Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STAGNATION PRESSURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Two-phase choked flow of subcooled nitrogen through a slit

Two-phase choked flow rate and pressure distribution data are reported for subcooled nitrogen flowing through a slit. The slit was a narrow rectangular passage of equal length and width. The inlet stagnation pressure ranged from slightly above saturation to twice the thermodynamic critical pressure. Four stagnation isotherms were investigated, covering a range which spanned the critical temperature. The results suggested a uniform two-phase flow pattern with vaporization occurring at or near the exit in most cases. The results compared favorably with the theory of Henry (1970) for nonequilibrium subcooled two-phase choked flow in long tubes.

Simoneau, R. J.↗

Some flow phenomena in a constant area duct with a Borda type inlet including the critical region

Mass limiting flow characteristics for a 55 L/D tube with a Borda type inlet were assessed over large ranges of temperature and pressure, using fluid nitrogen. Under certain conditions, separation and pressure drop at the inlet was sufficiently strong to permit partial vaporization and the remaining fluid flowed through the tube as if it were a free jet. An empirical relation was determined which defines conditions under which this type of flow can occur. A flow coefficient is presented which enables estimations of flow rates over the experimental range. A flow rate stagnation pressure map for selected stagnation isotherms and pressure profiles document these flow phenomena.

Hendricks, R. C.↗

Some flow phenomena in a constant area duct with a Borda type inlet including the critical region

Mass limiting flow characteristics for a 55 L/D tube with a Borda type inlet have been assessed over large ranges of temperature and pressure using fluid nitrogen. Under certain conditions, separation and pressure drop at the inlet was sufficiently strong to permit partial vaporization and the remaining fluid flowed through the tube as if it were a free jet. An empirical relation was determined which defines conditions under which this type of flow can occur. A flow coefficient is presented which enables one to estimate flow rates over the experimental range. A flow rate stagnation pressure map for selected stagnation isotherms and pressure profiles document these flow phenomena.

Hendricks, R. C.↗

Experimental study of forward-located jet-interaction nozzles

The effects of forward-mounted sonic jet-interaction nozzles with one, three equal, or one large and two small orifices on the transitional or turbulent boundary-layer flow over a biconic (9-deg-25-arcmin/6-deg) model at angle of attack -10 to the 15 deg and Reynolds number 8.10 x 10 to the 6th/ft are investigated experimentally using pressure taps, force measurements, oil-flow visualization, and schlieren photography in the 20-in. Mach-6 wind tunel at NASA Langley. The injection flow rates are 0.055 and 0.026 lbm/s, with stagnation pressure 500 psia, stagnation temperature 1000 R, and dynamic pressure 8.7 psia. The results are presented in diagrams, graphs, and photographs and characterized. Moment amplification factors of 1.0 or better (maximum 1.8 at angle of attack 15 deg and flow rate 0.055 lbm/s) are observed for all nozzle types, but the configuration with three unequal orifices is found to give improvements of 10 percent over the single-orifice nozzle at a given flow rate.

Cavalleri, R. J.↗

Jet penetration into a liquid

Stagnation pressure and displaced liquid analysis of gas jet impingement on and penetration into liquid at subsonic and supersonic speeds

IMPINGEMENT↗

Real-air data reduction procedures based on flow parameters measured in the test section of supersonic and hypersonic facilities

Data-reduction procedures for determining free stream and post-normal shock kinetic and thermodynamic quantities are derived. These procedures are applicable to imperfect real air flows in thermochemical equilibrium for temperatures to 15 000 K and a range of pressures from 0.25 N/sq m to 1 GN/sq m. Although derived primarily to meet the immediate needs of the 6-inch expansion tube, these procedures are applicable to any supersonic or hypersonic test facility where combinations of three of the following flow parameters are measured in the test section: (1) Stagnation pressure behind normal shock; (2) freestream static pressure; (3) stagnation point heat transfer rate; (4) free stream velocity; (5) stagnation density behind normal shock; and (6) free stream density. Limitations of the nine procedures and uncertainties in calculated flow quantities corresponding to uncertainties in measured input data are discussed. A listing of the computer program is presented, along with a description of the inputs required and a sample of the data printout.

Miller, C. G., III↗

Expanding the Measurement Capabilities of the mARC II Arc-Jet to Map the Operating Envelope for High-Enthalpy Air Flows

The mARC II is a 30 kW arc-jet facility at NASA Ames Research Center developed to produce high-enthalpy flows for low-cost technology development purposes. In this work, we introduce new measurement capabilities following the latest facility upgrades and begin characterizing the operating envelope for the two-disk arc-heater configuration with air as the working gas. The lower bound of the envelope corresponds to the lowest set current and the farthest sensor distance from the nozzle (𝐼set = 40 A, 𝑧 = 69 mm), while the upper bound corresponds to the highest current and closest sensor distance (𝐼set = 200 A, 𝑧 = 2 mm). Stagnation point heat flux was measured using a water-cooled Gardon gauge (⌀4.76 mm, 3/16" hemispherical), with values ranging from 15 ≤ q̇₀ ≤ 900 W/cm2. Stagnation pressure was measured using a water-cooled Pitot probe (⌀4.76 mm, 3/16" hemispherical), with values ranging from 18 ≤ p₀ ≤ 1100 Pa. The upgraded vacuum system is demonstrated to significantly extend the lower end of the operating envelope of the mARC II. Additionally, measurements of bulk enthalpy (3 ≤ h ≤ 13 MJ/kg) and stagnation enthalpy (4 ≤ h₀ ≤ 34 MJ/kg) demonstrate the mARC II facility's high-enthalpy capabilities. Completion of the operating envelope characterization is ongoing in tandem with the development of complementary diagnostic capabilities and numerical simulations.

