Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCINTILLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Optimizing ZnS/6LiF scintillators for wavelength-shifting-fiber neutron detectors

In this paper we compare the performance of grooved and flat ZnS/6LiF scintillators in a wavelength shifting-fiber (WLSF) detector. Flat ZnS/6LiF scintillators with the thickness L=0.2-0.8 mm were characterized using photon counting and pulse-height analysis and compared to a grooved scintillator of approximately 0.8 mm thick. While a grooved scintillator considerably increases the apparent thickness of the scintillator to neutrons for a given coating thickness, we find that the flat scintillators perform better than the grooved scintillators in terms of both light yield and neutron detection efficiency. The flat 0.8-mm-thick scintillator has the highest light output, and it is 52% higher compared with a grooved scintillator of same thickness. The lower light output of the grooved scintillator as compared to the flat scintillator is consistent with the greater scintillator-WLSF separation and the much larger average emission angle of the grooved scintillator. We also find that the average light cone width, or photon travel-length as measured using time-of-flight powder diffraction of diamond and vanadium, decreases with increasing L in the range of L=0.6-0.8 mm. This result contrasts with the traditional Swank diffusion model for micro-composite scintillators, and could be explained by a decrease in photon diffusion-coefficient or an increase in micro-particle content in the flat scintillator matrix for the thicker scintillators.

Crow, Lowell↗

Study of Plastic Scintillator Properties for Radioactive Sources Dosimetry - Paper 108

Plastic scintillator is a simple material which has the density close to that of human soft tissue (1.06 g/cm{sup 3}). Its energy response is close to that of human soft tissue and it is relatively energy independent. This prospect provide a desired characteristics in measuring dose by plastic scintillator either for radiation monitoring or personal dosimeter. Generally the energy calibration of organic scintillator will be done by using gamma ray sources. The positions of Compton edge in pulse height spectra, which have known energy values will be identified. However the Compton edge normally is very broad and difficult to determine the point corresponding to that particular Compton electron energies. Many researchers used several fitting functions and Monte Carlo simulations to determine the position of Compton edge. For example, Proctor and Wellman (2012) used a straight line fit to the linear part of Compton edge and extrapolated to zero count. While L. Swiderski et al. used a method based on a back-scattered coincidence measurement to measure in a wide energy range the position of Compton edge in organic scintillators. For a simple and quick approach of calibration, we used a Gauss-error function to fit the Compton edge region of interest by assumed that the location of maximum energy of Compton electrons is half-height of the Compton maximum (CM). The reasons is because the CM position could be determined easily from the spectra throughout wide energy range. Interpreting gamma dose rates from accumulated plastic scintillation detector spectra is often a complex task because the probability of a full energy deposition event in the detector is often negligible. Despite no full energy peaks in plastic scintillator spectra, several attempts have been made by the other researchers to obtain the dose from the energy distribution spectra of gamma radiation. For example, Proctor and Wellman used the modified spectrum dose index (SDI) to calculate the exposure rates by multiplying the energy corresponding to its channel and all products are summed before multiply by a calibration constant to yield an exposure rate. While Lobdell and Hertel calculated dose using a response matrix based on spectral unfolding technique. From these points of view, we have made an attempt to correlate the counts obtained in scintillator with absorbed dose or ambient dose equivalent. We aimed to calibrate the plastic scintillator energy deposition for dose, by correlate the counts obtained with a particular value of dose. By designed the scintillator to measure at 1 cm tissue depth might be helpful to be used as radiation monitoring or personal dosimeter since the energy response of plastic scintillator is relatively energy independent compared to that of inorganic scintillators. The energy calibration proposed from simple fitting approach had been verified with calculated spectra. This might be considered as a practical approach for technician or radiation workers with sufficient accuracy. The linear behavior of counts per absorbed dose give promising to calibrate scintillator energy deposition to read dose (equivalent dose or absorbed dose) for photons. Thus the scintillator could provide both the energy and dose response simultaneously, which may important in some radiation field of measurements. Currently the scintillator is able to give dose rate value for gamma sources of Cs-137 and Mn-54. The number of counts per unit absorbed dose would likely to vary somewhat with photon energy, although the plastic scintillator should have a tissue dose response that is relatively energy independent. Further analysis will be done on conversion factor parameters so that it could be used in such situations where the radiation field is complex or unknown. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing energy dependence and count rate performance of a dual scintillator fiber-optic detector for computed tomography

