Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RECOILS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Exploring new physics with O(keV) electron recoils in direct detection experiments

Motivated by the recent XENON 1T results, we explore various new physics models that can be discovered through searches for electron recoils in O(keV)-threshold direct-detection experiments. First, we consider the absorption of axion-like particles, dark photons, and scalars, either as dark matter relics or being produced directly in the Sun. In the latter case, we find that keV mass bosons produced in the Sun provide an adequate fit to the data but are excluded by stellar cooling constraints. We address this tension by introducing a novel Chameleon-like axion model, which can explain the excess while evading the stellar bounds. We find that absorption of bosonic dark matter provides a viable explanation for the excess only if the dark matter is a dark photon or an axion. In the latter case, photophobic axion couplings are necessary to avoid X-ray constraints. Second, we analyze models of dark matter-electron scattering to determine which models might explain the excess. Standard scattering of dark matter with electrons is generically in conflict with data from lower-threshold experiments. Momentum-dependent interactions with a heavy mediator can fit the data with dark matter mass heavier than a GeV but are generically in tension with collider constraints. Next, we consider dark matter consisting of two (or more) states that have a small mass splitting. The exothermic (down)scattering of the heavier state to the lighter state can fit the data for keV mass splittings. Finally, we consider a subcomponent of dark matter that is accelerated by scattering off cosmic rays, finding that dark matter interacting though an O(100 keV)-mass mediator can fit the data. The cross sections required in this scenario are, however, typically challenged by complementary probes of the light mediator. Throughout our study, we implement an unbinned Monte Carlo analysis and use an improved energy reconstruction of the XENON 1T events.

79 ASTRONOMY AND ASTROPHYSICS↗

Precision three-dimensional imaging of nuclei using recoil-free jets

In this study, we explore the azimuthal angle decorrelation of lepton-jet pairs in e-p and e-A collisions as a means for precision measurements of the three-dimensional structure of bound and free nucleons. Utilizing soft-collinear effective theory, we perform the first-ever resummation of this process in e-p collisions at NNLL accuracy using a recoil-free jet axis. Our results are validated against Pythia simulations. In e-A collisions, we address the complex interplay between three characteristic length scales: the medium length L, the mean free path of the energetic parton in the medium λ, and the hadronization length L h . We demonstrate that in the thin-dilute limit, where L $\ll$ L h and L ~ λ, this process can serve as a robust probe of the three-dimensional structure for bound nucleons. We conclude by offering predictions for future experiments at the Electron-Ion Collider within this limit.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effects of recoil spectra and electronic energy dissipation on defect survival in 3C-SiC

The coincidence of electronic and damage energy dissipation from energetic ions to an atomic lattice can significantly affect damage production along the ion trajectory due to spatial overlap of inelastic and elastic processes. Damage production and disordering in single crystal 3C-SiC from 5 MeV Si and 10 MeV Au ions is investigated using ion-channeling experiments. While defects are created by damage energy dissipation via elastic scattering, electronic energy dissipation via electron-phonon coupling decreases defect survival along the ion trajectory for Si ions. Finally, the more energetic recoil spectrum for 10 MeV Au ions leads to weaker spatial coupling of electronic and damage energy dissipation processes, and damage production is only weakly affected.

36 MATERIALS SCIENCE↗

DGFRS-2—A gas-filled recoil separator for the Dubna Super Heavy Element Factory

The main goal of development of the new Dubna Gas-Filled Recoil Separator (DGFRS-2) is to sufficiently improve the efficiency of studies on heavy and superheavy nuclei at the Super Heavy Element Factory of the Flerov Laboratory of Nuclear Reactions (FLNR) at the Joint Institute for Nuclear Research. The use of beams with the intensity up to 6×10 13 s -1 (10 pμA) delivered by the DC280 cyclotron requires an effective setup providing high suppression of background reaction products. Additionally, the described gas-filled separator is optimized for synthesis and study of heavy isotopes produced in complete fusion reactions of massive nuclei. Basic characteristics of DGFRS-2, as well as the results of the first test experiments, are presented. In comparison to the DGFRS-1, the transmission efficiency was doubled, and the background was reduced by a factor 200.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Girth and groomed radius of jets recoiling against isolated photons in lead-lead and proton-proton collisions at $\sqrt{s_{NN}} = 5.02$ TeV

