Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL STABILIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Online Monitoring Applications Enabled by Phasor Measurement Units: Technical Assistance to the Power Sectors of Southeast Asia

In this report, an overview of several online applications enabled by PMU measurements is provided. Besides a brief technical background for each application, the report also discusses control room displays and alarming methodologies used by North American organizations, and applicable standards set by the North American Electric Reliability Corporation (NERC). The five applications discussed herein are inertia monitoring, linear state estimation, voltage stability monitoring, small-signal stability monitoring, and forced oscillation monitoring.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Review on Artificial Intelligence (AI) for Stability Assessment: Preprint

Artificial intelligence provides a convenient route for power grid stability assessment. Compared with simulation-based approaches, artificial intelligence can potentially save time on model development and numerical computation in stability assessment. This paper first reviewed existing literature on using artificial intelligence for power grid stability assessment. Then a machine-leaning-based tool is presented and developed to assess power grid transient stability, frequency stability, and small-signal stability. Test results verified the accuracy and effectiveness of the artificial intelligence tool for power grid stability assessment.

artificial intelligence↗

Virtual Self-Excited Induction Generator-Based Grid-Forming Inverter Control for Robust Voltage Regulation Under Nonideal Loading

This paper presents a generator-inspired control methodology for grid-forming (GFM) inverters that deliberately emulates a self-excited induction generator so that the inverter can hold its voltage and frequency under difficult loading and severe terminal disturbances across wide voltage and frequency ranges. The design integrates a Lyapunov energy function-based inner loop to provide high bandwidth and strong disturbance rejection, and it complements this with a passivity-based argument that furnishes a coherent large-signal stability guarantee beyond small-signal limits. Analytical insights are developed via the Krylov-Bogoliubov-Mitropolsky averaging method, which reveals an intrinsic resistive droop characteristic; these closed-form relations both explain the observed dynamics and yield simple, decentralized tuning rules. The methodology is validated on a controller-hardware-in-the-loop platform and exercised in real time across balanced, unbalanced, and nonlinear loads, as well as during parallel operation. Across these scenarios, the inverter maintains balanced three-phase voltages, limits harmonic content, settles quickly with well-damped transients, and remains resilient when multiple units operate in parallel. The contributions are a self-excited-machine-inspired GFM controller with enhanced dynamic performance and robustness, a single stability rationale grounded in passivity, closed-form expressions that guide tuning, and comprehensive hardware-in-the-loop validations demonstrating effectiveness and superiority under challenging operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transient Stability Analysis for Offshore Wind Power Plant Integration Planning Studies - Part II: Long Term Faults

Here, this paper addresses the transient stability (also called large-signal stability) analysis of power systems for offshore wind power plant integration planning studies. In particular, this study develops a comprehensive practical methodology to assess transient stability of power systems, including rotor angle stability, voltage stability, and frequency response for large scale power systems. This methodology considers variability of the offshore wind power plants as well as the type of any faulted system' components present and is applicable to the study of both short term and long term faults. Part I of this research discussed the short term faults whereas as Part II, the present paper, discusses long term faults. This research considers the integration of offshore wind power plants into existing power systems and demonstrates the utility of this methodology through the examination of the specific case of integrating 1,000 MW of offshore wind power into the FirstEnergy/PJM service territory using a realistic model of 63k-bus test system that represents the U.S. Eastern Interconnection.

17 WIND ENERGY↗

MANGO – Modal Analysis for Grid Operation: A Method for Damping Improvement through Operating Point Adjustment

Small signal stability problems are one of the major threats to grid stability and reliability in the U.S. power grid. An undamped mode can cause large-amplitude oscillations and may result in system breakups and large-scale blackouts. There have been several incidents of system-wide oscillations. Of those incidents, the most notable is the August 10, 1996 western system breakup, a result of undamped system-wide oscillations. Significant efforts have been devoted to monitoring system oscillatory behaviors from measurements in the past 20 years. The deployment of phasor measurement units (PMU) provides high-precision, time-synchronized data needed for detecting oscillation modes. Measurement-based modal analysis, also known as ModeMeter, uses real-time phasor measurements to identify system oscillation modes and their damping. Low damping indicates potential system stability issues. Modal analysis has been demonstrated with phasor measurements to have the capability of estimating system modes from both oscillation signals and ambient data. With more and more phasor measurements available and ModeMeter techniques maturing, there is yet a need for methods to bring modal analysis from monitoring to actions. The methods should be able to associate low damping with grid operating conditions, so operators or automated operation schemes can respond when low damping is observed. The work presented in this report aims to develop such a method and establish a Modal Analysis for Grid Operation (MANGO) procedure to aid grid operation decision making to increase inter-area modal damping. The procedure can provide operation suggestions (such as increasing generation or decreasing load) for mitigating inter-area oscillations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transient Stability Analysis for Offshore Wind Power Plant Integration Planning Studies - Part I: Short Term Faults

