Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Organic contamination detection for isotopic analysis of water by laser spectroscopy

Hydrogen and oxygen stable isotope ratios (δ 2 H, δ 17 O, and δ 18 O values) are commonly used tracers of water. These ratios can be measured by isotope ratio infrared spectroscopy (IRIS). However, IRIS approaches are prone to errors induced by organic compounds present in plant, soil, and natural water samples. A novel approach using 17 O-excess values has shown promise for flagging spectrally contaminated plant samples during IRIS analysis. A systematic assessment of this flagging system is needed to prove it useful. Errors induced by methanol and ethanol water mixtures on measured IRIS and isotope ratio mass spectrometry (IRMS) results were evaluated. For IRIS analyses both liquid- and vapour-mode (via direct vapour equilibration) methods are used. The δ 2 H, δ 17 O, and δ 18 O values were measured and compared with known reference values to determine the errors induced by methanol and ethanol contamination. In addition, the 17 O-excess contamination detection approach was tested. This is a post-processing detection tool for both liquid and vapour IRIS triple-isotope analyses, utilizing calculated 17 O-excess values to flag contaminated samples. Organic contamination induced significant errors in IRIS results, not seen in IRMS results. Methanol caused larger errors than ethanol. Results from vapour-IRIS analyses had larger errors than those from liquid-IRIS analyses. The 17 O-excess approach identified methanol driven error in liquid- and vapour-mode IRIS samples at levels where isotope results became unacceptably erroneous. For ethanol contaminated samples, a mix of erroneous and correct flagging occurred with the 17 O-excess method. Here our results indicate that methanol is the more problematic contaminant for data corruption. The 17 O-excess method was therefore useful for data quality control. Organic contamination caused significant errors in IRIS stable isotope results. These errors were larger during vapour analyses than during liquid IRIS analyses, and larger for methanol than ethanol contamination. The 17 O-excess method is highly sensitive for detecting narrowband (methanol) contamination error in vapour and liquid analysis modes in IRIS.

60 APPLIED LIFE SCIENCES↗

Subjective, physiological, and performance measures of eight primary flight displays

A simulator study to determine the effect on pilot performance of electronically represented altitude and airspeed information on the primary flight display using moving tape formats is presented. The study used a seemingly random, unpredictable guidance task and focused on three areas relating to the representation of information on moving tape formats: tape centering, trend information, and tape orientation. Results suggest that moving tape displays with actual values centered is better than tapes with reference values centered and that high-to-low airspeed tape orientation is better than low-to-high orientation. With trend information absent, subjects devoted 50 percent more attention to the secondary task relative to display configurations with trend presented.

Abbott, Terence↗

Black carbon emissions in Russia: A critical review

Russia has a particularly important role regarding black carbon (BC) emissions given the extent of its territory above the Arctic Circle, where BC emissions have a particularly pronounced effect on the climate. This study presents a comprehensive review of BC estimates from a range of studies. We assess underlying methodologies and data sources for each major emissions source based on their level of detail, accuracy and extent to which they represent current conditions. We then present reference values for each major emissions source. In the case of flaring, the study presents new estimates drawing on data on Russian associated petroleum gas and the most recent satellite data on flaring. We also present estimates of organic carbon (OC) for each source, either based on the reference studies or from our own calculations. In addition, the study provides uncertainty estimates for each source. Total BC emissions are estimated at 689 Gg in 2014, with an uncertainty range between (407-1,416), while OC emissions are 9,228 Gg (with uncertainty between 5,595 and 14,728). Wildfires dominated and contributed about 83% of the total BC emissions, however the effect on radiative forcing is mitigated by OC emissions. We also present an adjusted estimate of Arctic forcing from Russian OC and BC emissions. In recent years, Russia has pursued policies to reduce flaring and limit particulate emissions from on-road transport, both of which appear to significantly contribute to the lower emissions and forcing values found in this study.