Purpose: Kilovoltage (kV) x-rays pose a significant challenge for radiation dosimetry. In the kV energy range, even small differences in material composition can result in significant variations in the absorbed energy between soft tissue and the detector. In addition, the use of electronic systems in light detection has demonstrated measurement losses at high photon fluence rates incident to the detector. This study investigated the feasibility of using a novel dual scintillator detector and whether its response to changes in beam energy from scatter and hardening is readily quantified. The detector incorporates a tissue-equivalent plastic scintillator and a gadolinium oxysulfide scintillator, which has a higher sensitivity to scatter x-rays. Methods: The detector was constructed by coupling two scintillators: (1) small cylindrical plastic scintillator, 500 μm in diameter and 2 mm in length, and (2) 100 micron sheet of gadolinium oxysulfide 500 μm in diameter, each to a 2 m long optical fiber, which acts as a light guide to transmit scintillation photons from the sensitive element to a photomultiplier tube. Count rate linearity data were obtained from a wide range of exposure rates delivered from a radiological x-ray tube by adjusting the tube current. The data were fitted to a nonparalyzable dead time model to characterize the time response. The true counting rate was related to the reference free air dose air rate measured with a 0.6 cm{sup 3} Radcal{sup ®} thimble chamber as described in AAPM Report No. 111. Secondary electron and photon spectra were evaluated using Monte Carlo techniques to analyze ionization quenching and photon energy-absorption characteristics from free-in-air and in phantom measurements. The depth/energy dependence of the detector was characterized using a computed tomography dose index QA phantom consisting of nested adult head and body segments. The phantom provided up to 32 cm of acrylic with a compatible 0.6 cm{sup 3} calibrated ionization chamber to measure the reference air kerma. Results: Each detector exhibited counting losses of 5% when irradiated at a dose rate of 26.3 mGy/s (Gadolinium) and 324.3 mGy/s (plastic). The dead time of the gadolinium oxysulfide detector was determined to be 48 ns, while the dead time of the plastic scintillating detector was unable to accurately be calculated due to poor counting statistics from low detected count rates. Noticeable depth/energy dependence was observed for the plastic scintillator for depths greater than 16 cm of acrylic that was not present for measurements using the gadolinium oxysulfide scintillator, leading us to believe that quenching may play a larger role in the depth dependence of the plastic scintillator than the incident x-ray energy spectrum. When properly corrected for dead time effects, the energy response of the gadolinium oxysulfide scintillator is consistent with the plastic scintillator. Using the integrated dual detector method was superior to each detector individually as the depth-dependent measure of dose was correctable to less than 8% between 100 and 135 kV. Conclusions: The dual scintillator fiber-optic detector accommodates a methodology for energy dependent corrections of the plastic scintillator, improving the overall accuracy of the dosimeter across the range of diagnostic energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-239: Evaluation of Plastic Scintillator Light Output for Various Lead Doping Concentrations: Towards LET Detection

