Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCADA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A Robust State Estimation Framework Considering Measurement Correlations and Imperfect Synchronization

This paper develops a robust power system state estimation framework with the consideration of measurement correlations and imperfect synchronization. In the framework, correlations of SCADA and PMU measurements are calculated separately through unscented transformation and a vector autoregression (VAR) model. In particular, PMU measurements during the waiting period of two SCADA measurement scans are buffered to develop the VAR model. The latter takes into account the temporal and spatial correlations of PMU measurements and provides redundant measurements to suppress bad data and mitigate imperfect synchronization. In case of synchronization issues between SCADA and PMU measurements, either forecasted PMU measurements or prior SCADA measurements from the last estimation run are leveraged to restore system observability. After that, robust generalized maximum-likelihood (GM)-estimator is developed to integrate full measurement correlations and handle bad data in SCADA and PMU measurements. Thanks to the robustness and flexibility of the proposed robust estimator, bad data as well as imperfect measurement synchronization are mitigated, yielding high statistical efficiency. Comprehensive comparison results with other alternatives under various conditions demonstrate the benefits of the proposed framework.

Zhao, Junbo (ORCID:0000000284989666)↗

Pre-commercial Demonstration of Direct Non-iterative State Estimator for Operational Use of Synchrophasor Management Systems

The objective of this project was to demonstrate functionality and performance of a Direct Non-iterative State Estimator (DNSE) integrated with NYPA’s Energy Management System (EMS) and with enhanced Real Time Dynamics Monitoring System (RTDMS) synchrophasor platform from Electric Power Group (EPG). DNSE is designed to overcome a major obstacle to operational use of Synchro-Phasor Management Systems (SPMS) by providing to synchrophasor management systems (SPMS) applications a consistent and a complete synchrophasor data foundation in the same way that a traditional EMS State Estimator (SE) provides to EMS applications. Specifically, DNSE is designed to use synchrophasor measurements collected by a central PDC, Supervisory Control and Data Acquisition (SCADA) measurements, and Energy Management System (EMS) network model, to obtain the complete state of the utility’s operating model at rates that are close to the synchrophasor data rates. In this way, the system is comprehensive in that it does not only cover the part of the network that is “visible” via synchrophasors, but also the part that is only “visible” through the SCADA measurements. Visualization needs associated with the use of DNSE results are fulfilled through suitably enhanced Real Time Dynamics Monitoring System (RTDMS), with the enhancements implemented by EPG. This project had the following goals in mind: To advance the deployment of commercial grade DNSE software application that relies on synchrophasor and SCADA data ; Apply DNSE at other utilities, to address a generic and fundamental need for “clean” operational data for synchrophasor applications; Provide means for “live” estimated data access by control system operators; Enhance potential for situational awareness through full system operational model coverage; Sub-second execution rate of the Direct Non-iterative State Estimator, eventually at a near-phasor data rate execution speed, i.e. < 0.1 sec. Anticipated benefits from this projects are: Enhanced reliability and improvements in the economic efficiency of bulk power system planning and operations; Providing “clean” data to other synchrophasor applications; Enhancement of situational awareness by providing the full operational model updated at near synchrophasor rate; A production-grade software tool that incorporate synchrophasor and SCADA data; Provides a basis for development of next generation monitoring and control applications, based on both SCADA and PMU data. Quanta Technology (QT) team worked in collaboration with Electric Power Group (EPG) whose team has enhanced its commercial Real Time Dynamics Monitoring System (RTDMS) to accommodate the requirements posed by DNSE application. EPG also provided its ePDC and Model-less Data Conditioning (PDVC) software for integration with DNSE+. QT developed the system requirements for DNSE; developed system architecture and defined interfaces between internal DNSE components. The core DNSE algorithm with all surrounding interfaces was named DNSE+. Since the DNSE development was done in a simulated system environment, QT used its PMU simulator that was enhanced during this project for development and factory acceptance testing (FAT). SCADA data in this stage was simulated by commercial PSS/e software. The output of DNSE are estimates of System states in C37.118-2 format, sent to RTDMS for further processing and display. As the number of these states is large, it was necessary to expand the C37.111-2 standard to accommodate large data sets. This enhancement was implemented in RTDMS. The demonstration of pre-production DNSE technology was done at NYPA using streaming field data from NYPA PMUs and from its RTUs through their SCADA system. NYPA provided ICCP interface as well as Common Information Model (CIM). The relevance of the DNSE+ application is that it provides state estimation of the power system based on hybrid set of data, consisting of both available PMU data and SCADA measurements. As this is a direct, non-iterative method of calculation of the system states, if does not suffer from convergence issues which is potential problem for conventional state estimators. Also, it can take any available PMU measurements, so it does not need to have a high percentage of PMU coverage needed in the case of Linear State Estimator. As the DNSE calculates synchrophasors of the system states (both phase and absolute value) as sub-second rate, this application can provide a basis for development of next generation of applications based both on SCADA and PMU data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

