Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Relative accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Particle signal considerations for isotope ratio analysis with single particle multi-collector inductively coupled plasma mass spectrometry

Particle analysis has benefitted from the advent of single particle inductively coupled plasma-mass spectrometry (spICP-MS) due to its robustness, sensitivity, and high-throughput nature. Previous methods of spICP-MS have typically utilized quadrupole or time-of-flight mass analyzers and therefore employ electron multiplier-based detectors (such as secondary electron multipliers or microchannel plates). However, to obtain precise measurements on elemental or isotopic ratios within individual particles, multi-collector ICP-MS (MC-ICP-MS) can be used. Here, we investigate Ce isotope ratios, specifically 142 Ce/ 140 Ce, by spMC-ICP-MS using an all-Faraday cup collector array. Using 1 μm (diameter) cerium dioxide particles, integration times of the Faraday cup detectors were varied from 50–500 ms. The signal from the cerium isotopes in the particles was used to determine isotope ratios, which closely matched the expected natural isotopic abundances. Due to the signal decay response from the Faraday cups, the signal from particles lasts much longer than the expected 1–2 ms (up to 100 s of ms). To explore this effect on isotope ratio analysis, multiple ratio analysis methods were used to determine how to obtain optimal precision and accuracy. Relative differences were around 2% for methods that calculated isotope ratios from summing the total signal of an individual particle before calculating the ratio (rather than using every data point individually). It was found that summing all data points per particle, or integrating under the signal peak, yielded both accurate and precise isotope ratios within the particle population. Particles were also sampled off a solid substrate via microextraction, and isotope ratios were determined with relative differences of 0.13% to 9%. This demonstrates the ability to use spMC-ICP-MS to obtain isotope ratios on particles, with little to no relative difference in comparison to the expected ratio, even when operating Faraday detectors at fast 50 ms integration times.

Szakas, Sarah E. [Oak Ridge National Laboratory (O↗

Accurate prediction of core-level spectra of radicals at density functional theory cost via square gradient minimization and recoupling of mixed configurations

State-specific orbital optimized approaches are more accurate at predicting core-level spectra than traditional linear-response protocols, but their utility had been restricted due to the risk of "variational collapse" down to the ground state. We employ the recently developed square gradient minimization algorithm to reliably avoid variational collapse and study the effectiveness of orbital optimized density functional theory (DFT) at predicting second period element 1s core-level spectra of open-shell systems. Several density functionals (including SCAN, B3LYP, and ωB97X-D3) are found to predict excitation energies from the core to singly occupied levels with high accuracy (≤0.3 eV RMS error) against available experimental data. Higher excited states are, however, more challenging by virtue of being intrinsically multiconfigurational. We thus present a configuration interaction inspired route to self-consistently recouple single determinant mixed configurations obtained from DFT, in order to obtain approximate doublet states. This recoupling scheme is used to predict the C K-edge spectra of the allyl radical, the O K-edge spectra of CO + , and the N K-edge of NO 2 with high accuracy relative to experiment, indicating substantial promise in using this approach for the computation of core-level spectra for doublet species [vs more traditional time dependent DFT, equation of motion coupled cluster singles and doubles (EOM-CCSD), or using unrecoupled mixed configurations]. Finally, we also present general guidelines for computing core-excited states from orbital optimized DFT.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elaborated thermochemical treatment of HF, CO, N 2 , and H 2 O: Insight into HEAT and its extensions

Here, empirical, highly accurate non-relativistic electronic total atomization energies (eTAEs) are established by combining experimental or computationally converged treatments of the nuclear motion and relativistic contributions with the total atomization energies of HF, CO, N 2 , and H 2 O obtained from the Active Thermochemical Tables. These eTAEs, which have estimated (2σ) uncertainties of less than 10 cm -1 (0.12 kJ mol -1 ), form the basis for an analysis of high-level ab initio quantum chemical calculations that aim at reproducing these eTAEs for the title molecules. The results are then employed to analyze the performance of the high-accuracy extrapolated ab initio thermochemistry, or High-Accuracy Extrapolated Ab Initio Thermochemistry (HEAT), family of theoretical methods. The method known as HEAT-345(Q), in particular, is found to benefit from fortuitous error cancellation between its treatment of the zero-point energy, extrapolation errors in the Hartree-Fock and coupled cluster contributions, neglect of post-(T) core-correlation, and the basis-set error involved in higher-level correlation corrections. In addition to shedding light on a longstanding curiosity of the HEAT protocol—where the cheapest HEAT-345(Q) performs comparably to the theoretically more complete HEAT-456QP procedure—this study lays the foundation for extended HEAT variants that offer substantial improvements in accuracy relative to the established approaches.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deep Learning for Multigroup Cross-Section Representation in Two-Step Core Calculations

