Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCRUBBERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Processing device with self-scrubbing logic

An apparatus includes a processing unit including a configuration memory and self-scrubber logic coupled to read the configuration memory to detect compromised data stored in the configuration memory. The apparatus also includes a watchdog unit external to the processing unit and coupled to the self-scrubber logic to detect a failure in the self-scrubber logic. The watchdog unit is coupled to the processing unit to selectively reset the processing unit in response to detecting the failure in the self-scrubber logic. The apparatus also includes an external memory external to the processing unit and coupled to send configuration data to the configuration memory in response to a data feed signal outputted by the self-scrubber logic.

97 MATHEMATICS AND COMPUTING↗

Guarantee Testing Results from the Greenidge Mult-Pollutant Control Project

CONSOL Energy Inc. Research & Development (CONSOL R&D) performed flue gas sampling at AES Greenidge to verify the performance of the multi-pollutant control system recently installed by Babcock Power Environmental Inc. (BPEI) on the 107-megawatt (MW) Unit 4 (Boiler 6). The multi-pollutant control system includes combustion modifications and a hybrid selective non-catalytic reduction (SNCR)/induct selective catalytic reduction (SCR) system to reduce NO{sub x} emissions, followed by a Turbosorp{reg_sign} circulating fluidized bed dry scrubber system and baghouse to reduce emissions of SO{sub 2}, SO{sub 3}, HCl, HF, and particulate matter. Mercury removal is provided via the co-benefits afforded by the in-duct SCR, dry scrubber, and baghouse and by injection of activated carbon upstream of the scrubber, as required. Testing was conducted through ports located at the inlet and outlet of the SCR reactor to evaluate the performance of the hybrid NO{sub x} control system, as well as through ports located at the air heater outlet and baghouse outlet or stack to determine pollutant removal efficiencies across the Turbosorp{reg_sign} scrubber and baghouse. Data from the unit's stack continuous emission monitor (CEM) were also used for determining attainment of the performance targets for NO{sub x} emissions and SO{sub 2} removal efficiency.

54 ENVIRONMENTAL SCIENCES↗

Development of a plant-wide dynamic model of an integrated gasification combined cycle (IGCC) plant

In this presentation, development of a plant-wide dynamic model of an advanced Integrated Gasification Combined Cycle (IGCC) plant with CO2 capture will be discussed. The IGCC reference plant generates 640 MWe of net power using Illinois No.6 coal as the feed. The plant includes an entrained, downflow, General Electric Energy (GEE) gasifier with a radiant syngas cooler (RSC), a two-stage water gas shift (WGS) conversion process, and two advanced 'F' class combustion turbines partially integrated with an elevated-pressure air separation unit (ASU). A subcritical steam cycle is considered for heat recovery steam generation. Syngas is selectively cleaned by a SELEXOL acid gas removal (AGR) process. Sulfur is recovered using a two-train Claus unit with tail gas recycle to the AGR. A multistage intercooled compressor is used for compressing CO2 to the pressure required for sequestration. Using Illinois No.6 coal, the reference plant generates 640 MWe of net power. The plant-wide steady-state and dynamic IGCC simulations have been generated using the Aspen Plus{reg_sign} and Aspen Plus Dynamics{reg_sign} process simulators, respectively. The model is generated based on the Case 2 IGCC configuration detailed in the study available in the NETL website1. The GEE gasifier is represented with a restricted equilibrium reactor model where the temperature approach to equilibrium for individual reactions can be modified based on the experimental data. In this radiant-only configuration, the syngas from the Radiant Syngas Cooler (RSC) is quenched in a scrubber. The blackwater from the scrubber bottom is further cleaned in the blackwater treatment plant. The cleaned water is returned back to the scrubber and also used for slurry preparation. The acid gas from the sour water stripper (SWS) is sent to the Claus plant. The syngas from the scrubber passes through a sour shift process. The WGS reactors are modeled as adiabatic plug flow reactors with rigorous kinetics based on the mid-life activity of the shift-catalyst. The SELEXOL unit consists of the H2S and CO2 absorbers that are designed to meet the stringent environmental limits and requirements of other associated units. The model also considers the stripper for recovering H2S that is sent as a feed to a split-flow Claus unit. The tail gas from the Claus unit is recycled to the SELEXOL unit. The cleaned syngas is sent to the GE 7FB gas turbine. This turbine is modeled as per published data in the literature. Diluent N2 is used from the elevated-pressure ASU for reducing the NOx formation. The heat recovery steam generator (HRSG) is modeled by considering generation of high-pressure, intermediate-pressure, and low-pressure steam. All of the vessels, reactors, heat exchangers, and the columns have been sized. The basic IGCC process control structure has been synthesized by standard guidelines and existing practices. The steady-state simulation is solved in sequential-modular mode in Aspen Plus{reg_sign} and consists of more than 300 unit operations, 33 design specs, and 16 calculator blocks. The equation-oriented dynamic simulation consists of more than 100,000 equations solved using a multi-step Gear's integrator in Aspen Plus Dynamics{reg_sign}. The challenges faced in solving the dynamic model and key transient results from this dynamic model will also be discussed.

