Radiation protection measurements around a 12 MeV mobile dedicated IORT accelerator

Purpose: The aim of this study is to investigate radioprotection issues that must be addressed when dedicated accelerators for intraoperative radiotherapy (IORT) are used in operating rooms. Recently, a new version of a mobile IORT accelerator (LIAC Sordina SpA, Italy) with 12 MeV electron beam has been implemented. This energy is necessary in some specific pathology treatments to allow a better coverage of thick lesions. At an electron energy of 10 MeV, leakage and scattered x-ray radiation (stray radiation) coming from the accelerator device and patient must be considered. If the energy is greater than 10 MeV, the x-ray component will increase; however, the most meaningful change should be the addition of neutron background. Therefore, radiation exposure of personnel during the IORT procedure needs to be carefully evaluated. Methods: In this study, stray x-ray radiation was measured and characterized in a series of spherical projections by means of an ion chamber survey meter. To simulate the patient during all measurements, a polymethylmethacrylate (PMMA) slab phantom with volume 30x30x15 cm{sup 3} and density 1.19 g/cm{sup 3} was used. The PMMA phantom was placed along the central axis of the beam in order to absorb the electron beams and the tenth value layer (TVL) and half value layer (HVL) of scattered radiation (at 0 deg., 90 deg., and 180 deg. scattering angles) were also measured at 1 m of distance from the phantom center. Neutron measurements were performed using passive bubble dosimeters and a neutron probe, specially designed to evaluate ambient dose equivalent H{sup *}(10). Results: The x-ray equivalent dose measured at 1 m along the beam axis at 12 MeV was 260 {mu}Sv/Gy. The value measured at 1 m at 90 deg. scattering angle was 25 {mu}Sv/Gy. The HVL and TVL values were 1.1 and 3.5 cm of lead at 0 deg., and 0.4 and 1 cm at 90 deg., respectively. The highest equivalent dose of fast neutrons was found to be at the surface of the phantom on the central beam axis (2.9{+-}0.6 {mu}Sv/Gy), while a lower value was observed below the phantom (1.6{+-}0.3 {mu}Sv/Gy). The neutron dose equivalent at 90 deg. scattering angle and on the floor plane on the beam axis below the beam stopper was negligible. Conclusions: Our data confirm that neutron exposure levels around the new dedicated IORT accelerator are very low. Mobile shielding panels can be used to reduce x-ray levels to below regulatory levels without necessarily providing permanent shielding in the operating room.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation protection for high energy implantation of light ions in a production environment

In recent years the irradiation of semiconductor devices by light ions with high energies has increasingly become a well-established method to adjust charge carrier lifetimes in semiconductor devices. To introduce this process into the end of frontend production environment several measures in terms of radiation safety will have to be obeyed. An overview on thresholds for particles induced gamma emission will be given, starting with the {sup 11}B(p,{gamma}){sup 12}C reaction at 163keV. The environment has to be shielded from gamma rays, therefore those implanters have to be situated in adequate enclosures. Calculations for specific implant energies are done to define the thicknesses of tool enclosures. A set of radiation detectors monitors the values at well-defined positions online and radiation values are fed into a superordinate system that is directly coupled to the main power supply of the implanter.

36 MATERIALS SCIENCE↗

Nanocomposites for electromagnetic radiation protection

Specific features that characterize nanoparticles and which are due to their small size and allow one to enhance the interaction between the electromagnetic radiation and nanostructured materials and to develop the effective protection of man and equipment against harmful uncontrolled radiation are reported. Examples of the development of nanocomposite radar absorbing materials that can be used for protection of man and equipment are presented.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation Protective Coveralls for Fermilab’s SPOT Robot

Fermilab’s Accelerator Division recently purchased a SPOT robot from Boston Dynamics to be used to automatically measure the residual radiation in the beamline tunnels. Fermilab will work with the College of DuPage Fashion Studies Department to design and develop a prototype Tyvek-garments (coveralls and booties) that can be easily used and replicated by the Fermilab operators to shield the SPOT robot from collecting radioactive dust while deployed.

