Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reduced Metal Use”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Near-Net Shape Powder Metallurgy Rhenium Thruster

This paper describes the development of a method to produce a near-net shape (NNS) powder metallurgy (PM) rhenium combustion chamber of the size 445 N (100 lbf) used in a high performance liquid apogee engine. These engines are used in low earth Orbit and geostationary orbit for satellite positioning systems. The developments in near-net shape powder metallurgy rhenium combustion chambers reported in this paper will reduce manufacturing cost of the rhenium chambers by 25 percent, and reduce the manufacturing time by 30 to 40 percent. The quantity of rhenium metal powder used to produce a rhenium chamber is reduced by approximately 70 percent and the subsequent reduction in machining schedule and costs is nearly 50 percent.

Leonhardt, Todd↗

Superior Metal‐Organic Framework Activation with Dimethyl Ether

Abstract Metal–organic frameworks (MOFs) are demonstrated to be readily activated by treatment with the low surface tension, low boiling point solvent dimethyl ether (DME). The mildness of the method enables access to high surface areas by avoiding structural changes in the framework that often plague thermal activation methods. A distinction from previous methods is that DME activation succeeds for materials with coordinatively unsaturated sites (CUS) and non‐CUS MOFs as well. DME displaces solvent molecules occupying the pores of the MOF as well as those coordinated to metal centers; reducing evacuation temperature by using a coordinating, yet highly volatile guest enables low temperature activation with structural retention as demonstrated surface area measurements that match or exceed existing activation protocols.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct/Alternating Current Electrochemical Method for Removing and Recovering Heavy Metal from Water Using Graphene Oxide Electrode

Treatment of heavy-metal pollution in both point-of-use water and industrial wastewater is critical in protecting human health and the environment. Current methods for heavy-metal treatment in both sources have limitations. For point-of-use water, current methods usually suffer from limited capacity and difficulties in spontaneously removing multiple heavy metals. For industrial wastewater, current methods greatly reduce the value of heavy metal by precipitating them as sludge which requires further treatment. Here we developed an electrochemical method that can treat both low-concentration and high-concentration heavy-metal pollution using either direct current (DC) or alternating current (AC) electrodeposition with graphene-oxide-modified carbon felt electrode (CF-GO). The graphene oxide provides a high density of surface functional groups to assist the electrodeposition. The electrodeposition method showed 2 orders of magnitude higher capacity (>29 g heavy metal for 1 g of graphene oxide) compared with traditional adsorption methods. For low levels of heavy-metal pollution in point-of-use water, DC electrodeposition with a CF-GO electrode can reduce single heavy-metal ion pollution (Cu, Cd, and Pb) as well as multiple ion mixtures to below safe water drinking levels. This method can tolerate a much wider range of heavy-metal pollution in point-of-use water than traditional adsorption methods. For high-level pollution in industrial wastewater, AC electrodeposition can recover >99.9% heavy-metal ions. Finally, by tuning the AC frequency and voltage, the electrodeposition method can further selectively recover Cu, Cd, and Pb separately, which adds values to the heavy-metal removal process.

36 MATERIALS SCIENCE↗

Designing the Platinum Catalyst Layer for Improved Performance and Durability in Anion Exchange Membrane Water Electrolysis

To lower the cost of hydrogen produced by anion exchange membrane water electrolysis (AEMWE), it is critical to reduce the use of platinum group metal (PGM) catalysts within the device. While iridium has been successfully replaced with PGM-free catalysts at the anode, platinum-based (Pt) cathode catalysts are still required to meet the activity and durability targets. This study investigates the impact of commercial Pt/C catalyst loading, ionomer type and content, and electrode fabrication method on the cathode catalyst layer properties and AEMWE performance with the aim of determining the feasibility of reduced Pt loadings. While increased Pt loading is found to improve beginning-of-life performance, the effects are minimal above 0.6 mg/cm 2 . Ink characterization shows that ionomer type and content affect the ink stability, particle size, and percent of unbound ionomer, which further impact the homogeneity of the sprayed catalyst layers. The 5% PiperION cathode exhibited the highest performance, which may be attributed to a balance between the small particle size and the low proportion of unbound ionomer, minimizing kinetic and transport losses. Theoretical calculations show that the ionomers interact differently with the Pt surface, causing different surface charges and water adsorption strength and activating different mechanisms for hydrogen evolution. Pt-PiperION lowered the enthalpy of water-splitting by 0.1 eV compared to Pt alone and allowed for equal site access between adsorbed H* and OH* (both adsorbed at circa −2.2 eV). Although catalyst-coated membrane (CCM) fabrication techniques are desirable for scale-up, no performance enhancement is observed compared with the catalyst-coated substrate approach. Durability, as measured by degradation rates, Pt loss, and catalyst layer restructuring, was found to improve with increased Pt loadings, higher ionomer content, and CCM architectures. These findings provide important insight into the significant role of the cathode in AEMWE and strategies for maintaining the performance with low Pt loading or PGM-free catalysts.

