Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SPEED OF LIGHT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Bubble core field modification by residual electrons inside the bubble

Bubble core field modification due to the nondepleted electrons present inside the bubble is investigated theoretically. These residual electrons induce charge and current densities that can induce the bubble core field modification as well as the bubble shape change. It is found that the electrons entering into the bubble move backward at almost light speed and would weaken the transverse bubble fields. This reduces the ratio of longitudinal to transverse radius of the bubble. For the longitudinal bubble field, two effects compensate with each other because of their competition between the enhancement by the shortening of bubble shape and the reduction by the residual electrons. Therefore the longitudinal field is hardly changeable. As a comparison we perform particle-in-cell simulations and it is found that the results from theoretical consideration are consistent with simulation results. Implication of the modification of fields on bubble electron acceleration is also discussed briefly.

43 PARTICLE ACCELERATORS↗

Ultrafast spontaneous emission modulation of graphene quantum dots interacting with Ag nanoparticles in solution

We investigated the strong interaction between graphene quantum dots and silver nanoparticles in solution using time-resolved photoluminescence techniques. In solution, the silver nanoparticles are surrounded by graphene quantum dots and interacted with graphene quantum dots through exciton-plasmon coupling. An ultrafast spontaneous emission process (lifetime 27 ps) was observed in such a mixed solution. This ultrafast lifetime corresponds to the emission rate exceeding 35 GHz, with the purcell enhancement by a factor of ∼12. These experiment results pave the way for the realization of future high speed light sources applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

GALACTIC-CENTER S STARS AS A PROSPECTIVE TEST OF THE EINSTEIN EQUIVALENCE PRINCIPLE

The S stars in the Galactic-center region are found to be on near-perfect Keplerian orbits around presumably a supermassive black hole, with periods of 15-50 yr. Since these stars reach a few percent of light speed at pericenter, various relativistic effects are expected and have been discussed in the literature. We argue that an elegant test of the Einstein equivalence principle should be possible with existing instruments, through spectroscopic monitoring of an S star concentrated during the months around pericenter, supplemented with an already-adequate astrometric determination of the inclination. In essence, the spectrum of an S star can be considered a heterogeneous ensemble of clocks in a freely falling frame, which near pericenter is moving at relativistic speeds.

79 ASTRONOMY AND ASTROPHYSICS↗

SPECTRAL AND INTERMITTENCY PROPERTIES OF RELATIVISTIC TURBULENCE

High-resolution numerical simulations are utilized to examine isotropic turbulence in a compressible fluid when long-wavelength velocity fluctuations approach light speed. Spectral analysis reveals an inertial sub-range of relativistic motions with a broadly 5/3 index. The use of generalized Lorentz covariant structure functions based on the four-velocity is proposed. These structure functions extend the She-Leveque model for intermittency into the relativistic regime.

79 ASTRONOMY AND ASTROPHYSICS↗

Propagation of electromagnetic waves in resistive pair plasma and causal relativistic magnetohydrodynamics

We investigate the propagation of electromagnetic waves in resistive e{sup {+-}} pair plasmas using a one-fluid theory derived from the relativistic two-fluid equations. When the resistivity normalized by the electron/positron inertia variable exceeds a critical value, the dispersion relation for electromagnetic waves shows that the group velocity is larger than the light speed in vacuum. However, in such a case, it also is found that the plasma parameter is less than unity: that is, the electron-positron pair medium no longer can be treated as plasma. Thus, the simple two-fluid approximation is invalid. This confirms that superluminal propagation of electromagnetic wave is forbidden in a plasma--a conclusion consistent with the relativistic principle of causality. As an alternative, we propose a new set of equations for ''causal relativistic magnetohydrodynamics,'' which both have nonzero resistivity and yet are consistent with the causality principle.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-I-15: Quantitative Evaluation of Dose Distributions From Axial, Helical and Cone-Beam CT Imaging by Measurement Using a Two-Dimensional Diode-Array Detector