E1 Illumination of a Substation Protection System

Sandia’s CRADA partnership with EPRI for calendar year 2017 helped further the technical basis of understanding on the effects to the electric power distribution system infrastructure (i.e., the grid), from a high altitude electromagnetic pulse (HEMP) event. This joint effort yielded evaluation of multiple SCADA relays to very high transient electric fields that were comparable in frequency content to a HEMP event, in multiple equipment configurations that are representative to how the units are fielded and utilized. Both Sandia and EPRI benefit from the data collected. Sandia directly benefits the LDRD effort to address EMP on electrical system infrastructures. EPRI direct benefits the stakeholders they are representing in the power industry. Stakeholders are power generation and distribution companies and equipment manufactures. The results would be used for product improvement and EMP hardening as well as informing the customer base of potential shortfalls of the product to a HEMP event.To better understand the impacts of HEMP on supervisory control and data acquisition (SCADA) systems in typical use at bulk power facilities, Sandia and EPRI has brought together their unique skills and equipment/facilities. EPRI, representing the stakeholders of the power industry, brings technical experience of how supervisory control and data acquisition (SCADA) systems are typically fielded and utilized in real-world applications. With this, EPRI will provides field hardware relating to the SCADA systems. Sandia National Laboratories (Sandia) provides unique test facilities (Sandia’s Electromagnetic Environment Simulator (EMES) and Large Gigahertz Transverse Electromagnetic (GTEM)) and test equipment capabilities to evaluate the SCADA systems to a simulated HEMP event. Sandia brings hands on experience of conducting susceptibility and vulnerability assessments for critical components and systems to high power incident HEMP illumination.

Molina, Luis↗

Investigation of Multiple Data Streams for Gearbox Bearing Fault Prediction Through Machine-Learning Models

Operations and maintenance (O&M) cost of wind plant accounts up to 30% of total energy cost, which can be reduced through continuous monitoring and successfully detecting incipient wind turbine failures. To accomplish this, condition monitoring and predictive maintenance systems are being implemented in wind industry to support O&M decision making. A wide range of approaches for condition monitoring and fault prediction have been developed. These approaches generally use historical data of wind turbines collected by Supervisory Control and Data Acquisition (SCADA) system to identify patterns that lead to failure. These SCADA data show the overall condition of a wind turbine and can be leveraged to detect when the turbine's performance is degrading and to identify if a fault is developing. However, it becomes challenging to predict the failure of a specific wind turbine gearbox bearing, because the SCADA data are often not directly linked to the component. To bridge the gap, we have investigated features calculated from SCADA data using physics-based models and the gearbox design over the years. The damaged metric we used in the physics domain is frictional energy. Combining these physics domain variables with SCADA data as inputs to various machine learning models for gearbox bearing fault prediction, we have demonstrated the benefits of leveraging both physics and data domain models. It was an attempt to improve frictional-energy-based damage metric by adding data domain inputs, as we had learned that the frictional-energy-based damage metric alone is not sufficient to single out failed bearings from healthy. As condition monitoring data (either vibration or oil debris data) has become available at more and more wind plants, we would like to evaluate whether by adding the condition monitoring data can help further improve the performance of frictional-energy-based damage metric for gearbox bearing fault prediction. Both cases by modeling through various machine learning algorithms are discussed in this study along with some observations.

fault prediction↗

Achieving Runtime State Verification Assurance in Critical Cyber-Physical Infrastructures