08 HYDROGEN↗

Pyrochlore-type catalysts for the reforming of hydrocarbon fuels

A method of catalytically reforming a reactant gas mixture using a pyrochlore catalyst material comprised of one or more pyrochlores having the composition A.sub.2-w-xA'.sub.wA''.sub.xB.sub.2-y-zB'.sub.yB''.sub.zO.sub.7-.DELTA.. Distribution of catalytically active metals throughout the structure at the B site creates an active and well dispersed metal locked into place in the crystal structure. This greatly reduces the metal sintering that typically occurs on supported catalysts used in reforming reactions, and reduces deactivation by sulfur and carbon. Further, oxygen mobility may also be enhanced by elemental exchange of promoters at sites in the pyrochlore. The pyrochlore catalyst material may be utilized in catalytic reforming reactions for the conversion of hydrocarbon fuels into synthesis gas (H.sub.2+CO) for fuel cells, among other uses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pyrochlore catalysts for hydrocarbon fuel reforming

A method of catalytically reforming a reactant gas mixture using a pyrochlore catalyst material comprised of one or more pyrochlores having the composition A 2 B 2-y-z B' y B" z O 7-.DELTA. , where y>0 and z.gtoreq.0. Distribution of catalytically active metals throughout the structure at the B site creates an active and well dispersed metal locked into place in the crystal structure. This greatly reduces the metal sintering that typically occurs on supported catalysts used in reforming reactions, and reduces deactivation by sulfur and carbon. Further, oxygen mobility may also be enhanced by elemental exchange of promoters at sites in the pyrochlore. The pyrochlore catalyst material may be utilized in catalytic reforming reactions for the conversion of hydrocarbon fuels into synthesis gas (H 2 +CO) for fuel cells, among other uses.

Berry, David A.↗

Investigating In Situ Bioremediation Approahces for Sustained Uranium Immobilization Independent of Nitrate Reduction

The primary goal of this project was to gain a better understanding of the microbiological diversity and community composition in low-pH, high-nitrate environments. The research made use of enrichment cultures grown from DOE Oak Ridge Field Research Center (FRC) sediments in T.J. Phelps’ lab at Oak Ridge National Laboratory (ORNL), with the intention of identifying those bacterial species capable of reducing, and therefore immobilizing, metals and radionuclides without the use of nitrate/nitrite and without requiring the removal of nitrate/nitrite. Previous studies have shown that microbial diversity is high in sediments contaminated with radionuclides and metals (Anderson et al., 2003; Chang et al., 2001; Nevin et al., 2003; Holmes et al., 2002; Petrie et al., 2003) and that low G+C Gram-positive species of bacteria were present in enrichments from low-pH, high-nitrate contaminated sediments (Petrie et al., 2003). This was particularly important for the current project, as it was hypothesized that under strictly anaerobic conditions certain Gram-positive genera, such as Clostridium, may carry out uranium reduction in low pH environments without the need or ability to use nitrate/nitrite as an electron acceptor. Chemically, a low-pH environment has the potential to inhibit metal reducers from utilizing reduced U(IV) as an electron donor for nitrate reduction (Finneran et al., 2002), leading to a stable U(IV) species in low-pH, high-nitrate sediments. Uranium stability under these conditions provides key knowledge required to develop new protocols that will aid in the successful bioremediation of DOE waste sites.

54 ENVIRONMENTAL SCIENCES↗

Dual energy CT: How well can pseudo-monochromatic imaging reduce metal artifacts?

