Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SHUNT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Gate assisted turn-off thyristor with cathode shunts and dynamic gate

A 1,000-V, 200-A gate-assisted turn-off thyristor (GATT) is described, whose design features include an interdigitated shunted cathode, a dynamic gate, a means for optimizing the carrier lifetime level, and a bypass diode. The device physics of gate-assisted turn-off are reviewed. Based on this, improvements in the design are described. It is shown that a prime failure mode can be eliminated and that the gate-assist signal voltage can be substantially decreased by employing a shunted cathode emitter. The test data show excellent turn-on characteristics due to the dynamic gate and the long perimeter of the edge of the main cathode. Turn-off times as short as 3 microsec are obtained. The combination of controlling the carrier lifetime with a precisely controlled and easily variable irradiation dose of high energy electrons with gate assist current provides for simple, precision tailoring of the device characteristics to the intended application.

Schlegel, E. S.↗

Shunt regulation electric power system

A regulated electric power system having load and return bus lines is described. A plurality of solar cells interconnected in a power supplying relationship and having a power shunt tap point electrically spaced from the bus lines is provided. A power dissipator is connected to the shunt tap point and provides for a controllable dissipation of excess energy supplied by the solar cells. A dissipation driver is coupled to the power dissipator and controls its conductance and dissipation and is also connected to the solar cells in a power taping relationship to derive operating power therefrom. An error signal generator is coupled to the load bus and to a reference signal generator to provide an error output signal which is representative of the difference between the electric parameters existing at the load bus and the reference signal generator. An error amplifier is coupled to the error signal generator and the dissipation driver to provide the driver with controlling signals.

Wright, W. H.↗

NASA Redox cell stack shunt current, pumping power, and cell performance tradeoffs

The NASA Redox energy storage system is under active technology development. The hardware undergoing laboratory testing is either 310 sq. cm. or 929 sq. cm. (0.33 sq. ft. or 1.0 sq. ft. per cell active area with up to 40 individual cells connected to make up a modular cell stack. This size of hardware allows rather accurate projections to be made of the shunt power/pump power tradeoffs. The modeling studies that were completed on the system concept are reviewed along with the approach of mapping the performance of Redox cells over a wide range of flow rates and depths of discharge of the Redox solutions. Methods are outlined for estimating the pumping and shunt current losses for any type of cell and stack combination. These methods are applicable to a variety of pumping options that are present with Redox systems. The results show that a fully developed Redox system has acceptable parasitic losses when using a fixed flow rate adequate to meet the worst conditions of current density and depth of discharge. These losses are reduced by about 65 percent if variable flow schedules are used. The exact value of the overall parasitics will depend on the specific system requirements of current density, voltage limits, charge, discharge time, etc.

Hagedorn, N.↗

In vitro flow measurements in ion sputtered hydrocephalus shunts

This paper describes an experimental procedure for accurate measurements of the pressure-drop/flow rate relationship in hydrocephalus shunts. Using a fish-hook arrangement, small flow rates in a perforated ion-sputtered Teflon microtubule were measured in vitro in a pressured system and were correlated with pressure in the system. Results indicate that appropriate drainage rates could be obtained in the physiological range for hydrocephalus shunts.

Cho, Y. I.↗

On-line process analysis innovation: DiComp (tm) shunting dielectric sensor technology

The DiComp Shunting Dielectric Sensor (SDS) is a new patent-pending technology developed under the Small Business Innovation Research Program (SBIR) for NASA's Kennedy Space Center. The incorporation of a shunt electrode into a conventional fringing field dielectric sensor makes the SDS uniquely sensitive to changes in material dielectric properties in the KHz to MHz range which were previously detectable only at GHz measurement frequencies. The initial NASA application of the SDS for Nutrient Delivery Control has demonstrated SDS capabilities for thickness and concentration measurement of Hoagland nutrient solutions. The commercial introduction of DiComp SDS technology for concentration and percent solids measurements in dispersions, emulsions and solutions represents a new technology for process measurements for liquids in a variety of industries.