Purpose: This work seeks to develop a beam quality meter using multiple differently doped plastic scintillators that are thus intrinsically beam-quality dependent. Plastic scintillators spontaneously emit visible light upon irradiation; the amount of light produced is dependent on stopping power (closely related to LET) according to Birks’ law. Doping plastic scintillators can be used to tune their sensitivity to specific LET ranges. Methods: GEANT4.10.1 Monte Carlo (MC) was used to evaluate the response of various scintillator dopant combinations. MC radiation transport and scintillator light response were validated against previously published literature. Current work involves evaluating detector response experimentally; to that end, a detector prototype with interchangeable scintillator housing was constructed. Measurement set-up guides light emitted by the scintillator to a photomultiplier tube via a glass taper junction coupled to an optical fiber. The resulting signal is measured by an electrometer, and normalized to dose readout from a diode. Measurements have been done using clinical electron and orthovoltage beams. MC response (simulated scintillator light normalized to dose scored inside the scintillating volume) was evaluated for four different LET radiations for an undoped and 1%Pb doped scintillator (σ=0.85%). Simulated incident electrons included: 0.05, 0.1, 0.2, 6, 12, and 18 MeV; these energies correspond to a range of stopping power (related to LET) values ranging from 1.824 to 11.09 MeVcm{sup 2}g{sup −1} (SCOL from NIST-ESTAR). Results: Initial MC results show a distinct divergence in scintillator response as LET increases. The response for undoped plastic scintillator indicated a 35.0% increase in signal when going from 18 MeV (low LET) to 0.05 MeV (high LET) while 1%-Pb doped scintillator indicated a 100.9% increase. Conclusion: After validating MC against measurement, simulations will be used to test various concentrations (2%, 4%, 6%) of different high-Z material dopants (W, Mo) to optimize the scintillator types for the beam quality meter. NSERC Discovery Grant RGPIN-435608.

60 APPLIED LIFE SCIENCES↗

Fabrication of Low-Cost Large-Volume Ceramic A 2 HfX 6 (A= Cs or Tl, X = Cl, Br, or I) Scintillators for Gamma Ray Detection (SBIR Phase I Final Technical Report)

Scintillator crystals play an important role in the radiation detection field. Widespread use of scintillators as gamma-ray detectors is largely generated by their extensive availability and tunable properties, such high light output, high stopping power (Z eff ), fast decay time, and good proportionality. Additionally, the cost for manufacturing a scintillation detector like NaI:Tl is usually considerably lower than the cost for manufacturing a semiconductor detector like CdZnTe. Because there is no such thing as an ideal scintillation material, an application requiring certain detection characteristics may incorporate a scintillator tailored to its specific properties. The vast variety of applications and requirements necessitates more research into new scintillation materials and/or better methods of producing existing materials.The goal of this project was to grow low cost and environmentally stable inorganic transparent ceramic scintillators with excellent gamma ray resolution, excellent energy proportionality, excellent detection efficiency due to high density (>5 g/cm 3 ) and very high Z eff (55-80), and good light yields (>40,000 ph/MeV). In Phase I Xtallized Intelligence, Inc. (XI, Inc) developed a novel ceramic fabrication technique to produce low cost and environmentally stable highly efficient inorganic transparent ceramic scintillators of various dimensions. XI, Inc., collaborating with Fisk University (Fisk), investigated the scintillation properties of these new ceramic scintillators and compared them to in their single crystal counterparts. The results of this Phase I project show that successful production of high-quality inorganic halide ceramic scintillators Cs 2 HfCl 6 (CHC) and Tl 2 HfCl 6 (THC). Both ceramic CHC and THC scintillators have achieved good performance close to the performance of their single crystal counterparts. Fabricating these inorganic ceramic scintillators mitigate many issues encountered during conventional bulk crystal growth by melt methods. Additional benefits of the ceramic fabrication technique include high production yield, low production cost, fast production time, and no material waste Inorganic transparent ceramic scintillators produced in this project will enhance cost effectiveness at the instrument level based on low projected cost of the proposed compounds, as much smaller crystal sizes would be required to achieve similar efficiency as current radioisotope identification devices (RIID’s) used in homeland security applications as well as spectrometers in high energy physics applications.

