Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STACKS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Development and characterization of a three-dimensional radiochromic film stack dosimeter for megavoltage photon beam dosimetry

Purpose: Three-dimensional (3D) dosimeters are particularly useful for verifying the commissioning of treatment planning and delivery systems, especially with the ever-increasing implementation of complex and conformal radiotherapy techniques such as volumetric modulated arc therapy. However, currently available 3D dosimeters require extensive experience to prepare and analyze, and are subject to large measurement uncertainties. This work aims to provide a more readily implementable 3D dosimeter with the development and characterization of a radiochromic film stack dosimeter for megavoltage photon beam dosimetry. Methods: A film stack dosimeter was developed using Gafchromic{sup ®} EBT2 films. The dosimeter consists of 22 films separated by 1 mm-thick spacers. A Virtual Water™ phantom was created that maintains the radial film alignment within a maximum uncertainty of 0.3 mm. The film stack dosimeter was characterized using simulations and measurements of 6 MV fields. The absorbed-dose energy dependence and orientation dependence of the film stack dosimeter were investigated using Monte Carlo simulations. The water equivalence of the dosimeter was determined by comparing percentage-depth-dose (PDD) profiles measured with the film stack dosimeter and simulated using Monte Carlo methods. Film stack dosimeter measurements were verified with thermoluminescent dosimeter (TLD) microcube measurements. The film stack dosimeter was also used to verify the delivery of an intensity-modulated radiation therapy (IMRT) procedure. Results: The absorbed-dose energy response of EBT2 film differs less than 1.5% between the calibration and film stack dosimeter geometries for a 6 MV spectrum. Over a series of beam angles ranging from normal incidence to parallel incidence, the overall variation in the response of the film stack dosimeter is within a range of 2.5%. Relative to the response to a normally incident beam, the film stack dosimeter exhibits a 1% under-response when the beam axis is parallel to the film planes. Measured and simulated PDD profiles agree within a root-mean-square difference of 1.3%. In-field film stack dosimeter and TLD measurements agree within 5%, and measurements in the field penumbra agree within 0.5 mm. Film stack dosimeter and TLD measurements have expanded (k = 2) overall measurement uncertainties of 6.2% and 5.8%, respectively. Film stack dosimeter measurements of an IMRT dose distribution have 98% agreement with the treatment planning system dose calculation, using gamma criteria of 3% and 2 mm. Conclusions: The film stack dosimeter is capable of high-resolution, low-uncertainty 3D dose measurements, and can be readily incorporated into an existing film dosimetry program.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Slip-stacking Dynamics for High-Power Proton Beams at Fermilab

Slip-stacking is a particle accelerator configuration used to store two particle beams with different momenta in the same ring. The two beams are longitudinally focused by two radiofrequency (RF) cavities with a small frequency difference between them. Each beam is synchronized to one RF cavity and perturbed by the other RF cavity. Fermilab uses slip-stacking in the Recycler so as to double the power of the 120 GeV proton beam in the Main Injector. This dissertation investigates the dynamics of slip-stacking beams analytically, numerically and experimentally. In the analytic analysis, I find the general trajectory of stable slip-stacking particles and identify the slip-stacking parametric resonances. In the numerical analysis, I characterize the stable phase-space area and model the particle losses. In particular, I evaluate the impact of upgrading the Fermilab Booster cycle-rate from 15 Hz to 20 Hz as part of the Proton Improvement Plan II (PIP-II). The experimental analysis is used to verify my approach to simulating slip-stacking loss. I design a study for measuring losses from the longitudinal single-particle dynamics of slip-stacking as a function of RF cavity voltage and RF frequency separation. I further propose the installation of a harmonic RF cavity and study the dynamics of this novel slip-stacking configuration. I show the harmonic RF cavity cancels out parametric resonances in slip-stacking, reduces emittance growth during slip-stacking, and dramatically enhances the stable phase-space area. The harmonic cavity is expected to reduce slip-stacking losses to far exceed PIP-II requirements. These results raise the possibility of extending slip-stacking beyond the PIP-II era.