Here we investigate using deep learning, a type of machine-learning algorithm employing multiple layers of artificial neurons, for the mathematical representation of multigroup cross sections for use in the Griffin reactor multiphysics code for two-step deterministic neutronics calculations. A three-dimensional fuel element typical of a high-temperature gas reactor as well as a two-dimensional sodium-cooled fast reactor lattice are modeled using the Serpent Monte Carlo code, and multigroup macroscopic cross sections are generated for various state parameters to produce a training data set and a separate validation data set. A fully connected, feedforward neural network is trained using the open-source PyTorch machine-learning framework, and its accuracy is compared against the standard piecewise linear interpolation model. Additionally, we provide in this work a generic technique for propagating the cross-section model errors up to the k eff using sensitivity coefficients with the first-order uncertainty propagation rule. Quantifying the eigenvalue error due to the cross-section regression errors is especially practical for appropriately selecting the mathematical representation of the cross sections. We demonstrate that the artificial neural network model produces lower errors and therefore enables better accuracy relative to the piecewise linear model when the cross sections exhibit nonlinear dependencies; especially when a coarse grid is employed, where the errors can be halved by the artificial neural network. However, for linearly dependent multigroup cross sections as found for the sodium-cooled fast reactor case, a simpler linear regression outperforms deeper networks.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

NEAR: Neural Embeddings for Amino acid Relationships

Protein language models (PLMs) have recently demonstrated potential to supplant classical protein database search methods based on sequence alignment, but are slower than common alignment-based tools and appear to be prone to a high rate of false labeling. Here, we present NEAR, a method based on neural representation learning that is designed to improve both speed and accuracy of search for likely homologs in a large protein sequence database. NEAR’s ResNet embedding model is trained using contrastive learning guided by trusted sequence alignments. It computes per-residue embeddings for target and query protein sequences, and identifies alignment candidates with a pipeline consisting of residue-level k-NN search and a simple neighbor aggregation scheme. Tests on a benchmark consisting of trusted remote homologs and randomly shuffled decoy sequences reveal that NEAR substantially improves accuracy relative to state-of-the-art PLMs, with lower memory requirements and faster embedding and search speed. While these results suggest that the NEAR model may be useful for standalone homology detection with increased sensitivity over standard alignment-based methods, in this manuscript we focus on a more straightforward analysis of the model’s value as a high-speed pre-filter for sensitive annotation. In that context, NEAR is at least 5x faster than the pre-filter currently used in the widely-used profile hidden Markov model (pHMM) search tool HMMER3, and also outperforms the pre-filter used in our fast pHMM tool, nail.

59 BASIC BIOLOGICAL SCIENCES↗

Frequency shifts in the electron paramagnetic resonance spectrum of 39 K due to spin-exchange collisions with polarized 3 He and precise 3 He polarimetry

The Zeeman splittings and electron paramagnetic resonance frequencies of alkali-metal atoms are shifted in the presence of a polarized noble gas. For a spherical geometry, the shift is enhanced over what is expected classically by a dimensionless atomic parameter 𝜅 0 that is unique to each alkali-metal-atom–noble-gas pair. Here, we present a precise measurement of 𝜅 0 for the 39 K − 3 He system with a relative accuracy of better than 1%. A critical component of achieving subpercent accuracy involved characterizing the shape of our samples using both MRI and CT medical-imaging techniques. The parameter 𝜅 0 plays an important role in establishing the absolute polarization of 3 He in a variety of contexts, including polarized targets for electron-scattering experiments and MRI of the gas space of the lungs. Our measurement more than doubles the accuracy possible when using 𝜅 0 for polarimetry purposes. Just as important, the work presented here represents a direct measurement of 𝜅 0 for the 39 K − 3 He system; previous values for 𝜅 0 in the 39 K − 3 He system relied on a chain of measurements that were benchmarked by previous measurements of 𝜅 0 in the Rb- 3 He system.

