Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STABILITY TEST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Microinvertebrates in CELSS Hydroponic Rhizosphere: Experimental Invasion as a Test of Community Stability and a Test of a Method to Measure Bacterivory

This report consists of two separate draft manuscripts, each prepared for submittal to a peer-reviewed journal after Kennedy Space Center (KSC) colleague editorial review and final revision. References for the two papers have been combined in this report. The two manuscripts are: (1) Experimental invasion of aquatic rhizosphere habitat and invertebrate communities, and (2) Lysozyme analysis is neither protistan- or bacteriore-specific.

Sager, John↗

Elimination of High-Frequency Combustion Instability in the Fastrac Engine Thrust Chamber

A series of tests were conducted to stabilize the combustion of the Fastrac engine thrust chamber. The first few stability tests resulted in unstable combustion due ineffective acoustic cavity designs. The thrust chamber exhibited unstable combustion in the first-tangential mode and its harmonics. Combustion was stabilized by increasing the volume of the acoustic cavities and by plugging the dump-cooling orifices so that the cavities were uncooled. Although the first few stability tests resulted in unstable combustion, prior and subsequent long-duration performance tests of the Fastrac thrust chamber were spontaneously stable. Stability considerations during the injector faceplate design were based on the Hewitt correlation.

Rocker, Marvin↗

Elimination of High-Frequency Combustion Instability in the Fastrac Engine Thrust Chamber

A series of tests were conducted to stabilize the combustion of the Fastrac engine thrust chamber. The first few stability tests resulted in unstable combustion due ineffective acoustic cavity designs. The thrust chamber exhibited unstable combustion in the first-tangential mode and its harmonics. Combustion was stabilized by increasing the volume of the acoustic cavities and by plugging the dump-cooling orifices so that the cavities were uncooled. Although the first few stability tests resulted in unstable combustion, prior and subsequent long-duration performance tests of the Fastrac thrust chamber were spontaneously stable. Stability considerations during the injector faceplate design were based on the Hewitt correlation.

Rocker, Marvin↗

Novel Transparent Phosphor Conversion Matrix with High Thermal Conductivity for Next Generation Phosphor-Converted LED-based Solid State Lighting

The low thermal conductivity of state-of-the-art polymer encapsulants (k ~ 0.15 Wm-1K-1) limits the efficiency and power density of current phosphor conversion light emitting diodes (pc-LEDs). The technical objective of this project was to demonstrate synthesis and processing schemes for the fabrication of polymer hybrid encapsulants with a thermal conductivity exceeding k = 0.4 Wm-1K-1 for LED applications. The ‘hybrid polymer’ approach encompasses the dispersion of high thermal conductivity particle fillers (zinc oxide, ZnO as well as the alpha-polymorph of alumina, Al2O3) within a polysiloxane matrix (poly(dimethylsiloxane), PDMS as well as poly(phenyl methyl siloxane), PPMS) to increase the thermal conductivity while maintaining optical transparency and photothermal stability at levels consistent with LED applications. To accomplish this goal, a novel synthesis method for the fabrication of nanosized ZnO particles was developed and a novel surface chemistry was established to modify the surface of zinc oxide particle fillers and thus to enable their dispersion in poly(dimethyl siloxane) (PDMS) matrix polymers. Molecular dynamics and Mie simulations were used to optimize ligand structure and to enable the concurrent mixing of particles in PDMS/PPMS embedding media while also minimizing the thermal boundary resistance as well as optical scattering of particle fillers. Using this approach the synthesis of PDMS/ZnO hybrid encapsulants exhibiting a thermal conductivity of 0.64 Wm-1K-1 and optical transparency > 0.7 mm-1 was demonstrated. A forming process based on micromolding was developed to demonstrate the forming of particle filled PDMS into film and lens shapes. Photothermal stability testing revealed stability of the materials for approximately 4000 min when exposed to blue light LED (450 nm, 30 W/cm2). One postgraduate and seven graduate students were supported by the project. The research performed within this project led to fifteen publications in peer-reviewed journals and one patent application. The grant stimulated a multi-investigator research collaborations among seven investigators at Carnegie Mellon University to address the challenge of encapsulants in pc-LED applications. The grant also catalyzed the future collaboration between researchers at Carnegie Mellon University and OSRAM Sylvania to address challenges associated with the use if polymers in LED applications.

