Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Regression model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Bayesian Statistical Models for Community Annoyance Survey Data

This paper demonstrates the use of two Bayesian statistical models to analyze single-event sonic boom exposure and human annoyance data from community response surveys. Each model is fit to data from a NASA pilot study.Unlike many community noise surveys, this study used a panel sample to collect multiple observations per participant instead of a single observation. Thus, a multilevel (also known as hierarchical or mixed-effects) model is used to account for the within-subject correlation in the panel sample data. This paper describes a multilevel logistic regression model and a multilevel ordinal regression model. The paper also proposes a method for calculating a summary dose-response curve from the multilevel models that represents the population. The two models’ summary dose-response curves are visually similar. However, their estimates differ when calculating the noise dose at a fixed percent highly annoyed.

Musical instruments↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Event-Based Energy Impact Tracking and Forecasting with Limited Measurements for Rooftop Units

Packaged air conditioning units and heat pumps, also known as rooftop units (RTUs), are responsible for almost 133 billion kWh of electricity usage annually on site for space cooling U.S. commercial buildings. In addition, the use of heat pumps is a trend we expect to accelerate as buildings transition from fossil fuel-based heating to electricity as a key step for decarbonizing the U.S. commercial buildings sector. However, the operation conditions and energy use of RTUs and heat pumps are usually not well monitored as they are not commonly integrated with building automation systems and lack exposed sensing and control points. To fill this gap, this paper proposes a framework for tracking and forecasting energy impacts resulting from degradation of performance and improved performance for unit servicing using limited data. The proposed framework makes use of a constrained dataset, specifically measurements of the outdoor air temperature and the power demand of individual RTUs, to track and forecast changes in energy use associated with changes in performance over various temporal horizons ranging from days to weeks. Following the detection of an RTU fault, performance degradation, or performance improvement, the framework employs a prediction model to assess the cumulative energy impact. We demonstrate the effectiveness of the method with field-collected data for servicing and degradation examples and compare the predicting accuracy of Gradient Boosting Decision Tree (GBDT) Regression models to Support Vector Regression and Linear Regression models. The results show that GBDT achieved the best accuracy for time-series validation datasets for the servicing and degradation cases, and the prediction model was able to track the cumulative energy impacts of events. The proposed framework can inform building owners of the cumulative change in energy usage of RTUs associated with performance degradation, performance improvement, or a fault.

packaged air conditioners, packaged heat pumps, ro↗

Fusion of Experiments and Simulations for Real-Time Identification of Pipeline Defects

In this study, we explored fusion of experiments and simulations for real time identification of pipeline defects across physical and non-physical domains. The challenges associated to data processing were addressed and a combined classification models was presented via CNN models. In addition, regression model based on XGBOOST is built to determine the defect location and defect dimension from data-driven features of guided wave signals captured by SMS fiber optic sensor.

deep learning↗

Fusion of Experiments and Simulations for Real-Time Identification of Pipeline Defects

In this study, we explored fusion of experiments and simulations for real time identification of pipeline defects across physical and non-physical domains. The challenges associated to data processing were addressed and a combined classification models was presented via CNN models. In addition, regression model based on XGBOOST is built to determine the defect location and defect dimension from data-driven features of guided wave signals captured by SMS fiber optic sensor.

deep learning↗

Summary and Annotated Bibliography of Measurement Error Corrections with Potential Application in Future Quesst Mission Community Noise Studies

This document is motivated by likely needs of the Quesst mission community response tests, which will culminate in data collection and estimation of dose-response regression relationships for consideration by domestic and international aviation regulators. Furthermore, basic research questions evaluating interactions between rates of community annoyance, dose levels, and indicators of the presence of rattle, vibration, and startle hinge on hypothesis testing in the context of regression models. For a variety of reasons, noise doses may be known only imprecisely and may not reflect the actual level experienced by responding subjects. These differences between true dose and estimated dose, be they systematic or random, constitute covariate measurement error. Available statistics literature speaks to the impacts of measurement error on regression models, both in terms of bias in estimated coefficients and predicted values, and in terms of the loss of statistical power for hypothesis testing. Given the particulars of a categorical annoyance response variable and a continuous noise dose predictor variable subject to measurement error during testing, the emphasis of this report is on findings and methods pertinent to generalized linear (and mixed) models likely to be employed during the Quesst mission community tests. We reach the following conclusions: 1. Of four reviewed methods, structural Bayesian measurement error models and simulation extrapolation (SIMEX) may be the most readily applicable to Quesst mission community noise study objectives. 2. If warranted, a linear measurement model can help model systematic sources of measurement error that the classical measurement error does not. 3. For its ready implementation and small additional input requirements, simulation extrapolation may be ideally suited for addressing secondary research questions involving interactions between annoyance, noise dose, and other factors through hypothesis testing. 4. For their flexibility and ability to propagate uncertainty, structural Bayesian hierarchical models have great appeal for mission purposes; some care may be needed in developing appropriate probability models describing actual noise exposure during testing. An annotated bibliography logs additional papers and resources that may be of value to analysts in other projects and disciplines.