43 PARTICLE ACCELERATORS↗

Method and apparatus for thermal, mechanical, and electrical optimization of a solid-oxide fuel cell stack

A solid-oxide fuel cell stack assembly comprising a plurality of sub-stacks, preferably two sub-stacks each containing one-half the total number of fuel cells. Cathode air and fuel gas are passed through the first sub-stack, wherein they are partially reacted and also heated. The exhaust cathode air and the exhaust fuel gas from the first sub-stack are directed to the respective inlets of the second sub-stack, becoming the supply cathode air and fuel gas therefor. A first heat exchanger in the flow paths between the sub-stacks and a second heat exchanger ahead of the sub-stacks can help to balance the performance of the two stacks. The result of dividing the number of cells into a plurality of sub-stacks, wherein the exhaust of one sub-stack becomes the supply for the next sub-stack, is that fuel efficiency and utilization are improved, thermal stresses are reduced, and electrical power generation is increased.

30 DIRECT ENERGY CONVERSION↗

Solid Oxide Based Electrolysis and Stack Technology with Ultra-High Electrolysis Current Density (>3A/cm 2 ) and Efficiency

Hydrogen, a valuable commodity gas, is increasingly recognized as an important fuel and energy storage pathway of the future. This project aims to develop an innovative solid oxide based electrolysis cell and stack technology with ultra-high steam electrolysis current (>3A/cm 2 ) for potentially ultra-low-cost, highly efficient hydrogen production from diverse renewable sources. In this project, solid oxide based high power density cells (HiPoD cells) were developed. Those cells demonstrated capability of operating at ultra-high electrolysis current density of 6 A/cm 2 at 1.67V. During a long term steady state electrolysis test, a HiPoD cell was operated for more than 1000 hours at 3 A/cm 2 with a low degradation rate of 1.8% per 1000 hours. A 20-cell electrolysis stack was built using HiPoD cells and an ultra-compact, low-cost stack design platform. This stack was used to explore the boundaries of high current density electrolysis operation and achieved an incredible stack current density of 3 A/cm 2 with an average cell voltage of only 1.493 V. The stack was further operated in steady-state electrolysis at 2 A/cm 2 for more than 1000 hours with an overall degradation of 0.57% per 1000 hours. With an improved understanding of electrolysis operation at ultra-high current density, a new compact stack architecture (CSA) design with scalability up to 55 kW (or 38 kg H 2 per day) was tested. A number of 45-cell CSA stack was built and demonstrated 10 kW and 245 g/hr hydrogen production at 1.8 A/cm 2 electrolysis current density. In addition to cell and stack development, a preliminary system design was developed by integrating the inputs from electrochemistry, cell/stack performance data, and system level implications of configuration and operational parameters. A module design was created based on a circular array of six stacks surrounded in a cool pressure vessel. Further architectural and controls strategies such as stack power control and instrumentation were determined through the development of the module. A comprehensive techno-economic study of an ultra-high current density SOEC system integrated with renewable energy sources has been conducted. To determine the estimated cost of hydrogen for the system, the H2A Current Distributed Hydrogen Production Model version 3.101 was applied. Annual system production cases at both commercial and industrial electricity rates as per the H2A model was analyzed. The option of meeting DOE 2020 Advanced Electrolysis Technologies targets were discussed. Feedstock electricity represents the bulk of projected hydrogen cost with either electricity rate. At an annual production volume of 250 units, H2A hydrogen cost of $2.3/kg can be achieved at electricity cost around 3.5¢/kWh.