43 PARTICLE ACCELERATORS↗

Determining Beta Radiation Protection Factors for Eye Shields

The purpose of this experiment was to determine the efficacy of INL eye shields in attenuating beta radiation and was performed in response to changes in international and national standards and guidelines. Two methods were used to determine the protection factor for each eye shield: A Fixed Evaluation and a Dosimetry Evaluation. Both evaluations showed the PAPR hood as the least protective eye shield and the respirator face mask as having the highest protection factor. Seven of the eye shields challenge the INL protection factor criteria of 3 and will require further testing. Though the two methods varied widely, the results were consistent.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Certified Health Physicist’s Reflections on a 40-Year Career in Radiation Protection

This is a reflection from a certified health physicist regarding his becoming aware, during his 40-year career, that the linear no-threshold (LNT) model and the associated As Low As Reasonably Achievable concept have no scientific basis and make no positive contribution to radiation safety. They should be replaced by an alternative, scientifically based model that includes a threshold, below which there is no harm, and recognition of hormesis and the adaptive response, which reflect the benefits of low-dose and low-dose-rate radiation exposure. Continued use of the unscientific LNT model is not conservative, as most regulators complacently claim but actually harmful. Examples of these harmful impacts in the areas of nuclear power, nuclear medicine, and environmental management are included.

61 RADIATION PROTECTION AND DOSIMETRY↗

High repetition rate laser systems: targets, diagnostics and radiation protection

Accessing the high repetition regime of ultra intense laser-target interactions at small or moderate laser energies is now possible at a large number of facilities worldwide. New projects such as HiPER and ELI promise to extend this regime to the high energy realm at the multi-kJ level. This opportunity raises several issues on how best to approach this new regime of operation in a safe and efficient way. At the same time, a new class of experiments or a new generation of secondary sources of particles and radiation may become accessible, provided that target fabrication and diagnostics are capable of handling this rep-rated regime. In this paper, we explore this scenario and analyse existing and perspective techniques that promise to address some of the above issues.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Individual Radiation Protection Monitoring in the Marshall Islands. Utrōk Atoll (2010-2012)

As a hard copy supplement to the Marshall Islands Program website (https://marshallislands.llnl.gov), this document provides an overview of the individual radiological surveillance monitoring program established in support of residents of Utrōk Atoll and nonresident citizens of the Utrōk Atoll population group, along with full disclosure of verified measurement data (2010-2012). The Utrōk Atoll Whole Body Counting Facility has been temporarily stationed on Majuro Atoll and, in cooperation with the Utrōk Atoll Local Government, serves as a national radiological facility open to the general public.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetry and cancer risk estimations for different radiation protection solutions at decommissioning a contaminated nuclear power plant site

Contaminated sediments originating from dredging activities in a nuclear power plant site were placed in a pond, which has to be taken into consideration during the future decommissioning process. The sediments have to be handled to free release the site. The radionuclides Co-60 and Cs-137 were identified and the activity concentrations (Bq/kg) were quantified in the range of 10–6000 and 5–50 Bq kg -1 , respectively. The absorbed dose rate to individuals of various ages and sex present at the site of the dry pond area was estimated. The radiological impact in terms of lifetime attributable risk (LAR) and effective dose were calculated. For a 30-year-old male exposed during one year without any action regarding the sediments in the dried out pond, the LAR was predicted to be 0.0027, which recalculated to effective dose corresponds to 7.6 mSv year -1 . The calculations show that countermeasures will be needed for the contaminated site.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation Protection Aspects of the Linac Coherent Light Source Front End Enclosure

The Front End Enclosure (FEE) of the Linac Coherent Light Source (LCLS) is a shielding housing located between the electron dump area and the first experimental hutch. The upstream part of the FEE hosts the commissioning diagnostics for the FEL beam. In the downstream part of the FEE, two sets of grazing incidence mirror and several collimators are used to direct the beam to one of the experimental stations and reduce the bremsstrahlung background and the hard component of the spontaneous radiation spectrum. This paper addresses the beam loss assumptions and radiation sources entering the FEE used for the design of the FEE shielding using the Monte-Carlo code FLUKA. The beam containment system prevents abnormal levels of radiations inside the FEE and ensures that the beam remains in its intended path is also described.

Vollaire, J.↗