Purpose: Dual Energy CT (DECT) provides so-called monoenergetic images based on a linear combination of the original polychromatic images. At certain patient-specific energy levels, corresponding to certain patient- and slice-dependent linear combination weights, e.g., E = 160 keV corresponds to α = 1.57, a significant reduction of metal artifacts may be observed. The authors aimed at analyzing the method for its artifact reduction capabilities to identify its limitations. The results are compared with raw data-based processing. Methods: Clinical DECT uses a simplified version of monochromatic imaging by linearly combining the low and the high kV images and by assigning an energy to that linear combination. Those pseudo-monochromatic images can be used by radiologists to obtain images with reduced metal artifacts. The authors analyzed the underlying physics and carried out a series expansion of the polychromatic attenuation equations. The resulting nonlinear terms are responsible for the artifacts, but they are not linearly related between the low and the high kV scan: A linear combination of both images cannot eliminate the nonlinearities, it can only reduce their impact. Scattered radiation yields additional noncanceling nonlinearities. This method is compared to raw data-based artifact correction methods. To quantify the artifact reduction potential of pseudo-monochromatic images, they simulated the FORBILD abdomen phantom with metal implants, and they assessed patient data sets of a clinical dual source CT system (100, 140 kV Sn) containing artifacts induced by a highly concentrated contrast agent bolus and by metal. In each case, they manually selected an optimal α and compared it to a raw data-based material decomposition in case of simulation, to raw data-based material decomposition of inconsistent rays in case of the patient data set containing contrast agent, and to the frequency split normalized metal artifact reduction in case of the metal implant. For each case, the contrast-to-noise ratio (CNR) was assessed. Results: In the simulation, the pseudo-monochromatic images yielded acceptable artifact reduction results. However, the CNR in the artifact-reduced images was more than 60% lower than in the original polychromatic images. In contrast, the raw data-based material decomposition did not significantly reduce the CNR in the virtual monochromatic images. Regarding the patient data with beam hardening artifacts and with metal artifacts from small implants the pseudo-monochromatic method was able to reduce the artifacts, again with the downside of a significant CNR reduction. More intense metal artifacts, e.g., as those caused by an artificial hip joint, could not be suppressed. Conclusions: Pseudo-monochromatic imaging is able to reduce beam hardening, scatter, and metal artifacts in some cases but it cannot remove them. In all cases, the CNR is significantly reduced, thereby rendering the method questionable, unless special post processing algorithms are implemented to restore the high CNR from the original images (e.g., by using a frequency split technique). Raw data-based dual energy decomposition methods should be preferred, in particular, because the CNR penalty is almost negligible.

60 APPLIED LIFE SCIENCES↗

Key Issues for Aerospace Applications of Ceramic Matrix Composites

Ceramic matrix composites (CMC) offer significant advantages for future aerospace applications including turbine engine and liquid rocket engine components, thermal protection systems, and "hot structures". Key characteristics which establish ceramic matrix composites as attractive and often enabling choices are strength retention at high temperatures and reduced weight relative to currently used metallics. However, due to the immaturity of this class of materials which is further compounded by the lack of experience with CMC's in the aerospace industry, there are significant challenges involved in the development and implementation of ceramic matrix composites into aerospace systems. Some of the more critical challenges are attachment and load transfer methodologies; manufacturing techniques, particularly scale up to large and thick section components; operational environment resistance; damage tolerance; durability; repair techniques; reproducibility; database availability; and the lack of validated design and analysis tools. The presentation will examine the technical issues confronting the application of ceramic matrix composites to aerospace systems and identify the key material systems having potential for substantial payoff relative to the primary requirements of light weight and reduced cost for future systems. Current programs and future research opportunities will be described in the presentation which will focus on materials and processes issues.

