Importance of Window Installation in Residential Building Envelopes Having Continuous External Insulation in Order to Realize Energy Efficiency

Residential buildings are one of the prime candidates in the United States for reducing energy consumption. Continuous exterior insulation (CEI) is being used increasingly often in residential buildings to improve energy efficiency. Windows constitute 15–40% of a building envelope and are the weakest component in energy performance. The installation of windows in walls with CEI has not been well evaluated. We identified four cases of installing windows in walls with CEI of 25–76 mm (1–3 in.) thickness and analyzed the energy loss between the window and wall interface (flanking loss), structural issues, air leakage, and moisture penetration. Thermal analysis showed that the insulation value (RSI) of the 305 mm (12 in.) perimeter wall surrounding a window decreased by 7.6–34.5% in the four cases when compared with the RSI of the wall without the window. A window installation method is proposed to address the issues likely to occur with installation methods currently being used in the field. An out-of-the-box installation system was also designed to achieve a better thermal performance, cost effectiveness, and structural performance in high-performance residential buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Structural active cooling applications for the Space Shuttle.

Analytic and experimental studies have been conducted to evaluate a number of active cooling approaches to structural thermal protection for the Space Shuttle. The primary emphasis was directed toward the thermal protection system. Trade study results are presented for various heat shield material and TPS arrangements. Both metallic and reusable surface insulation (RSI) concepts were considered. Active systems heat sinks consisted of hydrogen, phase change materials, and expendable water. If consideration is given only to controlling the surface temperature, passive TPS was found to provide the most efficient system. Use of active cooling which incorporates some interior temperature control made the thermally less efficient RSI system more attractive.

Masek, R. V.↗

Optimization of thermal protection systems for the space shuttle vehicle. Volume 1: Final report

A study performed to continue development of computational techniques for the Space Shuttle Thermal Protection System is reported. The resulting computer code was used to perform some additional optimization studies on several TPS configurations. The program was developed in Fortran 4 for the CDC 6400, and it was converted to Fortran 5 to be used for the Univac 1108. The computational methodology is developed in modular fashion to facilitate changes and updating of the techniques and to allow overlaying the computer code to fit into approximately 131,000 octal words of core storage. The program logic involves subroutines which handle input and output of information between computer and user, thermodynamic stress, dynamic, and weight/estimate analyses of a variety of panel configurations. These include metallic, ablative, RSI (with and without an underlying phase change material), and a thermodynamic analysis only of carbon-carbon systems applied to the leading edge and flat cover panels. Two different thermodynamic analyses are used. The first is a two-dimensional, explicit precedure with variable time steps which is used to describe the behavior of metallic and carbon-carbon leading edges. The second is a one-dimensional implicity technique used to predict temperature in the charring ablator and the noncharring RSI. The latter analysis is performed simply by suppressing the chemical reactions and pyrolysis of the TPS material.

Source record↗

Development and Design Application of Rigidized Surface Insulation Thermal Protection Systems, Volume 1

Materials and design technology of the all-silica LI-900 rigid surface insulation (RSI) thermal protection system (TPS) concept for the shuttle spacecraft is presented. All results of contract development efforts are documented. Engineering design and analysis of RSI strain arrestor plate material selections, sizing, and weight studies are reported. A shuttle prototype test panel was designed, analyzed, fabricated, and delivered. Thermophysical and mechanical properties of LI-900 were experimentally established and reported. Environmental tests, including simulations of shuttle loads represented by thermal response, turbulent duct, convective cycling, and chemical tolerance tests are described and results reported. Descriptions of material test samples and panels fabricated for testing are included. Descriptions of analytical sizing and design procedures are presented in a manner formulated to allow competent engineering organizations to perform rational design studies. Results of parametric studies involving material and system variables are reported. Material performance and design data are also delineated.

Source record↗

Vibration and stress analysis of soft-bonded shuttle insulation tiles. Modal analysis with compact widely space stringers

An efficient iterative procedure is described for the vibration and modal stress analysis of reusable surface insulation (RSI) of multi-tiled space shuttle panels. The method, which is quite general, is rapidly convergent and highly useful for this application. A user-oriented computer program based upon this procedure and titled RESIST (REusable Surface Insulation Stresses) has been prepared for the analysis of compact, widely spaced, stringer-stiffened panels. RESIST, which uses finite element methods, obtains three dimensional tile stresses in the isolator, arrestor (if any) and RSI materials. Two dimensional stresses are obtained in the tile coating and the stringer-stiffened primary structure plate. A special feature of the program is that all the usual detailed finite element grid data is generated internally from a minimum of input data. The program can accommodate tile idealizations with up to 850 nodes (2550 degrees-of-freedom) and primary structure idealizations with a maximum of 10,000 degrees-of-freedom. The primary structure vibration capability is achieved through the development of a new rapid eigenvalue program named ALARM (Automatic LArge Reduction of Matrices to tridiagonal form).