This Letter presents the first measurements of the groomed jet radius R g and the jet girth g in events with an isolated photon recoiling against a jet in lead-lead (PbPb) and proton-proton (pp) collisions at the LHC at a nucleon-nucleon center-of-mass energy of 5.02 TeV. The observables R g and g provide a quantitative measure of how narrow or broad a jet is. The analysis uses PbPb and pp data samples with integrated luminosities of 1.7 nb -1 and 301 pb -1 , respectively, collected with the CMS experiment in 2018 and 2017. Events are required to have a photon with transverse momentum $p^{γ}_{T} > 100$ GeV and at least one jet back-to-back in azimuth with respect to the photon and with transverse momentum $p^{jet}_{T}$ such that $p^{jet}_{T}/p^{γ}_{T} > 0.4$ . The measured R g and g distributions are unfolded to the particle level, which facilitates the comparison between the PbPb and pp results and with theoretical predictions. It is found that jets with $p^{jet}_{T}/p^{γ}_{T} > 0.8$ , i.e., those that closely balance the photon $p^{γ}_{T}$ , are narrower in PbPb than in pp collisions. Relaxing the selection to include jets with $p^{jet}_{T}/p^{γ}_{T} > 0.4$ reduces the narrowing of the angular structure of jets in PbPb relative to the pp reference. This shows that selection bias effects associated with jet energy loss play an important role in the interpretation of jet substructure measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Continuous recoil-driven lasing and cavity frequency pinning with laser-cooled atoms

Abstract Laser-cooled gases of atoms interacting with the field of an optical cavity are a versatile tool for quantum sensing and the simulation of quantum systems. These systems can exhibit phenomena such as self-organization phase transitions, lasing mechanisms, squeezed states and protection of quantum coherence. However, investigations of these phenomena typically occur in a discontinuous manner due to the need to reload atomic ensembles. Here we demonstrate hours-long continuous lasing from laser-cooled 88 Sr atoms loaded into a ring cavity. The required inversion to produce lasing arises from inversion in the atomic-momentum degrees of freedom, which is linked to the self-organization phase transitions and collective atomic recoil lasing observed previously only in a cyclic fashion. We find that over a broad parameter range, the sensitivity of the lasing frequency to changes in cavity frequency is significantly reduced due to an atomic loss mechanism, suggesting a potential approach for mitigating low-frequency cavity noise. Our findings open opportunities for continuous cavity quantum electrodynamics experiments and robust and continuous super-radiant lasers.

Schäfer, Vera M. (ORCID:0000000210003737)↗

SECAR: A recoil separator for nuclear astrophysics

Proton-and alpha-capture reactions on unstable proton-rich nuclei power astrophysical explosions like novae and X-ray bursts. Direct measurements of these reactions are crucial for understanding the mechanisms behind these explosions and the nucleosynthesis at such sites. The recoil mass separator, SECAR (SEparator for CApture Reactions) at the National Superconducting Cyclotron Laboratory (NSCL) and the Facility for Rare Isotope Beams (FRIB), has been designed with the required sensitivity to study (p,γ) and (α,γ) reactions, directly at astrophysical energies in inverse kinematics, with radioactive beams of masses up to about A = 65. The complete SECAR system, including two Wien Filters for high mass resolution, has been installed at Michigan State University and is currently being commissioned. The present article introduces the SECAR concept, its scientific goals, and provides an update of the current status of the project.

Tsintari, P↗

A neutron recoil-spectrometer for measuring yield and determining liner areal densities at the Z facility

For this study, a proof-of-principle CR-39 based neutron-recoil-spectrometer was built and fielded on the Z facility. Data from this experiment match indium activation yields within a factor of 2 using simplified instrument response function (IRF) models. The data also demonstrates the need for neutron shielding in order to infer liner areal densities. A new shielded design has been developed. The spectrometer is expected to achieve signal-to-background greater than 2 for the down-scattered neutron signal and greater than 30 for the primary signal.