Clinton, R. G., Jr.↗

Clinical Evaluation of Normalized Metal Artifact Reduction in kVCT Using MVCT Prior Images (MVCT-NMAR) for Radiation Therapy Treatment Planning

Purpose: To evaluate the metal artifacts in diagnostic kilovoltage computed tomography (kVCT) images of patients that are corrected by use of a normalized metal artifact reduction (NMAR) method with megavoltage CT (MVCT) prior images: MVCT-NMAR. Methods and Materials: MVCT-NMAR was applied to images from 5 patients: 3 with dual hip prostheses, 1 with a single hip prosthesis, and 1 with dental fillings. The corrected images were evaluated for visualization of tissue structures and their interfaces and for radiation therapy dose calculations. They were compared against the corresponding images corrected by the commercial orthopedic metal artifact reduction algorithm in a Phillips CT scanner. Results: The use of MVCT images for correcting kVCT images in the MVCT-NMAR technique greatly reduces metal artifacts, avoids secondary artifacts, and makes patient images more useful for correct dose calculation in radiation therapy. These improvements are significant, provided the MVCT and kVCT images are correctly registered. The remaining and the secondary artifacts (soft tissue blurring, eroded bones, false bones or air pockets, CT number cupping within the metal) present in orthopedic metal artifact reduction corrected images are removed in the MVCT-NMAR corrected images. A large dose reduction was possible outside the planning target volume (eg, 59.2 Gy to 52.5 Gy in pubic bone) when these MVCT-NMAR corrected images were used in TomoTherapy treatment plans without directional blocks for a prostate cancer patient. Conclusions: The use of MVCT-NMAR corrected images in radiation therapy treatment planning could improve the treatment plan quality for patients with metallic implants.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Passive neutron coincidence counting with plastic scintillators for the characterization of radioactive waste drums

The quantification of radioactive material is essential in the fields of safeguards, criticality control of nuclear processes, dismantling of nuclear facilities and components, or radioactive waste characterization. The Nuclear Measurement Laboratory (LMN) of CEA is involved in the development of time-correlated neutron detection techniques using plastic scintillators. Usually, 3He proportional counters are used for passive neutron coincidence counting owing to their high thermal neutron capture efficiency and gamma insensitivity. However, the global {sup 3}He shortage in the past few years has made these detectors extremely expensive. In addition, contrary to {sup 3}He counters for which a few tens of microseconds are needed to thermalize fast neutrons, in view to maximize the {sup 3}He(n,p){sup 3}H capture cross section, plastic scintillators are based on elastic scattering and therefore the light signal is formed within a few nanoseconds, correlated pulses being detected within a few dozen- or hundred nanoseconds. This time span reflects fission particles time of flight, which allows reducing accordingly the duration of the coincidence gate and thus the rate of random coincidences, which may totally blind fission coincidences when using {sup 3}He counters in case of a high (α,n) reaction rate. However, plastic scintillators are very sensitive to gamma rays, requiring the use of a thick metallic shield to reduce the corresponding background. Cross talk between detectors is also a major issue, which consists on the detection of one particle by several detectors due to elastic or inelastic scattering, leading to true but undesired coincidences. Data analysis algorithms are tested to minimize cross-talk in simultaneously activated detectors. The distinction between useful fission coincidences and the correlated background due to cross-talk, (α,n) and induced (n,2n) or (n,n'γ) reactions, is achieved by measuring 3-fold coincidences. The performances of a passive neutron coincidence counting system for radioactive waste drums using plastic scintillators have been studied using the Monte Carlo radiation transport code MCNPX-PoliMi v2.0 coupled to data processing algorithms developed with ROOT data analysis software. In addition to the correlated background, accidental coincidences are taken into account in the simulation by randomly merging pulses from different calculations with fission and (α,n) sources. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method for producing La/Ce/MM/Y base alloys, resulting alloys and battery electrodes

A carbothermic reduction method is provided for reducing a La-, Ce-, MM-, and/or Y-containing oxide in the presence of carbon and a source of a reactant element comprising Si, Ge, Sn, Pb, As, Sb, Bi, and/or P to form an intermediate alloy material including a majority of La, Ce, MM, and/or Y and a minor amount of the reactant element. The intermediate material is useful as a master alloy for in making negative electrode materials for a metal hydride battery, as hydrogen storage alloys, as master alloy additive for addition to a melt of commercial Mg and Al alloys, steels, cast irons, and superalloys; or in reducing Sm.sub.2O.sub.3 to Sm metal for use in Sm--Co permanent magnets.