TPS↗

Expanding the Measurement Capabilities of the mARC II Arc-Jet to Map the Operating Envelope for High-Enthalpy Air Flows

The mARC II is a 30 kW arc-jet facility at NASA Ames Research Center developed to produce high-enthalpy flows for low-cost technology development purposes. In this work, we introduce new measurement capabilities following the latest facility upgrades and begin characterizing the operating envelope for the two-disk arc-heater configuration with air as the working gas. The lower bound of the envelope corresponds to the lowest set current and the farthest sensor distance from the nozzle (𝐼set = 40 A, 𝑧 = 69 mm), while the upper bound corresponds to the highest current and closest sensor distance (𝐼set = 200 A, 𝑧 = 2 mm). Stagnation point heat flux was measured using a water-cooled Gardon gauge (⌀4.76 mm, 3/16" hemispherical), with values ranging from 15 ≤ q̇₀ ≤ 900 W/cm 2 . Stagnation pressure was measured using a water-cooled Pitot probe (⌀4.76 mm, 3/16" hemispherical), with values ranging from 18 ≤ p₀ ≤ 1100 Pa. The upgraded vacuum system is demonstrated to significantly extend the lower end of the operating envelope of the mARC II. Additionally, measurements of bulk enthalpy (3 ≤ h ≤ 13 MJ/kg) and stagnation enthalpy (4 ≤ h₀ ≤ 34 MJ/kg) demonstrate the mARC II facility's high-enthalpy capabilities. Completion of the operating envelope characterization is ongoing in tandem with the development of complementary diagnostic capabilities and numerical simulations.

instrumentation↗

The U.S. 2.5-Meter Cryogenic High Reynolds Number Tunnel

The U.S. 2.5-Meter Cryogenic High Reynolds Number Tunnel is a fan-driven transonic wind tunnel scheduled for operation in 1981. It will operate at Mach numbers from 0.1 to 1.2, stagnation pressures from 1 to 9 bars, and stagnation temperatures from 352 to 80 Kelvin. The maximum Reynolds number capability will be 120 million at a Mach number of 1.0 based on a reference length of 0.25 meter. This paper describes the basis for the conceptual approach, the engineering design including unique features, and the performance operating envelopes for the tunnel.

Howell, R. R.↗

Shape change of Galileo probe models in free-flight tests

Scale models of the Galileo Probe made of polycarbonate, AXF5Q graphite, carbon-carbon composite, and carbon-phenolic were flown in a free flight range in an ambient gas of air, krypton, or xenon. Mach numbers varied between 14 and 24, Reynolds numbers between 300,000 and 1,000,000, stagnation pressures between 31 and 200 atm, and stagnation point heat transfer rates between 10 and 1,000 kW/sq cm. Shadowgraphs indicate gouging ablation of the aft portion of the frustum; the gouging was moderate in air and severe in the noble gases. The graphite models break in the same region. An explanation of the phenomena is offered in terms of the strong compression and shear caused by the reattachment of a turbulent separated flow. Conditions are calculated for similar tests appropriate for Von Karman Facility of the Arnold Engineering Development Center in which a larger model can be flown in argon.

Park, C.↗

Transient response characteristics of test chamber Mach number

The transient dynamic characteristics of a test chamber Mach number was established for a disturbance initiated in the test chamber. An approximate linear expression was given, showing that the change in the Mach number is linearly proportional to the algebraic sum of the static pressure change in the test chamber and the stagnation pressure change. The static pressure change is the dominating factor. The two pressure changes were also calculated for small Mach number variations, and these results were applied to instrumentation requirements.

Tcheng, P.↗

Statics and dynamics of Giacobini-Zinner magnetic tail

The data gathered by the International Cometary Explorer during its traversal of Comet Giacobini-Zinner's tail are subjected to stress balance requirements, yielding estimates of unmeasured quantities. It is noted that the comet's tail is embedded in an ionosheath whose static pressure is nearly equal to the solar wind stagnation pressure, leading to a large lobe field strength. A systematic variation is found in the ion temperature across the tail, implying the variation of the pickup velocity of new ions. Axial stress balance yields an expression for the strength of the lobe field which reveals weak variation with axial distance.

Siscoe, G. L.↗

Basic Pressure Measurements at Transonic Speeds on a Thin 45 deg Sweptback Highly Tapered Wing with Systematic Spanwise Twist Variations

Pressure distributions are presented for a thin highly tapered untwisted 45 deg sweptback wing in combination with a body. These tests were made in the Langley 8-foot transonic pressure tunnel at both 1.0 and 0.5 atmosphere stagnation pressures at Mach numbers from 0.800 to 1.200 through an angle-of-attack range of -4 deg to 12 deg.