Industrial Cyber-Physical Systems (ICPS) are an essential backbone of national critical infrastructures. They help monitor and control crucial cyber-enabled services such as energy generation. Commonly ICPS monitors the physical process through Supervisory Control and Data Acquisition (SCADA) systems. The SCADA ecosystem takes critical real-time and future system operational decisions based on the runtime state behavior of field sensors. Traditional SCADA systems use legacy and insecure communication protocols such as the Modbus protocol that lack adequate security mechanisms to provide robust runtime state behavior assurance of constrained field sensors. Therefore, constrained field sensors are commonly vulnerable to standard semantic attacks that gradually change the behavior state of infected devices. This paper discusses process integrity assurance techniques necessary to enhance the security of behavior-based protocols such as the Modbus protocol. The Runtime State Verification (RSV) protocol proposed in this paper aims to address semantic attacks in the SCADA ecosystem by integrating behavior-based Mandatory Results Automata (MRA) and a Hyperledger Fabric (HLF) network. The RSV protocol provides high process integrity assurance through enhanced behavior-based MRA suitable for the constrained field devices. A proof of concept of the RSV protocol has been evaluated in an emulated water-tube boiler. Preliminary evaluations of the RSV protocol aimed to measure the efficiency of the proposed protocol by monitoring an Combustion Efficiency (CE) process necessary to preserve optimal combustion, thus minimizing costs and future maintenance of water-tube boilers. We analyze the overall network overhead and latency of the proposed RSV protocol by evaluating the HLF network performance and comparing the proposed RSV protocol with the state-ofart BloSPAI protocol. Through the preliminary evaluations of the proposed RSV protocol, this paper demonstrates that the proposed RSV protocol overcomes the shortcomings and network overhead of the BloSPAI protocol by integrating behavior-based authentication through novel MRAs and HLF networks.

Rivera, Abel Gomez↗

Development and Demonstration of a Security Core Component

In recent years, the convergence of a number of trends has resulted in Cyber Security becoming a much greater concern for electric utilities. A short list of these trends includes: · Industrial Control Systems (ICSs) have evolved from depending on proprietary hardware and operating software toward using standard off-the-shelf hardware and operating software. This has meant that these ICSs can no longer depend on “security through obscurity. · Similarly, these same systems have evolved toward using standard communications protocols, further reducing their ability to rely upon obscurity. · The rise of the Internet and the accompanying demand for more data about virtually everything has resulted in formerly isolated ICSs becoming at least partially accessible via Internet-connected networks. · “Cyber crime” has become commonplace, whether it be for industrial espionage, reconnaissance for a possible cyber attack, theft, or because some individual or group “has something to prove.” Electric utility system operators are experts at running the power grid. The reality is, especially at small and mid-sized utilities, these SCADA operators will by default be “on the front line” if and when a cyber attack occurs against their systems. These people are not computer software, networking, or cyber security experts, so they are ill-equipped to deal with a cyber security incident. Cyber Security Manager (CSM) was conceived, designed, and built so that it can be configured to know what a utility’s SCADA/EMS/DMS system looks like under normal conditions. To do this, CSM monitors log messages from any device that uses the syslog standard. It can also monitor a variety of statistics from the computers that make up the SCADA/EMS/DMS: outputs from host-based security tools, intrusion detection systems, SCADA alarms, and real-time SCADA values – even results from a SIEM (Security Information and Event Management) system. When the system deviates from “normal,” CSM can alert the operator in language that they understand that an incident may be occurring, provide actionable intelligence, and informing them what actions to take. These alarms may be viewed on CSM’s built-in user interface, sent to a SCADA alarm list, or communicated via email, phone, pager, or SMS message. In recognition of the fact that “real world” training for cyber security events is impractical, CSM has a built-in Operator Training Simulator capability. This can be used stand alone to create simulated event scenarios for training purposes. It may also be used in conjunction with the recipient’s SCADA/EMS/DMS Operator Training Simulator. In addition to providing cyber security situational awareness for electric utility operators, CSM also provides tools for analysts and support personnel; in fact, the majority of user interface displays are designed for use in analyzing current and past security events. CSM keeps security-related information in long-term storage, as well as writing any decisions it makes to a (syslog) log for use forensic or other post-event analysis.