08 HYDROGEN↗

Computational Fluid Dynamics Modeling to Facilitate Qualification of Stack Sampling Probe Location

Computational fluid dynamics (CFD) modeling was used to help evaluate modifications to a radiological effluent stack and assist with establishing a stack sampling location that met the mixing criteria for qualification. Requirements for stack sampling location are listed in the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-2021 standard. Modeling was performed to help develop a suitable design for increasing building ventilation for the radiological effluent stack. The ANSI/HPS N13.1-2021 criteria for the air monitoring probe location are that the coefficient of variation of velocity uniformity, gaseous tracer uniformity, and particulate tracer uniformity must be less than or equal to 20%. Furthermore, no point in the sampling location may have a gaseous tracer concentration that varies from the mean concentration by more than 30%. Additionally, the flow angle at the sampling location must not be more than 20 degrees. The ANSI/HPS N13.1-2021 standard allows for models (physical or computational) to be employed to perform the full suite of qualification tests, followed by a more limited set of verification tests on the actual stack to qualify the stack sampling location. Here, a series of computational model simulations were employed to evaluate the stack qualification criteria. Significant time and re-source savings are achieved using CFD modeling. CFD modeling demonstrated that the stack meets the criteria at the sample probe location. Verification tests were performed on the modified stack to measure the velocity uniformity and flow angle at the stack sampling location, and results demonstrated that the CFD model results may be used to support the qualification of the stack sampling location.

Air Monitoring↗

Performance characterization of metal-supported solid-oxide fuel cell stacks at elevated pressure

Here, in this paper, we present results on performance characterization of solid oxide fuel cell stacks at elevated pressures up to 6 bar a . Stacks are designed and built by Ceres Power, Ltd., and are rated at 1- and 5- kW e . Fuel streams include H 2 / N 2 mixtures, synthetic natural-gas reformate, and simulated anode tail-gas recycle. Elevated operating pressure serves to increase stack electrochemical performance, with the most-pronounced gains found up to 4 bar a . Pressurized operation reduces the extent of methane conversion, promoting more-uniform internal reforming and cooling within the stack. Such cooling is critical at higher-current conditions. A previously developed one dimensional computational stack model is used to provide insight into stack operation. Pressurization is found to slightly increase internal thermal gradients, while promoting more-uniform reactant-concentration profiles across the cell, reducing the likelihood of local fuel starvation. The high fuel dilution brought by anode recycle can modestly decrease stack performance; however, this decrease is recovered through elevated-pressure operation at 3 bar a . Anode recycle further promotes compositional uniformity across the cell. These results reflect that pressurized operation can promote stack performance, while potentially promoting long-term stack durability through uniformity in stack environmental conditions.

25 ENERGY STORAGE↗

Modeling the Air Flow in the 3410 Building Filtered Exhaust Stack System

Additional ventilation capacity has been designed for the 3410 Building filtered exhaust stack system. The updated system will increase the number of fans from two to three and will include ductwork to incorporate the new fan into the existing stack. Stack operations will involve running various two-fan combinations at any given time. The air monitoring system of the existing two-fan stack was previously found to be in compliance with the ANSI/HPS N13.1-1999 standard, however it is not known if the modified (three-fan) system will comply. Subsequently, a full-scale three-dimensional (3-D) computational fluid dynamics (CFD) model of the modified stack system has been created to examine the sampling location for compliance with the standard. The CFD modeling results show good agreement with testing data collected from the existing 3410 Building stack and suggest that velocity uniformity and flow angles will remain well within acceptance criteria when the third fan and associated ductwork is installed. This includes two-fan flow rates up to 31,840 cfm for any of the two-fan combinations. For simulation cases in which tracer gas and particles are introduced in the main duct, the model predicts that both particle and tracer gas coefficients of variance (COVs) may be larger than the acceptable 20 percent criterion of the ANSI/HPS N13.1-1999 standard for each of the two-fan, 31,840 cfm combinations. Simulations in which the tracers are introduced near the fans result in improved, though marginally acceptable, COV values for the tracers. Due to the remaining uncertainty that the stack will qualify with the addition of the third fan and high flow rates, a stationary air blender from Blender Products, Inc. is considered for inclusion in the stack system. A model of the air blender has been developed and incorporated into the CFD model. Simulation results from the CFD model that includes the air blender show striking improvements in tracer gas mixing and tracer particle dispersion. The results of these simulations suggest the air blender should be included in the stack system to ensure qualification of the stack.