36 MATERIALS SCIENCE↗

TH-C-19A-11: Toward An Optimized Multi-Point Scintillation Detector

Purpose: The purpose of this work is to characterize a 2-points mPSDs' optical chain using a spectral analysis to help selecting the optimal components for the detector. Methods: Twenty different 2-points mPSD combinations were built using 4 plastic scintillators (BCF10, BCF12, BCF60, BC430; St-Gobain) and quantum dots (QDs). The scintillator is said to be proximal when near the photodetector, and distal otherwise. A 15m optical fiber (ESKA GH-4001) was coupled to the scintillating component and connected to a spectrometer (Shamrock, Andor and QEPro, OceanOptics). These scintillation components were irradiated at 125kVp; a spectrum for each scintillator was obtained by irradiation of individual scintillator and shielding the second component, thus talking into account light propagation in all components and interfaces. The combined total spectrum was also acquired and involved simultaneous irradiation of the two scintillators for each possible combination. The shape and intensity were characterized. Results: QDs in proximal position absorb almost all the light signal from distal plastic scintillators and emit in its own emission wavelength, with 100% of the signal in the QD range (625–700nm) for the combination BCF12/QD. However, discrimination is possible when QD is in distal position in combination with blue scintillators, total signal being 73% in the blue range (400-550nm) and 27% in QD range. Similar results are obtained with the orange scintillator (BC430). For optimal signal intensity, BCF12 should always be in proximal position, e.g. having 50% more intensity when coupled with BCF60 in distal position (BCF12/BCF60) compared to the BCF60/BCF12 combination. Conclusion: Different combinations of plastic scintillators and QD were built and their emission spectra were studied. We established a preferential order for the scintillating components in the context of an optimized 2-points mPSD. In short, the components with higher wavelength emission spectrum should be distal and lower wavelength in the proximal position.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of new Polysiloxane Based Liquid Scintillators

In the last decade, attention toward neutron detection has been growing in the scientific community, driven by new requirements in different fields of application ranging from homeland security to medical and material analysis, from research physics, to nuclear energy production. So far neutron detection, with particular attention to fast neutrons, has been mainly based on organic liquid scintillators, owing to their good efficiency and pulse shape discrimination (PSD) capability. Most of these liquids have however some main drawbacks given by toxicity, flammability, volatility and sensitivity to dissolved oxygen that limits the duration and the quality of their performances with worse handiness and increased costs. Phenyl-substituted polysiloxanes could address most of these issues, being characterized by low toxicity, low volatility and low flammability. Their optical properties can be tailored by changing the phenyl distribution and concentration thus allowing to increase the solubility of organic dyes, to modify the fluorescence spectra and to vary the refractive index of the medium. Furthermore, polysiloxanes have been recently exploited for the production of plastic scintillators with very good chemical and thermal stability and very good radiation hardness and the development of polysiloxane liquid scintillators could allow to combine these interesting properties with the supremacy of liquid scintillators as regarding PSD over plastics. For these reasons, the properties of several phenyl-substituted polysiloxane with different phenyl amounts and different viscosities have been investigated, with particular attention to the scintillation response and the pulse shape discrimination capability, and the results of the investigation are reported in this work. More in details, the scintillation light yield towards gamma rays ({sup 60}Co and {sup 137}Cs) of several polysiloxane liquids has been analyzed and compared with the light yield of a commercial non-toxic liquid scintillator (EJ309). The results have been related to the optical characterization of these materials, especially as regarding the fluorescence response, and the best performing material (1,1,5,5-Tetraphenyl 1,3,3,5-Tetramethyl Trisiloxane) showed a scintillation light-yield only slightly lower than EJ309, proving to be a promising candidate for the production of an efficient polysiloxane based liquid scintillator. The results as regarding the neutron-gamma pulse shape discrimination capability of the best performing materials are also reported in this work and the scintillation decay time of these materials are compared to the results of fluorescence lifetime analysis. PSD tests have been performed at CN accelerator in Legnaro National Laboratories with a 2.2 MeV pulsed neutron beam using TOF procedure and the pulses have been analyzed in order to evidence the PSD capability of every sample. The reported results pave the way to the development of a new promising class of non-toxic liquid scintillating materials for neutron detection, with good light output and interesting PSD characteristics. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Boron-Based Neutron Scintillator Screens for Neutron Imaging

