Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SQUIDs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Robust and symmetric magnetic field dependency of superconducting diode effect in asymmetric Dirac semimetal SQUIDs

The recent demonstration of the superconducting diode effect (SDE) has generated renewed interest in superconducting electronics, in which devices such as compact superconducting diodes that can perform signal rectification with low-energy operations are needed. In this article, we present our results of robust and symmetric-in-magnetic-field SDE in asymmetric superconducting quantum interference devices (SQUIDs) realized in high-quality Dirac semimetal Cd 3 As 2 thin film grown by the molecular beam epitaxy technique. Consistent with previous work, a zero magnetic field SDE is observed. Furthermore, the difference in switching current is independent of the strength and polarity of an out-plane magnetic field in the range of −10 and 10 mT. We speculate that this robust symmetric-in-field SDE in our Dirac semimetal SQUIDs is due to the formation of helical spin texture, theoretically predicted in Dirac semimetals.

Current-voltage characteristic↗

Quantum Machine Learning with SQUID

In this work we present the Scaled QUantum IDentifier (SQUID), an open-source framework for exploring hybrid Quantum-Classical algorithms for classification problems. The classical infrastructure is based on PyTorch and we provide a standardized design to implement a variety of quantum models with the capability of back-propagation for efficient training. We present the structure of our framework and provide examples of using SQUID in a standard binary classification problem from the popular MNIST dataset. In particular, we highlight the implications for scalability for gradient-based optimization of quantum models on the choice of output for variational quantum models.

97 MATHEMATICS AND COMPUTING↗

Induced electric currents in the Alaska oil pipeline measured by gradient, fluxgate, and SQUID magnetometers

The field gradient method for observing the electric currents in the Alaska pipeline provided consistent values for both the fluxgate and SQUID method of observation. These currents were linearly related to the regularly measured electric and magnetic field changes. Determinations of pipeline current were consistent with values obtained by a direct connection, current shunt technique at a pipeline site about 9.6 km away. The gradient method has the distinct advantage of portability and buried- pipe capability. Field gradients due to the pipe magnetization, geological features, or ionospheric source currents do not seem to contribute a measurable error to such pipe current determination. The SQUID gradiometer is inherently sensitive enough to detect very small currents in a linear conductor at 10 meters, or conversely, to detect small currents of one amphere or more at relatively great distances. It is fairly straightforward to achieve imbalance less than one part in ten thousand, and with extreme care, one part in one million or better.

Campbell, W. H.↗

SQUID readout and ultra-low magnetic fields for Gravity Probe-B (GP-B)

The superconducting readout system to be used for resolving 0.001 arcsec changes in the gyroscope spin direction in the Relativity Gyroscope (GP-B) experiment is described. This system couples the London magnetic moment flux of the spinning gyro to a low noise superconducting quantum interference device (SQUID) detector. Resolution limits and noise performance of the detection system are discussed, and improvements obtained and expected with advanced SQUIDs are presented. Also described is the novel use of superconducting magnetic shielding techniques to obtain a 250 dB attenuation of the earth's magnetic field at the location of the gyroscopes. In this approach, expanded superconducting foil shields are coupled with fixed cylindrical superconducting shields and special geometric considerations to obtain the extremely high attenuation factor required. With these shielding techniques, it appears that the 0.5-Gauss earth field (which appears to the gyroscopes as an ac field at the satellite roll rate) can be reduced to the 10 to the -13th G level required by the experiment. Recent results concerning improvements in the performance of the superconducting foil techniques obtained with the use of a new computer-controlled cooling system are presented.

Lockhart, James M.↗

A YBCO RF-squid variable temperature susceptometer and its applications

The Superconducting QUantum Interference Device (SQUID) susceptibility using a high-temperature radio-frequency (rf) SQUID and a normal metal pick-up coil is employed in testing weak magnetization of the sample. The magnetic moment resolution of the device is 1 x 10(exp -6) emu, and that of the susceptibility is 5 x 10(exp -6) emu/cu cm.