3410 Building↗

Innovative, Versatile and Cost-Effective Solid Oxide Fuel Cell Stack Concept

This report summarizes the work performed for the U. S. Department of Energy/National Energy Technology Laboratory (DOE/NETL) under Cooperative Agreement DE-FE0026211 entitled “Innovative, Versatile and Cost-Effective Solid Oxide Fuel Cell Stack Concept”. The overall objective of this project was to develop and evaluate a solid oxide fuel cell (SOFC) stack configuration based on a novel prime-surface interconnect design for a broad range of power generation applications. The prime-surface is a one-piece metallic interconnect that incorporates both fuel and oxidant flow fields with peaks on one side of the interconnect serving as flow channels (valleys) on the other side. (One example is the egg-carton shaped interconnect design.) This stack technology has several attractive features including reduced stack weight and volume, decreased performance losses in stacking, improved sealing, versatility in incorporation of different types of cell construction (thin-film cells or sintered cells) and flexibility in gas flow configuration (cross-flow, co-flow or counter-flow). These features lead to lower cost, better performance, and enhanced reliability for the stack. The R&D work of this project focused on demonstrating fabrication, operability and cost effectiveness of the stack design and was conducted by University of California, San Diego (UCSD) in conjunction with OxEon Energy (OxEon). The key technical activities of this project involved prime-surface interconnect design and fabrication development; supported thin-film cell structure development; stack development; stack operation demonstration; and stack cost assessment. The results of these activities are summarized in this report.

30 DIRECT ENERGY CONVERSION↗

Substituent and Heteroatom Effects on π–π Interactions: Evidence That Parallel-Displaced π-Stacking is Not Driven by Quadrupolar Electrostatics

Stacking interactions are a recurring motif in supramolecular chemistry and biochemistry, where a persistent theme is a preference for parallel-displaced aromatic rings rather than face-to-face π-stacking. This is usually explained in terms of quadrupole–quadrupole interactions between the arene moieties but that interpretation is inconsistent with accurate calculations, which reveal that the quadrupolar picture is qualitatively wrong. At typical π-stacking distances, quadrupolar electrostatics may differ in sign from an exact calculation based on charge densities of the interacting arenes. We apply symmetry-adapted perturbation theory to dimers composed of substituted benzene and various aromatic heterocycles, which display a wide range of electrostatic interactions, and we investigate the interplay of Pauli repulsion, dispersion, and electrostatics as it pertains to parallel-displaced π-stacking. Profiles of energy components along cofacial slip-stacking coordinates support a prominent role for the “van der Waals model” (dispersion in competition with Pauli repulsion), even for polar monomers where electrostatic interactions are significant. While electrostatic interactions are necessary to explain the optimal face-to-face π-stacking distance and to account for the relative orientation of one polar arene with respect to another, we find no evidence to support continued invocation of quadrupolar electrostatics as a basis for π-stacking. Our results suggest that a driving force for offset-stacking exists even in the absence of electrostatic interactions. Consequently, tuning electrostatics via functionalization does not guarantee that slip-stacking can be avoided. This has implications for rational design of soft materials and other supramolecular architectures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Emergent layer stacking arrangements in c-axis confined MoTe 2

The layer stacking order in 2D materials strongly affects functional properties and holds promise for next-generation electronic devices. In bulk, octahedral MoTe 2 possesses two stacking arrangements, the ferroelectric Weyl semimetal T d phase and the higher-order topological insulator 1T' phase. However, in thin flakes of MoTe 2 , it is unclear if the layer stacking follows the T d , 1T', or an alternative stacking sequence. Here, we use atomic-resolution scanning transmission electron microscopy to directly visualize the MoTe 2 layer stacking. In thin flakes, we observe highly disordered stacking, with nanoscale 1T' and T d domains, as well as alternative stacking arrangements not found in the bulk. We attribute these findings to intrinsic confinement effects on the MoTe 2 stacking-dependent free energy. Our results are important for the understanding of exotic physics displayed in MoTe 2 flakes. More broadly, this work suggests c-axis confinement as a method to influence layer stacking in other 2D materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Reinterpreting π-stacking