In digital neutron imaging, the neutron scintillator screen is a limiting factor of spatial resolution and neutron capture efficiency and must be improved to enhance the capabilities of digital neutron imaging systems. Commonly used neutron scintillators are based on 6 LiF and gadolinium oxysulfide neutron converters. This work explores boron-based neutron scintillators because 10 B has a neutron absorption cross-section four times greater than 6Li, less energetic daughter products than Gd and 6 Li, and lower γ-ray sensitivity than Gd. These factors all suggest that, although borated neutron scintillators may not produce as much light as 6 Li-based screens, they may offer improved neutron statistics and spatial resolution. This work conducts a parametric study to determine the effects of various boron neutron converters, scintillator and converter particle sizes, converter-to-scintillator mix ratio, substrate materials, and sensor construction on image quality. The best performing boron-based scintillator screens demonstrated an improvement in neutron detection efficiency when compared with a common 6 LiF/ZnS scintillator, with a 125% increase in thermal neutron detection efficiency and 67% increase in epithermal neutron detection efficiency. The spatial resolution of high-resolution borated scintillators was measured, and the neutron tomography of a test object was successfully performed using some of the boron-based screens that exhibited the highest spatial resolution. For some applications, boron-based scintillators can be utilized to increase the performance of a digital neutron imaging system by reducing acquisition times and improving neutron statistics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of scintillator-based detectors for few-ten-keV high-spatial-resolution x-ray imaging

Purpose: High-spatial-resolution x-ray imaging in the few-ten-keV range is becoming increasingly important in several applications, such as small-animal imaging and phase-contrast imaging. The detector properties critically influence the quality of such imaging. Here the authors present a quantitative comparison of scintillator-based detectors for this energy range and at high spatial frequencies. Methods: The authors determine the modulation transfer function, noise power spectrum (NPS), and detective quantum efficiency for Gadox, needle CsI, and structured CsI scintillators of different thicknesses and at different photon energies. An extended analysis of the NPS allows for direct measurements of the scintillator effective absorption efficiency and effective light yield as well as providing an alternative method to assess the underlying factors behind the detector properties. Results: There is a substantial difference in performance between the scintillators depending on the imaging task but in general, the CsI based scintillators perform better than the Gadox scintillators. At low energies (16 keV), a thin needle CsI scintillator has the best performance at all frequencies. At higher energies (28–38 keV), the thicker needle CsI scintillators and the structured CsI scintillator all have very good performance. The needle CsI scintillators have higher absorption efficiencies but the structured CsI scintillator has higher resolution. Conclusions: The choice of scintillator is greatly dependent on the imaging task. The presented comparison and methodology will assist the imaging scientist in optimizing their high-resolution few-ten-keV imaging system for best performance.