Black carbon↗

Two experimental approaches in nuclear astrophysics using neutrons

High resolution measurements using the ({sup 3}He,n) reaction are used to determine excitation energies of astrophysically important states. Further, spins can be assigned to these states by comparing the measured differential cross sections to Hauser-Feshbach cross sections. The astrophysical reaction rates are then calculated using the experimental values. Reference [1] is an example of such measurements.Absolute values of the astrophysical S factors and cross sections are calculated from measurements using the (d,n) reaction at low incident energies. Reference [2] is an example of such measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiation Exposure in Nonvascular Fluoroscopy-Guided Interventional Procedures

Purpose: To investigate the radiation exposure in non-vascular fluoroscopy guided interventions and to search strategies for dose reduction. Materials and Methods: Dose area product (DAP) of 638 consecutive non-vascular interventional procedures of one year were analyzed with respect to different types of interventions; gastrointestinal tract, biliary interventions, embolizations of tumors and hemorrhage. Data was analyzed with special focus on the fluoroscopy doses and frame doses. The third quartiles (Q3) of fluoroscopy dose values were defined in order to set a reference value for our in-hospital practice. Results: Mean fluoroscopy times of gastrostomy, jejunostomy, right and left sided percutaneous biliary drainage, chemoembolization of the liver and embolization due to various hemorrhages were 5.9, 8.6, 13.5, 16.6, 17.4 and 25.2 min, respectively. The respective Q3 total DAP were 52.9, 73.3, 155.1, 308.4, 428.6 and 529.3 Gy*cm{sup 2}. Overall, around 66% of the total DAP originated from the radiographic frames with only 34% of the total DAP applied by fluoroscopy (P < 0.001). The investigators experience had no significant impact on the total DAP applied, most likely since there was no stratification to intervention-complexity. Conclusion: To establish Diagnostic Reference Levels (DRLs), there is a need to establish a registry of radiation dose data for the most commonly performed procedures. Documentation of interventional procedures by fluoroscopy 'grabbing' has the potential to considerably reduce radiation dose applied and should be used instead of radiographic frames whenever possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Projector‐Based Quantum Embedding Study of Iron Complexes

Projection‐based embedding theory (PBET) is used to calculate and assess the challenging spin‐crossover energies for a selection of small Fe‐containing systems by embedding the metal center into the frozen potential of the ligands. MP2, CCSD, and CCSD(T) are embedded in potentials from the SCAN and r 2 SCAN functionals and compared with the canonical values for the constituent methods and previously reported reference values. Considering the PBET calculations as a correction for the underlying DFT, the embedding calculations are able to provided improvement for most cases. In some cases, the PBET methods are able to compensate for limitations in the wave function methods and produce results similar to more rigorous calculations from the literature. For the systems with spin‐crossover energies near zero, the current methodology fails to provide consistent improvement. In conclusion, the isolated recalculation of the electronic structure around the metal center when embedded into a DFT treatment of the ligand field shows promise as a pragmatic and lower cost treatment compared to the canonical treatment of the whole system of the difficult class of spin‐crossover complexes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Two and three-dimensional near infrared subcutaneous structure imager using realtime nonlinear video processing

A method includes placing an imaging device in contact with a sample, irradiating the sample via an illuminator such that radiation scatters off of the structure, and providing the scattered radiation to a detector to generate a digital video signal. A processor then performs various operations including subtracting a sum of a black state value and a user-defined black level clamping value from the digital video signal to create subtracted image data, substituting negative values in the subtracted image data with a reference value to create modified image data, and amplifying the modified image data by a user-defined gain to create contrast enhanced image data.

Krasowski, Michael J.↗

A subzone reconstruction algorithm for efficient staggered compatible remapping

Staggered-grid Lagrangian hydrodynamics algorithms frequently make use of subzonal discretization of state variables for the purposes of improved numerical accuracy, generality to unstructured meshes, and exact conservation of mass, momentum, and energy. For Arbitrary Lagrangian–Eulerian (ALE) methods using a geometric overlay, it is difficult to remap subzonal variables in an accurate and efficient manner due to the number of subzone–subzone intersections that must be computed. This becomes prohibitive in the case of 3D, unstructured, polyhedral meshes. A new procedure is outlined in this paper to avoid direct subzonal remapping. The new algorithm reconstructs the spatial profile of a subzonal variable using remapped zonal and nodal representations of the data. The reconstruction procedure is cast as an under-constrained optimization problem. Enforcing conservation at each zone and node on the remapped mesh provides the set of equality constraints; the objective function corresponds to a quadratic variation per subzone between the values to be reconstructed and a set of target reference values. Numerical results for various pure-remapping and hydrodynamics tests are provided. Ideas for extending the algorithm to staggered-grid radiation-hydrodynamics are discussed as well as ideas for generalizing the algorithm to include inequality constraints.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Methodology Used in the Radiological Assessment of a Coal-Fired Power Plant