Davis, Craig R.↗

Options Studied for Managing Space Station Solar Array Electrical Hazards for Sequential Shunt Unit Replacement

The U.S. solar array strings on the International Space Station are connected to a sequential shunt unit (SSU). The job of the SSU is to shunt, or short, the excess current from the solar array, such that just enough current is provided downstream to maintain the 160-V bus voltage while meeting the power load demand and recharging the batteries. Should an SSU fail on-orbit, it would be removed and replaced with the on-orbit spare during an astronaut space walk or extravehicular activity (EVA) (see the photograph). However, removing an SSU during an orbit Sun period with input solar array power connectors fully energized could result in substantial hardware damage and/or safety risk to the EVA astronaut. The open-circuit voltage of cold solar-array strings can exceed 320 V, and warm solar-array strings could feed a short circuit with a total current level exceeding 240 A.

Delleur, Ann M.↗

Contamination of the transformer oil of power transformers and shunting reactors by metal-containing colloidal particles

The results of a measurement of the contamination of the oil in 66 transformers by metal-containing colloidal particles, formed as a result of the interaction of the oil with the structural materials (the copper of the windings, the iron of the tank and core etc.), and also the results of measurements of the optical turbidity of the oil in 136 transformers when they were examined at the Power Engineering Research and Development Center Company are presented. Methods of determining the concentration of copper and iron in transformer oil are considered. The limiting values of the optical turbidity factors, the copper and iron content are determined. These can serve as a basis for taking decisions on whether to replace the silica gel of the filters for continuously purifying the oil of power transformers and the shunting reactors in addition to the standardized oil contamination factors, namely, the dielectric loss tangent and the acidity number of the oil.

36 MATERIALS SCIENCE↗

Computer simulation of magnetization-controlled shunt reactors for calculating electromagnetic transients in power systems

A computer procedure for simulating magnetization-controlled dc shunt reactors is described, which enables the electromagnetic transients in electric power systems to be calculated. It is shown that, by taking technically simple measures in the control system, one can obtain high-speed reactors sufficient for many purposes, and dispense with the use of high-power devices for compensating higher harmonic components.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The effectiveness of using the calculated braking current for longitudinal differential protection of 110 - 750 kV shunt reactors

The use of the function of effective current braking of the longitudinal differential protection of shunt reactors to offset current surges, which enables the sensitivity of differential protection to be increased when there are short circuits with low damage currents, is considered. It is shown that the use of the calculated braking characteristic enables the reliability of offset protection from transients to be increased when the reactor is connected, which is accompanied by the flow of asymmetric currents containing an aperiodic component.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Switching of High-Voltage Cable Lines with Shunt Reactors

The problem of disconnecting high-voltage cable lines with shunt reactors by SF{sub 6} circuit breakers is discussed. In these schemes it is possible to have a significant aperiodic component of the circuit breaker current that can prevent opening of the breaker. The authors propose methods for application to cable transmission lines which they believe will be optimal for ensuring normal disconnects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Limitation of Transient Recovery Voltage When Using Shunt Reactors in 110 – 220 kV Networks

In design practice there often arises the problem of assessing the feasibility of installing shunt reactors (SR) when observing conditions of the occurrence of admissible transient recovery voltages at circuit breaker contacts during switching action. A simplified design methodology for this purpose is proposed for calculating the defining parameters of the SR connection circuit, making it possible to define the feasibility of its use in the analyzed circuit.

42 ENGINEERING↗

Prenatal Ultrasound Analysis of Umbilical‐Portal‐Systemic Venous Shunts Concurrent With Trisomy 21

