Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reducing heat load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Detailed Evaluation of Electric Demand Load Shifting Potential of Heat Pump Water Heaters

Future utilities will emphasize home appliances to reduce greenhouse gas emissions while providing electric load shifting and demand profile management. Heat pump water heaters (HPWH) have demonstrated the ability to cut water heating energy by more than 65% compared with conventional electric resistance waters (ERWH). Laboratory research was conducted on the load shifting potential of grid-connected heat pump water heaters (HPWH), compared to ERWHs. Testing applied different CTA-2045 command designs. Highly-controlled laboratory experiments were conducted on one ERWH and four HPWHs, including a prototype incorporating the new CTA-2045-B protocol feature allowing ‘advanced’ load up above the tank setpoint. The prototype unit with the B-protocol increased tank temperature by 15oF (8.3C) under the advanced load up providing an increase of 1.8 kWh of storage for a 50-gallon (189 liter) tank. The prototype includes a built-in mixing valve to meet anti-scalding codes. With the load-shaping ability of CTA-2045-B, utilities might be able to store excess renewable energy in connected tanks when renewable wind and solar resource production is high. Tests were performed under baseline conditions (no load shift) and under several load-shifting schemes, including load up and advanced load up, ahead of shed commands. Grid-connected HPWHs reduced peak demand by as much as 0.5 kW, depending on tank volume, time of day, control scheme, and draw profile.

heat pump water heater, Demand flexibility, load s↗

Advanced absorber heat integration via heat exchange packings

A rate-based model of an absorption column was developed and used to analyze several intercooling strategies utilizing “heat exchange packings.” These packings are capable of removing heat from the column and transferring it to a cooling fluid within the packing. For absorption of CO 2 into aqueous monoethanolamine under industrial conditions, intercooling via heat exchange packings placed along 10–20% of the column could reduce the column height by ~15%. The height of these columns was close to the minimum theoretical value, calculated by numerically optimizing the temperature profile. Effective intercooling could also be achieved by using the cool, rich solvent as the cooling fluid. This reduces the cooling load and facilitates recovery of waste heat. Heat exchange packings could also be used to redistribute heat within the column, reducing the column height with no net cooling load. However, this approach requires larger heat transfer coefficients than have been experimentally observed.

20 FOSSIL-FUELED POWER PLANTS↗

Flight prototype CO2 and humidity control system

A regenerable CO2 and humidity control system is presently being developed for potential use on shuttle as an alternative to the baseline lithium hydroxide system. The system utilizes a sorbent material (designated HS-C) to adsorb CO2 and the latent heat load from the cabin atmosphere and desorb the CO2 and water vapor overboard when exposed to a space vacuum, thus reducing the overall vehicle heat rejection load. Continuous operation is achieved by utilizing two beds which are alternatively cycled between adsorption and desorption. The HS-C material process was verified. Design concepts for the auxiliary components for the HS-C prototype system were generated. Performance testing verified system effectiveness in controlling CO2 partial pressure and humidity.

Rudy, K. M.↗

Baffle design for earth radiation rejection in the Cryogenic Limb-Scanning Interferometer/Radiometer

The Cryogenic Limb-Scanning Interferometer/Radiometer (CLIR) is being developed to observe infrared emissions of the earth's upper atmosphere from space. The earth's surface is an extended source of intense background radiation with a small angular separation from the desired scene. The CLIR employs an off-axis Gregorian Telescope whose primary mirror and baffles are cooled by an open-cycle cryogen system. A system of specular annular baffles has been developed to minimize both stray light problems and cryogen consumption by retro-mapping the aperture into itself. Each off-axis ray which enters the aperture and strikes the specular baffle surface is reflected so that it passes out of the aperture and is not absorbed on a cryogenic surface. The specular baffle which lies closest to the aperture is an ellipsoid whose foci trace out the circular aperture on revolution about the axis. Its theoretical 'ray trace' efficiency is 100 percent. A subsequent baffle has an elliptical cross section whose near focus traces out the central hole in the ellipsoidal baffle and whose far focus traces out the aperture. Its theoretical efficiency is about 90 percent. These baffles reduce the earth radiation heat load on the cryogenic cooler by an order of magnitude, changing it from the dominant cause of cryogen consumption to a relatively small effect. An aperture shield is also desirable to reduce cryogen consumption, stray light, and contamination.