Turke, Andy↗

HIDES: Hybrid Intrusion Detector for Energy Systems

The establishment of a resilient electric grid accompanied by a secure communications network is an ongoing battle as advanced persistent threats continue to exploit existing vulnerabilities in legacy supervisory control and data acquisition system (SCADA) infrastructure. Traditional intrusion detection systems (IDSs) lack consistent performance because of the continuously evolving attack surface of SCADA systems. These shortcomings can be overcome by integrating logical system behavior, protocol-specific knowledge, and data-based learning to develop a comprehensive IDS solution. In this paper, we present a Hybrid Intrusion Detector for Energy Systems by integrating a network-based IDS, state-of-the-art machine learning-based IDS, and model-based IDS to detect unknown and stealthy cyberattacks targeting the SCADA networks. The proposed IDS uses synchrophasor measurements and cyber logs to learn patterns of different scenarios based on spatiotemporal behaviors of power systems. As a proof of concept, we implement and validate the proposed IDS by leveraging resources available at the National Renewable Energy Laboratory's Energy Systems Integration Facility test bed. Experimental results show promising performance in detecting cyberattacks while providing realtime visualization of power system measurements and cyber logs.

machine-learning intrusion detection system↗

AOI-2, A Novel Access Control Blockchain Paradigm for Cybersecure Sensor Infrastructure in Fossil Power Generation Systems

Fossil power generation systems are increasingly vulnerable to attack from both cybercriminals as well as internal threats. These vulnerabilities demand that emerging technologies such as blockchains be utilized to secure the data involved in the information flows within the Supervisory Control and Data Acquisition (SCADA) systems of the fossil power generation plants. The publicly accessible blockchain protocols, although secure, are visible to everyone. Even private blockchains currently are unable to support different levels of access to different participants, which is a critical requirement for the existing SCADA systems running the power plants. In light of the above, novel blockchain protocols that are specifically adapted to fossil power generation environments need to be developed in order to achieve the goal of cybersecure sensor networks. In this work, we address this question by creating a novel blockchain technology, namely smart private ledger, for cybersecure communication within the fossil power generation systems. A lab-scale sensor network consisting of strain and temperature sensors is constructed to develop the ledger. The technology has hierarchical access control which is compatible with the existing SCADA systems in fossil power plants. The sensor data is used with cryptographic digital signatures and secret sharing protocols within the nodes of the blockchain technology. The research results will lead to cybersecurity for machine-to-machine interactions, infrastructure for secure data logging for sensors, decentralized data storage, and second-layer technologies for high volume machine-to-machine interactions in the power plants. The work aims to largely address the concerns for the security of distributed sensor networks in such systems that can be compromised by insider threats and by cybercriminals. The research has led to the training of the next generation of engineers and scientists in the important areas of sensor engineering and blockchain technology.

01 COAL, LIGNITE, AND PEAT↗

Developing and Evaluating a Smart Curtailment Strategy Integrated with a Wind Turbine Manufacturer Platform

The Renewable Energy Wildlife Institute lead a team of scientists, wind developers, and turbine manufacturers in a study to develop and test a “smart curtailment” system intended to help reduce bat collisions with wind turbines. The Vestas Bat Protection System (VBPS) is a newly developed software module within the Supervisory Control and Data Acquisition (SCADA) system of Vestas turbines. The VBPS combines data from commercially available environmental sensors and the turbine’s built-in sensors with the Vestas SCADA system. VBPS is designed to receive environmental data from sensors on the turbine such as temperature, wind speed, wind direction, time of day, and time of year, relays that information to the SCADA system to determine whether to execute turbine curtailments at any given time. The goals of this study were to 1) develop a bat fatality risk model based on bat activity data and environmental data collected in year 1, and to 2) evaluate the VBPS, using the bat fatality risk model to implement curtailment, in comparison to “blanket curtailment” (turbines curtailed when wind speed is below 5.0 meters per second (m/s)) and “control” (normally operating, feathered below 3.0 m/s) turbines in year 2. The field study took place at a wind energy facility in Iowa during the fall bat migration seasons (July – October) in 2021 and 2022. For VBPS to succeed as a viable strategy for the minimization of bat fatalities, it should meet or exceed the performance of blanket curtailment. Specifically, the VBPS should meet the following performance targets to demonstrate whether it an effective, practical risk reduction measure: (1) Turbines operating VBPS should have equal or fewer bat fatalities compared to turbines operating with blanket curtailment, and significantly fewer bat fatalities compared to control turbines; and (2) Turbines operating VBPS should have greater power production compared to turbines operating with blanket curtailment. The study was completed in accordance with the Statement of Project Objectives and within the terms of the Budget Justification. This Final Report describes the progress, challenges, and outcomes of the study.