97 MATHEMATICS AND COMPUTING↗

Immobilization of 99-Technetium (VII) by Fe(II)-Goethite and Limited Reoxidation

During the nuclear waste vitrification process volatilized {sup 99}Tc will be trapped by melter off-gas scrubbers and then washed out into caustic solutions, and plans are currently being contemplated for the disposal of such secondary waste. Solutions containing pertechnetate [{sup 99}Tc(VII)O{sub 4}{sup -}] were mixed with precipitating goethite and dissolved Fe(II) to determine if an iron (oxy)hydroxide-based waste form can reduce Tc(VII) and isolate Tc(IV) from oxygen. The results of these experiments demonstrate that Fe(II) with goethite efficiently catalyzes the reduction of technetium in deionized water and complex solutions that mimic the chemical composition of caustic waste scrubber media. Identification of the phases, goethite + magnetite, was performed using XRD, SEM and TEM methods. Analyses of the Tc-bearing solid products by XAFS indicate that all of the Tc(VII) was reduced to Tc(IV) and that the latter is incorporated into goethite or magnetite as octahedral Tc(IV). Batch dissolution experiments, conducted under ambient oxidizing conditions for more than 180 days, demonstrated a very limited release of Tc to solution (2-7 {micro}g Tc/g solid). Incorporation of Tc(IV) into the goethite lattice thus provides significant advantages for limiting reoxidation and curtailing release of Tc disposed in nuclear waste repositories.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of iron phosphate ceramic waste form to immobilize radioactive waste solution

The objective of this research was to develop an iron phosphate ceramic (IPC) waste form using converter slag obtained as a by-product of the steel industry as a source of iron instead of conventional iron oxide. Both synthetic off-gas scrubber solution containing technetium-99 (or Re as a surrogate) and LiCl-KCl eutectic salt, a final waste solution from pyrochemical processing of spent nuclear fuel, were used as radioactive waste streams. The IPC waste form was characterized for compressive strength, reduction capacity, chemical durability, and contaminant leachability. Compressive strengths of the IPC waste form prepared with different types of waste solutions were 16 MPa and 19 MPa for LiCl-KCl eutectic salt and the off-gas scrubber simulant, respectively, which meet the minimum compressive strength of 3.45 MPa (500 psi) for waste forms to be accepted into the radioactive waste repository. The reduction capacity of converter slag, a main dry ingredient used to prepare the IPC waste form, was 4,136 meq/kg by the Ce(IV) method, which is much higher than those of the conventional Fe oxides used for the IPC waste form and the blast furnace slag materials. Average leachability indexes of Tc, Li, and K for the IPC waste form were higher than 6.0, and the IPC waste form demonstrated stable durability even after 63-day leaching. In addition, the Toxicity Characteristic Leach Procedure measurements of converter slag and the IPC waste form with LiCl-KCl eutectic salt met the universal treatment standard of the leachability limit for metals regulated by the Resource Conservation and Recovery Act. This study confirms the possibility of development of the IPC waste form using converter slag, showing its immobilization capability for radionuclides in both LiCl-KCl eutectic salt and off-gas scrubber solutions with significant cost savings.