Bremer, J. C.↗

Modeling Advanced Strippers for CO2 Capture from Gas-Fired Power Plants using Aqueous Piperazine

Energy performance of 5 m piperazine was evaluated with an advanced stripper at the pilot scale, accounting for heat loss. Modeling studies indicated that heat loss at locations other than the heat source impacted the heat duty. For strippers with excess packing, the column was the most important source of heat loss, and values as low as 0.03 GJ/hr can cause pinch and reabsorption of CO2. Solvents like 5 m PZ are more affected by heat loss in the column due to a top-side temperature pinch at high lean loading. Heat loss impacts NGCC CO2 capture more than coal-based CO2 capture. Surface temperature measurements pilot plants showed that heat loss was 50-75% controlled by natural convection. Measured heat loss was correlated with steam flowrate and wind speed and ranged from 8126 to 219668 Btu/hr, representing 35% of the measured heat rate on average. Net heat duty linearly varied with CO2 removal at low lean loading and was similar for coal and NGCC conditions at fixed removal. At 90% removal, net heat duty was about 2.5 GJ/t with 4 and 12% CO2 in the flue gas. 7 At NGCC conditions, strippers with finite packing can benefit from a flashing feed to the top of the column by using a hot bypass. A flashing feed was linked to a reduction in irreversibility of the stripper from temperature driving forces. It also reduces heat duty by up to 6% at fixed packing height and reduces packing requirement for a fixed steam heater size compared to a warm bypass. Lean loading and lean solvent rate were effective handles to maximize profitability of a fixed stripper design at low gas price. High ambient temperature operation can benefit from low pressure stripping to about 0.18 lean loading at 150 ℃ to maintain the cyclic capacity at reduced rich loading. At low gas price, the capture plant was able to maximize profitability even with a high heat duty of 2.7-3.1 GJ/t at a lean loading of 0.2-0.22 mol/mol. Heat recovery by partial water vapor condensation in a gas-liquid exchanger can be replaced by a direct contact condenser (DCC). The DCC improved gas cooling and reduced heat duty compared to the CO2 exchanger at 0.2 lean loading. The DCC when used with a 150 ℃/5.5 bar stripper can reduce the cost of capture compared to the base case by $3- 4/tonne at 15 ft of packing (optimum) but increases cost of capture by $6/tonne with a 120 ℃/2 bar stripper and 10 ft of packing (optimum). The DCC can work effectively with a solvent with a high heat of absorption and thermal stability.

Suresh Babu, Athreya↗

Calorimeter Heat Flux Trends in NASA’s Subscale Rotating Detonation Rocket Engine

A calorimeter-style rotating detonation rocket engine (RDRE) outer chamber body was designed, additively manufactured in GRCop-42, and hot-fire tested in test cell 105 at NASA Marshall Space Flight Center (MSFC) in Huntsville, AL in August 2024. Steady-state, spatially resolved heat flux and chamber pressure were measured at 13 and 9 locations from the injector face, respectively, for a variety of test conditions and hardware configurations with gaseous methane and oxygen propellants. The 2-in. diameter highly instrumented design, enabled by metal additive manufacturing (AM), allowed for simultaneous measurement of heat flux and chamber pressure through 44 long duration hot-fire tests without failure. Of the 44 tests, only 3 of the tests featured chamber pressures below 100 psia and are discussed in this work. Heat flux trends for this subscale hardware are explored with respect to local propellant mass flux for several different injectors, chamber lengths, and chamber “subsonic” area ratios (contraction ratios). Results show that for increasing chamber pressure, a reduced amount of energy per kilogram of propellant is transferred to the wall. Switching injectors affects the near-face heat flux and chamber pressure profiles. Chamber length does not noticeably affect the heat flux profile but increases bulk heat load. A subsonic area ratio greater than 1 reduces heat losses to the wall compared to a straight annulus case. Equivalence ratio shift did not significantly affect heat flux. Computational fluid dynamics (CFD) and conjugate heat transfer (CHT) analyses were performed to delineate 3-D heat transfer and coolant mass flow maldistribution effects and create a calorimeter transfer function to transform heat flux data and mitigate the profile distortions. Additional CFD/CHT simulations were performed using experimental data as boundary conditions to assess local nucleate boiling propensity during testing and to assess projected hot wall temperatures for future fatigue assessment. Vapor fractions were observed locally for several cases. It is anticipated that this effort will provide a common framework for coolant system design/analysis in calorimeter systems for rocket-based and air-breathing combustors, ensuring greater repeatability in calorimetry measurements across the research community.