Zeeman effect↗

Fully thermal meta-GGA exchange correlation free-energy density functional

The application of density functional theory to materials in the warm dense matter regime has motivated the development of exchange-correlation functionals which incorporate proper, explicit temperature dependence. Previous work has yielded fully-thermal exchange-correlation free energy functionals at the local density approximation (LDA) and generalized gradient approximation (GGA) levels of refinement. Recently an additive thermal correction scheme was utilized to construct a meta-GGA exchange-correlation (XC) functional in which thermal effects are treated at the GGA level. Here, the f TSCAN free-energy XC functional presented here includes thermal effects through the meta-GGA level in the context of the SCAN (strongly constrained and appropriately normed) ground-state functional. The f TSCAN functional provides generality while achieving similar performance to a thermal GGA functional at high temperatures, e.g. pressures within 1% of path integral Monte Carlo simulations of warm dense hydrogen, and a significant improvement over ground-state functionals. At low temperatures, f TSCAN demonstrates improvements in accuracy relative to lower-level and deorbitalized functionals, indicating that calculations using f TSCAN may be expected to perform well across experimentally relevant densities and pressures.

36 MATERIALS SCIENCE↗

Comparative Study of Data-Driven Area Inertia Estimation Approaches on WECC Power Systems

With the increasing integration of inverter-based resources into the power grid, there has been a notable reduction in system inertia, potentially compromising frequency stability. To assess the suitability of existing area inertia estimation techniques for real-world power systems, this paper presents a rigorous comparative analysis of system identification, measurement reconstruction, and electromechanical oscillation-based area inertia estimation methodologies, specifically applied to the large-scale and multi-area WECC 240-bus power system. Comprehensive results show that the system identification-based approach exhibits superior robustness and accuracy relative to its counterparts.

area inertia estimation↗

Surrogate Distributed Radiological Sources—Part II: Aerial Measurement Campaign

In this second part of a multipaper series, we present results from outdoor aerial measurements of surrogate distributed gamma-ray sources. Here we detail the design, manufacture, and testing of 300 individual ~7 mCi Cu-64 sealed sources at the Washington State University (WSU) research reactor and their deployment in various source patterns (each comprising up to 100 point sources) during the aerial measurement campaign. We show the results of two such measurements, in which approximate source shapes and qualitative source intensities can be seen from the count rate versus position plots, even without performing reconstructions. We also detail our efforts in ground-truthing the deployed sources and comparing measured gamma-ray data to model predictions. In particular, we compare measured versus expected count data using the Poisson deviance formalism of Part I to evaluate whether the fielded surrogate point-source arrays “look like” their truly continuous distributed source analogs. More generally, we find that the point-source array technique provides high source placement accuracy, relative ease of quantifying the true source configuration, scalability to source dimensions of ≲100 m, ease of reconfiguration and removal, and relatively low dose to personnel. Finally, we consider potential improvements and generalizations of the point-source array technique for future measurement campaigns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Fidelity Numerical Wave Tank Verification & Validation Study: Wave Generation Through Paddle Motion: Preprint

This paper presents a numerical benchmark study of wave propagation due to a paddle motion using different high-fidelity numerical models, which are capable of replicating the nearly actual physical wave tank testing. A full time series of the measured wave generation paddle motion which was used to generate wave propagation in the physical wave tank will be utilized in each of the models contributed by IEA OES Task 10's participants, which includes both computational fluid dynamics (CFD) and smooth hydrodynamic particle (SPH). The high-fidelity simulations of the physical wave testcase will allow for the evaluation of the initial transient effects from wave ramp-up and its evolution in the wave tank over time for two representative regular waves with varying levels of nonlinearity. A couple of interesting metrics like the predicted wave surface elevation at select wave probes, wave period, and phase-shift in time will be assessed to evaluate the relative accuracy of numerical models versus experimental data within specified time intervals. These models will serve as a guide for modelers in the wave energy community and provide a base case to allow further and more detailed numerical modeling of the fixed Kramer Sphere Cases under wave excitation force wave tank testing.

HYDRO ENERGY,TIDAL AND WAVE POWER↗

EcoBOT: an AI/ML enabled automated phenotyping capability for model plants

Introduction: Advances in automation and AI/ML offer new opportunities for plant science, including design, modeling, and analysis. This study aimed to develop an automated platform for researching small model plants under axenic conditions and integrate it with AI/ML tools. Methods: The EcoBOT platform was developed, which consists of sterile containers (EcoFABs) for growing plants and imaging for monitoring plant growth and health. Brachypodium distachyon was grown on the EcoBOT, and its response to nutrient limitation and copper stress was evaluated. Results: The results showed that Brachypodium distachyon grown in the EcoBOT maintained sterility and responded to nutrient limitation and copper stress. Analysis of over 6,500 root and shoot images revealed varying sensitivity and response rates to copper. Bayesian Optimization was used to improve model accuracies relating copper concentrations to plant biomass via sequential experiments, resulting in a >30% improvement. Discussion: The findings of this study demonstrate the potential of the EcoBOT platform for researching plant responses to environmental factors. Future experiments could focus on relating other chemical stresses and microbial interactions to create generalized models of plant responses.