converter slag↗

Addendum to Guarantee Testing Results from the Greenidge Multi-Pollutant Control Project: Additiona NH3, NOx, and CO Testing Results

On March 28-30 and May 1-4, 2007, CONSOL Energy Inc. Research & Development (CONSOL R&D) performed flue gas sampling at AES Greenidge to verify the performance of the multi-pollutant control system recently installed by Babcock Power Environmental Inc. (BPEI) on the 107-MW Unit 4 (Boiler 6). The multi-pollutant control system includes combustion modifications and a hybrid selective non-catalytic reduction (SNCR)/in-duct selective catalytic reduction (SCR) system to reduce NO{sub x} emissions, followed by a Turbosorp{reg_sign} circulating fluidized bed dry scrubber system and baghouse to reduce emissions of SO{sub 2}, SO{sub 3}, HCl, HF, and particulate matter. Mercury removal is provided via the co-benefits afforded by the in-duct SCR, dry scrubber, and baghouse and by injection of activated carbon upstream of the scrubber, as required. The testing in March and May demonstrated that the multi-pollutant control system attained its performance targets for NO{sub x} emissions, SO{sub 2} removal efficiency, acid gas (SO{sub 3}, HCl, and HF) removal efficiency, and mercury removal efficiency. However, the ammonia slip measured between the SCR outlet and air heater inlet was consistently greater than the guarantee of 2 ppmvd {at} 3% O{sub 2}. As a result, additional testing was performed on May 30-June 1 and on June 20-21, 2007, in conjunction with tuning of the hybrid NO{sub x} control system by BPEI, in an effort to achieve the performance target for ammonia slip. This additional testing occurred after the installation of a large particle ash (LPA) screen and removal system just above the SCR reactor and a fresh SCR catalyst layer in mid-May. This report describes the results of the additional tests. During the May 30-June 1 sampling period, CONSOL R&D and Clean Air Engineering (CAE) each measured flue gas ammonia concentrations at the air heater inlet, downstream of the in-duct SCR reactor. In addition, CONSOL R&D measured flue gas ammonia concentrations at the economizer outlet, upstream of the SCR reactor, and CAE measured flue gas NO{sub x} and CO concentrations at the sampling grids located at the inlet and outlet of the SCR reactor. During the June 20-21 sampling period, CONSOL R&D measured flue gas ammonia concentrations at the air heater inlet. All ammonia measurements were performed using a modified version of U.S. Environmental Protection Agency (EPA) Conditional Test Method (CTM) 027. The NO{sub x} and CO measurements were performed using U.S. EPA Methods 7E and 10, respectively.