36 MATERIALS SCIENCE↗

Liquid organic foams for formulation optimization : an assessment of foam linear viscoelasticity and its temporal dependence.

Liquid foams are viscoelastic liquids, exhibiting a fast relaxation attributed to local bubble motions and a slow response due to structural evolution of the intrinsically unstable system. In this work, these processes are examined in unique organic foams that differ from the typically investigated aqueous systems in two major ways: the organic foams (1) posses a much higher continuous phase viscosity and (2) exhibit a coarsening response that involves coalescence of cells. The transient and dynamic relaxation responses of the organic foams are evaluated and discussed in relation to the response of aqueous foams. The change in the foam response with increasing gas fraction, from that of a Newtonian liquid to one that is strongly viscoelastic, is also presented. In addition, the temporal dependencies of the linear viscoelastic response are assessed in the context of the foam structural evolution. These foams and characterization techniques provide a basis for testing stabilization mechanisms in epoxy-based foams for encapsulation applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stability, reliability and cross-mode correlations of tests in a recommended 8-minute performance assessment battery

A need exists for an automated performance test system to study drugs, agents, treatments, and stresses of interest to the aviation, space, and environmental medical community. The purpose of this present study is to evaluate tests for inclusion in the NASA-sponsored Automated Performance Test System (APTS). Twenty-one subjects were tested over 10 replications with tests previously identified as good candidates for repeated-measure research. The tests were concurrently administered in paper-and-pencil and microcomputer modes. Performance scores for the two modes were compared. Data from trials 1 to 10 were examined for indications of test stability and reliability. Nine of the ten APT system tests achieved stability. Reliabilities were generally high. Cross-correlation of microbased tests with traditional paper-and-pencil versions revealed similarity of content within tests in the different modes, and implied at least three cognition and two motor factors. This protable, inexpensive, rugged, computerized battery of tests is recommended for use in repeated-measures studies of environmental and drug effects on performance. Identification of other tests compatible with microcomputer testing and potentially capable of tapping previously unidentified factors is recommended. Documentation of APTS sensitivity to environmental agents is available for more than a dozen facilities and is reported briefly. Continuation of such validation remains critical in establishing the efficacy of APTS tests.

Wilkes, R. L.↗

Testing the stability of magnetic iron oxides/kaolinite nanocomposite under various pH conditions

Magnetically modified clays containing iron oxides nanoparticles (Fe{sub x}O{sub y} NPs) are low-cost and environmentally harmless materials suitable for sorption of pollutants from wastewaters. Stability of this smart material was evaluated both experimentally and theoretically using molecular modelling. Original kaolinite and prepared Fe{sub x}O{sub y}/kaolinite nanocomposite were characterized using X-ray fluorescence spectroscopy, X-ray powder diffraction, infrared spectroscopy, and transmission electron microscopy, and the stability was studied using leaching tests performed according to the European technical standard EN 12457-2 in deionized water and extraction agents with varying pH (2, 4, 9, and 11). The influence of pH on amount of Fe{sub x}O{sub y} NPs released from the composite and amount of the basic elements released from the kaolinite structure was studied using inductively coupled plasma atomic emission spectroscopy. All experiments proved that the magnetic properties of the nanocomposite will not change even after leaching in extraction agents with various pH. - Graphical abstract: The stability of magnetic Fe{sub x}O{sub y}/kaolinite nanocomposite was studied using molecular modelling and leaching tests under various pH conditions. Display Omitted - Highlights: • Magnetization by Fe{sub x}O{sub y} nanoparticles did not influenced the structure of the kaolinite. • Maghemite (γ-Fe{sub 2}O{sub 3}) and mainly magnetite (Fe{sub 3}O{sub 4}) phases were detected. • Leaching test confirmed good adhesion of Fe{sub x}O{sub y} nanoparticles on kaolinite. • Molecular modelling of kaolinite/Fe{sub x}O{sub y} nanocomposite agrees well with experiments. • Nanocomposite can be considered stable in the wide range of pH.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The structural behavior of a graphite-polymide honeycomb sandwich panel with quasi-isotropic face sheets and an orthotropic core

The results of a series of tests of graphite-polyimide honeycomb sandwich panels are presented. The panels were 1.22 m long, 0.508 m wide, and approximately 13.3 m thick. The face sheets were a T-300/PMR-15 fabric in a quasi-isotropic layup and were 0.279 mm thick. The core was Hexcel HRH 327-3/16 - 4.0 glass reinforced polyimide honeycomb, 12.7 mm thick. Three panels were used in the test: one was cut into smaller pieces for testing as beam, compression, and shear specimens; a second panel was used for plate bending tests; the third panel was used for in-plane stability tests. Presented are the experimental results of four point bending tests, short block compression tests, core transverse shear modulus, three point bending tests, vibration tests, plate bending tests, and panel stability tests. The results of the first three tests are used to predict the results of some of the other tests. The predictions and experimental results are compared, and the agreement is quite good.