60 APPLIED LIFE SCIENCES↗

Spacecraft Radio Scintillation and Solar System Exploration

When a wave propagates through a turbulent medium, scattering by the random refractive index inhomogeneities can lead to a wide variety of phenomena that have been the subject of extensive study. The observed scattering effects include amplitude or intensity scintillation, phase scintillation, angular broadening, and spectral broadening, among others. In this paper, I will refer to these scattering effects collectively as scintillation. Although the most familiar example is probably the twinkling of stars (light wave intensity scintillation by turbulence in the Earth's atmosphere), scintillation has been encountered and investigated in such diverse fields as ionospheric physics, oceanography, radio astronomy, and radio and optical communications. Ever since planetary spacecraft began exploring the solar system, scintillation has appeared during the propagation of spacecraft radio signals through planetary atmospheres, planetary ionospheres, and the solar wind. Early studies of these phenomena were motivated by the potential adverse effects on communications and navigation, and on experiments that use the radio link to conduct scientific investigations. Examples of the latter are radio occultation measurements (described below) of planetary atmospheres to deduce temperature profiles, and the search for gravitational waves. However,these concerns soon gave way to the emergence of spacecraft radio scintillation as a new scientific tool for exploring small-scale dynamics in planetary atmospheres and structure in the solar wind, complementing in situ and other remote sensing spacecraft measurements, as well as scintillation measurements using natural (celestial) radio sources. The purpose of this paper is to briefly describe and review the solar system spacecraft radio scintillation observations, to summarize the salient features of wave propagation analyses employed in interpreting them, to underscore the unique remote sensing capabilities and scientific relevance of the scintillation measurements, and to highlight some of the scientific results obtained to date. Special emphasis is placed on comparing the remote sensing features of planetary and terrestrial scintillation measurements, and on contrasting spacecraft and natural radio source scintillation measurements. I will first discuss planetary atmospheres and ionospheres, and then the solar wind.

Woo, Richard↗

SU-E-T-763: Towards the Mechanical Doping of Plastic Scintillators

Purpose: The doping of plastic scintillators with high-Z elements changes the radiation interaction cross section of the medium and therefore changes the intrinsic response of the detector. The selection of doped plastic scintillators available commercially is limited. This research aims to develop a novel methodology for the mechanical doping of plastic scintillating materials. The ultimate goal of this project is to use doped scintillators of varying intrinsic behavior to unfold the LET (energy) spectrum of any radiation beam. Methods: Commercially available BC408 plastic scintillator was obtained and crushed into uniform powder (using ball mill). Two separate materials were tested for light output signal: uncrushed scintillator and scintillating powder bound by glue. Commercially available U301 UV-hardening glue was used. Scintillation response was measured by creating a thin housing of black acrylic that allowed light from each scintillator to be guided to an optical fiber via a taper. The optical fiber was connected to a PMT; signal was measured using an electrometer. Tests were conducted to determine if crushing+bonding distorted linearity and energy dependence of detector response. Linearity was tested for by irradiating (uncrushed and crushed+glued) for varying durations ensuring signal scaled accordingly; this was done using 300kV x-rays and 6MeV electrons. The effect on energy dependence was examined by obtaining a signal ratio (100kV vs. 300kV; 6MeV vs. 18MeV) for both uncrushed and crushed+glued scintillating material. Results: Crushing and binding with U301 glue did not have an effect on linearity. Energy dependence was changed by 20.3%; crushing+bonding decreased the sensitivity at low energy radiation. Conclusion: This work indicates that crushing and binding of plastic scintillating material does not change the linearity of its response to radiation but does have an effect on the energy dependence. Future work involves addition of high-Z dopants (W, Mo, Pb) and characterization of the detector response.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced inorganic halide ceramic scintillators

Research in ceramic scintillators has steadily progressed alongside the research in bulk single crystal scintillator growth. As interest in faster scintillation material production with lower cost increases, more research on scintillating ceramics is needed. Research targeting optimization of optically transparent ceramics that can rival bulk-grown crystals grown may lower cost, increase yield, increase volume, and improve energy resolution in applications and systems currently using sodium iodide and alike. Ceramic scintillators that are dense (>5 g/cm 3 ), have high effective Z (>60), are bright (>40,000 photons/MeV), and are not sensitive to moisture as well as those that can be handled without protection are desired. Ultra-fast ceramic materials are also of interest. This paper presents an equipment design and technique to produce inorganic halide ceramic scintillators Cs 2 HfCl 6 (CHC) and Tl 2 HfCl 6 (THC). Improvements and optimization of CHC and THC ceramic scintillator fabrication are gauged by monitoring the energy resolution and peak position of 137 Cs full energy peak at 662 keV. With a 1-inch diameter CHC ceramic scintillator, energy resolution of 5.4% (FWHM) and light yield of 20,700 ph/MeV are achieved, while with a 16-mm diameter THC ceramic scintillator, energy resolution of 5.1% (FWHM) and light yield of 27,800 ph/MeV are achieved. Decay times of 0.6 μs (21%) and 3.0 μs (79%) are measured for CHC and 0.3 μs (13%) and 1.0 μs (87%) for THC. Here, both ceramic CHC and THC scintillators have similarly good proportionality data when compared to their single crystal counterparts.