54 ENVIRONMENTAL SCIENCES↗

Greenidge Multi-Pollutant Control Project

The Greenidge Multi-Pollutant Control Project was conducted as part of the U.S. Department of Energy's Power Plant Improvement Initiative to demonstrate an innovative combination of air pollution control technologies that can cost-effectively reduce emissions of SO{sub 2}, NO{sub x}, Hg, acid gases (SO{sub 3}, HCl, and HF), and particulate matter from smaller coal-fired electric generating units (EGUs). There are about 400 units in the United States with capacities of 50-300 MW that currently are not equipped with selective catalytic reduction (SCR), flue gas desulfurization (FGD), or mercury control systems. Many of these units, which collectively represent more than 55 GW of installed capacity, are difficult to retrofit for deep emission reductions because of space constraints and unfavorable economies of scale, making them increasingly vulnerable to retirement or fuel switching in the face of progressively more stringent environmental regulations. The Greenidge Project sought to confirm the commercial readiness of an emissions control system that is specifically designed to meet the environmental compliance requirements of these smaller coal-fired EGUs by offering a combination of deep emission reductions, low capital costs, small space requirements, applicability to high-sulfur coals, mechanical simplicity, and operational flexibility. The multi-pollutant control system includes a NO{sub x}OUT CASCADE{reg_sign} hybrid selective non-catalytic reduction (SNCR)/in-duct SCR system for NO{sub x} control and a Turbosorp{reg_sign} circulating fluidized bed dry scrubbing system (with a new baghouse) for SO{sub 2}, SO{sub 3}, HCl, HF, and particulate matter control. Mercury removal is provided as a co-benefit of the in-duct SCR, dry scrubber, and baghouse, and by injection of activated carbon upstream of the scrubber, if required. The multi-pollutant control system was installed and tested on the 107-MW{sub e}, 1953-vintage AES Greenidge Unit 4 by a team including CONSOL Energy Inc. as prime contractor, AES Greenidge LLC as host site owner, and Babcock Power Environmental Inc. as engineering, procurement, and construction contractor. About 44% of the funding for the project was provided by the U.S. Department of Energy, through its National Energy Technology Laboratory, and the remaining 56% was provided by AES Greenidge. Project goals included reducing high-load NO{sub x} emissions to {le} 0.10 lb/mmBtu; reducing SO{sub 2}, SO{sub 3}, HCl, and HF emissions by at least 95%; and reducing Hg emissions by at least 90% while the unit fired 2-4% sulfur eastern U.S. bituminous coal and co-fired up to 10% biomass. This report details the final results from the project. The multi-pollutant control system was constructed in 2006, with a total plant cost of $349/kW and a footprint of 0.4 acre - both substantially less than would have been required to retrofit AES Greenidge Unit 4 with a conventional SCR and wet scrubber. Start-up of the multi-pollutant control system was completed in March 2007, and the performance of the system was then evaluated over an approximately 18-month period of commercial operation. Guarantee tests conducted in March-June 2007 demonstrated attainment of all of the emission reduction goals listed above. Additional tests completed throughout the performance evaluation period showed 96% SO{sub 2} removal, 98% mercury removal (with no activated carbon injection), 95% SO{sub 3} removal, and 97% HCl removal during longer-term operation. Greater than 95% SO{sub 2} removal efficiency was observed even when the unit fired high-sulfur coals containing up to 4.8 lb SO{sub 2}/mmBtu. Particulate matter emissions were reduced by more than 98% relative to the emission rate observed prior to installation of the technology. The performance of the hybrid SNCR/SCR system was affected by problems with large particle ash, ammonia slip, and nonideal combustion characteristics, and high-load NO{sub x} emissions averaged 0.14 lb/mmBtu during long-term operation. Nevertheless, the system has reduced the unit's overall NO{sub x} emissions by 52% on a lb/mmBtu basis. The commercial viability of the multi-pollutant control system was demonstrated at AES Greenidge Unit 4. The system, which remains in service after the conclusion of the project, has enabled the unit to satisfy its permit requirements while continuing to operate profitably. As a result of the success at AES Greenidge Unit 4, three additional deployments of the Turbosorp{reg_sign} technology had been announced by the end of the project.

01 COAL, LIGNITE, AND PEAT↗

Comparing materials used in mist eliminators

Wet flue gas desulfurization (FGD) systems, or wet scrubbers, are notoriously capital - and maintenance-intensive. Mist eliminators are an integral part of most wet FGD systems. These are available in a variety of materials - polypropylene, fiberglass reinforced polymer (FRP), polysulfone and stainless steel. The article discusses the material properties, performance attributes and relative cost differences associated with each of these four materials. It describes the common problems with mist eliminators - fouling and corrosion. These can be minimised by routine cleaning and use of chemical additives to prevent deposition. An analysis was carried out to compare the four materials at APS Cholla power plant. As a result the facility is retrofitting its remaining wet scrubber towers in Unit 2 with mist eliminators constructed from polysulfone as each of the current ones of the existing polypropylene needs replacing. Polysulfone is cheaper to clean and components require replacing less frequently than polypropylene. Switching from stainless steel to polypropylene has proved advantageous on 22 wet scrubbers operated by PPL Montana. 5 figs. 2 tabs.