Purpose: To evaluate quantitatively dose distributions from helical, axial and cone-beam CT clinical imaging techniques by measurement using a two-dimensional (2D) diode-array detector. Methods: 2D-dose distributions from selected clinical protocols used for axial, helical and cone-beam CT imaging were measured using a diode-array detector (MapCheck2). The MapCheck2 is composed from solid state diode detectors that are arranged in horizontal and vertical lines with a spacing of 10 mm. A GE-Light-Speed CT-simulator was used to acquire axial and helical CT images and a kV on-board-imager integrated with a Varian TrueBeam-STx machine was used to acquire cone-beam CT (CBCT) images. Results: The dose distributions from axial, helical and cone-beam CT were non-uniform over the region-of-interest with strong spatial and angular dependence. In axial CT, a large dose gradient was measured that decreased from lateral sides to the middle of the phantom due to large superficial dose at the side of the phantom in comparison with larger beam attenuation at the center. The dose decreased at the superior and inferior regions in comparison to the center of the phantom in axial CT. An asymmetry was found between the right-left or superior-inferior sides of the phantom which possibly to angular dependence in the dose distributions. The dose level and distribution varied from one imaging technique into another. For the pelvis technique, axial CT deposited a mean dose of 3.67 cGy, helical CT deposited a mean dose of 1.59 cGy, and CBCT deposited a mean dose of 1.62 cGy. Conclusions: MapCheck2 provides a robust tool to measure directly 2D-dose distributions for CT imaging with high spatial resolution detectors in comparison with ionization chamber that provides a single point measurement or an average dose to the phantom. The dose distributions measured with MapCheck2 consider medium heterogeneity and can represent specific patient dose.

60 APPLIED LIFE SCIENCES↗

SU-E-T-503: Intensity Modulated Proton Therapy (IMPT) Versus Intensity Modulated X-Ray Therapy (IMRT) for Patient with Hepatocellular Carcinoma: A Dosimetric Comparison

Purpose This study compares the dosimetric parameters in treatment of unresectable hepatocellular carcinoma between intensity modulated proton therapy (IMPT) and intensity modulated x-ray radiation therapy (IMRT). Methods and Materials: We studied four patients treated at our institution. All patients were simulated supine with 4D-CT using a GE light speed simulator with a maximum slice thickness of 3mm. The average CT and an internal target volume to account for respiration motion were used for planning. Both IMRT and IMPT plans were created using Elekta’s CMSXiO treatment planning system (TPS). The prescription dose was 58.05 CGE in 15 fractions. The IMRT plans had five beams with combination of co-planar and non-co-planar. The IMPT plans had 2 to 3 beams. Dose comparison was performed based on the averaged results of the four patients. Results The mean dose and V95% to PTV were 58.24CGE, 98.57% for IMPT, versus 57.34CGE and 96.68% for IMRT, respectively. The V10, V20, V30 and mean dose of the normal liver for IMPT were 23.10%, 18.61%, 13.75% and 9.78 CGE; and 47.19%, 37.55%, 22.73% and 17.12CGE for IMRT. The spinal cord didn’t receive any dose in IMPT technique, but received a maximum of 18.77CGE for IMRT. The IMPT gave lower maximum dose to the stomach as compared to IMRT (19.26 vs 26.35CGE). V14 for left and right kidney was 0% and 2.32% for IMPT and 3.89% and 29.54% for IMRT. The mean dose, V35, V40 and V45 for small bowl were similar in both techniques, 0.74CGE, 6.27cc, 4.85cc and 3.53 cc for IMPT, 3.47CGE, 9.73cc, 7.61cc 5.35cc for IMRT. Conclusion Based on this study, IMPT plans gave less dose to the critical structures such as normal liver, kidney, stomach and spinal cord as compared to IMRT plans, potentially leading to less toxicity and providing better quality of life for patients.

60 APPLIED LIFE SCIENCES↗

Laser Wakefield Acceleration: Structural and Dynamic Studies. Final Technical Report ER40954