Joseph Hernandez-McCloskey↗

Assessing plasma face component thermal response to rotating 3D magnetic fields for SPARC tokamak

Thermal response simulations of plasma-facing components (PFCs) in the SPARC tokamak, performed with the HEAT code, show that three-dimensional (3D) heat loads resulting from stationary n=1 perturbations require highly radiative scenarios, with up to 95% of the power crossing the separatrix (P SOL ) being radiated, to maintain PFC temperatures within acceptable operational limits, whereas the application of slowly rotating 3D fields substantially reduces the thermal loads. The HEAT module, developed to predict heat loads from non-axisymmetric plasmas, is extended to model time-dependent heat flux patterns generated by rotating 3D fields, and a comprehensive thermal analysis is performed on PFCs subjected to both the maximum and minimum power loads, as well as to rotating heat flux distributions, to evaluate the temperature evolution for varying perturbation amplitudes and rotation frequencies. The extension of this analysis to 3D fields with toroidal mode number n=2 shows that this configuration leads to weaker localized heat flux peaks relative to the n=1 case, enabling safe operation with less than 80% of the power radiated when static 3D fields of low amplitude are applied, while using slowly rotating fields at higher amplitudes. These results indicate that n=2 perturbations are generally less detrimental to divertor power exhaust, emphasizing the strong dependence of divertor power exhaust on the characteristics of the applied 3D fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improving AHU Performance by Minimizing Approach Temperature, Reducing Air Maldistribution, and Efficiently Handling Sensible and Latent Loads (Phase 1 Interim Final Technical Report)

Residential air handling units (AHUs) have stayed the same in form and efficiency for the past 30+ years, with incremental improvements made to address safety, functionality, and energy-efficiency. The purpose of this research in Phase I, Topic 9a: Next Generation Residential Air Handlers, was to improve AHU performance by minimizing heat exchanger (HX) approach temperature, reducing air maldistribution, and developing alternative system configurations which more efficiently handle sensible and latent loads. In this research Optimized Thermal Systems (OTS) developed, modeled, and evaluated multiple alternative system concepts. A dual vapor compression system separate sensible and latent cooling (SSLC) concept was studied to inform work on alternative concepts and to show best-case performance benefit. System concepts included ejector enhanced vapor compression cycles, desiccant assisted dehumidification, dual evaporator SSLC, and alternative AHU HX configurations. A dual vapor compression system showed COP improvement of 20%, however, required additional components, increased unit size, and increased cost. Two types of ejector enhanced vapor compression cycles with dual evaporators improved system COP by 9 to 11%, and reduced AHU losses by as much as 18%, with design changes limited to the AHU, no unit physical size increase, and a moderate increase to system first cost. Desiccant assisted air-conditioning required increased air flow rate resulting in higher fan power and the desiccant wheel increased sensible heat load leading to increased compressor power and reduced system COP. Dual evaporator cycles were found to degrade performance due to increased expansion losses. Optimized single slab HX designs used in place of the traditional A-coil HX led to 44–49% reduction in aluminum, 47–60% less refrigerant charge, and improved HX velocity distribution.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental investigation on phase change material–based finned tube heat exchanger for thermal energy storage and building envelope thermal management