01 COAL, LIGNITE, AND PEAT↗

Benefits of evaporating FGD purge water

In the US and the European Union, scrubbers are installed on all new coal-fired power plants because their technology is considered the best available for removing SO{sub 2}. A zero liquid discharge (ZLD) system is the best technology for treating wet scrubber wastewate. With the future promising stricter limits on power plants' water use, ZLD systems that concentrate scrubber purge streams are sure to become as common as ZLD cooling tower blowdonw systems. 7 figs.

01 COAL, LIGNITE, AND PEAT↗

Greenridge Multi-Pollutant Control Project Preliminary Public Design Report

The Greenidge Multi-Pollutant Control Project is being conducted as part of the U.S. Department of Energy's Power Plant Improvement Initiative to demonstrate an innovative combination of air pollution control technologies that can cost-effectively reduce emissions of SO{sub 2}, NO{sub x}, Hg, acid gases (SO{sub 3}, HCl, and HF), and particulate matter from smaller coal-fired electrical generating units (EGUs). The multi-pollutant control system includes a hybrid selective non-catalytic reduction (SNCR)/in-duct selective catalytic reduction (SCR) system to reduce NOx emissions by {ge}60%, followed by a Turbosorp{reg_sign} circulating fluidized bed dry scrubber system to reduce emissions of SO{sub 2}, SO{sub 3}, HCl, and HF by {ge}95%. Mercury removal of {ge}90% is also targeted via the co-benefits afforded by the in-duct SCR, dry scrubber, and baghouse and by injection of activated carbon upstream of the scrubber, as required. The technology is particularly well suited, because of its relatively low capital and maintenance costs and small space requirements, to meet the needs of coal-fired units with capacities of 50-300 MWe. There are about 440 such units in the United States that currently are not equipped with SCR, flue gas desulfurization (FGD), or mercury control systems. These smaller units are a valuable part of the nation's energy infrastructure, constituting about 60 GW of installed capacity. However, with the onset of the Clean Air Interstate Rule, Clean Air Mercury Rule, and various state environmental actions requiring deep reductions in emissions of SO{sub 2}, NO{sub x}, and mercury, the continued operation of these units increasingly depends upon the ability to identify viable air pollution control retrofit options for them. The large capital costs and sizable space requirements associated with conventional technologies such as SCR and wet FGD make these technologies unattractive for many smaller units. The Greenidge Project aims to confirm the commercial readiness of an emissions control system that is specifically designed to meet the environmental compliance requirements of these smaller coal-fired EGUs. The multi-pollutant control system is being installed and tested on the AES Greenidge Unit 4 (Boiler 6) by a team including CONSOL Energy Inc. as prime contractor, AES Greenidge LLC as host site owner, and Babcock Power Environmental Inc. as engineering, procurement, and construction contractor. All funding for the project is being provided by the U.S. Department of Energy, through its National Energy Technology Laboratory, and by AES Greenidge. AES Greenidge Unit 4 is a 107 MW{sub e} (net), 1950s vintage, tangentially-fired, reheat unit that is representative of many of the 440 smaller coal-fired units identified above. Following design and construction, the multi-pollutant control system will be demonstrated over an approximately 20-month period while the unit fires 2-4% sulfur eastern U.S. bituminous coal and co-fires up to 10% biomass. This Preliminary Public Design Report is the first in a series of two reports describing the design of the multi-pollutant control facility that is being demonstrated at AES Greenidge. Its purpose is to consolidate for public use all available nonproprietary design information on the Greenidge Multi-Pollutant Control Project. As such, the report includes a discussion of the process concept, design objectives, design considerations, and uncertainties associated with the multi-pollutant control system and also summarizes the design of major process components and balance of plant considerations for the AES Greenidge Unit 4 installation. The Final Public Design Report, the second report in the series, will update this Preliminary Public Design Report to reflect the final, as-built design of the facility and to incorporate data on capital costs and projected operating costs.