Particle accelerators enable scientists to study the fundamental structure of the universe, but have become the largest and most expensive of scientific instruments. In this project, we advanced the science and technology of laser-plasma accelerators, which are thousands of times smaller and less expensive than their conventional counterparts. In a laser-plasma accelerator, a powerful laser pulse exerts light pressure on an ionized gas, or plasma, thereby driving an electron density wave, which resembles the wake behind a boat. Electrostatic fields within this plasma wake reach tens of billions of volts per meter, fields far stronger than ordinary non-plasma matter (such as the matter that a conventional accelerator is made of) can withstand. Under the right conditions, stray electrons from the surrounding plasma become trapped within these “wake-fields”, surf them, and acquire energy much faster than is possible in a conventional accelerator. Laser-plasma accelerators thus might herald a new generation of compact, low-cost accelerators for future particle physics, x-ray and medical research. In this project, we made two major advances in the science of laser-plasma accelerators. The first of these was to accelerate electrons beyond 1 gigaelectronvolt (1 GeV) for the first time. In experimental results reported in Nature Communications in 2013, about 1 billion electrons were captured from a tenuous plasma (about 1/100 of atmosphere density) and accelerated to 2 GeV within about one inch, while maintaining less than 5% energy spread, and spreading out less than ½ milliradian (i.e. ½ millimeter per meter of travel). Low energy spread and high beam collimation are important for applications of accelerators as coherent x-ray sources or particle colliders. This advance was made possible by exploiting unique properties of the Texas Petawatt Laser, a powerful laser at the University of Texas at Austin that produces pulses of 150 femtoseconds (1 femtosecond is 10-15 seconds) in duration and 150 Joules in energy (equivalent to the muzzle energy of a small pistol bullet). This duration was well matched to the natural electron density oscillation period of plasma of 1/100 atmospheric density, enabling efficient excitation of a plasma wake, while this energy was sufficient to drive a high-amplitude wake of the right shape to produce an energetic, collimated electron beam. Continuing research is aimed at increasing electron energy even further, increasing the number of electrons captured and accelerated, and developing applications of the compact, multi-GeV accelerator as a coherent, hard x-ray source for materials science, biomedical imaging and homeland security applications. The second major advance under this project was to develop new methods of visualizing the laser-driven plasma wake structures that underlie laser-plasma accelerators. Visualizing these structures is essential to understanding, optimizing and scaling laser-plasma accelerators. Yet prior to work under this project, computer simulations based on estimated initial conditions were the sole source of detailed knowledge of the complex, evolving internal structure of laser-driven plasma wakes. In this project we developed and demonstrated a suite of optical visualization methods based on well-known methods such as holography, streak cameras, and coherence tomography, but adapted to the ultrafast, light-speed, microscopic world of laser-driven plasma wakes. Our methods output images of laser-driven plasma structures in a single laser shot. We first reported snapshots of low-amplitude laser wakes in Nature Physics in 2006. We subsequently reported images of high-amplitude laser-driven plasma “bubbles”, which are important for producing electron beams with low energy spread, in Physical Review Letters in 2010. More recently, we have figured out how to image laser-driven structures that change shape while propagating in a single laser shot. The latter techniques, which use the methods of computerized tomography, were demonstrated on test objects – e.g. laser-driven filaments in air and glass – and reported in Optics Letters in 2013 and Nature Communications in 2014. Their output is a multi-frame movie rather than a snapshot. Continuing research is aimed at applying these tomographic methods directly to evolving laser-driven plasma accelerator structures in our laboratory, then, once perfected, to exporting them to plasma-based accelerator laboratories around the world as standard in-line metrology instruments.

43 PARTICLE ACCELERATORS↗

Ghost particles and Project Poltergeist: Long-ago Lab physicists studied science that haunted them

A neutrino is a tiny, almost massless particle that travels at near light speeds. They were first formed in the early universe and are continually being produced in the nuclear reactions of stars, like the sun, and nuclear reactions on earth. The existence of these “ghost particles” was incredibly difficult to detect, but doing so has helped scientists better understand fundamental principles in physics. Los Alamos Manhattan Project scientist Frederick Reines, along with his colleague Clyde Cowan, is credited with the experimental discovery of the nearly massless elementary particle after his team definitively proved the neutrino’s existence in 1956. Reines received the Nobel Prize in Physics in 1995.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ghost particles and Project Poltergeist: Long-ago Lab physicists studied science that haunted them

A neutrino is a tiny, almost massless particle that travels at near light speeds. They were first formed in the early universe and are continually being produced in the nuclear reactions of stars, like the sun, and nuclear reactions on earth. The existence of these “ghost particles” was incredibly difficult to detect, but doing so has helped scientists better understand fundamental principles in physics. Los Alamos Manhattan Project scientist Frederick Reines, along with his colleague Clyde Cowan, is credited with the experimental discovery of the nearly massless elementary particle after his team definitively proved the neutrino’s existence in 1956. Reines received the Nobel Prize in Physics in 1995.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

LightSlingers

LightSlingers are a novel type of directional broadband antenna capable of “slinging” tightly focused wave packets with precision toward a target location. Unlike conventional antennas, they use polarization currents, animated to faster-than-light speeds, as their emission mechanism. Sturdy, small, and versatile, they have the potential to disrupt the telecommunications market. The document serves as documentation/a brochure for the 2022 R&D 100 Award entry.