Dose-Response Model↗

Five-Hole Flow Angle Probe Calibration for the NASA Glenn Icing Research Tunnel

A spring 1997 test section calibration program is scheduled for the NASA Glenn Research Center Icing Research Tunnel following the installation of new water injecting spray bars. A set of new five-hole flow angle pressure probes was fabricated to properly calibrate the test section for total pressure, static pressure, and flow angle. The probes have nine pressure ports: five total pressure ports on a hemispherical head and four static pressure ports located 14.7 diameters downstream of the head. The probes were calibrated in the NASA Glenn 3.5-in.-diameter free-jet calibration facility. After completing calibration data acquisition for two probes, two data prediction models were evaluated. Prediction errors from a linear discrete model proved to be no worse than those from a full third-order multiple regression model. The linear discrete model only required calibration data acquisition according to an abridged test matrix, thus saving considerable time and financial resources over the multiple regression model that required calibration data acquisition according to a more extensive test matrix. Uncertainties in calibration coefficients and predicted values of flow angle, total pressure, static pressure. Mach number. and velocity were examined. These uncertainties consider the instrumentation that will be available in the Icing Research Tunnel for future test section calibration testing.

Gonsalez, Jose C.↗

Speedup of UEDGE Parameter Scans Using Machine-Learning Optimized OpenMP Parallelization and a Continuation Solver

This article presents the OpenMP parallelization of the preconditioning Jacobian assembly and right‐hand side residual evaluation in UEDGE. A continuation algorithm, utilizing the internal NKSOL implicit Jacobian‐Free Newton‐Krylov solver to efficiently scan physical parameters, is also presented. The implemented parallelization reduces the computational time for a benchmark scan run on 32 threads by compared to the serial version when using trained random forest regression models to identify the optimal decomposition of the system of equations. Random forest regression models applied to the UEDGE time‐dependent and continuation solver algorithms did not yield meaningful improvement in computational performance. A benchmark DIII‐D gas injection rate scan in the 0.35–0.75 kA interval, performed on a test cluster using the parallelized code and continuation solver, produced 1066 steady‐state solutions with a 22 s average wall‐clock computational time per steady‐state solution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Method for Calculating the Probability of Successfully Completing a Rocket Propulsion Ground Test

Propulsion ground test facilities face the daily challenges of scheduling multiple customers into limited facility space and successfully completing their propulsion test projects. Due to budgetary and schedule constraints, NASA and industry customers are pushing to test more components, for less money, in a shorter period of time. As these new rocket engine component test programs are undertaken, the lack of technology maturity in the test articles, combined with pushing the test facilities capabilities to their limits, tends to lead to an increase in facility breakdowns and unsuccessful tests. Over the last five years Stennis Space Center's propulsion test facilities have performed hundreds of tests, collected thousands of seconds of test data, and broken numerous test facility and test article parts. While various initiatives have been implemented to provide better propulsion test techniques and improve the quality, reliability, and maintainability of goods and parts used in the propulsion test facilities, unexpected failures during testing still occur quite regularly due to the harsh environment in which the propulsion test facilities operate. Previous attempts at modeling the lifecycle of a propulsion component test project have met with little success. Each of the attempts suffered form incomplete or inconsistent data on which to base the models. By focusing on the actual test phase of the tests project rather than the formulation, design or construction phases of the test project, the quality and quantity of available data increases dramatically. A logistic regression model has been developed form the data collected over the last five years, allowing the probability of successfully completing a rocket propulsion component test to be calculated. A logistic regression model is a mathematical modeling approach that can be used to describe the relationship of several independent predictor variables X(sub 1), X(sub 2),..,X(sub k) to a binary or dichotomous dependent variable Y, where Y can only be one of two possible outcomes, in this case Success or Failure. Logistic regression has primarily been used in the fields of epidemiology and biomedical research, but lends itself to many other applications. As indicated the use of logistic regression is not new, however, modeling propulsion ground test facilities using logistic regression is both a new and unique application of the statistical technique. Results from the models provide project managers with insight and confidence into the affectivity of rocket engine component ground test projects. The initial success in modeling rocket propulsion ground test projects clears the way for more complex models to be developed in this area.