36 MATERIALS SCIENCE↗

SU-E-T-782: Using Light Output From Doped Plastic Scintillators to Resolve the Linear Energy Transfer Spectrum of Clinical Electron Beams

Purpose: This research seeks to develop a portable, clinically-suitable linear energy transfer (LET) detector. In radiotherapy, absorbed dose is commonly used to measure the amount of delivered radiation, though, it is not a good indicator of actual biological damage. LET is the energy absorbed per unit length by a medium along charged particle’s pathway; studies have shown that LET correlates well with relative biological effectiveness (RBE). Methods: According to Birks’ law, light output of plastic scintillators is stopping-power dependent. This dependency can be varied through doping by various high-Z elements. By measuring light output signals of differently doped plastic scintillators (represented by column vector S, where each row corresponds to different scintillator material), the fluence of charged particles of a given LET (represented by column vector Φ, where each row corresponds to different LET bins) can be unfolded by S=R*Φ where R is system response matrix (each row represents a different scintillator, each column corresponds to different electron LET). Monte Carlo (MC) GEANT4.10.1 was used to evaluate ideal detector response of BC408 scintillating material doped with various concentrations of several high Z dopants. Measurements were performed to validate MC. Results: Signal for 1%-lead doped BC408 and the non-doped scintillator was measured experimentally by guiding light emitted by the scintillator (via in-house made taper, fiber system) to a PMT and then an electrometer. Simulations of 1%Pb-doped scintillator to non-doped scintillator revealed 9.3% reduction in light output for 6 MeV electrons which compared well (within uncertainty) with measurements showing 10% reduction (6MeV electrons). Conclusion: Measurements were used to validate MC simulation of light output from doped scintillators. The doping of scintillators is a viable technique to induce LET dependence. Our goal is to use this effect to resolve the LET spectrum of an incident beam.

60 APPLIED LIFE SCIENCES↗

Scintillator Efficiency Study with MeV X-Rays

We have investigated scintillator efficiency for MeV radiographic imaging. This paper discusses the modeled detection efficiency and measured brightness of a number of scintillator materials. An optical imaging camera records images of scintillator emission excited by a pulsed x-ray machine. The efficiency of various thicknesses of monolithic LYSO:Ce (cerium-doped lutetium yttrium orthosilicate) are being studied to understand brightness and resolution trade-offs compared with a range of micro-columnar CsI:Tl (thallium-doped cesium iodide) scintillator screens. The micro-columnar scintillator structure apparently provides an optical gain mechanism that results in brighter signals from thinner samples. The trade-offs for brightness versus resolution in monolithic scintillators is straightforward. For higher-energy x-rays, thicker materials generally produce brighter signal due to x-ray absorption and the optical emission properties of the material. However, as scintillator thickness is increased, detector blur begins to dominate imaging system resolution due to the volume image generated in the scintillator thickness and the depth of field of the imaging system. We employ a telecentric optical relay lens to image the scintillator onto a recording CCD camera. The telecentric lens helps provide sharp focus through thicker-volume emitting scintillators. Stray light from scintillator emission can also affect the image scene contrast. We have applied an optical light scatter model to the imaging system to minimize scatter sources and maximize scene contrasts.

scintillator, radiography, CCD camera, hard x-ray,↗