01 COAL, LIGNITE, AND PEAT↗

Minimize Solvent Oxidation with NO X Pre-Scrubbing

A novel method to remove nitrogen dioxide (NO 2 ) from the flue gas of coal-fired power plants with CO 2 capture was further developed for commercial implementation. The technology leverages the equipment and chemistry in an existing (sulfur dioxide) SO 2 polishing scrubber upstream of the main CO 2 capture unit to remove the NO 2 , preventing degradation of the CO 2 capture solvent and formation of nitrosamines (environmental hazards). The research in this report focuses on further evaluation of the chemical additives and operating conditions associated with the NO 2 removal process to define conditions for commercial scale testing and deployment. Experimental work systematically evaluated a series of potential additives to minimize the oxidation of sulfite in a representative SO 2 pre-scrubber solution (sulfite, in turn, absorbs NO 2 ). The additive combinations and concentrations were varied alongside important process conditions such as temperature, oxygen concentration, and metals present in solution to mimic the conditions expected in a commercial system. Important results of the parametric experimental work include identifying a new, potent sulfite oxidation inhibitor, revealing the importance of combining inhibitors with metal chelating agents, validation of a low-cost additive process, and development of a new semi-empirical model to represent mechanisms associated with sulfite oxidation. In addition, the experimental work reveled the impact of operating at higher temperatures (representative of a field test unit), which will guide the selection and concertation of additives as well. Engineering analysis found that waste solutions from the pre-scrubber with NO 2 additives may potentially be integrated with existing processes on site (e.g., flue gas desulfurization unit). In addition, techno-economic analysis identified potential net savings as large as $1.30/tonne CO 2 captured and quantified the potential benefit of low cost additive options actively being pursued by the development team. Finally, the experimental results and engineering analysis supported the development of a detailed field testing plan and protocol to evaluate the technology at near-commercial scale. The field test preparation included development of procedures to introduce chemical additives to an existing SO 2 polishing unit and identification of representative flue gas conditions based on a review of existing plants. These activities will have direct bearing on operation and design of commercial units.

20 FOSSIL-FUELED POWER PLANTS↗

Review of Experimental Decontamination Factors (DF) of Iodine in the Pilot-Scale Law Melter Off-Gas Systems

The Low Activity Waste (LAW) melters at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) will convert low-activity tank wastes containing high concentrations of sodium salts into glass for onsite disposal. Much of the airborne particulates during the calcination/fusion of the feed solids will be removed by condensation and scrubbing of the melter exhaust in the Submerged Bed Scrubber (SBS) and Wet Electrostatic Precipitator (WESP)of the primary off-gas treatment system. The gases exiting the WESP enter a secondary off-gas treatment system, which includes a High-Efficiency Particulate Air (HEPA) filter, an activated carbon absorber, a Thermal Catalytic Oxidizer (TCO), a Selective Catalytic Reduction (SCR) unit, a caustic scrubber, and an exhauster. Much of the volatile organics and NOx will be removed in the TCO and SCR, respectively. Under WTP Direct Feed LAW (DFLAW) configuration, the liquid effluents from the SBS and WESP will be collected and evaporated under vacuum with the evaporator concentrate recycled back to the LAW melter, while the evaporator condensate will be merged with the caustic scrubber solution and sent to the Effluent Treatment Facility (ETF).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mechanisms Engineering Test Loop (METL) Operations and Testing Report (FY2022)