47 OTHER INSTRUMENTATION↗

A Multi-Layer Phoswich Radioxenon Detection System, Reporting Period 07/01/07 - 09/30/07

During this quarter, the detector manufacturer (Saint-Gobain) delivered one side of the prototype two-channel phoswich detector (XEPHWICH). Once received, our Digital Pulse Processor (DPP1, 12-bit/100 MHz) was employed to capture and digitally process phoswich pulses from laboratory radioactive sources. Our previous pulse shape discrimination algorithm was modified by utilizing three trapezoidal digital filters. This algorithm provides a two-dimensional plot in which the pulse shapes of interest are classified and then can be well identified. The preliminary experimental results will be presented at the 2007 Informal Xenon Monitoring Workshop. The DPP2 (two-channel, 12-bit/ 250 MHz Digital Pulse Processor) is at the prototyping stage. The analog sections have been designed, prototyped and tested. A 6-layer Printed Circuit Board (PCB) was designed, ordered and delivered. The board components were ordered and are now being assembled and examined for proper functionality. In addition, the related FPGA hardware description code (using VHDL) is under development and simulation. Additionally, our researchers have been studying materials regarding wavelet transforms for incorporation into the project. Wavelet transform is an interesting tool for signal processing; one use for our purpose would be to de-noise the detector signal and to express the signal in a few coefficients for signal compression and increased speed. Light capture efficiency modeling and analysis was performed on the XEPHWICH design. Increased understanding of the modeling software was obtained by the discovery of a bug and successful workaround techniques with the DETECT2000 software. Further modeling and plot generation experience was had by the continued use of CERN's ROOT and GEANT4 software packages. Simulations have been performed to compare the output of points versus planes in light capture efficiency. An additional simulation was made with a runtime that was an order-of-magnitude greater than previous simulations, to confirm convergence of the solutions provided by our software methods. We have initiated our investigation into the radon signature expected in our XEPHWICH system. We intend to utilize this signature to confirm earth movement, in the event of an underground nuclear explosion, by continuously monitoring radon levels and noting increases in radon concentration in conjunction with increased levels of radioxenons. The research group is also designing and constructing a fission chamber to be used for the collection of radioxenon gases following neutron bombardment of HEU in the Oregon State University TRIGA reactor. To this point, we have completed milling the aluminum housing and have modeled fission product nuclide production associated with the fissioning of HEU. Additionally, the students have been busy compiling the appropriate information in preparation for irradiation approvals. Using beta spectra of three initial nuclides collected on the prototype phoswich detector, spectral identification by a preliminary neural network was compared to that of solvers of a linear system of equations. Pre-processing in areas such as smoothing and endpoint identification is also being investigated as a means of improving spectral identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Science and Technology Review October/November 2009

This month's issue has the following articles: (1) Award-Winning Collaborations Provide Solutions--Commentary by Steven D. Liedle; (2) Light-Speed Spectral Analysis of a Laser Pulse--An optical device inspects and stops potentially damaging laser pulses; (3) Capturing Waveforms in a Quadrillionth of a Second--The femtoscope, a time microscope, improves the temporal resolution and dynamic range of conventional recording instruments; (4) Gamma-Ray Spectroscopy in the Palm of Your Hand--A miniature gamma-ray spectrometer provides increased resolution at a reduced cost; (5) Building Fusion Targets with Precision Robotics--A robotic system assembles tiny fusion targets with nanometer precision; (6) ROSE: Making Compiler Technology More Accessible--An open-source software infrastructure makes powerful compiler techniques available to all programmers; (7) Restoring Sight to the Blind with an Artificial Retina--A retinal prosthesis could restore vision to people suffering from eye diseases; (8) Eradicating the Aftermath of War--A remotely operated system precisely locates buried land mines; (9) Compact Alignment for Diagnostic Laser Beams--A smaller, less expensive device aligns diagnostic laser beams onto targets; and (10) Securing Radiological Sources in Africa--Livermore and other national laboratories are helping African countries secure their nuclear materials.