Messer, Bradley P.↗

Predicting Damages to Remainder Parcels in Right-of-Way Acquisitions for Expanding Transportation Infrastructure: Using a Truncated Finite-Mixture Model

Right-of-way acquisition is a critical component of transportation infrastructure development. Transportation infrastructure projects cannot proceed without proper right-of-way acquisition or may face significant delays. State Departments of Transportation frequently acquire parcels of land for roadway expansion projects. A majority of these acquisitions can be partial takings, referring to a portion of a parcel that is acquired. The remainder of the property usually suffers economic changes due to the partial acquisition, which can be calculated as damage percentages. The damage percentage represents the extent to which the remaining land or property value has been diminished due to the acquisition. It reflects the remaining property value percentage that may have been lost or compromised due to the acquisition. Here, this study aims to provide a robust model to estimate damage percentages to the remainder parcels that may help state Departments of Transportation appraisers make early predictions about the damages in cases involving partial takings. The research uses 509 appraisal reports from the Tennessee Department of Transportation to identify the key parcel attributes that influence the percentage of damages. Three regression models are developed: a linear regression model, a finite-mixture model (FMM), and a truncated FMM with two latent classes. The modeling results show that the truncated FMM with two classes outperforms the other models. To validate the models, actual sales data is collected and analyzed for 59 properties, and the results suggest that the model predictions are fairly accurate. A predictive tool is developed based on the models to help appraisers anticipate right-of-way damages under different scenarios and can provide early predictions about the damages.

42 ENGINEERING↗

RxnRover/amlro

AMLRO (Active Machine Learning Reaction Optimizer) is an open-source framework designed to accelerate chemical reaction optimization using active learning with classical machine learning regression models. AMLRO integrates space-filling sampling strategies (e.g., Sobol and Latin Hypercube sampling) with iterative model training, prediction, and experiment selection to efficiently navigate complex reaction spaces. The platform supports multiple regression models, flexible multi-objective definitions, and user-defined parameter bounds, enabling data-efficient optimization from small initial datasets. AMLRO is designed for ease of use by experimentalists and can operate as a standalone decision-support tool or be integrated into closed-loop automated experimentation workflows.

Kulathunga, Dulitha Prasanna [Iowa State Universit↗

Spectral estimation of green leaf area index of oats

Green leaf area index (LAI) is a measure of vegetative growth and development and is frequently used as an input parameter in yield estimation and evapotranspiration models. Extensive destructive sampling is usually required to achieve accurate estimates of green LAI in natural situations. In this investigation, a statistical modeling approach was used to predict the green LAI of oats from bidirectional reflectance data collected with multiband radiometers. Stepwise multiple regression models based on two sets of spectral reflectance factors accounted for 73 percent and 65 percent of the variance in green LAI of oats. Exponential models of spectral data transformations of greenness, normalized difference, and near-infrared/red ratio accounted for more of the variance in green LAI than the multiple regression models.

Best, R. G.↗

The Efficacy of Seasonal Terrestrial Water Storage Forecasts for Predicting Vegetation Activity Over Africa

Terrestrial water storage (TWS) provides important information on terrestrial hydroclimate and may have value for seasonal forecasting because of its strong persistence. We use the NASA Hydrological Forecast and Analysis System (NHyFAS) to investigate TWS forecast skill over Africa and assess its value for predicting vegetation activity from satellite estimates of leaf area index (LAI). Forecast skill is high over East and Southern Africa, extending up to 3–6 months in some cases, with more modest skill over West Africa. Highest skill generally occurs during the dry season or beginning of the wet season when TWS anomalies from the previous wet season are most likely to carry forward in time. In East Africa, this occurs prior to and during the transition into the spring “Long Rains” from January–March, while in Southern Africa this period of highest skill starts at the beginning of the dry season in April and extends through to the start of the wet season in October. TWS is highly and positively correlated with LAI, and a logistic regression model shows high cross-validation skill in predicting above or below normal LAI using TWS. Combining the LAI regression model with the NHyFAS forecasts, 1-month lead LAI predictions have high accuracy over East and Southern Africa, with reduced but significant skill at 3-month leads over smaller sub-regions. This highlights the potential value of TWS as an additional source of information for seasonal forecasts over Africa, with direct applications to some of the most vulnerable agricultural regions on the continent.