Mugler, John P., Jr.↗

CFD Simulations of the AEDC H3 Arc-Jet Flow: Mach 3.3 Nozzle, Flow Surveys, Wedge Models

This paper reports computational simulations and analysis of tests in a high enthalpy arc-jet facility at Arnold Engineering Development Center. These tests were conducted using wedge models placed in a free jet downstream of a 4.5-inch diameter contoured Mach 3.3 nozzle in the H3 facility. For calibration of test conditions, one wedge calibration plate instrumented with an array of pressure and coaxial thermocouple heat flux gages, one stagnation pressure probe and two null-point heat flux calorimeters were used. The pitot pressure and null-point probe measurements give experimental surveys of the test flow, providing assessment of the flow uniformity and valuable data for flow characterization. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle, into the test box and over the wedge models, and comparisons with the experimental measurements. Several issues related to testing are considered: test flow characterization, prediction of surface quantities for three wedge models, effects of model shape change and test article recession, and prediction of surface quantities for the test articles with two circular cavities. These simulations take into account non-uniform total enthalpy profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the wedge model flowfields.

Arc-jet testing↗

Maximum two-phase flow rates of subcooled nitrogen through a sharp-edged orifice

Data are presented of an experiment in which subcooled liquid nitrogen was discharged through a sharp-edged orifice at flow rates near the maximum. The data covered a range of inlet stagnation pressures from slightly above saturation to twice the thermodynamic critical pressure. The data were taken along five separate inlet stagnation isotherms ranging from 0.75 to 1.035 times the thermodynamic critical temperature. The results indicate that subcooled liquids do not choke or approach maximum flow in an asymptotic manner even though the back pressure is well below saturation; and orifice flow coefficients are not constant as is frequently assumed. A metastable jet appears to exist which breaks down if the difference between back pressure and saturation pressure is large enough.

Simoneau, R. J.↗

Maximum two-phase flow rates of subcooled nitrogen through a sharp-edged orifice

An experiment was conducted and data are presented in which subcooled liquid nitrogen was discharged through a sharp-edged orifice at flow rates near the maximum. The data covered a range of inlet stagnation pressure from slightly above saturation to twice the thermodynamic critical pressure. The data were taken along five separate inlet stagnation isotherms ranging from 0.75 to 1.035 times the thermodynamic critical temperature. The results indicate that: (1) subcooled liquids do not choke or approach maximum flow in an asymptotic manner even though the back pressure is well below saturation; (2) orifice flow coefficients are not constant as is frequently assumed. A metastable jet appears to exist which breaks down if the difference between back pressure and saturation pressure is large enough.

Simoneau, R. J.↗

The Scaling of Broadband Shock-Associated Noise with Increasing Temperature

A physical explanation for the saturation of broadband shock-associated noise (BBSAN) intensity with increasing jet stagnation temperature has eluded investigators. An explanation is proposed for this phenomenon with the use of an acoustic analogy. To isolate the relevant physics, the scaling of BBSAN peak intensity level at the sideline observer location is examined. The equivalent source within the framework of an acoustic analogy for BBSAN is based on local field quantities at shock wave shear layer interactions. The equivalent source combined with accurate calculations of the propagation of sound through the jet shear layer, using an adjoint vector Green's function solver of the linearized Euler equations, allows for predictions that retain the scaling with respect to stagnation pressure and allows for saturation of BBSAN with increasing stagnation temperature. The sources and vector Green's function have arguments involving the steady Reynolds- Averaged Navier-Stokes solution of the jet. It is proposed that saturation of BBSAN with increasing jet temperature occurs due to a balance between the amplication of the sound propagation through the shear layer and the source term scaling.

Miller, Steven A. E.↗

Absorption Laser Differential Interferometry for Simultaneous Colinear Flow Property and Fluctuation Measurements

An absorption laser differential interferometer (A-LDI) was constructed and tested in an effort to simultaneously and colinearly measure flow properties (pressure, temperature, concentration) and flow fluctuations (changes in optical path length). Whereas typical LDI and focused LDI (FLDI) systems use fixed wavelength lasers as the light source (often either green at approximately 532 nm or red at approximately 630 nm), a tunable 760 nm diode laser was used to probe the A-band absorption spectrum of molecular oxygen. The A-LDI system was used to measure O2 absorption and flow fluctuations in a sub-atmospheric pressure-controlled test cell, with absorption profiles from direct absorption and wavelength modulation absorption matching simulated results, while simultaneously being sensitive to high frequency fluctuations from jets of either compressed air or 100% O2 from a gas bottle. The A-LDI system was also installed at the NASA Langley Research Center Probe Calibration Tunnel to assess the freestream flow state in a Mach 3.5 flow. LDI measurements of the freestream indicated increasing amplitudes of flow fluctuations with increasing stagnation pressure at a fixed stagnation temperature, while absorption results demonstrated sensitivity to freestream pressure changes.

Joshua M. Weisberger↗