42 ENGINEERING↗

Formation of overheated regions and truncated disks around black holes: three-dimensional general relativistic radiation-magnetohydrodynamics simulations

Using three-dimensional general relativistic radiation-magnetohydrodynamics simulations of accretion flows around stellar mass black holes, we report that the relatively cold disk (≳10{sup 7} K) is truncated near the black hole. Hot and less dense regions, of which the gas temperature is ≳10{sup 9} K and more than 10 times higher than the radiation temperature (overheated regions), appear within the truncation radius. The overheated regions also appear above as well as below the disk, sandwiching the cold disk, leading to the effective Compton upscattering. The truncation radius is ∼30r{sub g} for M-dot ∼L{sub Edd}/c{sup 2}, where r{sub g}, M-dot ,L{sub Edd},c are the gravitational radius, mass accretion rate, Eddington luminosity, and light speed, respectively. Our results are consistent with observations of a very high state, whereby the truncated disk is thought to be embedded in the hot rarefied regions. The truncation radius shifts inward to ∼10r{sub g} with increasing mass accretion rate M-dot ∼100L{sub Edd}/c{sup 2}, which is very close to an innermost stable circular orbit. This model corresponds to the slim disk state observed in ultraluminous X-ray sources. Although the overheated regions shrink if the Compton cooling effectively reduces the gas temperature, the sandwich structure does not disappear at the range of M-dot ≲100L{sub Edd}/c{sup 2}. Our simulations also reveal that the gas temperature in the overheated regions depends on black hole spin, which would be due to efficient energy transport from black hole to disks through the Poynting flux, resulting in gas heating.

79 ASTRONOMY AND ASTROPHYSICS↗

General Relativistic Radiation MHD Simulations of Supercritical Accretion onto a Magnetized Neutron Star: Modeling of Ultraluminous X-Ray Pulsars

By performing 2.5-dimensional general relativistic radiation magnetohydrodynamic simulations, we demonstrate supercritical accretion onto a non-rotating, magnetized neutron star, where the magnetic field strength of dipole fields is 10{sup 10} G on the star surface. We found the supercritical accretion flow consists of two parts: the accretion columns and the truncated accretion disk. The supercritical accretion disk, which appears far from the neutron star, is truncated at around ≃3 R {sub *} ( R {sub *} = 10{sup 6} cm is the neutron star radius), where the magnetic pressure via the dipole magnetic fields balances with the radiation pressure of the disks. The angular momentum of the disk around the truncation radius is effectively transported inward through magnetic torque by dipole fields, inducing the spin up of a neutron star. The evaluated spin-up rate, ∼−10{sup −11} s s{sup −1}, is consistent with the recent observations of the ultraluminous X-ray pulsars. Within the truncation radius, the gas falls onto a neutron star along the dipole fields, which results in a formation of accretion columns onto the northern and southern hemispheres. The net accretion rate and the luminosity of the column are ≃66 L {sub Edd}/ c {sup 2} and ≲10 L {sub Edd}, where L {sub Edd} is the Eddington luminosity and c is the light speed. Our simulations support a hypothesis whereby the ultraluminous X-ray pulsars are powered by the supercritical accretion onto the magnetized neutron stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Ball motion and sliding friction in an arched outer race ball bearing

The motion of the ball and sliding friction in an arched outer race ball bearing under thrust loads is determined. Fatigue life evaluations were made. The analysis is applied to a 150 millimeter bore ball bearing. The results indicated that for high speed-light load applications the arched bearing has significant improvement in fatigue life over that of a conventional bearing. An arching of 0.254 mm (0.01 in.) was found to be an optimal. For an arched bearing it was also found that a considerable amount of spinning occurs at the outer race contacts.

Hamrock, B. J.↗

Ball motion and sliding friction in an arched outer race ball bearing

The motion of the ball and sliding friction in an arched outer-race ball bearing under thrust load is determined. Fatigue life evaluations were made. The analysis is applied to a 150 millimeter bore ball bearing. The results indicated that for high speed-light load applications the arched bearing has significant improvement in fatigue life over that of a conventional bearing. An arching of 0.254 mm (0.01 in.) was found to be an optimal. For an arched bearing it was also found that a considerable amount of spinning occurs at the outer race contacts.

Hamrock, B. J.↗