The nature of π–π interactions has long been debated. The term “π-stacking” is considered by some to be a misnomer, in part because overlapping π-electron densities are thought to incur steric repulsion, and the physical origins of the widely-encountered “slip-stacked” motif have variously been attributed to either sterics or electrostatics, in competition with dispersion. Here, we use quantum-mechanical energy decomposition analysis to investigate π–π interactions in supramolecular complexes of polycyclic aromatic hydrocarbons, ranging in size up to realistic models of graphene, and for comparison we perform the same analysis on stacked complexes of polycyclic saturated hydrocarbons, which are cyclohexane-based analogues of graphane. Our results help to explain the short-range structure of liquid hydrocarbons that is inferred from neutron scattering, trends in melting-point data, the interlayer separation of graphene sheets, and finally band gaps and observation of molecular plasmons in graphene nanoribbons. Analysis of intermolecular forces demonstrates that aromatic π–π interactions constitute a unique and fundamentally quantum-mechanical form of non-bonded interaction. Not only do stacked π–π architectures enhance dispersion, but quadrupolar electrostatic interactions that may be repulsive at long range are rendered attractive at the intermolecular distances that characterize π-stacking, as a result of charge penetration effects. The planar geometries of aromatic sp 2 carbon networks lead to attractive interactions that are “served up on a molecular pizza peel”, and adoption of slip-stacked geometries minimizes steric (rather than electrostatic) repulsion. The slip-stacked motif therefore emerges not as a defect induced by electrostatic repulsion but rather as a natural outcome of a conformational landscape that is dominated by van der Waals interactions (dispersion plus Pauli repulsion), and is therefore fundamentally quantum-mechanical in its origins. This reinterpretation of the forces responsible for π-stacking has important implications for the manner in which non-bonded interactions are modeled using classical force fields, and for rationalizing the prevalence of the slip-stacked π–π motif in protein crystal structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Air-Cooled Stack Freeze Tolerance

Air-cooled stack technology offers the potential for a simpler system architecture (versus liquid-cooled) for applications below 4 kilowatts. The combined cooling and cathode air allows for a reduction in part count and hence a lower cost solution. However, efficient heat rejection challenges escalate as power and ambient temperature increase. For applications in ambient temperatures below freezing, the air-cooled approach has additional challenges associated with not overcooling the fuel cell stack. The focus of this project was freeze tolerance while maintaining all other stack and system requirements. Through this project, Plug Power advanced the state of the art in technology for air-cooled PEM fuel cell stacks and related GenDrive material handling application fuel cell systems. This was accomplished through a collaborative work plan to improve freeze tolerance and mitigate freeze-thaw effect failure modes within innovative material handling equipment fuel cell systems designed for use in freezer forklift applications. Freeze tolerance remains an area where additional research and understanding can help fuel cells to become commercially viable. This project evaluated both stack level and system level solutions to improve fuel cell stack freeze tolerance. At this time, the most cost effective solutions are at the system level. The freeze mitigation strategies developed over the course of this project could be used to drive fuel cell commercialization. The fuel cell system studied in this project was Plug Power's commercially available GenDrive platform providing battery replacement for equipment in the material handling industry. The fuel cell stacks were Ballard's commercially available FCvelocity 9SSL (9SSL) liquid-cooled PEM fuel cell stack and FCvelocity 1020ACS (Mk1020) air-cooled PEM fuel cell stack.

08 HYDROGEN↗

Pressurized electrolysis stack with thermal expansion capability

The present techniques provide systems and methods for mounting an electrolyzer stack in an outer shell so as to allow for differential thermal expansion of the electrolyzer stack and shell. Generally, an electrolyzer stack may be formed from a material with a high coefficient of thermal expansion, while the shell may be formed from a material having a lower coefficient of thermal expansion. The differences between the coefficients of thermal expansion may lead to damage to the electrolyzer stack as the shell may restrain the thermal expansion of the electrolyzer stack. To allow for the differences in thermal expansion, the electrolyzer stack may be mounted within the shell leaving a space between the electrolyzer stack and shell. The space between the electrolyzer stack and the shell may be filled with a non-conductive fluid to further equalize pressure inside and outside of the electrolyzer stack.