Power system planning is the process of forecasting load demand and ensuring sufficient generation and reserve capacities over some planning horizon. This process includes investigation of steady-state and dynamic operation of power system of interest. This paper addresses the transient stability (also known as large-signal stability) analysis of power systems for offshore wind power plant integration planning studies. In particular, this study develops a comprehensive practical methodology to assess transient stability of power systems, including rotor angle stability, voltage stability and frequency response for all fault types for large scale power systems. This methodology considers variability of the offshore wind power plants as well as the type of any faulted components present and is applicable to the study of both short term and long term faults, though only short term faults are considered here (long term faults are treated sequentially in a companion paper). Furthermore, this paper considers the integration of offshore wind power plants into existing power systems and demonstrates the utility of this methodology through the examination of the specific case of integrating 1,000MW of offshore wind power into the FirstEnergy/PJM service territory using a realistic model of 63k-bus test system that represents the U.S. Eastern Interconnection.

17 WIND ENERGY↗

Impact of Frequency-Watt Control on the Dynamics of a High DER Penetration Power System

Inverter-coupled generation is slowly displacing synchronous generators in the power system, resulting in reduced system inertia and primary frequency response, which makes the system susceptible to larger frequency deviations. Such deviations may result in load shedding or tripping of inverters, thus reducing the reliability. Frequency-watt control of inverters is an autonomous approach to support grid frequency at a fast timescale by adjusting the inverter output with changes in frequency. This study investigates the dynamics of a power system with a high penetration of distributed PV generation with frequency-watt droop control enabled. A simple aggregated reduced-order two-source model of the O'ahu Island (Hawaii) power system is developed and validated against a full dynamic model, and the small-signal stability of the reduced model is then examined the under various PV penetrations. The impact of frequency-watt parameters on the system frequency dynamics is investigated by observing trajectories of small- signal eigenvalues. The results of the eigenvalue analysis are validated through time-domain simulation. Considerations for frequency-watt parameter selection are discussed.

14 SOLAR ENERGY↗

Low-Frequency Stability Analysis of Inverter-Based Islanded Multiple-Bus AC Microgrids Based on Terminal Characteristics

For system planning of three-phase inverter-based islanded ac microgrids, the low frequency instability issue caused by interactions of inverter droop controllers is a major concern. When internal control information of procured commercial inverters is unknown, impedance-based small-signal stability criteria facilitate prediction of resonances in medium and high frequency ranges, but they usually assume the grid fundamental frequency as constant and thus they are incapable of analyzing the low-frequency oscillation of the fundamental frequency in islanded microgrids. Aiming at solving this issue, this paper proposes two stability analysis methods based on terminal characteristics of inverters and passive connection network including the dynamics of the fundamental frequency for analysis of low-frequency stability in islanded multiple-bus microgrids. Based on the Component Connection Method (CCM) to systematically separate inverters from the passive connection network, a general approach is developed to model the microgrid as a multiple-input-multiple-output (MIMO) negative feedback system in the common system d-q reference frame. By applying the generalized Nyquist stability criterion (GNC) to the return-ratio and return-difference matrices of the MIMO system model, the low-frequency stability related to the fundamental frequency can be analyzed using the measured terminal characteristics of inverters. Finally, analysis and simulation of a 37-bus microgrid verify the effectiveness of the proposed stability analysis methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stability Analysis of Power Systems with High Penetration of State-of-the-Art Inverter Technologies

With the increasing level of inverter-based resources (IBRs) in modern power systems, this paper presents a small-signal stability analysis for power systems comprising synchronous generators (SGs) and IBRs. Four types of inverter controls are considered: two grid-following (GFL) controls, with or without grid support functions; droop-based grid-forming (GFM) controls; and virtual oscillator control-based GFM. We also analyze the impact of STATCOM and synchronous condensers on system stability to assess their role in the energy mix transition. With the small-signal dynamic behavior of the major technologies modeled, this paper provides stringent stability assessments using the IEEE 39-bus benchmark system modified to simulate future power systems. The exhaustive test cases allow for (a) assessing the impacts of different types and controls of generation and supplementary grid assets, as well as system inertia and line impedance on grid stability, and (b) elucidating pathways for the stabilization of IBR-dominated power systems. The analysis also indicates that future power systems can be stabilized with only a fraction of the total generation as voltage sources without SGs or significant system inertia if they are well distributed. This study provides insights into future power system operations with a high level of IBRs that can also be used for planning and operation studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The structure of the ankyrin-binding site of [beta]-spectrin reveals how tandem spectrin-repeats generate unique ligand-binding properties