17 WIND ENERGY↗

Quantifying the Impact of Unavailability in Cyber-Physical Environments

The Supervisory Control and Data Acquisition (SCADA) system discussed in this work manages a distributed control network for the Tunisian Electric & Gas Utility. The network is dispersed over a large geographic area that monitors and controls the flow of electricity/gas from both remote and centralized locations. The availability of the SCADA system in this context is critical to ensuring the uninterrupted delivery of energy, including safety, security, continuity of operations and revenue. Such SCADA systems are the backbone of national critical cyber-physical infrastructures. Herein, we propose adapting the Mean Failure Cost (MFC) metric for quantifying the cost of unavailability. This new metric combines the classic availability formulation with MFC. The resulting metric, so-called Econometric Availability (EA), offers a computational basis to evaluate a system in terms of the gain/loss ($/hour of operation) that affects each stakeholder due to unavailability.

Availability↗

A symmetric address translation approach for a network layer moving target defense to secure power grid networks

This paper will suggest a robust method for a network layer Moving Target Defense (MTD) using symmetric packet scheduling rules. The MTD is implemented and tested on a Supervisory Control and Data Acquisition (SCADA) network testbed. This method is shown to be efficient while providing security benefits to the issues faced by the static nature of SCADA networks. The proposed method is an automated tool that may provide defense in depth when be used in conjunction with other MTDs and traditional security devices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Virtual sensing of wind turbine hub loads and drivetrain fatigue damage, Virtuelle Sensoren für die Messung von Hauptwellenlasten und Ermüdungsschäden im Antriebstrang von Windenergieanlagen

Abstract: This paper presents a Digital Twin for virtual sensing of wind turbine aerodynamic hub loads, as well as monitoring the accumulated fatigue damage and remaining useful life in drivetrain bearings based on measurements of the Supervisory Control and Data Acquisition (SCADA) and the drivetrain condition monitoring system (CMS). The aerodynamic load estimation is realized with data-driven regression models, while the estimation of local bearing loads and damage is conducted with physics-based, analytical models. Field measurements of the DOE 1.5 research turbine are used for model training and validation. The results show low errors of 6.4% and 1.1% in the predicted damage at the main and the generator side high-speed bearing respectively. Zusammenfassung: In diesem Aufsatz wird ein digitaler Zwilling für Windenergieanlagen vorgestellt, welcher die virtuelle Erfassung der Hauptwellenlasten und die Zustandsüberwachung von Ermüdungschäden und der verbleibende Nutzungsdauer der Antriebsstranglager ermöglicht. Der digital Zwilling nutzt Messdaten des Supervisory Control and Data Acquisition (SCADA) Systems und des Zustandsüberwachungssystems des Antriebsstranges (CMS). Die Berechnung der Hauptwellenlasten ist mit datenbasierten Regressionsmodellen umgesetzt, während die Berechnung der Lagerkräfte und der Ermüdungsschaden mit physikbasierten Modelle durchgeführt wird. Für die Modellentwicklung und -validierung werden Feldmessdaten der DOE 1.5MW Turbine eingesetzt. Die Abweichungen in den Ermüdungsschäden am Hauptwellenlager und am Generatorwellenlager betragen lediglich 6,4% beziehungsweise 1,1%.

17 WIND ENERGY↗

Cyber-Physical Smart Light Control System Integration with Smart Grid using Zigbee

This paper presents a hardware-in-the-loop cyber-physical system architecture design to monitor and control smart lights connected to the active distribution grid. The architecture uses Zigbee-based (IEEE 802.15.4) wireless sensor networks and publish-subscribe architecture to exchange monitoring and control signals between smart-light actuators (SLAs) and a smart-light central controller (SLCC). Each SLA integrated into a smart light consists of a Zigbee-based endpoint module to send and receive signals to and from the SLCC. The SLCC consists of a Zigbee-based coordinator module, which further exchanges the monitoring and control signals with the active distribution management system over the TCP/IP communication network. The monitoring signals from the SLAs include light status, brightness level, voltage, current, and power data, whereas, the control signals to the SLAs include light intensity, turn ON, turn OFF, standby, and default settings. We have used our existing hardware-in-the-loop (HIL) cyber-physical system (CPS) security SCADA testbed to process signals received from the SLCC and respond suitable control signals based on the smart light schedule requirements, system operation, and active distribution grid dynamic characteristics. We have integrated the proposed cyber-physical smart light control system (CPSLCS) testbed to our existing HIL CPS SCADA testbed. We use the integrated testbed to demonstrate the efficacy of the proposed algorithm by real-time performance and latency between the SLCC and SLAs. The experiments demonstrated significant results by 100% realtime performance and low latency while exchanging data between the SLCC and SLAs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Parallel State Estimation Assessment with Practical Data