Zhou, Luwei↗

Low Temperature SQUID for NDE Applications

We have developed a low temperature SuperConducting Quantum Interference Device - SQUID measurement system for detection of defects deep under the surface of aluminum structures using eddy current techniques. The system uses a two dimensional planar inducer with two different excitation frequencies to induce a current in the sample. We have developed a data analysis software program that enabled us to distinguish between round defects (holes), straight defects (slots) and slots close to holes simulating cracks starting from rivets in aluminum structures. We were able to detect defects that are 8mm below the surface. We have also measured the change in phase of the detected signal as a function of depth of the defect. This relationship can be used to determine the depth of hidden flaws. Using this analysis software with the high temperature SQUID system at NASA Langley we were able to detect slots close to holes in layered aluminum sample.

Wincheski, Buzz↗

TES Detector Noise Limited Readout Using SQUID Multiplexers

The availability of superconducting Transition Edge Sensors (TES) with large numbers of individual detector pixels requires multiplexers for efficient readout. The use of multiplexers reduces the number of wires needed between the cryogenic electronics and the room temperature electronics and cuts the number of required cryogenic amplifiers. We are using an 8 channel SQUID multiplexer to read out one-dimensional TES arrays which are used for submillimeter astronomical observations. We present results from test measurements which show that the low noise level of the SQUID multiplexers allows accurate measurements of the TES Johnson noise, and that in operation, the readout noise is dominated by the detector noise. Multiplexers for large number of channels require a large bandwidth for the multiplexed readout signal. We discuss the resulting implications for the noise performance of these multiplexers which will be used for the readout of two dimensional TES arrays in next generation instruments.

Staguhn, J. G.↗

Enhancements to a Superconducting Quantum Interference Device (SQUID) Multiplexer Readout and Control System

Far-infrared detector arrays such as the 16x32 superconducting bolometer array for the SAFIRE instrument (flying on the SOFIA airborne observatory) require systems of readout and control electronics to provide translation between a user-driven, digital PC and the cold, analog world of the cryogenic detector. In 2001, the National Institute of Standards and Technology (NIST) developed their Mark III electronics for purposes of control and readout of their 1x32 SQUID Multiplexer chips. We at NASA s Goddard Space Flight Center acquired a Mark 111 system and subsequently designed upgrades to suit our and our collaborators purposes. We developed an arbitrary, programmable multiplexing system that allows the user to cycle through rows in a SQUID array in an infinite number of combinations. We provided hooks in the Mark III system to allow readout of signals from outside the Mark 111 system, such as telescope status information. Finally, we augmented the heart of the system with a new feedback algorithm implementation, flexible diagnostic tools, and informative telemetry.

Forgione, J.↗

Gradiometer Using Middle Loops as Sensing Elements in a Low-Field SQUID MRI System

A new gradiometer scheme uses middle loops as sensing elements in lowfield superconducting quantum interference device (SQUID) magnetic resonance imaging (MRI). This design of a second order gradiometer increases its sensitivity and makes it more uniform, compared to the conventional side loop sensing scheme with a comparable matching SQUID. The space between the two middle loops becomes the imaging volume with the enclosing cryostat built accordingly.

Penanen, Konstantin↗

Practical SQUID Instrument for Nondestructive Testing

We report on the development of a scanning eddy-current imaging system designed to detect deep subsurface flaws in conducting materials. A high transition temperature (high-T c) superconducting quantum interference device (SQUID) magnetometer is employed to provide the required sensitivity at low frequencies, while a combination of small cylindrical high-Tc superconducting and A-metal shields enable the instrument to be scanned in a magnetically noisy environment, rather than the object under test. The shields are arranged to prevent unwanted excitation and ambient noise fields from reaching the SQUID, and to enhance spatial resolution and minimize undesirable edge effects. Thus far, the instrument has successfully detected cracks and pits through 10 layers of aluminum, with a combined thickness of 5 cm at room temperature.