Phase change materials (PCMs) are attractive solutions for thermal energy storage (TES) applications by absorbing and releasing large amounts of latent heat during solid–liquid phase transitions. However, their relatively low thermal conductivity requires novel heat exchanger–based solutions to improve the power density and overall energy storage efficiency of the TES system. This work presents the design and experimental results of a finned tube heat exchanger to store collected natural thermal energy from a building envelope in a latent-based TES and to release it later for building heating/cooling applications. We experimentally evaluate the finned tube heat exchanger and evaluate the performance of TES in reducing building heating and cooling loads over 3–4 h of desired time of operation (e.g., peak load). The optimized design allows for maximum energy density by minimizing the heat exchanger volume, and the system is evaluated experimentally using commercially available heat exchanger materials and an organic PCM. Here, the experimental results reveal that the TES system is able to charge and discharge stored latent energy within 3–4 h, matching peak building electricity demand duration under an average fluid flow rate of 0.136 kg/s and temperature difference of 5.55 °C. Importantly, such optimized designs illuminate a path toward TES designs that are low-cost, scalable, and optimized for thermal energy and power availability under the desired time of operation.

25 ENERGY STORAGE↗

Enhancing EnergyPlus capabilities to model dynamic building envelopes using python plugin

Nearly half of the energy consumption in the United States is related to buildings, resulting in an urgent need to develop innovative technologies to improve building energy efficiency. Dynamic building envelopes, comprising switchable insulation and thermal energy storage materials, have been proposed recently as a promising solution to reduce buildings' heating and cooling loads by thermally coupling the indoor environment with the ambient environment when beneficial while decoupling them when outdoor conditions are not favorable. Although various related technologies are still underway, the whole-building energy modeling tools, like EnergyPlus, do not have the capability to simulate the transient and dynamic nature of dynamic envelope materials and components to accurately predict their impact on building energy use. The objective of this study is to formulate a method in EnergyPlus simulation engine to model multilayer envelopes, comprising dynamic building materials with variable thermophysical properties, and discuss the changes made to the program using a Python plugin. Furthermore, the thermal performance of the dynamic envelopes using the proposed method is compared and verified with the results from a well-established commercial code, COMSOL Multiphysics. A parametric assessment is also conducted to evaluate the energy efficiency benefits of dynamic envelopes in a single-family residential building, demonstrating total annual energy savings up to 11.6 %, when a dynamic envelope operates alone, and up to 18.2 % when it is combined with a thin layer of phase change material as a thermal storage medium. Finally, a United States wide energy efficiency assessment is presented to showcase the geographical spread of the energy savings. The method designed and implemented in this study provides the researchers with the ability to implement their dynamic insulation methods in EnergyPlus and evaluate the whole building energy impact.

25 ENERGY STORAGE↗

A non-volatile thermal switch for building energy savings

Compared with traditional static insulation, a thermally switchable building envelope could reduce annual heating and cooling loads by intermittently coupling to the outside environment when beneficial. Here, we demonstrate a voltage-actuated, contact/non-contact thermal switch that meets the unique challenges of this application. The switch is non-volatile, consuming electricity only briefly while switching and none to hold steady state. The switch ratio is 12, the off state has a low effective thermal conductivity of 0.045 W m -1 K -1 , comparable to fiberglass insulation, and the performance is stable over 1,000 switching cycles. Numerical simulations using real-world climate data show that combining this thermal switch with a thermal storage layer in a building envelope can yield annual energy savings of 9%-55% (heating) and 17%-76% (air conditioning), depending on the climate zone. The greatest benefits are realized when the exterior temperature crosses well above and below the desired interior temperature within a single 24 h period.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Community Geothermal: Energy, Cost, and Carbon Modeling for District Design - Ann Arbor, MI

This data includes results on an analysis of existing and projected energy, cost, and carbon for the City of Ann Arbor - District Geothermal Design and Deployment to Equitably Decarbonize Low Income Neighborhoods in Ann Arbor project. The scope of the project includes designing and implementing a geothermal district heating and cooling system that reduces thermal heating and cooling load by 75% and greenhouse gas emissions by 40% in the project area (262 households, 6 commercial buildings). The existing neighborhood was modeled using Design Builder, an EnergyPlus software, to understand the current energy load. The energy model was then flipped to reflect the designed district geothermal heating and cooling system to project the effect on energy, carbon, and cost. This dataset includes the analysis files utilized and created for this study. There are 3 categories of data: 1) existing/benchmarking, 2) energy modeling, and 3) post processed calculations. This follows the methodology and process of the project team, which is fully explained in file 00_Technical Economic Environmental Assessment. All uses of data are referenced throughout this assessment to their respective files included below.