This report documents the operations, testing, maintenance, and improvements that were performed at the Mechanisms Engineering Test Loop (METL) during FY2022. The METL facility had a very successful fourth year of operations and went through some new experiences such as taking the facility from its frozen state in October 2021 and thawing the facility and also recovering from an oxide plug in one of the cold trap lines. After the facility was fully thawed, the METL staff maintained the facility in a continuous molten state – either flowing sodium or a static flow condition. METL facility continued supporting the Gear Test Assembly (GTA) testing and hosted its first 28” test vessel experiment, called the Thermal Hydraulic Experimental Test Article (THETA) which was inserted into Test Vessel 4. Work to accommodate two additional experiments, a gripper test article (GrTA) and a flow sensor test article (F-STAr) continued as they are expected to make their debut in FY2023. In addition, the steam piping for the B308 scrubber unit was replaced with stainless steel piping and controls and new parts for the scrubber were purchased – such as a new pump, new storage tank, and new blower and motor. These components will ultimately replace the existing scrubber components when those 1970’s era require replacement.

42 ENGINEERING↗

Iodine Speciation Effects in LAW Feeds

Tests were conducted on a DM10 vitrification system with prototypical off-gas treatment system, which includes an SBS, WESP, and evaporator based on the design of the evaporator to be installed at the WTP for concentration of the liquid effluents. This allowed determination of the partitioning and speciation of iodine between the melter and the off gas system components, including liquid effluents from the SBS and WESP as well as in the evaporator condensate and concentrate. Evaporator testing was decoupled from melter testing to permit filtration and pH adjustments of process solutions prior to evaporation. In addition, a slip stream was pulled from the exhaust downstream of the WESP and High-Efficiency Particulate Air (HEPA) filters and passed through a caustic scrubber simulating the WTP caustic scrubber to assess iodine partitioning to the caustic scrubber liquid effluent. The tests were conducted using simulated Hanford LAW from tank AP-107, which is the planned first feed for Direct Feed LAW (DFLAW) operations, at a nominal feed concentration of 5.6 molar Na over about 120 hours of testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of a mercury speciation technique for flue gas desulfurization materials

Most of the synthetic gypsum generated from wet flue gas desulfurization (FGD) scrubbers is currently being used for wallboard production. Because oxidized mercury is readily captured by the wet FGD scrubber, and coal-fired power plants equipped with wet scrubbers desire to benefit from the partial mercury control that these systems provide, some mercury is likely to be bound in with the FGD gypsum and wallboard. In this study, the feasibility of identifying mercury species in the FGD gypsum and wallboard samples was investigated using a large sample size thermal desorption method and samples from power plants in Pennsylvania. Potential candidates of pure mercury standards including mercuric chloride, mercurous chloride, mercury oxide, mercury sulfide, and mercuric sulfate were analyzed to compare their results with those obtained from FGD gypsum and dry wallboard samples. Although any of the thermal evolutionary curves obtained from these pure mercury standards did not exactly match with those of the FGD gypsum and wallboard samples, it was identified that Hg{sub 2}Cl{sub 2} and HgCl{sub 2} could be candidates. An additional chlorine analysis from the gypsum and wallboard samples indicated that the chlorine concentrations were approximately 2 orders of magnitude higher than the mercury concentrations, suggesting possible chlorine association with mercury. 21 refs., 5 figs., 3 tabs.