Tralshawala, N.↗

Squid detected NMR and MRI at ultralow fields

Nuclear magnetic resonance (NMR) signals are detected in microtesla fields. Prepolarization in millitesla fields is followed by detection with an untuned dc superconducting quantum interference device (SQUID) magnetometer. Because the sensitivity of the SQUID is frequency independent, both signal-to-noise ratio (SNR) and spectral resolution are enhanced by detecting the NMR signal in extremely low magnetic fields, where the NMR lines become very narrow even for grossly inhomogeneous measurement fields. MRI in ultralow magnetic field is based on the NMR at ultralow fields. Gradient magnetic fields are applied, and images are constructed from the detected NMR signals.

47 OTHER INSTRUMENTATION↗

Bandwidth and Aliasing in the Microwave SQUID Multiplexer

The microwave SQUID multiplexer (μmux) has enabled higher bandwidth or higher channel counts across a wide range of experiments in particle physics, astronomy, and spectroscopy. The large multiplexing factor coupled with recent commercial availability of microwave components and warm electronics readout systems make it an attractive candidate for systems requiring large cryogenic detector counts. Since the multiplexer is considered for both bolometric and calorimetric applications across several orders of magnitude of signal frequencies, understanding the bandwidth of the device and its interaction with readout electronics is key to appropriately designing and engineering systems. Here we discuss several important factors contributing to the bandwidth properties of μmux systems, including the intrinsic device bandwidth, interactions with warm electronics readout systems, and aliasing. Further, we present simulations and measurements of μmux devices coupled with SLAC Microresonator RF (SMuRF) tone-tracking electronics and discuss several implications for future experimental design.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Crosstalk Effects in Microwave SQUID Multiplexed TES Bolometer Readout

Transition-edge sensor (TES) bolometers are broadly used for background-limited astrophysical measurements from the far-infrared to mm-waves. Many planned future instruments require increasingly large detector arrays, but their scalability is limited by their cryogenic readout electronics. Microwave SQUID multiplexing offers a highly capable scaling solution through the use of inherently broadband circuitry, enabling readout of hundreds to thousands of channels per microwave line. As with any multiplexing technique, the channelization mechanism gives rise to electrical crosstalk which must be understood and controlled so as to not degrade the instrument sensitivity. Here, in this study, we explore implications relevant for TES bolometer array applications, focusing in particular on upcoming mm-wave observatories such as the Simons Observatory and AliCPT. We model the relative contributions of the various underlying crosstalk mechanisms, evaluate the difference between fixed-tone and tone-tracking readout systems, and discuss ways in which crosstalk nonlinearity will complicate on-sky measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analytical results of the Fokker-Planck equation derived for one superconducting nanowire quantum interference device and for DC SQUIDs-asymmetric devices

We consider an asymmetric two-junction superconducting quantum interference device, whose junctions are assumed to be overdamped, and regard Sin Fourier series for their current-phase relations. We take into account the effects of thermal fluctuations by forming a two-dimensional Fokker-Planck equation for the distribution function. We judge a series expansion of first order with respect to the components of the reduced inductance for distribution function and obtain current-voltage relation. We consider the measured resistance of the superconducting nanowire quantum interference device with mesoscopic leads that Hopkins et al. reported in Hopkins et al. [D.S. Hopkins, D. Pekker, P.M. Goldbart, A. Bezryadin, Science 308 (2005) 1762] and analyzed in Pekker et al. [D. Pekker, A. Bezryadin, D.S. Hopkins, P.M. Goldbart, Phys. Rev. B 72 (2005) 104517], by defining loop inductance, and by considering appropriate relations for resistance of nanowires. In fact we extend Chesca formulation [B. Chesca, J. Low Temp. Phys. 112 (1998) 165] simultaneously in three aspects and give a unified theory for nanowire two-junction devices, low T{sub c} and high T{sub c} DC SQUIDs, in restricted conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spin transition in Gd{sub 3}N-C{sub 80}, detected by low-temperature on-chip SQUID technique