AI image analysis↗

Ocean Energy Systems Wave Energy Modeling Task 10.4: Numerical Modeling of a Fixed Oscillating Water Column

This paper reports on an ongoing international effort to establish guidelines for numerical modeling of wave energy converters, initiated by the International Energy Agency Technology Collaboration Program for Ocean Energy Systems. Initial results for point absorbers were presented in previous work, and here we present results for a breakwater-mounted Oscillating Water Column (OWC) device. The experimental model is at scale 1:4 relative to a full-scale installation in a water depth of 12.8 m. The power-extracting air turbine is modeled by an orifice plate of 1–2% of the internal chamber surface area. Measurements of chamber surface elevation, air flow through the orifice, and pressure difference across the orifice are compared with numerical calculations using both weakly-nonlinear potential flow theory and computational fluid dynamics. Both compressible- and incompressible-flow models are considered, and the effects of air compressibility are found to have a significant influence on the motion of the internal chamber surface. Recommendations are made for reducing uncertainties in future experimental campaigns, which are critical to enable firm conclusions to be drawn about the relative accuracy of the numerical models. It is well-known that boundary element method solutions of the linear potential flow problem (e.g., WAMIT) are singular at infinite frequency when panels are placed directly on the free surface. This is problematic for time-domain solutions where the value of the added mass matrix at infinite frequency is critical, especially for OWC chambers, which are modeled by zero-mass elements on the free surface. A straightforward rational procedure is described to replace ad-hoc solutions to this problem that have been proposed in the literature.

16 TIDAL AND WAVE POWER↗

DETERMINATION OF EMISSIVITY OF MATERIALS.

During the third quarter of the contractual year of Contract NASW-104 for the determination of emissivity of materials, the emittance of nine specimens was measured at temperatures ranging up to 2200F and at pressures averaging 10(exp -8) mm Hg. The materials tested included columbium, columbium with an oxidized surface, molybdenum, graphite varnish on Type 310 stainless steel, stainless steel with an oxidized surface, and platinum black. In the spectral emittance rig, spectral as well as total emittance was measured on three specimens and total emittance only was measured on a fourth. In the total emittance rig, total emittance data was obtained on five specimens. Two of the specimens were endured. Investigations were made concerning the operational characteristics of both rigs in order to eliminate possible sources of error in the data. On the spectral emittance rig, tests were conducted to determine the exact magnitude of any error introduced in the spectral emittance values by beam intermixing resulting from imperfections in the optical system. On the total emittance rig, work was concentrated on the determination of the relative accuracy of the chromel-alumel and platinum-platinum 10% rhodium thermocouples used to measure the temperature of the specimen.

Emission↗

Estimating sensitivity of vacuum gages

Gage sensitivity for a particular gas is estimated using the known performance of the gage with a reference gas /nitrogen/ and employing several empirical rules which have usable accuracy. Relative gage sensitivities have been estimated for over 100 gases and vapors.

Summers, R. L.↗

Radar pulse compression and high resolution sea reflectivity

The state-of-the-art in radar pulse compression as it applies to spacecraft altimetry is summarized. It is illustrated how in the next few years vertical resolutions to 0.5 to 2.0 ft. can be obtained with relative accuracies of 5 to 10% of these values if the nature of the sea surface is known. Data are also given that show when high accuracy is desired, second order effects such as the asymmetries in the sea surface reflectivity may be taken into account.

Nathanson, F. E.↗

A three-station lightning detection system

A three-station network is described which senses magnetic and electric fields of lightning. Directional and distance information derived from the data are used to redundantly determine lightning position. This redundancy is used to correct consistent propagation errors. A comparison is made of the relative accuracy of VLF direction finders with a newer method to determine distance to and location of lightning by the ratio of magnetic-to-electric field as observed at 400 Hz. It was found that VLF direction finders can determine lightning positions with only one-half the accuracy of the method that uses the ratio of magnetic-to-electric field.

Ruhnke, L. H.↗

Error analysis for station position from tracking of the Lageos satellite

The earth physics satellite systems error analysis program was applied to the problem of predicting the relative accuracy of station position determinations under varying orbital and observing geometries. The reference case consists of nine ground stations extending over 1500 km which lasers ranged to a LAGEOS satellite, with simultaneous Doppler tracking from a geosynchronous satellite for 16 days. Eleven variations from the reference case were tested. The results showed little sensitivity to whether the LAGEOS altitude is 3700 or 5690 km. More significant were the high inclination, and that LAGEOS was tracked by a geosynchronous satellite.

Parmenter, M. E.↗