01 COAL, LIGNITE, AND PEAT↗

Measurements of dimethyl sulfide and H2S over the western North Atlantic and the tropical Atlantic

Airborne measurements of DMS and H2S were made off the east coast of the United States and over the tropical Atlantic off Brazil. Samples were collected through a fluorinated ethylene propylene Teflon inlet manifold. Dimethyl sulfide (DMS) was preconcentrated onto gold wool and analyzed by gas chromatography/flame photometric detection. H2S was collected on AgNO3-impregnated filters and determined by fluorescence quenching. Use of a new scrubber material (cotton) to remove negative interference on DMS measurements was investigated. Comparison with a Na2CO3/Anakrom scrubber gave good overall agreement. Only under extreme conditions, e.g., on flight 9 (continental air mass, low humidity, high O3, and low DMS values) did Na2CO3 show noticeable loss of DMS compared to cotton. On most flights, especially in marine air masses with high humidity and relatively low O3, the results from both scrubbers agreed well with each other and with other instruments used during the intercalibration. Off the U.S. East Coast, DMS levels showed strong dependence on air mass origin with high values (up to 83 ppt) in marine tropical air masses and low values (10-20 ppt) in continental and polar air. Over the tropical Atlantic, DMS ranged over 20-100 ppt in the mixed layer. Nighttime values were a factor of 1.6-2.3 higher than daytime levels. DMS decreased with altitude to less than 1 ppt at 4000 m. H2S in the mixed layer off the U.S. East Coast ranged from 10 to 200 ppt. Significant influence from terrestrial and pollution sources was evident. H2S in air masses originating over the eastern seaboard was much higher than in continental polar air or over the remote tropical continents. In contrast, over the tropical Atlantic, concentrations were very low (5-10 ppt), typical of truly marine air. Night/day ratios were about 1.4. No significant geographical variability was seen in H2S levels over the tropical Atlantic. The correlation of atmospheric Rn-222 and H2S was significant, with both being higher off the U.S. East Coast than over the tropical Atlantic.

Andreae, T. W.↗

System and method for production of ultra-pure hydrogen from biomass

The disclosure provides a system and method for synthesizing ultra-pure hydrogen from biomass waste. The present invention comprises a gasifier, an oils and tars filter, a steam generator, a water gas shift reactor ("WGS"), a heat-exchange two-phase water separator, a scrubber, a hydrogen separator, and fluid conduits in fluid communication with the various system components, which together convert hydrocarbon-based biomass, e.g., woodchips, into ultra-pure hydrogen gas. Fluid conduits connect the gasifier and the steam generator, separately, to the WGS, the WGS to the two-phase separator, the two-phase separator to the scrubber, and the scrubber to the hydrogen separator, which further comprises an outlet port through which hydrogen gas may flow free of carbon monoxide. The hydrogen may flow to a device that utilizes hydrogen to generate energy, such as a hydrogen fuel cell or to an internal combustion engine.

Tawfik, Hazem↗

Speciation, Characterization and Mobility of As, Se and Hg in Flue Gas Desulphurization Residues

Flue gas from coal combustion contains significant amounts of volatile toxic trace elements such as arsenic (As), selenium (Se), and mercury (Hg). The capture of these elements in the flue gas desulphurization (FGD) scrubber unit has resulted in generation of a metal-laden residue. With increasing reuse of the FGD residues in beneficial applications, it is important to determine metal speciation and mobility to understand the environmental impact of its reuse. In this paper, we report the solid phase speciation of As, Se, and Hg in FGD residues using X-ray absorption spectroscopy (XAS), X-ray fluorescence spectroscopy (XRF), and sequential chemical extraction (SCE) techniques. The SCE results combined with XRF data indicated a strong possibility of As association with iron oxides, whereas Se was distributed among all geochemical phases. Hg appeared to be mainly distributed in the strong-complexed phase. XRF images also suggested a strong association of Hg with Fe oxide materials within FGD residues. XAS analysis indicated that As existed in its oxidized state (As(V)), whereas Se and Hg was observed in primarily reduced states as selenite (Se(IV)) and Hg(I), respectively. The results from the SCE and variable pH leaching tests indicated that the labile fractions of As, Se, and Hg were fairly low and thus suggestive of their stability in the FGD residues. However, the presence of a fine fraction enriched in metal content in the FGD residue suggested that size fractionation is important in assessing the environmental risks associated with their reuse.

01 COAL, LIGNITE, AND PEAT↗