This paper presents a full-cycle parallel state estimation (PSE) implementation using a preconditioned conjugate gradient algorithm. The developed code is able to solve large-size power system state estimation within 5 seconds using real-world data, comparable to the Supervisory Control And Data Acquisition (SCADA) rate. This achievement allows the operators to know the system status much faster to help improve grid reliability. Case study results of the Bonneville Power Administration (BPA) system with real measurements are presented. The benefits of fast state estimation are also discussed.

State Estimation, Preconditioned Conjugate Gradien↗

Real-World Distribution System Modeling Framework for Transmission-and-Distribution Cosimulation: Preprint

This paper presents a modeling methodology for realistic distribution system simulation and analysis. The methodology involves three major approaches: utility model conversion, feeder load modeling, and feeder model validation. The feeder models obtained from the utility are converted to the format that is more flexible for analysis and algorithm development. The load profiles down to each node are modeled in detail using advanced metering infrastructure data and supervisory control and data acquisition (SCADA) system measured load data. Then the distribution system models are validated by comparing the simulated feeder-head voltage results and SCADA measured voltage data. To better understand the bulk system operations and the interactions between transmission and distribution systems, the modeled realistic distribution systems are integrated into a transmission-and-distribution cosimulation framework to perform the system simulation from the bulk system down to each node in the distribution system.

load modeling↗

Power Plant Model Validation Tool

The PPMV is used to validate generator model using disturbance recordings. The PPMV tool contains a collection of power plant models and model validation studies, as well as disturbance recordings from a number of historic grid events. The user can import data from a new disturbance into the database, which converts PMU and SCADA data into GE PSLF format, and then run the tool to validate (or invalidate) the model for a specific power plant against its actual performance. The PNNL PPMV tool enables the automation of the process of power plant model validation using disturbance recordings. The tool uses PMU and SCADA measurements as input information. The tool automatically adjusts all required EPCL scripts and interacts with GE PSLF in the batch mode. The main tool features includes: The tool interacts with GE PSLF; The tool uses GE PSLF Play-In Function for generator model validation; Database of projects (model validation studies); Database of the historic events; Database of the power plant; The tool has advanced visualization capabilities; and the tool automatically generates reports.

Source record↗

HIDES (Hybrid Intrusion Detection for Energy Systems) [SWR-19-65]

Hybrid Intrusion Detection for Energy Systems (HIDES) is a conglomerate detector that incorporates three major components: (1) Signature-based detection that involves information technology (IT) related anomaly detection rules, (2) Behavior-based detection that utilizes specially crafted rulesets for detecting abnormal behavior regarding the power system's supervisory control and data acquisition (SCADA) communication streams, and (3) Learning-based detection that combines SCADA communication with phasor measurements to identify otherwise non-detectible attack vectors. The software itself interconnects intrusion detection engine (IDE) enabling communications between the generated OT and IT alerts with phasor measurements for the learning-based detection system. The resulting detection system can detect a wide array of IT, OT, and physical attacks in a real-time setting.

Rivera, Joshua↗

Sophia Daemon Version 12

Sophia Daemon Version 12 contains the code that is exclusively used by the sophiad application. It runs as a service on a Linux host and analyzes network traffic obtained from libpcap and produces a network fingerprint based on hosts and channels. Sophia Daemon Version 12 can, if desired by the user, produce alerts when its fingerprint changes. Sophia Daemon Version 12 can receive data from another Sophia Daemon or raw packet data. It can output data to another Sophia Daemon Version 12, OglNet Version 12 or MySQL. Sophia Daemon Version 12 runs in a passive real-time manner that allows it to be used on a SCADA network. Its network fingerprint is designed to be applicable to SCADA networks rather than general IT networks.

Verba, JaredA.↗