Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Updated Mortality Analysis of Radiation Workers at Rocketdyne (Atomics International), 1948-2008

Updated analyses of mortality data are presented on 46,970 workers employed 1948-1999 at Rocketdyne (Atomics International). Overall, 5,801 workers were involved in radiation activities, including 2,232 who were monitored for intakes of radionuclides, and 41,169 workers were engaged in rocket testing or other non-radiation activities. The worker population is unique in that lifetime occupational doses from all places of employment were sought, updated and incorporated into the analyses. Further, radiation doses from intakes of 14 different radionuclides were calculated for 16 organs or tissues using biokinetic models of the International Commission on Radiation Protection (ICRP). Because only negligible exposures were received by the 247 workers monitored for radiation activities after 1999, the mean dose from external radiation remained essentially the same at 13.5 mSv (maximum 1 Sv) as reported previously, as did the mean lung dose from external and internal radiation combined at 19.0 mSv (maximum 3.6 Sv). An additional 9 years of follow-up, from December 31,1999 through 2008, increased the person-years of observation for the radiation workers by 21.7% to 196,674 (mean 33.9 years) and the number of cancer deaths by 50% to 684. Analyses included external comparisons with the general population and the computation of standardized mortality ratios (SMRs) and internal comparisons using proportional hazards models and the computation of relative risks (RRs). A low SMR for all causes of death (SMR 0.82; 95% CI 0.78-0.85) continued to indicate that the Rocketdyne radiation workers were healthier than the general population and were less likely to die. The SMRs for all cancers taken together (SMR 0.88; 95% CI 0.81-0.95), lung cancer (SMR 0.87; 95% CI 0.76-1.00) and leukemia other than chronic lymphocytic leukemia (CLL) (SMR 1.04; 95% 0.67-1.53) were not significantly elevated. Cox regression analyses revealed no significant dose-response trends for any cancer. For all cancers excluding leukemia, the RR at 100 mSv was estimated as 0.98 (95% CI 0.82-1.17), and for all leukemia other than CLL it was 1.06 (95% CI 0.50-2.23). Uranium was the primary radionuclide contributing to internal exposures, but no significant increases in lung and kidney disease were seen. The extended follow-up reinforces the findings in the previous study in failing to observe a detectable increase in cancer deaths associated with radiation, but strong conclusions still cannot be drawn because of small numbers and relatively low career doses. Larger combined studies of early workers in the United States using similar methodologies are warranted to refine and clarify radiation risks after protracted exposures.

33 ADVANCED PROPULSION SYSTEMS↗

Use of Existing CAD Models for Radiation Shielding Analysis

The utility of a radiation exposure analysis depends not only on the accuracy of the underlying particle transport code, but also on the accuracy of the geometric representations of both the vehicle used as radiation shielding mass and the phantom representation of the human form. The current NASA/Space Radiation Analysis Group (SRAG) process to determine crew radiation exposure in a vehicle design incorporates both output from an analytic High Z and Energy Particle Transport (HZETRN) code and the properties (i.e., material thicknesses) of a previously processed drawing. This geometry pre-process can be time-consuming, and the results are less accurate than those determined using a Monte Carlo-based particle transport code. The current work aims to improve this process. Although several Monte Carlo programs (FLUKA, Geant4) are readily available, most use an internal geometry engine. The lack of an interface with the standard CAD formats used by the vehicle designers limits the ability of the user to communicate complex geometries. Translation of native CAD drawings into a format readable by these transport programs is time consuming and prone to error. The Direct Accelerated Geometry -United (DAGU) project is intended to provide an interface between the native vehicle or phantom CAD geometry and multiple particle transport codes to minimize problem setup, computing time and analysis error.