A radiological assessment of the workers and the public potentially affected by the operation of the Teruel Coal-fired Power Plant (the UPT Teruel), was performed under realistic assumptions. This assessment is part of a wider study to characterize the potential radiological impact of Naturally Occurring Radioactive Materials (NORM), in which our team, integrated by University of Extremadura and CIEMAT, is carrying out the study on coal-fired power plants sponsored by the Spanish Nuclear Safety Council (CSN). The study comprises the four biggest coal-fired power plants in Spain. Taking into account the working conditions and the plant specifications, six groups of workers were defined, established considering the 17 working tasks that could be of any importance for this assessment. For the public, considering that the area is barely inhabited, two different recreational scenarios were defined. Therefore, in-plant and outside measurements, needed for the assessment of each scenario, were carried out. Where experimental data were not available or measurements ranged within the natural background radiation values, modelling has been used. Every measured or estimated activity concentration in coal and other used materials or in the by-products generated in the power plant, for every radionuclide in the natural chains of {sup 238}U, {sup 232}Th and {sup 40}K, were below 0.32 Bq g{sup -1}. Those values are under the 0.5 Bq g{sup -1} reference value for exemption and clearance of {sup 238}U, {sup 232}Th and {sup 226}Ra and the 5 Bq g{sup -1} for {sup 40}K recommended in Europe. In the dose evaluations for six groups of workers, a maximum of 21 {mu}Sv a{sup -1} was obtained (mainly due to the inhalation of resuspended particles). For both considered scenarios for the public, all the evaluated doses were below 4.3 {mu}Sv a{sup -1}. These results are considered negligible from a radiological point of view. In this work the models and assumptions used for the evaluation of workers and public doses, the assessment, as well as the most relevant experimental results and conclusions are presented.

54 ENVIRONMENTAL SCIENCES↗

Automatic Control of Arc Process for Making Carbon Nanotubes

An automatic-control system has been devised for a process in which carbon nanotubes are produced in an arc between a catalyst-filled carbon anode and a graphite cathode. The control system includes a motor-driven screw that adjusts the distance between the electrodes. The system also includes a bridge circuit that puts out a voltage proportional to the difference between (1) the actual value of potential drop across the arc and (2) a reference value between 38 and 40 V (corresponding to a current of about 100 A) at which the yield of carbon nanotubes is maximized. Utilizing the fact that the potential drop across the arc increases with the interelectrode gap, the output of the bridge circuit is fed to a motor-control circuit that causes the motor to move the anode toward or away from the cathode if the actual potential drop is more or less, respectively, than the reference potential. Thus, the system regulates the interelectrode gap to maintain the optimum potential drop. The system also includes circuitry that records the potential drop across the arc and the relative position of the anode holder as function of time.

Scott, Carl D.↗

Urinary trichloroacetic acid levels and semen quality: A hospital-based cross-sectional study in Wuhan, China

Toxicological studies indicate an association between exposure to disinfection by-products (DBPs) and impaired male reproductive health in animals. However, epidemiological evidence in humans is still limited. We conducted a hospital-based cross-sectional study to investigate the effect of exposure to DBPs on semen quality in humans. Between May 2008 and July 2008, we recruited 418 male partners in sub-fertile couples seeking infertility medical instruction or assisted reproduction services from the Tongji Hospital in Wuhan, China. Major semen parameters analyzed included sperm concentration, motility, and morphology. Exposure to DBPs was estimated by their urinary creatinine-adjusted trichloroacetic (TCAA) concentrations that were measured with the gas chromatography/electron capture detection method. We used linear regression to assess the relationship between exposure to DBPs and semen quality. According to the World Health Organization criteria (<20 million/mL for sperm concentration and <50% motile for sperm motility) and threshold value recommended by Guzick (<9% for sperm morphology), there were 265 men with all parameters at or above the reference values, 33 men below the reference sperm concentration, 151 men below the reference sperm motility, and 6 men below the reference sperm morphology. The mean (median) urinary creatinine-adjusted TCAA concentration was 9.2 (5.1) {mu}g/g creatinine. Linear regression analyses indicated no significant association of sperm concentration, sperm count, and sperm morphology with urinary TCAA levels. Compared with those in the lowest quartile of creatinine-adjusted urinary TCAA concentrations, subjects in the second and third quartiles had a decrease of 5.1% (95% CI: 0.6%, 9.7%) and 4.7% (95% CI: 0.2%, 9.2%) in percent motility, respectively. However, these associations were not significant after adjustment for age, abstinence time, and smoking status. The present study provides suggestive but inconclusive evidence of the relationship between decreased sperm motility and increased urinary TCAA levels. The effect of exposure to DBPs on human male reproductive health in Chinese populations still warrants further investigations. - Research highlights: {yields} No association between DBPs exposure and semen quality was found. {yields} Effects of DBPs exposure on male reproductive health need further investigations. {yields} Intra-individual variability of urinary TCAA should be considered in the future.