Ojalvo, I. U.↗

An experimental investigation of heat transfer to reusable surface insulation tile array gaps in a turbulent boundary layer with pressure gradient

An experimental investigation was performed to determine the effect of pressure gradient on the heat transfer to space shuttle reusable surface insulation (RSI) tile array gaps under thick, turbulent boundary layer conditions. Heat transfer and pressure measurements were obtained on a curved array of full-scale simulated RSI tiles in a tunnel wall boundary layer at a nominal freestream Mach number of 10.3 and freestream unit Reynolds numbers of 1.6, 3.3, and and 6.1 million per meter. Transverse pressure gradients were induced over the model surface by rotating the curved array with respect to the flow. Definition of the tunnel wall boundary layer flow was obtained by measurement of boundary layer pitot pressure profiles, and flat plate wall pressure and heat transfer. Flat plate wall heat transfer data were correlated and a method was derived for prediction of smooth, curved array heat transfer in the highly three-dimensional tunnel wall boundary layer flow and simulation of full-scale space shuttle vehicle pressure gradient levels was assessed.

Throckmorton, D. A.↗

The effects of environmental exposure on reusable surface insulation for space shuttle

Coated specimens of reusable surface insulation (RSI) were exposed to alternate radiant heating and atmospheric exposure cycles to study the effects of surface contamination on the RSI coating. Different methods of heating were employed on clean and artificially contaminated specimens to determine the contributions of heating conditions to coating devitrification.

Ransone, P. O.↗

Evaluation of low cost/high temperature insulation, July 1974 - June 1975

Six fiber products and six insulation blankets comprising silica, alumina, zirconia, mullite, and mixed ceramic systems were subjected to furnace exposures up to 500 hours at temperatures of 1000 to 1600 C and evaluated for chemical and dimensional stability and for changes in thermal conductivity. Alumina, zirconia, and mullite fibers were fabricated into reusable surface insulation (RSI) tile by water-felting and reimpregnation with ethyl silicate. Specimens were exposed to 25 thermal cycles at 1200 C and 1400 C and a pressure of 10 and 32 torr, respectively. Production costs for 930 sq m (10,000 sq ft) of blanket insulation and of alumina RSI tile were developed.

Strauss, E. L.↗

Fundamental studies on the nature and properties of ceramic fiber insulation

Silica and mullite fibers used to fabricate reusable surface insulation (RSI) for the space shuttle orbiter may devitrify/recrystallize within the temperature range anticipated upon reentry. This is shown to be dependent upon impurity level, temperature, and time at temperature. It is determined that the effects of the material improvement and optimization program are positive. The degree of crystallinity is shown to have a predominant effect upon the strength of fabricated RSI tile, and limits are determined. Models are developed to predict tensile strengths and shrinkage rates of silica tile based upon readily measurable parameters. Thermal cycling which simulates reentry results in an increase in the crystallinity and in the porosity of tile coatings.

Mueller, J. I.↗

Prediction of in-depth gap heating ratios from wing glove model test data

In-depth gap heating ratios were predicted down RSI tile sidewalls based on temperature measurements obtained from the JSC arc-jet Wing Glove model tests in order to develop gap heating ratios which resulted in the best possible fit of test data and to produce a set of engineering verification heating ratios similar in shape to one another which could be used at various body points on the Orbiter during reentry. The Rockwell TPS Multidimensional heat conduction program was used to perform 3-D thermal analyses using a 3.0 in. thick section of a curved RSI tile with 283 nodal points. Correlation with test data shows that the predicted heating ratios were significantly higher down in the gap than the zero pressure values for T/C stacks 39 and 38 on the Wing Glove model. For stack 37 (in a low pressure region), the baseline heating ratio overpredicted the temperature data. This analysis, which showed that the heating ratios were a strong function of the product of pressure and pressure gradient, will be used to compare with recent Gap/Step and Ames Double Wedge test/analysis results in the effort to identify the Orbiter gap response to high delta P flight environment.

Source record↗

Room temperature mechanical properties of shuttle thermal protection system materials

Tests were conducted at room temperature to determine the mechanical properties and behavior of materials used for the thermal protection system of the space shuttle. The materials investigated include the LI-900 RSI tiles, the RTV-560 adhesive and the .41 cm (.16 thick) strain isolator pad (SIP). Tensile and compression cyclic loading tests were conducted on the SIP material and stress-strain curves obtained for various proof loads and load cyclic conditioning. Ultimate tensile and shear tests were conducted on the RSI, RTV, and SIP materials. The SIP material exhibits highly nonlinear stress-strain behavior, increased tangent modulus and ultimate tensile strength with increased loading rate, and large short time load relaxation and moderate creep behavior. Proof and cyclic load conditioning of the SIP results in permanent deformation of the material, hysteresis effects, and much higher tensile tangent modulus values at large strains.