15 GEOTHERMAL ENERGY↗

Sodium-Cooled Fast Reactor Proliferation Resistance and Physical Protection White Paper

The Sodium-Cooled Fast Reactor (SFR) system was identified during the Generation IV Technology Roadmap as a promising technology to perform the actinide management mission and, if enhanced economics for the system could be realized, also the electricity and heat production missions. The main characteristics of the SFR that make it especially suitable for the actinide management mission are: Consumption of transuranics in a closed fuel cycle, thus reducing the radiotoxicity and heat load which facilitates waste disposal and geologic isolation; Enhanced utilization of uranium resources through efficient management of fissile materials and multi-recycle; and, High level of safety achieved through inherent and passive means that accommodate transients and bounding events with significant safety margins.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Numerical Experiments of Counterflowiing Jet Effects on Supersonic Slender-Body Configurations

Previous studies have demonstrated that the use of counterflowing jets can greatly reduce the drag and heat loads on blunt-body geometries, especially when the long penetration mode jet condition can be established. Previously, the authors had done some preliminary numerical studies to determine the ability to establish long penetration mode jets on a typical Mach 1.6 slender configuration, and study its impact on the boom signature. The results indicated that a jet with a longer penetration length was required to achieve any impact on the boom signature of a typical Mach 1.6 slender configuration. This paper focuses on an in-depth parametric study, done using the space-time conservation element solution element Navier-Stokes flow solver, for investigating the effect of various counterflowing jet conditions/configurations on two supersonic slender-body models (cone-cylinder and quartic body of revolution). The study is aimed at gaining a better understanding of the relationship between the shock penetration length and reduction of drag and boom signature for these two supersonic slender-body configurations. Different jet flow rates, Mach numbers, nozzle jet exit diameters and jet-to-base diameter ratios were examined. The results show the characteristics of a short-to-long-to-short penetration-mode pattern with the increase of jet mass flow rates, observed across various counterflowing jet nozzle configurations. Though the optimal shock penetration length for potential boom-signature mitigation is tied to the long penetration mode, it often results in a very unsteady flow and leads to large oscillations of surface pressure and drag. Furthermore, depending on the geometry of the slender body, longer jet penetration did not always result in maximum drag reduction. For the quartic geometry, the maximum drag reduction corresponds well to the longest shock penetration length, while this was not the case for the cone-cylinder-as the geometry was already optimized for drag. Numerical results and assessments obtained from this parametric study along with the recommendation for future implementation of counterflowing jets as a means for drag and noise reduction are detailed in this paper.

Venkatachari, Balaji Shankar↗

Extreme Environment Hot Fire Durability of Post-Processed Additively Manufactured GRCop-Alloy Combustion Chambers in LOX/Hydrogen and LOX/Methane

Extreme environment survivability of metal additive manufactured (AM) GRCop-alloy thrust chambers has been demonstrated in different bi-propellants at near stoichiometric and even oxygen rich combustion. GRCop-alloy chambers tested at NASA Marshall Space Flight Center (MSFC) have accumulated over 26,000 seconds of hot fire duration and over 500 starts. These chambers are produced using an AM process called laser powder bed fusion (L-PBF). A major feature of this process is high wall surface roughness which can be customized in post processing to leverage various performance advantages. Post-processing can include heat treatment, final machining, polishing, and welding and is key to hardware survivability in extreme environments. Surface finish enhancement techniques were applied to the hot wall and coolant channels to reduce the overall total heat load to the chamber walls. Performance optimization of various thrust class TCA’s is a strategic technology goal of NASA MSFC. Three different chamber geometries using cryogenic methane and de-ionized water as coolants were hot fire tested to obtain their life cycle, pressure drop, and heat load performances. Several 1.2K lbf LOX/H2 chambers, 1K lbf LOX/CH4 chambers, and 7K lbf LOX/CH4 chambers were tested. All post-processed configurations performed remarkably well when subjected to extreme hot fire test conditions. Streaking and blanching due to localized oxygen rich conditions were observed on some test articles in their as-built surface finish state. However, this is actually a function of the injector mixing and only serves to further establish the durability of L-PBF GRCop-alloy thrust chambers. Several different polishing techniques were applied to the hot wall and integrated coolant channels prior to hot fire testing and their performances assessed. Overall, AM produced GRCop chambers are extremely reliable, durable, and customizable to the desired performance metrics.