Terrestrial water shortage↗

Soil Salinity Level Assessment and Prediction Integrating UAV-borne Hyperspectral Imaging and Machine Learning Algorithms to Combat Desertification

In response to the ongoing global food crisis, the United Nations has identified “Zero Hunger” as one of its Sustainable Development Goals. A central contributor to the crisis is the process in which agricultural lands go through desertification. Research has shown a direct correlation between soil salinity and desertification - increased salinity levels indicate a higher risk for desertification. Furthermore, researchers have explored various techniques to map soil salinity, but these methods are oftentimes inefficient and don’t address future salinity predictions. To improve desertification monitoring, soil salinity can be observed via hyperspectral imaging on unmanned aerial vehicles (UAVs) to predict the risk of agricultural desertification using artificial intelligence (AI) and machine learning (ML) techniques. A significant gap exists in past research that applies ML and imaging techniques to soil salinity: convolutional neural networks (CNNs) and regression models are rarely leveraged together, despite the efficiency and accuracy of these models. To compensate for this gap, the proposed system leverages the use of these AI and ML models to improve soil assessment and prediction techniques. This approach involves three steps - data collection, image analysis, and future prediction. Using hyperspectral cameras on UAVs to collect the data from the region, a trained CNN model will output estimated soil salinity levels at a specific time. The estimations will then be analyzed by a regression model to assess the accuracy of future soil salinity predictions. The proposed system will identify regions at risk of desertification to help farmers mitigate agricultural loss, in turn helping alleviate the food crisis.

UAV systems↗

New Approach for the Assessment of Interactions of a Strain-Gage Balance

A new approach was developed to assess interactions of a strain-gage balance. The approach compares interactions observed during a calibration of the balance with interactions observed during the application of check loads. The approach assumes that alignment errors of the calibration loads are negligible. In that case, interactions observed during the calibration can be used as a reference for the assessment of interactions of check loads. The new approach first fits interactions of a single-component load of the calibration data using simple regression models. Then, interactions of the check loads are predicted by using the check load values as inputs for the regression models of the interactions. In the next step, absolute values of differences between predicted and observed interactions of the check loads are computed. Afterwards, the largest differences are compared with empirical thresholds to assess how well the interactions of the check load data agree with the interactions of the calibration data. Recently obtained data sets of a six-component force balance are used to illustrate the application of the new approach. It is also demonstrated how knowledge of balance design characteristics can benefit the assessment of interactions.

wind tunnel test↗

Influence of Primary Gage Sensitivities on the Convergence of Balance Load Iterations

The connection between the convergence of wind tunnel balance load iterations and the existence of the primary gage sensitivities of a balance is discussed. First, basic elements of two load iteration equations that the iterative method uses in combination with results of a calibration data analysis for the prediction of balance loads are reviewed. Then, the connection between the primary gage sensitivities, the load format, the gage output format, and the convergence characteristics of the load iteration equation choices is investigated. A new criterion is also introduced that may be used to objectively determine if the primary gage sensitivity of a balance gage exists. Then, it is shown that both load iteration equations will converge as long as a suitable regression model is used for the analysis of the balance calibration data, the combined influence of non linear terms of the regression model is very small, and the primary gage sensitivities of all balance gages exist. The last requirement is fulfilled, e.g., if force balance calibration data is analyzed in force balance format. Finally, it is demonstrated that only one of the two load iteration equation choices, i.e., the iteration equation used by the primary load iteration method, converges if one or more primary gage sensitivities are missing. This situation may occur, e.g., if force balance calibration data is analyzed in direct read format using the original gage outputs. Data from the calibration of a six component force balance is used to illustrate the connection between the convergence of the load iteration equation choices and the existence of the primary gage sensitivities.

Ulbrich, Norbert Manfred↗

Regression Analysis and Calibration Recommendations for the Characterization of Balance Temperature Effects

Analysis and use of temperature-dependent wind tunnel strain-gage balance calibration data are discussed in the paper. First, three different methods are presented and compared that may be used to process temperature-dependent strain-gage balance data. The first method uses an extended set of independent variables in order to process the data and predict balance loads. The second method applies an extended load iteration equation during the analysis of balance calibration data. The third method uses temperature-dependent sensitivities for the data analysis. Physical interpretations of the most important temperature-dependent regression model terms are provided that relate temperature compensation imperfections and the temperature-dependent nature of the gage factor to sets of regression model terms. Finally, balance calibration recommendations are listed so that temperature-dependent calibration data can be obtained and successfully processed using the reviewed analysis methods.

wind tunnel test↗