08 HYDROGEN↗

Stacking Fault Induced Symmetry Breaking in van der Waals Nanowires

While traditional ferroelectrics are based on polar crystals in bulk or thin film form, two-dimensional and layered materials can support mechanisms for symmetry breaking between centrosymmetric building blocks, e.g., by creating low-symmetry interfaces in van der Waals stacks. Here, we introduce an approach toward symmetry breaking in van der Waals crystals that relies on the spontaneous incorporation of stacking faults in a nonpolar bulk layer sequence. The concept is realized in nanowires consisting of Se-rich group IV monochalcogenide (GeSe 1–x S x ) alloys, obtained by vapor–liquid–solid growth. The single crystalline wires adopt a layered structure in which the nonpolar A-B bulk stacking along the nanowire axis is interrupted by single-layer stacking faults with local A-A' stacking. Density functional theory explains this behavior by a reduced stacking fault formation energy in GeSe (or Se-rich GeSe 1–x S x alloys). Computations demonstrate that, similar to monochalcogenide monolayers, the inserted A-layers should show a spontaneous electric polarization with a switching barrier consistent with a Curie temperature above room temperature. Second-harmonic generation signals are consistent with a variable density of stacking faults along the wires. Here, our results point to possible routes for designing ferroelectrics via the layer stacking in van der Waals crystals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Switching interlayer magnetic order in bilayer CrI 3 by stacking reversal

CrI 3 , a hot two-dimensional (2D) magnet, exhibits complex magnetism depending on the number of layers and interlayer stacking patterns. For bilayer CrI 3 , the interlayer magnetism can be tuned between ferromagnetic (FM) and antiferromagnetic (AFM) order by manipulating the stacking order. However, the stacking is mostly modified through translation between the layers, while the effect of rotation between the layers on the interlayer magnetic order has not yet been fully investigated. Here, we considered three energetically stable stacking patterns R$\bar3$ with combining macron], C2/m and AA in bilayer CrI 3 , and their reversed counterparts R$\bar3$ with combining macron]-r, C2/m-r and AA-r through rotating one layer by 180° with respect to the other layer. Our first-principles calculations suggest that the interlayer magnetic ground state can be switched from AFM to FM (or FM to AFM) by reversing the stacking pattern. A detailed microscopic analysis was carried out by magnetic force theory calculations on C2/m stacking which favors AFM and C2/m-r stacking which favors FM. The interlayer magnetic interactions and the origin of the magnetic order change were revealed through specific orbital analysis. Our work demonstrates that stacking rotation can also tune the interlayer magnetism of CrI 3 and provides insight into its interlayer magnetic properties at the microscopic level.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Assessment of the Revised 3410 Building Filtered Exhaust Stack Sampling Probe Location