Hyer, M. W.↗

Development of a Test for Evaluation of the Hydrothermal Stability of Sorbents Used in Closed-Loop CO2 Removal Systems

The International Space Station Carbon Dioxide Removal Assembly uses zeolite 5A molecular sieve material packed into beds for the capture of cabin CO2. The beds are cyclically heated to drive off the CO2 and restore the removal capacity. Over time, the sorbent material has been found to break down resulting in dust that restricts flow through the beds. Humidity adsorbed in the 5A zeolite when it is heated is a suspected cause of this sorbent degradation. To evaluate the impact of adsorbed water during thermal cycling, the Hydrothermal Stability Test was developed. The test configuration provides comparative side-by-side flow restriction data for two sorbent materials at specifically controlled humidity levels. While the initial focus of the testing is on 5A zeolite materials currently used on the ISS, the system will also be used to evaluate future candidate materials. This paper describes the approach, the test system, current results, and future testing.

Knox, James C.↗

Development of a menu of performance tests self-administered on a portable microcomputer

Eighteen cognitive, motor, and information processing performance subtests were screened for self-administration over 10 trials by 16 subjects. When altered presentation forms of the same test were collectively considered, the battery composition was reduced to 10 distinctly different measures. A fully automated microbased testing system was employed in presenting the battery of subtests. Successful self-administration of the battery provided for the field testing of the automated system and facilitated convenient data collection. Total test administration time was 47.2 minutes for each session. Results indicated that nine of the tests stabilized, but for a short battery of tests only five are recommended for use in repeated-measures research. The five recommended tests include: the Tapping series, Number Comparison, Short-term Memory, Grammatical Reasoning, and 4-Choice Reaction Time. These tests can be expected to reveal three factors: (1) cognition, (2) processing quickness, and (3) motor. All the tests stabilized in 24 minutes, or approximately two 12-minute sessions.

Wilkes, Robert L.↗

Air and radon pathways screenings methodologies for the next revision of the E-area PA

The strategic plan for the next E-Area Low-Level Waste Facility Performance Assessment includes recommended changes to the screening criteria used to reduce the number of radioisotopes that are to be considered in the air and radon pathways incorporated into the GoldSim® atmospheric release model (ARM). For the air pathway, a revised screening methodology was developed based on refinement of previous E-Area PA screening approaches and consideration of the strategic plan recommendations. The revised methodology has three sequential screening steps for each radioisotope: (1) volatility test using the Periodic Table of the Elements, (2) stability test based on half-life, and (3) stability test based on volatility as measured by the Henry’s Law constant for the assumed dominant gaseous species or vapor pressure in the case of tritiated water. Of the 1252 radioisotopes listed in the International Commission on Radiological Protection Publication 107, only the 10 that satisfied all three steps of the revised screening methodology will be included in the ARM. They are: Ar-37, Ar-39, Ar-42, C-14, H-3, Hg-194, Hg-203, Kr-81, Kr-85, and Xe-127. For the radon pathway, a revised screening methodology was developed that also has three sequential steps: (1) identify all decay chains that terminate at Rn-222, (2) screen out parents that decay through U-238 because of its 4.5-billion-year primordial half-life, and (3) eliminate remaining parents whose half-life is shorter than one day. Of the 86 possible decay chains leading to Rn-222, six decay chains consist of 15 unique radioisotopes that will be incorporated into the ARM. The 15 radioisotopes are: U-238, Th-234, Pa-234m, Pu-238, U-234, Th-230, Ra-226, Cf-246, Cm-242, Am-242m, Am-242, Np-238, Np-234, Pa-230, and Rn-222.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stability of Pharmaceuticals in Space