Lee, K. T.↗

Simulation–Extrapolation for Bias Correction with Exposure Uncertainty in Radiation Risk Analysis Utilizing Grouped Data

Summary In observational epidemiological studies, the exposure that is received by an individual often cannot be precisely observed, resulting in measurement error, and a common approach to dealing with measurement error is regression calibration (RC). Use of RC, which requires assumptions about the distribution of unknown error-free (true) variables, leads to concern about the possibility of bias due to misspecification of that distribution. The simulation–extrapolation (SIMEX) method, in contrast, does not require a distributional assumption. However, analyses of large cohorts may be performed by using grouped or person-year data, and application of SIMEX to grouped data is not straightforward, particularly when there is a mixture of classical and Berkson measurement errors. We compared RC and SIMEX with grouped data analyses to assess robustness of the RC method to misspecification of the true dose distribution. We also applied SIMEX assuming mixtures of classical and Berkson errors and compared the results with those obtained by using RC for classical error only. SIMEX had less bias than RC and performed well regardless of the true dose distribution, whereas RC based on a misspecified true dose distribution showed greater bias than when based on the correctly specified true dose distribution.

Misumi, Munechika↗

Analysis of Radiation Damage in Electronics of Unmanned Aerial and Ground Robotic Platforms - 19470

Gamma ray measurements are important for monitoring of nuclear facilities. Robotic platforms are used to carry radiation detectors and cameras to enable remote sensing and visual surveillance, allowing for the operation in hazardous, hard to reach zones. The prediction of radiation damage in electronic components of robots is vital. The radiation damage analysis was carried out for two robotic platforms exposed to neutron and gamma ray flux: a ground hexapod platform PhantomX (a 'spider robot') and an aerial platform - the DJI S1000+ octocopter. The FLUKA code was used to analyze the displacement per atom values in electronic components of these robots. The packaging of the components and the shielding design was determined to increase the robot's lifetime in areas where radiation dose levels are high. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Monte Carlo simulation analysis for radiation damage on Glidcop Al-15 caused by 17-20 MeV/u heavy ions

The Facility for Rare Isotope Beams (FRIB) SRF linear heavy-ion accelerator is designed to accelerate all ions up to uranium to a maximum beam power of 400 kW. Several beam intercepting devices (BIDs) are essential to the successful operation of the accelerator, including a low power charge selector (LPCS) made of copper containing 0.15% precipitated aluminum oxide by weight called Glidcop Al-15. As FRIB ramps up the primary beam power beyond the current 20 kW level, the charge selector must withstand higher radiation damage rates, typically measured in displacements per atom (dpa). Significant beam induced radiation damage including significant deformation, like swelling, blistering, and cracking has been observed on a recently removed LPCS. We also observed physical features up to about 5.5 mm wide and appear to be deeper than the projected range of any ions. This paper presents the results of Monte Carlo simulations carried out using the Particle and Heavy Ion Transport code System (PHITS), quantifying the total damage dose and ion concentration, etc. Simulating an accurate irradiation history is essential to determining the scope of post irradiation examination (PIE) work.

Fletcher, Ethan [Michigan State U.]↗

3-ID HXN Beamline Radiation Shielding Analysis

This note documents the radiation shielding analysis of Hard X-ray Nanoprobe (HXN, 3 ID) beamline at 500 mA, including Gas Bremsstrahlung (GB) and Synchrotron Radiation (SR).

36 MATERIALS SCIENCE↗

10-ID IXS Beamline Radiation Shielding Analysis

This note documents the radiation shielding analysis of Inelastic X-ray Scattering (IXS, 10 ID) beamline at 500 mA, including Gas Bremsstrahlung (GB) and Synchrotron Radiation (SR).

36 MATERIALS SCIENCE↗

28-ID XPD Beamline Radiation Shielding Analysis

This note documents the radiation shielding analysis of X-ray Powder Diffraction (XPD, 28 ID) beamline at 500 mA, including Gas Bremsstrahlung (GB) and Synchrotron Radiation (SR).

36 MATERIALS SCIENCE↗

5-ID SRX Beamline Radiation Shielding Analysis

This note documents the radiation shielding analysis of Submicron Resolution X-ray Spectroscopy (SRX, 5 ID) beamline at 500 mA, including Gas Bremsstrahlung (GB) and Synchrotron Radiation (SR).