25 ENERGY STORAGE↗

WE-G-18A-07: Clinical Evaluation of Normalized Metal Artifact Reduction in KVCT Using MVCT Prior Images (MVCT-NMAR) Technique in Radiotherapy

Purpose: To evaluate the metal artifacts in diagnostic kVCT images of patients that are corrected using a normalized metal artifact reduction method with MVCT prior images, MVCT-NMAR. Methods: An MVCTNMAR algorithm was developed and applied to five patients: three with bilateral hip prostheses, one with unilateral hip prosthesis and one with dental fillings. The corrected images were evaluated for visualization of tissue structures and their interfaces, and for radiotherapy dose calculations. They were also compared against the corresponding images corrected by a commercial metal artifact reduction technique, O-MAR, on a Phillips™ CT scanner. Results: The use of MVCT images for correcting kVCT images in the MVCT-NMAR technique greatly reduces metal artifacts, avoids secondary artifacts, and makes patient images more useful for correct dose calculation in radiotherapy. These improvements are significant over the commercial correction method, provided the MVCT and kVCT images are correctly registered. The remaining and the secondary artifacts (soft tissue blurring, eroded bones, false bones or air pockets, CT number cupping within the metal) present in O-MAR corrected images are removed in the MVCT-NMAR corrected images. Large dose reduction is possible outside the planning target volume (e.g., 59.2 Gy in comparison to 52.5 Gy in pubic bone) when these MVCT-NMAR corrected images are used in TomoTherapy™ treatment plans, as the corrected images no longer require directional blocks for prostate plans in order to avoid the image artifact regions. Conclusion: The use of MVCT-NMAR corrected images in radiotherapy treatment planning could improve the treatment plan quality for cancer patients with metallic implants. Moti Raj Paudel is supported by the Vanier Canada Graduate Scholarship, the Endowed Graduate Scholarship in Oncology and the Dissertation Fellowship at the University of Alberta. The authors acknowledge the CIHR operating grant number MOP 53254.

60 APPLIED LIFE SCIENCES↗

Fission Product Separation from Pyrochemical Electrolyte by Cold Finger Melt Crystallization

This work contributes to the development of pyroprocessing technology as an economically viable means of separating used nuclear fuel from fission products and cladding materials. Electrolytic oxide reduction is used as a head-end step before electrorefining to reduce oxide fuel to metallic form. The electrolytic medium used in this technique is molten LiCl-Li2O. Groups I and II fission products, such as cesium (Cs) and strontium (Sr), have been shown to partition from the fuel into the molten LiCl-Li2O. Various approaches of separating these fission products from the salt have been investigated by different research groups. One promising approach is based on a layer crystallization method studied at the Korea Atomic Energy Research Institute (KAERI). Despite successful demonstration of this basic approach, there are questions that remain, especially concerning the development of economical and scalable operating parameters based on a comprehensive understanding of heat and mass transfer. This research explores these parameters through a series of experiments in which LiCl is purified, by concentrating CsCl in a liquid phase as purified LiCl is crystallized and removed via an argon-cooled cold finger.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Superior Metal‐Organic Framework Activation with Dimethyl Ether

Abstract Metal–organic frameworks (MOFs) are demonstrated to be readily activated by treatment with the low surface tension, low boiling point solvent dimethyl ether (DME). The mildness of the method enables access to high surface areas by avoiding structural changes in the framework that often plague thermal activation methods. A distinction from previous methods is that DME activation succeeds for materials with coordinatively unsaturated sites (CUS) and non‐CUS MOFs as well. DME displaces solvent molecules occupying the pores of the MOF as well as those coordinated to metal centers; reducing evacuation temperature by using a coordinating, yet highly volatile guest enables low temperature activation with structural retention as demonstrated surface area measurements that match or exceed existing activation protocols.

Wright, Keenan R.↗

Bio-reduction of ferrihydrite-montmorillonite-organic matter complexes: Effect of montmorillonite and fate of organic matter