54 ENVIRONMENTAL SCIENCES↗

SU-E-T-343: Valencia Applicator Commissioning Using a Micro-Chamber Array

Purpose: In the commissioning and QA of surface isotope-based applicators, source-indexer distance (SID) has a great influence in the flatness, symmetry and output. To these purposes, methods described in the literature are the use of a special insert at the entrance of dwell chamber or radiochromic films. Here we present the experience with a micro-chamber array to perform the commissioning and QA of Valencia applicators. Methods: Valencia applicators have been used, the classic and the new extra-shielded version. A micro-chamber array has been employed, 1000 SRS (PTW), with 977 liquid filled, 2.3×2.3×0.5 mm{sup 3} sized ion chambers covering 11×11 cm{sup 2}, which spacing is 2.5 mm in the central 5.5×5.5 cm{sup 2}, dedicated mainly in principle, in conjunction with Octavius 4D (PTW), to IMRT, VMAT, SBRT verifications. Verisoft software that allows for 3D and planar analysis has been used to evaluate the results. Applicators were located on the surface of the array. To verify the SID, measurements corresponding to the reference value, SID ± 1 mm and SID ± 2 mm were acquired (integration time was fixed in order to discard the influence of the source entrance/exit). Once SID was determined, standard protocol treatments corresponding to 3 Gy and 7 Gy were acquired in order to establish typical patient dose distribution. Results: The method is fast and sensitive. The SID obtained was 1321 mm which is the nominal value included in the applicator manual. For example at 1319 mm an asymmetry of ±8% with respect to the central value was measured, along with a central deviation of −4% referred to 1321 mm. Conclusion: A practical method for the commissioning and QA of Valencia applicators has been described. It has been shown that it is an efficient and accurate tool for these purposes as well as for the verification of the absolute output constancy.

60 APPLIED LIFE SCIENCES↗

TU-C-BRE-03: Aggregation of Linac Measurement Data

Purpose: Accurate data of linear accelerator radiation characteristics is important for treatment planning system commissioning as well as regular quality assurance of the machine. The RPC has performed site visits of numerous machines . Data gathered from Varian machines from the past 15 years are presented. The data collected can be used as a secondary check or when commissioning a new machine to verify that values are reasonable. Methods: Data from the past 15 years of RPC site visits was compiled and analyzed. Data was composed from measurements from approximately 400 Varian machines. Each dataset consists of several point measurements at various locations in a water phantom to measure percentage depth dose, output factors, including small MLC fields, off-axis factors, and wedge factors if applicable. Common statistical values are presented for each machine type. Where applicable, data was compared to other reference data given by the vendor or a select number of previous researchers. Results: Data is separated by energy and parameter and then analyzed by machine class. Data distributions of the parameter data were normal except occasionally at the tails. Distributions of the data for each class and parameter are tabulated to give not simply a singular reference value, but metrics about the distribution: 5th and 95th percentile values and the standard deviation as well as the median. Conclusion: The RPC has collected numerous data on Varian linacs and presented the finding of the past 15 years. The data can be used as a reference data set for physicists to compare against. A linac that deviates from the values does not necessarily indicate there is a problem as long as the treatment planning system correlates to the machine. Comparison of linac and treatment planning system data to external reference data can prevent serious treatment errors.