We present a magnetic study of the Gd{sub 3}N-C{sub 80} molecule, consisting of a Gd-trimer via a nitrogen atom, encapsulated in a C{sub 80} cage. This molecular system can be an efficient contrast agent for magnetic resonance imaging (MRI) applications. We used a low-temperature technique able to detect small magnetic signals by placing the sample in the vicinity of an on-chip SQUID. The technique implemented at the National High Magnetic Field Laboratory has the particularity of being able to operate in high magnetic fields of up to 7 T. The Gd{sub 3}N-C{sub 80} shows a paramagnetic behavior and we find a spin transition of the Gd{sub 3}N structure at 1.2 K. We perform quantum mechanical simulations, which indicate that one of the Gd ions changes from a {sup 8}S{sub 7/2} state (L = 0, S = 7/2) to a {sup 7}F{sub 6} state (L = S = 3, J = 6), likely due to a charge transfer between the C{sub 80} cage and the ion.

36 MATERIALS SCIENCE↗

An interchangeable scanning Hall probe/scanning SQUID microscope

We have constructed a scanning probe microscope for magnetic imaging, which can function as a scanning Hall probe microscope (SHPM) and as a scanning SQUID microscope (SSM). The scanning scheme, applicable to SHPM and SSM, consists of a mechanical positioning (sub) micron-XY stage and a flexible direct contact to the sample without a feedback control system for the Z-axis. With the interchangeable capability of operating two distinct scanning modes, our microscope can incorporate the advantageous functionalities of the SHPM and SSM with large scan range up to millimeter, high spatial resolution (⩽4 μm), and high field sensitivity in a wide range of temperature (4.2 K-300 K) and magnetic field (10{sup −7} T-1 T). To demonstrate the capabilities of the system, we present magnetic images scanned with SHPM and SSM, including a RbFeB magnet and a nickel grid pattern at room temperature, surface magnetic domain structures of a La{sub 2/3}Ca{sub 1/3}MnO{sub 3} thin film at 77 K, and superconducting vortices in a striped niobium film at 4.2 K.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Trace element content and magnetic properties of commercial HOPG samples studied by ion beam microscopy and SQUID magnetometry

In this study, the impurity concentration and magnetic response of nine highly oriented pyrolytic graphite (HOPG) samples with different grades and from different providers were determined using ion beam microscopy and SQUID magnetometry. Apart from sideface contaminations in the as-received state, bulk contamination of the samples in most cases consists of disk-shaped micron-sized particles made of Ti and V with an additional Fe contamination around the grain perimeter. The saturation magnetization typically increases with Fe concentration, however, there is no simple correlation between Fe content and magnetic moment. The saturation magnetization of one, respectively six, out of nine samples clearly exceeds the maximum contribution from pure Fe or Fe{sub 3}C. For most samples the temperature dependence of the remanence decreases linearly with T – a dependence found previously for defect-induced magnetism (DIM) in HOPG. We conclude that apart from magnetic impurities, additional contribution to the ferromagnetic magnetization exists in pristine HOPG in agreement with previous studies. A comparative study between the results of ion beam microscopy and the commonly used EDX analysis shows clearly that EDX is not a reliable method for quantitative trace elemental analysis in graphite, clarifying weaknesses and discrepancies in the element concentrations given in the recent literature.

36 MATERIALS SCIENCE↗

SQUID-Detected MRI in the Limit of Zero Static Field

This thesis describes an implementation of the so-called"zero-field MRI" (ZFMRI) pulse sequence, which allows for imaging in an arbitrarily low B 0 field. The ZFMRI sequence created an effective unidirectional gradient field by using a train of pi pulses to average out the concomitant gradient components during encoding. The signals were acquired using a low-transition temperature dc Superconducting QUantum Interference Device (low-Tc dc SQUID) coupled to a first-order axial gradiometer. The experiments were carried out in a liquid helium dewar which was magnetically shielded with a single-layer mu-metal can around the outside and a superconducting Pb can contained within the helium space. We increased the filling factor of the custom-made, double-walled Pyrex insert by placing the liquid alcohol sample, at a temperature of approximately -50 degrees C, at the center of one loop of the superconducting gradiometer, which was immersed in the helium bath.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