Sawyer, J. W.↗

Microstructural characterization of the HRSI thermal protection system for space shuttle

Components of the space shuttle high temperature reusable surface insulation (HRSI) system were microscopically characterized, both separately and as a system, to obtain information needed for stress analysis models of the thermal protection system. A tension specimen of the HRSI system was loaded in steps and was microscopically observed at each load condition to demonstrate the tension failure mode associated with strain isolation pad (SIP) behavior. A local failure occurred which should be associated with transfer of load through transverse fibers in the SIP. Stress concentrations attributed to the SIP behavior necessitated strengthening of the HRSI by densification of the RSI at the bondline. An HRSI tile was microscopically characterized after the densification process. The densified surface layer blended into the RSI which caused a gradual change in density. The gradation in density does not appear to represent a sharp discontinuity in elastic modulus between the densified layer and the parent material.

Ransone, P. O.↗

Fatigue properties of shuttle thermal protection system

Static and cyclic load tests were conducted to determine the static and fatigue strength of the RIS tile/SIP thermal protection system used on the orbiter of the space shuttle. The material systems investigated include the densified and undensified LI-900 tile system on the .40 cm thick SIP and the densified and undensified LI-2200 tile system on the .23 cm (.090 inch) thick SIP. The tests were conducted at room temperature with a fully reversed uniform cyclic loading at 1 Hertz. Cyclic loading causes a relatively large reduction in the stress level that each of the SIP/tile systems can withstand for a small number of cycles. For example, the average static strength of the .40 cm thick SIP/LI-900 tile system is reduced from 86 kPa to 62 kPa for a thousand cycles. Although the .23 cm thick SIP/LI-2200 tile system has a higher static strength, similar reductions in the fatigue strength are noted. Densifying the faying surface of the RSI tile changes the failure mode from the SIP/tile interface to the parent RSI or the SIP and thus greatly increases the static strength of the system. Fatigue failure for the densified tile system, however, occurs due to complete separation or excessive elongation of the SIP and the fatigue strength is only slightly greater than that for the undensified tile system.

Sawyer, J. W.↗

Multiwall/RSI concept for local application to space shuttle body flap

A titanium multiwall/reusable surface insulation (MW/RSI) TPS concept designed to prevent local erosion of the RSI tiles on the upper surface of the Space Shuttle Orbiter body flap was investigated. The concept, which consisted of a combination of a titanium multiwall tile and an RSI tile, was evaluated by thermal analysis and structural and thermal testing of one configuration to assess the attachment scheme and thermal behavior. Results indicate that the MW/RSI concept will remain attached to the vehicle and provide the required thermal protection.

Shideler, John L.↗

Entry Systems Panel

As general findings, lessons learned from shuttle are: (1) bridge established between development center (JSC) Research Centers (ARC, LARC), and industry (RI, LMSC, Corning, Mansville, 3M LTV, Union Carbide, Hexcel) for shuttle TPS; (2) not all test results adequately analyzed or in hindsight, completely encompassing all failure modes; (3) gap heating effects from ground facilities not totally indicative of flight experience; (4) need to design with operations in mind (not just to cost) example: moisture intrusion of GR/EP, many other examples; (5) RSI- developed as point design for maneuvering entry vehicle of high L/D; and (6) RSI - 15 years from invention to use on flight hardware.

Rasky, Daniel J.↗

Thermal protection systems for space transportation vehicles

The topics addressed are history of reusable external insulation (RSI), and examples of shuttle RSI development challenges, which includes: (1) manufacturing of raw materials, such as fibers, coating components; (2) design of tile planform size, strain isolation, and gap heating; (3) insulation, such as bonding, bond verification, tolerances, and quality control; and (4) operation, such as durability, and water proofing.

Goldstein, Howard E.↗

Ceramic Fairings for A Hypersonic Flight Experiment

Fairings composed of Rigid Fibrous Insulations (RSI) were fabricated, instrumented, and coated using techniques that were recently developed at NASA Ames Research Center. These RSI components are part of a specific assembly of materials which were built onto a wing of a Pegasus flight vehicle. The assembly was designed to collect aerothermal data during a designated mission to deliver a satellite to earth orbit. The objective of the flight experiment is to validate the theory of boundary layer transition at flight speeds in excess of Mach 3. The actual flight experiment is scheduled to occur during the summer of 1998. Fabrication and installation methodologies will be discussed with a brief description of the wing glove assembly.

Churchward, Rex↗

The ASPRS Remote Sensing Industry Forecast: Phase II & III - Digital Sensor Compilation

In August 1999, ASPRS and NASA's (then) Commercial Remote Sensing Program (CRSP) entered into a 5-year Space Act Agreement (SAA), combining resources and expertise to: (a) Baseline the Remote Sensing Industry (RSI) based on GEIA Model; (b) Develop a 10-Year RSI market forecast and attendant processes; and (c) Provide improved information for decision makers.

Mondello, Charles↗