In order to support the air emissions permit for the 3410 Building, Pacific Northwest National Laboratory performed a series of tests in the exhaust air discharge from the reconfigured 3410 Building Filtered Exhaust Stack. The objective was to determine whether the location of the air sampling probe for emissions monitoring meets the applicable regulatory criteria governing such effluent monitoring systems. In particular, the capability of the air sampling probe location to meet the acceptance criteria of ANSI/HPS N13.1-2011 , Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities was determined. The qualification criteria for these types of stacks address 1) uniformity of air velocity, 2) sufficiently small flow angle with respect to the axis of the duct, 3) uniformity of tracer gas concentration, and 4) uniformity of tracer particle concentration. Testing was performed to conform to the quality requirements of NQA-1-2000. Fan configurations tested included all fan combinations of any two fans at a time. Most of the tests were conducted at the normal flow rate, while a small subset of tests was performed at a slightly higher flow rate achieved with the laboratory hood sashes fully open. The qualification criteria for an air monitoring probe location are taken from ANSI/HPS N13.1-2011 and are paraphrased as follows with key results summarized: 1. Angular Flow—The average air velocity angle must not deviate from the axis of the stack or duct by more than 20°. Our test results show that the mean angular flow angles at the center two-thirds of the ducts are smaller than 4.5% for all testing conditions. 2. Uniform Air Velocity—The acceptance criterion is that the COV of the air velocity must be ≤ 20% across the center two thirds of the area of the stack. Our results show that the COVs of the air velocity across the center two-thirds of the stack are smaller than 2.9% for all testing conditions. 3. Uniform Concentration of Tracer Gases—The uniformity of the concentration of potential contaminants is first tested using a tracer gas to represent gaseous effluents. The tracer is injected downstream of the fan outlets and at the junction downstream fan discharges meet. The acceptance criteria are that 1) the COV of the measured tracer gas concentration is ≤20% across the center two-thirds of the sampling plane and 2) at no point in the sampling plane does the concentration vary from the mean by >30%. Our test results show that 1) the COV of the measured tracer gas concentration is < 2.9% for all test conditions and 2) at no point in the sampling plane does the concentration vary from the mean by >6.5%. 4. Uniform Concentration of Tracer Particles—Tracer particles of 10-μm aerodynamic diameter are used for the second demonstration of concentration uniformity. The acceptance criterion is that the COV of particle concentration is ≤ 20% across the center two thirds of the sampling plane. Our test results indicate that the COV of particle concentration is <9.9% across the center two-thirds of the sampling plane among all testing conditions. Thus, the reconfigured 3410 Building Filtered Exhaust Stack was determined to meet the qualification criteria given in the ANSI/HPS N13.1-2011 standard. Changes to the system configuration or operations outside the bounds described in this report (e.g., exhaust stack velocity changes, relocation of sampling probe, and addition of fans) may require re-testing or re-evaluation to determine compliance.

3410 building↗

Stack Characterization System Development and Testing

Oak Ridge National Laboratory, as well as the rest of the U.S. Department of Energy community, has numerous off-gas stacks that need to be decommissioned, demolished, and packaged for disposal. Disposal requires a waste disposition determination phase. Process knowledge typically makes a worst-case scenario decision that may place lower-level waste into a more expensive higher-level waste disposal category. Truly useful radiological and chemical sampling can be problematic on old stacks due to their inherent height and access hazards, and many of these stacks have begun to deteriorate structurally. A remote stack characterization system (SCS) that can manage sample and data collection removes people from the hazards and provides an opportunity for access to difficult to reach internal stack areas. The SCS is a remotely operated articulated radiological data recovery system designed to deploy down into off-gas stacks from the top via crane. The battery-powered SCS is designed to stabilize itself against the stack walls and move various data recovery systems into areas of interest on the inner stack walls. Stabilization is provided by a tripod structure; sensors are mounted in a rotatable bipod underneath the tripod. Sensors include a beta/gamma/alpha detector, a removable contaminant multi-sample automated sampler, and a multi-core remote core drill. Multiple cameras provide remote task viewing, support for sampling, and video documentation of the process. A delay in funding has delayed project delivery somewhat. Therefore, this paper describes the technology and shows fabrication and testing progress to the extent that data is available.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Direct Manufacturing Cost Model for Solid‐Oxide Fuel Cell Stacks

Abstract This work details efforts to estimate the direct manufacturing cost of solid oxide fuel cell (SOFC) stack components for combined heat and power applications. The main research goals are to identify the major contributors to fuel cell stack manufacturing costs, examine the influence of both production volume and stack size on cost, and compare the results of the cost trajectories with the U.S. Department of Energy SOFC stack manufacturing cost target of $238 kWe −1 (in 2015) and industry reported cost projections and to identify critical areas for manufacturing research and development. Stack component direct manufacturing costs are modeled for net electricity capacity of 1, 10, 50, 100 and 250 kWe across annual production volumes of 10, 1,000, 10,000 and 50,000 systems per year. Overall stack manufacturing costs range from $5,387 kWe −1 to a minimum of about $166 kWe −1 for a 250 kWe system at 50,000 systems per year. To meet the manufacturing cost target of $238 kWe −1 , a minimum annual production of 100–250 MWe per year would be required. Reduction opportunities for stack cost are expected to be available, mainly with the adoption of thinner cells and stack components, higher levels of factory automation, and more sensitive in‐line defect diagnostics.

Scataglini, R.↗