36 MATERIALS SCIENCE↗

SMI 12ID SGB Radiation Shielding Analysis

This note documents the radiation shielding analysis of Soft Matter Interfaces (SMI 12ID) beamline at 500 mA, for Scattered Gas Bremsstrahlung (GB) in First Optical Enclosure (FOE).

36 MATERIALS SCIENCE↗

Gastrointestinal Dose-Histogram Effects in the Context of Dose-Volume–Constrained Prostate Radiation Therapy: Analysis of Data From the RADAR Prostate Radiation Therapy Trial

Purpose: To use a high-quality multicenter trial dataset to determine dose-volume effects for gastrointestinal (GI) toxicity following radiation therapy for prostate carcinoma. Influential dose-volume histogram regions were to be determined as functions of dose, anatomical location, toxicity, and clinical endpoint. Methods and Materials: Planning datasets for 754 participants in the TROG 03.04 RADAR trial were available, with Late Effects of Normal Tissues (LENT) Subjective, Objective, Management, and Analytic (SOMA) toxicity assessment to a median of 72 months. A rank sum method was used to define dose-volume cut-points as near-continuous functions of dose to 3 GI anatomical regions, together with a comprehensive assessment of significance. Univariate and multivariate ordinal regression was used to assess the importance of cut-points at each dose. Results: Dose ranges providing significant cut-points tended to be consistent with those showing significant univariate regression odds-ratios (representing the probability of a unitary increase in toxicity grade per percent relative volume). Ranges of significant cut-points for rectal bleeding validated previously published results. Separation of the lower GI anatomy into complete anorectum, rectum, and anal canal showed the impact of mid-low doses to the anal canal on urgency and tenesmus, completeness of evacuation and stool frequency, and mid-high doses to the anorectum on bleeding and stool frequency. Derived multivariate models emphasized the importance of the high-dose region of the anorectum and rectum for rectal bleeding and mid- to low-dose regions for diarrhea and urgency and tenesmus, and low-to-mid doses to the anal canal for stool frequency, diarrhea, evacuation, and bleeding. Conclusions: Results confirm anatomical dependence of specific GI toxicities. They provide an atlas summarizing dose-histogram effects and derived constraints as functions of anatomical region, dose, toxicity, and endpoint for informing future radiation therapy planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Space radiation shielding analysis and dosimetry for the Space Shuttle program

Active and passive radiation dosimeters have been flown on every Space Shuttle mission to measure the naturally-occurring, background Van Allen and galactic cosmic radiation doses that astronauts and radiation-sensitive experiments and payloads receive. A review of the various models utilized at the NASA/Johnson Space Center, Radiation Analysis and Dosimetry is presented. An analytical shielding model of the Shuttle was developed as an engineering tool to aid in making premission radiation dose calculations and is discussed in detail. The anatomical man models are also discussed. A comparison between the onboard dosimeter measurements for the 24 Shuttle missions to date and the dose calculations using the radiation environment and shielding models is presented.

Atwell, William↗

Radiative Flux Analysis (RADFLUXANAL) Value-Added Product: Retrieval of Clear-Sky Broadband Radiative Fluxes and Other Derived Values

The Radiative Flux Analysis (RADFLUX) is a technique for using surface broadband radiation measurements for detecting periods of clear (i.e., cloudless) skies, and using the detected clear-sky data to fit functions that are then used to produce continuous clear-sky estimates. The clear-sky estimates and measurements are then used in various ways to infer cloud macrophysical properties. This value-added product (VAP) is based on methodologies developed by Dr. Charles N. Long as referenced in the papers below. It is an updated version of an earlier value-added data product called the Shortwave (SW) Clear-Sky Detection and Fitting Algorithm (SWCLRID). Two major improvements were made over the SWCLRID data product: 1) input data were first run through the Data Quality Assessment for Atmospheric Radiation Measurement (ARM) Radiation Data (QCRAD) VAP to better screen for data quality, and 2) additional processing was implemented to also include longwave (LW) clear sky estimates and derived values.

54 ENVIRONMENTAL SCIENCES↗