Objectives A classification termed umbilical‐portal‐systemic venous shunt (UPSVS) for an abnormal umbilical vein (UV), portal vein (PV), and ductus venosus (DV) was proposed recently. According to this classification, there are 3 types of UPSVSs: types I, II, and III. Trisomy 21 associated with UV‐PV‐DV anomalies has been described, but the incidence of trisomy 21 in UPSVS cases, the relationship between UPSVS types and trisomy 21, and the pregnancy outcome are poorly documented. This study aimed to address these issues. Methods All UPSVS cases diagnosed at our department from 2016 to 2019 were retrospectively studied. The English literature describing UV‐PV‐DV anomalies and trisomy 21 from 2000 to 2019 was searched, and the retrieved cases were analyzed. Results Four of 20 UPSVS cases identified by us also had trisomy 21, with 2 type I and 2 type II UPSVSs. Ultrasound markers of Down syndrome were observed in all 4 cases that underwent termination of pregnancy (TOP). The literature search retrieved 12 reports including 279 patients, with 29 also having trisomy 21, giving a pooled trisomy 21 incidence rate of 10.4%. Of the 29 cases, 16 had type I, and 9 had type II, whereas UPSVS types in 4 were undeterminable, and 22 cases underwent TOP. Conclusions There is a high incidence of trisomy 21 in UPSVS cases. Trisomy 21 is associated with a type I or II UPSVS. Most cases with the combined defect underwent TOP. These findings may be used to direct prenatal counseling and management of the combined condition.

Dong, Xiangyi↗

Shear wave elastography prior to transjugular intrahepatic portosystemic shunt may predict the decrease in hepatic vein pressure gradient

Background: Transjugular intrahepatic portosystemic shunt (TIPS) is a procedure used to treat portal hypertension complications. Our aim was to evaluate liver and spleen stiffness measurement (LSM and SSM, respectively) changes using acoustic radiation force impulse imaging (ARFI) in comparison to Child–Pugh scores for predicting hepatic venous pressure gradient (HVPG) decreases after TIPS implantation. Methods: This prospective study included 31 consecutive clinically significant portal hypertension patients with TIPS indication. All patients received LSM and SSM before TIPS, at baseline, 2 days (follow-up 1) and 6 weeks (follow-up 2) post-implantation. HVPG was performed during the TIPS procedure. Results: The mean decrease in HVPG after TIPS was 63%. LSM and SSM decreased significantly between baseline and follow-up 2 (p < 0.001 and p < 0.001, respectively). At baseline, follow-up 1 and follow-up 2, significant correlations were detected between mean SSM and mean HVPG (p = 0.026; p = 0.018; p = 0.002, respectively). HVPG decreased to ≤ 10 mmHg in 61% of patients for which LSM, SSM, and Child–Pugh score were predictors (p = 0.033, p = 0.002 and p = 0.030, respectively). The area under the curve (AUC) for LSM, SSM, and Child–Pugh was 0.88, 0.90, and 0.84, respectively, with close sensitivity and specificity. SSM had the highest diagnostic accuracy for predicting an HVPG decrease to ≤ 10 mmHg in comparison to LSM and Child–Pugh score. Conclusion: Spleen stiffness is superior to liver stiffness and Child–Pugh score as a non-invasive surveillance tool for evaluating patients with clinically significant portal hypertension (HVPG ≥ 10 mmHg) prior to TIPS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Follow-Up After Successful Transjugular Intrahepatic Portosystemic Shunt Placement in a Pediatric Patient with Budd-Chiari Syndrome

Orthotopic liver transplantation is the standard of care in patients with Budd-Chiari syndrome (BCS), and transjugular intrahepatic portosystemic shunt (TIPS) has become an important adjunct procedure while the patient is waiting for a liver. No long-term follow up of TIPS in BCS patients has been published in children. We report successful 10-year follow-up of a child with BCS and iatrogenic TIPS dysfunction caused by oral contraceptive use.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hepatic Veins and Inferior Vena Cava Thrombosis in a Child Treated by Transjugular Intrahepatic Portosystemic Shunt

We report the case of a 9-year-old boy with portal hypertension, due to Budd-Chiari syndrome, and retrohepatic inferior vena cava thrombosis, submitted to a transjugular intrahepatic portosystemic shunt (TIPS) by connecting the suprahepatic segment of the inferior vena cava directly to the portal vein. After 3 months, the withdrawal of anticoagulants promoted the thrombosis of the TIPS. At TIPS revision, thrombosis of the TIPS and the main portal vein and clots at the splenic and the superior mesenteric veins were found. Successful angiography treatment was performed by thrombolysis and balloon angioplasty of a severe stenosis at the distal edge of the stent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