Stability testing is a tool used to access shelf life and effects of storage conditions for pharmaceutical formulations. Early research from the International Space Station (ISS) revealed that some medications may have degraded while in space. This potential loss of medication efficacy would be very dangerous to Crew health. The aim of this research project, Stability of Pharmacotherapeutic Compounds, is to study how the stability of pharmaceutical compounds is affected by environmental conditions in space. Four identical pharmaceutical payload kits containing medications in different dosage forms (liquid for injection, tablet, capsule, ointment and suppository) were transported to the ISS aboard a Space Shuttle. One of the four kits was stored on that Shuttle and the other three were stored on the ISS for return to Earth at various time intervals aboard a pre-designated Shuttle flight. The Pharmacotherapeutics laboratory used stability test as defined by the United States Pharmacopeia (USP), to access the degree of degradation to the Payload kit medications that may have occurred during space flight. Once these medications returned, the results of stability test performed on them were compared to those from the matching ground controls stored on Earth. Analyses of the results obtained from physical and chemical stability assessments on these payload medications will provide researchers additional tools to promote safe and efficacious medications for space exploration.

Nguyen, Y-Uyen↗

Perovskite on Silicon Tandem Solar Cells

Since installing solar panels costs more than the panels themselves, it is critically important to improve the efficiency of the panels so that fewer panels need to be installed. More than 90% of all panels being manufactured are made with silicon solar cells. The most promising approach to reach 27% is to upgrade the panels by adding a second set of cells with a larger band gap that can harvest the higher energy photons in the visible spectrum and generate a higher voltage than silicon is capable of generating. Perovskite semiconductors are very promising for low-cost tandems because they have high band gaps, can be rapidly printed from solutions and have been used to make 25% efficient cells by themselves. If we show that it is possible to make stable tandems with 30% efficiency using materials that could be deposited at low cost and that the energy yield will not be compromised, then private companies would be able to raise the capital needed to manufacture this technology. The main metrics for this project are the power conversion efficiency of a lab-scale perovskite/silicon tandem and the ability to maintain a high power conversion efficiency in perovskite solar cells after accelerated operational stability testing under maximum power point at elevated temperature and 1 sun illumination. In short, this project demonstrates improvements to the perovskite absorber layer, contacts for the perovskite solar cell, and transparent oxide layers for window electrodes to achieve tandem efficiencies of 25% after one year and 27% after two years. By the end of the project, we identify strategies to further improve light management in the tandem devices and outline a pathway to reach 30%.In parallel, stability testing is conducted to evaluate said absorber and contact layers in the perovskite top cell, demonstrating 1000 hours of operation with less than 10% degradation at 1 sun. Our work on this project has made a leading impact on the development of perovskite/silicon tandems. The triple halide perovskite that we developed using iodide, bromide, and chloride and published in Science in March 2020 has received significant interest from other experts in the field at conferences. We took a silicon bottom cell with 21% efficiency, a technology that is responsible for a $30 billion market, and improved it by 30% relative. In addition, we have demonstrated impressive stability of our perovskite semitransparent top cells used in the tandems, showing for the first time packaged devices that pass a variety of IEC stability tests including damp heat, temperature cycling, and UV exposure tests.

14 SOLAR ENERGY↗

Evaluation of tests for vestibular function

Vestibular testing methodologies are examined in terms of their clinical value and applicability to the assessment of astronaut candidates and human responses to microgravity. Classical and novel testing approaches are examined in terms of nine functions such as otolith organs, vestibular neural processing, and ocular motor systems. The tests reviewed include the basic vestibular-function test battery, postural stability testing, visual-vestibular interaction, reactions to off-axis rotation, and vestibular evoked responses. The basic test battery is shown to be essential for astronaut and inertial-environment baseline-data evaluations, whereas the newer and research tests are only recommended in special cases. Stimulus rearrangement and motion-sickness tests are indicated for testing adaptation to inertial environments. Postural stability and visual-vestibular interaction are recommended for evaluating one's suitability for being an astronaut.

Source record↗

Supersonic Jet Tests of Missile Stabilizers

Seven stabilizers were tested at a Mach number of 2 in order to determine the effects of aerodynamic heating and loading on the structural stability of the stabilizer. The models differed in internal structure and postcure temperatures of the laminated Fiberglass skin. Tests were made at various stagnation temperatures between 440 F and 625 F. The postcure temperatures of the Fiberglass skins were found to affect significantly the ability of the model to withstand the imposed test conditions.

Vosteen, Louis F.↗