47 OTHER INSTRUMENTATION↗

Simple new methods for deducing lifetimes in recoil distance Doppler-shift measurements

In this work, new approaches for lifetime determination using data from recoil distance Doppler-shift experiments are presented based on the fundamental properties of the functions describing the time evolution of the population of excited nuclear states. To some extent, one of them represents a contraction of the well-known Differential decay-curve method (DDCM) by using the most reliable data point [the maximum of the $n_i(t)$ function describing the population of level $\textit{i}$ in time] and a purely numerical procedure avoiding any fitting of decay curves. The combination with the standard DDCM analysis is promising for improving the reliability and the precision of the results for the lifetimes obtained. The novel part of the approach consists of using a chain of equations at the consecutive maxima of the ni(t) functions, which allow us to precisely determine the ratio of the lifetimes of two consecutive levels and, in the case where one of these lifetimes is known, to determine the unknown one. In addition, a simple integral derivation of the lifetime is presented involving the peak areas measured at different distances, and an application of the first moments (expectation values and centroids in time) of the $n_i(t)$ functions for determining lifetimes is also demonstrated to be useful.

47 OTHER INSTRUMENTATION↗

High-yield magnetic recoil neutron spectrometer on the National Ignition Facility for operation up to 60 MJ

We report that recent progress at the National Ignition Facility (NIF), with neutron yields of order 1 x 10 17 , places new constraints on diagnostics used to characterize implosion performance. The Magnetic Recoil neutron Spectrometer (MRS), which is routinely used to measure yield, ion temperature (T ion ), and down-scatter ratio (dsr), has been adapted to allow measurements of dsr up to 5 x 10 17 , and yield and T ion up to 2 x 10 18 in the near term with new data processing techniques and conversion foil solutions. This paper presents a solution for extending MRS operation up to a yield of 2 x 10 19 (60 MJ) by moving the spectrometer outside of the NIF shield wall. This will not only enhance the upper yield limit by 10x but also improve signal-to-background by 5x.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Creation of color centers in diamond by recoil implantation through dielectric films

The need of near-surface color centers in diamond for quantum technologies motivates the controlled doping of specific extrinsic impurities into the crystal lattice. Further, recent experiments have shown that this can be achieved by momentum transfer from a surface precursor via ion implantation, an approach known as “recoil implantation.” Here, we extend this technique to incorporate dielectric precursors for creating nitrogen-vacancy (NV) and silicon-vacancy (SiV) centers in diamond. Specifically, we demonstrate that gallium focused-ion-beam exposure to a thin layer of silicon nitride or silicon dioxide on the diamond surface results in the introduction of both extrinsic impurities and carbon vacancies. These defects subsequently give rise to near-surface NV and SiV centers with desirable properties after annealing.

42 ENGINEERING↗

The next-generation magnetic recoil spectrometer (MRSnext) on OMEGA and NIF for diagnosing ion temperature, yield, areal density, and alpha heating

The next-generation magnetic recoil spectrometer (MRSnext) is being designed to replace the current MRS at the National Ignition Facility and OMEGA for measurements of the neutron spectrum from an inertial confinement fusion implosion. The MRSnext will provide a far-superior performance and faster data turnaround than the current MRS systems, i.e., a 2× and 6× improvement in energy resolution at the NIF and OMEGA, respectively, and 20× improvement in data turnaround time. The substantially improved performance of the MRSnext is enabled by using electromagnets that provide a short focal plane (12–16 cm) and unprecedented flexibility for a wide range of applications. In addition to being able to measure neutron yield, apparent ion temperature, areal density, and plasma-flow velocity over a wide range of yields, the NIF MRSnext will be able to directly, uniquely assess the alpha heating of the fuel ions through measurements of the alpha knock-on tail in the neutron spectrum. The goal is to implement a radiation-hard electronic detection system capable of providing rapid data acquisition and analysis. The development of the MRSnext will also set the foundation for the more advanced, time-resolving MRSt and serve as a testbed for its implementation on the NIF.