07 ISOTOPE AND RADIATION SOURCES↗

Reference Data for the Density and Viscosity of Liquid Cadmium, Cobalt, Gallium, Indium, Mercury, Silicon, Thallium, and Zinc

The available experimental data for the density and viscosity of liquid cadmium, cobalt, gallium, indium, mercury, silicon, thallium, and zinc have been critically examined with the intention of establishing both a density and a viscosity standard. All experimental data have been categorized into primary and secondary data according to the quality of measurement, the technique employed and the presentation of the data, as specified by a series of criteria. The proposed standard reference correlations for the density of liquid cadmium, cobalt, gallium, indium, silicon, thallium, and zinc are characterized by percent deviations at the 95% confidence level of 0.6, 2.1, 0.4, 0.5, 2.2, 0.9, and 0.7, respectively. In the case of mercury, since density reference values already exist, no further work was carried out. The standard reference correlations for the viscosity of liquid cadmium, cobalt, gallium, indium, mercury, silicon, thallium, and zinc are characterized by percent deviations at the 95% confidence level of 9.4, 14.0, 13.5, 2.1, 7.3, 15.7, 5.1, and 9.3, respectively.

36 MATERIALS SCIENCE↗

Static and rotational output variation of a tomotherapy unit

A simple device to check the machine output in rotational mode is described. Integral and instantaneous beam output in absolute dose can be measured and analyzed in a very simple manner. A method to correlate the results with the value obtained during the machine calibration in static beam and the reference value used by the treatment planning system for dose calculation in rotation beam is also described. Using this method and device, the daily output can be performed in rotational conditions which are closer to the treatment conditions. Measurement results using this device show differences in the beam output between static and rotational delivery which have to be considered carefully during the calibration process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for Variations of {sup 213}Po Half-Life

A device with the parent {sup 229}Th source was constructed to search for variations of the daughter {sup 213}Po half-life (T{sub 1/2} = 4.2 μs). A solar-daily variation with amplitude A{sub So} = (5.3 ± 1.1) × 10{sup –4}, a lunar-daily variation with amplitude A{sub L} = (4.8 ± 2.1) × 10{sup –4}, and a sidereal-daily variation with amplitude A{sub S} = (4.2 ± 1.7) × 10{sup –4} were found upon proceeding the data series over a 622-day interval (from July 2015 to March 2017). The {sup 213}Po half-life mean value is found to be T{sub 1/2} = 3.705 ± 0.001 μs. The reference value is corrected by 12%.

07 ISOTOPE AND RADIATION SOURCES↗

A mathematical representation of an advanced helicopter for piloted simulator investigations of control system and display variations

A mathematical model of an advanced helicopter is described. The model is suitable for use in control/display research involving piloted simulation. The general design approach for the six degree of freedom equations of motion is to use the full set of nonlinear gravitational and inertial terms of the equations and to express the aerodynamic forces and moments as the reference values and first order terms of a Taylor series expansion about a reference trajectory defined as a function of longitudinal airspeed. Provisions for several different specific and generic flight control systems are included in the model. The logic required to drive various flight control and weapon delivery symbols on a pilot's electronic display is also provided. Finally, the model includes a simplified representation of low altitude wind and turbulence effects. This model was used in a piloted simulator investigation of the effects of control system and display variations for an attack helicopter mission.

Aiken, E. W.↗

Atmospheric analysis for airdata calibration on research aircraft

In-flight airdata calibrations are used to determine the aerodynamic influence of an airplane on pitot-static pressure measurements of altitude and speed. Conventional flight-test calibration techniques are briefly reviewed and meteorological analysis methods for estimating calibration reference values of atmospheric conditions are described. There are cases where some conventional in-flight techniques are not entirely satisfactory for research aircraft because of added equipment requirements or flight envelope and location limitations. In these cases, atmospheric wind and pressure information can be used to complement conventional techniques. Accuracy of the atmospheric measurements and the variability of upper-air winds and pressure values are discussed. Results from several flight research aircraft show that wind reference calibration is generally less accurate than calibration accuracy standards for civil and research aircraft. Examples of pressure reference altimetry derived from meteorological analyses are also presented for a variety of flight research programs. These flight data show that the reference pressure accuracy provided by meteorological analyses is usually within civil aircraft and flight research airdata calibration accuracy standards. Meteorological analyses altimetry is particularly useful when it is not feasible to restrict the test airplane altitude, location, or maneuver envelope.

Ehernberger, L. J.↗