. This CW material with high boron and low carbon bulk concentrations was found to be highly susceptible to SCC. Consistent SCC initiation times were obtained at both temperatures and the thermal activation energy for SCC initiation is estimated at ~116 kJ/mol.

Zhai, Ziqing↗

Crystallographic effects on transgranular chloride-induced stress corrosion crack propagation of arc welded austenitic stainless steel

Abstract The effect of crystallography on transgranular chloride-induced stress corrosion cracking (TGCISCC) of arc welded 304L austenitic stainless steel is studied on >300 grains along crack paths. Schmid and Taylor factor mismatches across grain boundaries (GBs) reveal that cracks propagate either from a hard to soft grain, which can be explained merely by mechanical arguments, or soft to hard grain. In the latter case, finite element analysis reveals that TGCISCC will arrest at GBs without sufficient mechanical stress, favorable crystallographic orientations, or crack tip corrosion. GB type does not play a significant role in determining TGCISCC cracking behavior nor susceptibility. TGCISCC crack behaviors at GBs are discussed in the context of the competition between mechanical, crystallographic, and corrosion factors.

36 MATERIALS SCIENCE↗

Preliminary Modeling of Chloride Deposition on Spent Nuclear Fuel Canisters in Dry Storage Relevant to Stress Corrosion Cracking

This study presents a method that can be used to gain information relevant to determining the corrosion risk for spent nuclear fuel (SNF) canisters during extended dry storage. Currently, it is known that stainless steel canisters are susceptible to chloride-induced stress corrosion cracking (CISCC). However, the rate of CISCC degradation and the likelihood that it could lead to a through-wall crack is unknown. This study uses well-developed computational fluid dynamics and particle-tracking tools and applies them to SNF storage to determine the rate of deposition on canisters. The deposition rate is determined for a vertical canister system and a horizontal canister system, at various decay heat rates with a uniform particle size distribution, ranging from 0.25 to 25 µm, used as an input. In all cases, most of the dust entering the overpack passed through without depositing. Most of what was retained in the overpack was deposited on overpack surfaces (e.g., inlet and outlet vents); only a small fraction was deposited on the canister itself. These results are provided for generalized canister systems with a generalized input; as such, this paper is intended to demonstrate the technique. This study is a part of an ongoing effort funded by the U.S. Department of Energy, Nuclear Energy Office of Spent Fuel Waste Science and Technology, which is tasked with doing research relevant to developing a sound technical basis for ensuring the safe extended storage and subsequent transport of SNF. This work is being presented to demonstrate a potentially useful technique for SNF canister vendors, utilities, regulators, and stakeholders to utilize and further develop for their own designs and site-specific studies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

US NRC-Sponsored Research on Stress Corrosion Cracking Susceptibility of Dry Storage Canister Materials in Marine Environments - 13344

At a number of locations in the U.S., spent nuclear fuel (SNF) is maintained at independent spent fuel storage installations (ISFSIs). These ISFSIs, which include operating and decommissioned reactor sites, Department of Energy facilities in Idaho, and others, are licensed by the U.S. Nuclear Regulatory Commission (NRC) under Title 10 of the Code of Federal Regulations, Part 72. The SNF is stored in dry cask storage systems, which most commonly consist of a welded austenitic stainless steel canister within a larger concrete vault or overpack vented to the external atmosphere to allow airflow for cooling. Some ISFSIs are located in marine environments where there may be high concentrations of airborne chloride salts. If salts were to deposit on the canisters via the external vents, a chloride-rich brine could form by deliquescence. Austenitic stainless steels are susceptible to chloride-induced stress corrosion cracking (SCC), particularly in the presence of residual tensile stresses from welding or other fabrication processes. SCC could allow helium to leak out of a canister if the wall is breached or otherwise compromise its structural integrity. There is currently limited understanding of the conditions that will affect the SCC susceptibility of austenitic stainless steel exposed to marine salts. NRC previously conducted a scoping study of this phenomenon, reported in NUREG/CR-7030 in 2010. Given apparent conservatisms and limitations in this study, NRC has sponsored a follow-on research program to more systematically investigate various factors that may affect SCC including temperature, humidity, salt concentration, and stress level. The activities within this research program include: (1) measurement of relative humidity (RH) for deliquescence of sea salt, (2) SCC testing within the range of natural absolute humidity, (3) SCC testing at elevated temperatures, (4) SCC testing at high humidity conditions, and (5) SCC testing with various applied stresses. Results to date indicate that the deliquescence RH for sea salt is close to that of MgCl{sub 2} pure salt. SCC is observed between 35 and 80 deg. C when the ambient (RH) is close to or higher than this level, even for a low surface salt concentration. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