Spectrin and ankyrin participate in membrane organization, stability, signal transduction, and protein targeting; their interaction is critical for erythrocyte stability. Repeats 14 and 15 of {beta}I-spectrin are crucial for ankyrin recognition, yet the way spectrin binds ankyrin while preserving its repeat structure is unknown. We have solved the crystal structure of the {beta}I-spectrin 14,15 di-repeat unit to 2.1 {angstrom} resolution and found 14 residues critical for ankyrin binding that map to the end of the helix C of repeat 14, the linker region, and the B-C loop of repeat 15. The tilt (64{sup o}) across the 14,15 linker is greater than in any published di-repeat structure, suggesting that the relative positioning of the two repeats is important for ankyrin binding. We propose that a lack of structural constraints on linker and inter-helix loops allows proteins containing spectrin-like di-repeats to evolve diverse but specific ligand-recognition sites without compromising the structure of the repeat unit. The linker regions between repeats are thus critical determinants of both spectrin's flexibility and polyfunctionality. The putative coupling of flexibility and ligand binding suggests a mechanism by which spectrin might participate in mechanosensory regulation.

36 MATERIALS SCIENCE↗

D–Q Impedance Based Stability Analysis and Parameter Design of Three-Phase Inverter-Based AC Power Systems

Small-signal stability is an important concern in three-phase inverter-based ac power systems. The impedance-based approach based on the generalized Nyquist stability criterion (GNC) can analyze the stability related with the medium and high-frequency modes of the systems. However,. the GNC involves the right-half-plane (RHP) pole calculation of return-ratio transfer function matrices, which cannot be avoided for stability analysis of complicated ac power systems. Therefore, it necessitates the detailed internal control information of the inverters, which is not normally available for commercial inverters. To address this issue, this paper introduces the component connection method (CCM) in the frequency domain for stability analysis in the synchronous d-q frame, by proposing a method of deriving the impedance matrix of the connection networks of inverter-based ac power systems. Demonstration on a two-area system and a microgrid shows that: The CCM-enabled approach can avoid the RHP pole calculation of return-ratio matrices and enables the stability analysis by using only the impedances of system components, which could be measured without the need for the internal information. A stability analysis method based on d-q impedances, the CCM, and the determinant-based GNC is also proposed to further simplify the analysis process. Inverter controller parameters can be designed as stability regions in parameter spaces, by repetitively applying the proposed stability analysis method. Simulation and experimental results verify the validity of the proposed stability analysis method and the parameter design approach.

42 ENGINEERING↗

Advanced grid-forming (GFM) inverter controls, modeling and system impact study for inverter dominated grids

Our main goals in this project are to understand: 1) the stability of the power system with very high penetration of PV or other inverter-based resources (IBR), 2) the interactions among IBRs and traditional generators, and 3) the impact of the GFM inverters on bulk power system. To achieve these goals, we took a holistic research and development approach. First, an impedance-based large system modeling and stability analysis tool was developed to aid the large IBR system small-signal stability analysis. Second, consensus-based control and transient overload ride through were developed to control and coordinate multiple GFM inverters in a large system to maintain transient stability during big grid events. Third, high fidelity electromagnetic transient (EMT) IBR models were developed and integrated into a large reduced WECC model to study the system impact from IBRs. Lastly, extensive validation tests of the GFM control which was developed in this project and implemented in two 1MW commercial solar inverters were performed using different validation platforms, e.g., control hardware-in-the-loop (CHIL) platform, power hardware- in-the-loop (PHIL) platform, and a real PV plant.

14 SOLAR ENERGY↗

A Stability Analysis Tool for Bulk Power Systems Using Black-Box Models of Inverter-based Resources

This paper presents a small-signal stability analysis tool for large-scale power systems with high penetration of inverter-based resources (IBRs). Firstly, a network transfer function matrix (NTFM), which represents the information of the system topology, transmission lines, loads, IBRs locations, etc., is derived to model the entire power system network. Secondly, small-signal perturbation method is applied to obtain the sequence impedance/admittance responses of IBRs considering the frequency cross-coupling effects. With the obtained NTFM as well as IBRs' models, a multi-input, multi-output (MIMO) feedback system is constructed, and the generalized Nyquist criterion (GNC)-based stability method is employed to analyze the stability of the entire power system. Different testing cases based on a modified IEEE-14 bus system are leveraged to verify the proposed stability analysis tool.

Sun, Dongsen↗