47 OTHER INSTRUMENTATION↗

An interactive machine learning platform for analyzing multi-particle coincidence data from cold target recoil ion momentum spectroscopy

We present SCULPT (Supervised Clustering and Uncovering Latent Patterns with Training), a comprehensive software platform for analyzing tabulated high-dimensional multi-particle coincidence data from Cold Target Recoil Ion Momentum Spectroscopy (COLTRIMS) experiments. The software addresses critical challenges in modern momentum spectroscopy by integrating advanced machine learning techniques with physics-informed analysis in an interactive web-based environment. SCULPT implements uniform manifold approximation and projection for non-linear dimensionality reduction to reveal correlations in high-dimensional data. We also discuss potential extensions to deep autoencoders for feature learning and genetic programming for automated discovery of physically meaningful observables. A novel adaptive confidence scoring system provides quantitative reliability assessments by evaluating user-selected clustering quality metrics with predefined weights that reflect each metric’s robustness. The platform features configurable molecular profiles for different experimental systems, interactive visualization with selection tools, and comprehensive data filtering capabilities. Utilizing a subset of SCULPT’s capabilities, we analyze photo-double-ionization data measured using the COLTRIMS method for three-body dissociation of the D 2 O molecule, revealing distinct fragmentation channels and their correlations with physics parameters. The software’s modular architecture and web-based implementation make it accessible to the broader atomic and molecular physics community, significantly reducing the time required for complex multi-dimensional analyses. This opens the door to finding and isolating rare events exhibiting non-linear correlations on the fly during experimental measurements, which can help steer exploration and improve the efficiency of experiments.

Artificial neural networks↗

Evaluating the diffusion of Kr in UO 2 and ADOPT TM using time-of-flight elastic recoil detection analysis (ToF-erda)

A combination of 300 keV 84 Kr ion implantation and Time-of-Flight Elastic Recoil Detection Analysis is utilized to investigate the diffusion of Kr in UO 2 and ADOPT TM fuels. Composition depth-profiles on the nanometer scale were obtained, both for as-implanted samples and after annealing at 800°C for 1 hour. Observed drifts in the 84 Kr profiles could be associated with short-range diffusion mechanisms. The approach employed here provides the possibility to make direct comparisons with atomistic scale modelling data, and can be of service as a separate effect test in line with the Accelerated Fuel Qualification initiative.

ADOPT UO2↗

Optimization and characterization of a silicon photomultiplier-based ZnS(Ag) proton recoil fast neutron detector for nuclear fuel performance monitoring at TREAT

The restart of the Transient Reactor Test Facility (TREAT) at Idaho National Laboratory and consequent refurbishment of the Fuel Motion Monitoring System (FMMS), or Hodoscope, offers the opportunity to upgrade the detector system used for neutron imaging. Silicon photomultipliers (SiPMs) are a viable option for updating the Hodoscope to yield improved fuel monitoring capability. The Hodoscope uses ZnS(Ag) proton recoil scintillators (PRS) that provide good gamma-ray suppression and discrimination. Previous work showed that the Hamamatsu S13360-6075CS SiPM offers the best neutron detection and gamma-ray discrimination capability with the ZnS PRS. This work optimizes a SiPM-based detector and develops a PRS prototype for testing. Specifically, possible overvoltages for use are determined by confirming steady operation over extended measurement times. In addition, various SiPM-circuit implementations are tested to optimize the detector according to desired properties, and ultimately a PRS prototype is developed with modifiable components for versatile testing. Measurements of the neutron detection efficiency and gamma-ray rejection efficiency of SiPM-based PRS detectors and a reference PMT-based detector are also carried out. Neutron detection efficiency ranges between 1-2%, and detected gamma-ray rejection efficiency is on the order of 10 -7 . In conclusion, use of a low-pass filter only or a low-pass filter and 50-ω shunt resistor is recommended for the SiPM-based detector, and both configurations demonstrate improved performance over the PMT-based detector.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