grcop↗

Thermal Cycle and Capacitance Testing of Mezzo Industries Phase Changer Material Heat Capacitor

Effective Thermal management is essential for the safety and performance of human spacecraft, especially during long-duration missions with fluctuating heat loads. Phase Change Material (PCM) heat exchangers offer a compact, efficient solution by storing and releasing thermal energy through latent heat during phase transitions. This allows PCM systems to buffer transient thermal loads without immediate heat rejection, reducing the need for oversized radiators – particularly critical during ascent and re-entry when radiators are stowed. By maintaining stable temperatures in crew cabins and equipment bays, PCM technology enhances crew comfort, protects sensitive systems, and supports long-term mission sustainability with minimal mass and volume impact. A phase change material heat capacitor prototype, designed and built under a NASA Small Business Innovation Research grant by Mezzo Technologies, utilizes a laser welding microtube manufacturing process that promises increased reliability and performance over current manufacturing methods like brazing. This heat exchanger was tested through coolant thermal cycling within the expected flow rates and temperature range of the Orion spacecraft, the crewed spacecraft taking NASA astronauts to the moon under the Artemis Program. The useful heat storage capacitance was measured and compared to Orion spacecraft requirements.

Active Thermal Control Systems↗

Influence of Photovoltaic Shading on Rooftop Heat Transfer, Building Energy Loads, and Photovoltaic Power Output

Photovoltaic (PV) modules on building rooftops provide shade from summer heating, leading to a reduction in cooling load during hot seasons. However, PV shading also reduces passive solar heating during winter months, leading to an increase in the building heating load during cold seasons. In this study, the heat transfer performance of an enclosure formed by adjacent PV modules is analyzed for three locations in the United States, comparing the daily heat flux through rooftops for the case of a PV-shaded rooftop as well as an unshaded roof. Several result metrics are developed as part of this work, including the saved energy load (SEL), or the energy conserved by adding PV-shading to the rooftop, and the additional energy load (AEL), or the supplemental building energy required to replace shaded solar heating. Lastly, this work calculates the utility factor, being the ratio of SEL and PV power output to AEL as a metric of PV effectiveness. SELs are 5.2, 6.2, and 11.7 kWh/m 2 · year for Dayton, Boise, and Phoenix, respectively, while the AELs for the same locations are 1.6, 1.5, and 2.1 kWh/m 2 · year. The utility factors for the same three locations are 61, 71, and 79. In general, locations with hot, non-cloudy summers and clear skies in winter see the largest utility factor. Further, it is shown that PV shading can conserve building energy during the winter months by preventing radiative losses to cold winter skies.

13 HYDRO ENERGY↗

Long term cryogen storage in space - A feasibility study

The conduction of future space missions will require the long term storage of cryogens in space. Such missions will be performed in connection with the employment of the long life version of the Shuttle Infrared Telescope Facility (SIRTF), the Large Deployable Reflector (LDR), Gravity Probe B (GPB), Orbital Transfer Vehicles (OTVs), and the Space Station. The feasibility of building a long lifetime helium Dewar for space applications has been studied. A feasible concept was to be developed for a Shuttle-launchable 3-yr lifetime Dewar. The developed concept was to be used for the identification of key technology development areas. The desired long lifetime requires the minimization of the parasitic heat loads. It has been found that the majority of the parasitic heat load can be provided by the fiberglass-epoxy tension band supports. A new type of support system, the Passive Orbital Disconnect Strut (PODS), was developed to reduce the considered contribution to the heat load.

Kittel, P.↗