Organic matter (OM) is often associated with Fe (hydr)oxides such as ferrihydrite (Fh) in soils and sediments, forming binary Fh-OM complexes. Microbial reduction of Fh results in destabilization of the complexes and mineral/OM transformation. However, little is known about the role of clay minerals in such processes, despite their common co-existence with Fh and OM in natural environments. Here Fh-OM complexes were synthesized in the presence of montmorillonite (SWy-2), forming ternary Fh-(SWy-2)-OM complexes. A metal-reducing bacterium Geobacter sulfurreducens was used to reduce Fh in the complexes under circumneutral pH and anoxic conditions with or without H 2 as extra electron donor. Various spectroscopy and mass spectrometry methods were used to monitor the progress of Fh bio-reduction and mineral/OM transformation. Results showed that G. sulfurreducens utilized mineral-bound OM as electron donor and/or carbon source to couple with Fh reduction. Relative to Fh-OM complex, Addition of SWy-2 to Fh-OM complex enhanced the bio-reduction extent of Fh by increasing the proportion of bioavailable OM that was weakly bound to SWy-2. However, its effect on the bio-reduction rate was variable. SWy-2 initially decreased the rate, because it spatially separated OM (electron donor) from Fh (electron acceptor). During later incubation, SWy-2 increased the reduction rate by sorbing biogenic Fe 2+ that would otherwise passivate the Fh and cell surfaces. Bio-reduction transformed mineral-bound OM to microbial products (e.g. necromass, extracellular polymeric substances), but organic compounds with aromatic structures, carboxyl groups and large molecular weight were more resistant to desorption and oxidation. The persistence of these compounds against bio-reduction induced transformation is likely due to their stronger binding with minerals and/or lower nominal oxidation states of carbon relative to other compounds. Our results provide new insights into the role of clay minerals in regulating biogeochemical cycling of solid-phase Fe and transformation of mineral-associated OM in anoxic soil environments.

58 GEOSCIENCES↗

Benzoin Radicals as Reducing Agent for Synthesizing Ultrathin Copper Nanowires

Here, we report a new, general synthetic approach that uses heat driven benzoin radicals to grow ultrathin copper nanowires with tunable diameters. This is the first time carbon organic radicals have been used as a reducing agent in metal nanowire synthesis. In-situ temperature dependent electron paramagnetic resonance (EPR) spectroscopic studies show that the active reducing agent is the free radicals produced by benzoins under elevated temperature. Furthermore, the reducing power of benzoin can be readily tuned by symmetrically decorating functional groups on the two benzene rings. When the aromatic rings are modified with electron donating (withdrawing) groups, the reducing power is promoted (suppressed). The controllable reactivity gives the carbon organic radical great potential as a versatile reducing agent that can be generalized in other metallic nanowire syntheses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bioproduction of cerium-bearing magnetite and application to improve carbon-black supported platinum catalysts

Biogeochemical processing of metals including the fabrication of novel nanomaterials from metal contaminated waste streams by microbial cells is an area of intense interest in the environmental sciences. Here we focus on the fate of Ce during the microbial reduction of a suite of Ce-bearing ferrihydrites with between 0.2 and 4.2 mol% Ce. Cerium K-edge X-ray absorption near edge structure (XANES) analyses showed that trivalent and tetravalent cerium co-existed, with a higher proportion of tetravalent cerium observed with increasing Ce-bearing of the ferrihydrite. The subsurface metal-reducing bacterium Geobacter sulfurreducens was used to bioreduce Ce-bearing ferrihydrite, and with 0.2 mol% and 0.5 mol% Ce, an Fe(II)-bearing mineral, magnetite (Fe(II)(III) 2 O 4 ), formed alongside a small amount of goethite (FeOOH). At higher Ce-doping (1.4 mol% and 4.2 mol%) Fe(III) bioreduction was inhibited and goethite dominated the final products. During microbial Fe(III) reduction Ce was not released to solution, suggesting Ce remained associated with the Fe minerals during redox cycling, even at high Ce loadings. In addition, Fe L 2,3 X-ray magnetic circular dichroism (XMCD) analyses suggested that Ce partially incorporated into the Fe(III) crystallographic sites in the magnetite. The use of Ce-bearing biomagnetite prepared in this study was tested for hydrogen fuel cell catalyst applications. Platinum/carbon black electrodes were fabricated, containing 10% biomagnetite with 0.2 mol% Ce in the catalyst. The addition of bioreduced Ce-magnetite improved the electrode durability when compared to a normal Pt/CB catalyst. Different concentrations of Ce can inhibit the bioreduction of Fe(III) minerals, resulting in the formation of different bioreduction products. Bioprocessing of Fe-minerals to form Ce-containing magnetite (potentially from waste sources) offers a sustainable route to the production of fuel cell catalysts with improved performance.

59 BASIC BIOLOGICAL SCIENCES↗